English
Volta supply a range of cleaners with different accessories, all of which are covered
in this manual. Please refer to your specific model and its accessories.
Keep both cover flaps open and cross-reference the text with pictures where
necessary.
Modelys Accessories (all models)
TM
s-bag
Swivel hose and handle with manual suction control
Combination carpet/hard floor nozzle
Narrow crevice nozzle
Upholstery nozzle
Hard floor nozzle
Modelys Accessories (some models)
Extension tubes (x2)
Telescopic tube
Ensuring your safety
The cleaner is for domestic use only and has been designed to ensure maximum
safety and performance. Please follow these simple precautions:
The cleaner is double insulated so it must not be earthed
The cleaner is only to be used by adults
Do not pick up very fine dust (plaster, cement, cold cinders...)
Always store in a dry place
Do not use to pick up liquids
Avoid sharp objects
Do not pick up hot cinders or lighted cigarette ends
Do not use near flammable gases
Avoid tugging on the mains cable and check cable regularly for damage
Note: Do not use cleaner with a damaged cable.
If damaged the cable should be replaced at a service centre
The plug must be removed from the socket -outlet before cleaning or
maintaining the appliance
All service and repairs must be carried out by authorised service staff
A Mains cable
B Cable rewind button
C Mechanical s-bagTMfull indicator
D Hose connection
E Carrying handle
F Cover release catch for s-bagTMcompartment
G Cover release for accessory compartment
H On/off button
I Parking position for tube and nozzle when in use
J Storage slot for tube and nozzle when not in use
K Suction control regulator
Getting Started
1Check the s-bagTMis in place.
2 Insert the hose until the catches click to engage
(press catches inwards to release).
3 Attach extension tubes or telescopic tube (some models) to the hose
handle and floor nozzle and twisting together (twist and pull apart to
dismantle).
4 Extend the cable and connect to mains, ensuring the cable is not
twisted before use (Press cable rewind button to rewind cable. Please
hold the plug to prevent it striking you).
5 Press the on/off button to start the cleaner.
6 To increase/decrease suction, adjust the rolling wheel control. Suction
can also be regulated on the hose handle by opening/closing the vent.
Features of the Modelys range
Getting the best results
Carpets:
Use floor nozzle with lever in this position.
Hard floors:
Loose rugs/curtains/lightweight fabrics:
the floor nozzle for loose rugs and the upholstery nozzle for curtains,
cushions etc.
Confined areas:
Hard floor/Parquetry:
Use floor nozzle with lever in this position.
Reduce the suction power. Use
Use the crevice nozzle for tight corners and radiators etc.
use the hard floor nozzle to avoid scratching

3
s-bagTMindicator and changing the s-bag
For peak performance the s-bagTMshould be changed when full. The
mechanical s-bagTMindicator window will gradually turn red when filling
and completely red when full.
If the dust bag should get broken in the cleaner, take cleaner to service
centre for cleaning. This is not covered by the guarantee.
The s-bagTMfull indicator may signify that the bag is blocked
(occasionally caused by finer dust) which will cause loss of suction and
may result in overheating. If this occurs change the bag even if it is not
full. DO NOT VACUUM VERY FINE DUST (PLASTER, CEMENT, COLD CINDERS...).
To check the dustbag, the cleaner must be switched on, with all
attachments connected but the nozzle does not have to be placed on the
floor.
To change the s-bagTM:
7 Open the cleaner cover.
8 Remove the s-bagTMholder and pull the sliding tab to remove the s-
bagTMfrom its holder.
9 Insert the new s-bagTMby sliding the bag slots into the holder. Close
cover.
10 Make sure that the dustbag (s-bagTM) is not overlapping with the
rubber sealing. (Push downwards before inserting the dustbag holder
into the dustbag compartement)
We recommend the s-bagTMis changed after using a carpet cleaning
powder or if there is a bad smell from the cleaner.
Note: Only use original s-bagsTMand filters
s-bagTM(ref. s-bagTM)
Motor protection filter (ref. D55)
Exhaust filter/Micro filter (ref. D09)
TM
Troubleshooting
Dustbag:
please check that the dustbag is placed correctly and ensure
that it is not jammed. (10)
Power:
if the electric power does not come on, disconnect from mains
and check plugs, cable and fuses where appropriate.
The cleaner may switch itself off in event of severe blockage or
excessively dirty filters. In such cases, disconnect from mains and allow
to cool for 30 minutes. Clear blockage and/or replace filter(s) and restart.
The clearing of blocked hoses is not covered by the guarantee. To avoid
blockages and maintain suction efficiency, the floor nozzles should be
cleaned regularly using the hose handle.
Please see additional Volta information towards the back of this booklet.
Water:
if water is sucked into the cleaner the motor must be changed at a
service centre. This is not covered by the guarantee.
s-bagTMsafety device
To avoid damaging the cleaner, do not use it without a dust bag. A safety
device is fitted which prevents the cover closing without a dust bag in
place. Do not attempt to force cover shut.
Changing/cleaning the filters
Never use the cleaner without the filters in place.
The filters should be changed/cleaned approximately every fifth dust bag.
To maintain Motor Protection filter:
7 Open the cleaner cover.
11 Remove the filter unit, rinse the filter under warm tap water only and
dry the filter completely (14). The original filtering performance is
now restored. Replace the unit back into the cleaner and close cover
ensuring it is securely in place and the cover is properly closed.
Latest every second year replace the old filter with a new one.
To maintain Exhaust filter/Micro filter (some models):
12 Press the catch to open the filter cover.
13 Remove the filter unit, rinse the filter under warm tap water only and
dry the filter completely (14). The original filtering performance is
now restored. Replace the unit back into the cleaner and close cover
ensuring it is properly fastened.
Latest every second year replace the old filter with a new one.