AEG DD8696-M9 User Manual

DD 8696
Dunstabzugshaube
Afzuigkap
Hotte
Cooker Hood
Montage- und Gebrauchsanweisung
Installatie- en gebruiksaanwijzing
Notice dutilisation et dinstallation
Contents
Safety warnings .............................................................................. 56
For the user ...................................................................................... 56
For the installer ................................................................................. 57
Description of the Appliance ......................................................... 59
Extraction mode................................................................................ 59
Recirculation mode ........................................................................... 59
Control Panel .................................................................................. 60
Maintenance and Care ................................................................... 62
Cleaning the hood ............................................................................. 62
Metal grease filter ............................................................................. 62
Removing the front panels ................................................................. 62
Removing the metal grease filter........................................................ 63
Charcoal filter .................................................................................... 64
Changing the light bulb ...................................................................... 65
Technical assistance service ........................................................ 66
Technical Specifications ................................................................ 67
Mounting accessories included ......................................................... 67
What to do if ................................................................................... 68
Special accessories ........................................................................ 69
Electrical connection ..................................................................... 69
Wall mounting ................................................................................... 70
55
Safety warnings
For the user
 The cooker hood is designed to extract unpleasant odours from the
kitchen, it will not extract steam.
 Always cover lighted elements, to prevent excess heat from
damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames.
 Also, when frying, keep the deep frying pan on the cooker top/cooker
under careful control.  The hot oil in the frying pan might ignite due to overheating.  The risk of self-ignition increases when the oil being used is dirty.  It is extremely important to note that overheating can cause a fire.  Never carry out any flambé cooking under the hood.Always disconnect the unit from the power supply before
carrying out any work on the hood, including replacing the
light bulb (take the cartridge fuse out of the fuse holder or switch off
the automatic circuit breaker).  It is very important to clean the hood and replace the filter at
the recommended intervals. Failure to do so could cause
grease deposits to build up, resulting in a fire hazard.
 The appliance is not intended for use by young children or infirm
persons without supervision.  Older children must be supervised if using the appliance.  Young children should be supervised to ensure that they do not play
with the appliance.  WARNING - Ensure that the appliance is switched off before
replacing the lamp to avoid the possibility of electric shock.
This appliance is marked according to the European directive 2002/96/ EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal. For more detailed information about treatment, recovery and recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
56
For the installer
 When used as an extractor unit, the hood must be fitted with a
150mm diameter hose.
 Should there already be a pipe of diameter 125 or 120 mm that ducts
to the outside through the walls, it is possible to use the 150/125­120 mm reduction flange provided. In this case the hood will be slightly noisier.
 When installing the hood observe the following minimum
distances from the cooking top: Electric cooking tops 450mm Attention! The hood must not be installed over gas hob.
 The national Standard on fuel-burning systems specifies a maximum
depression of 0.04 mbar in such rooms.
 The air outlet must not be connected to chimney flues or combustion
gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.
 The air outlet installation must comply with the regulations laid down
by the relevant local authorities.
 When the unit is used in extraction mode, a sufficiently large
ventilation hole must be provided, with dimensions that are approxi­mately the same as the outlet hole.
 National and regional building regulations impose a number of
restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.
 Hoods can only be used safely with appliances connected to a
chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.
 If you have any doubts, contact the relevant controlling authority or
building inspectors office.
 Since the rule for rooms with fuel burning appliances is outlet hole of
the same size as the ventilation hole, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.
 If the hood is used in its recirculation mode, it will operate simply
and safely in the above conditions without the need for any of the aforementioned measures.
 When the hood is used in its extraction mode, the following rules
must be followed to obtain optimal operation:
short and straight outlet hose
57
keep bends in outlet hose to a minimum never install the hoses with an acute angle, they must always
follow a gentle curve.
keep the hose as large as possible (preferably the same diameter
as the outlet hole).
the length should be no more than:
3 metres with one 90° bend 2 metres with two 90° bends Bends of more than 90° will reduce the efficiency of the hood and reduce the airflow.
 Failure to observe these basic instructions will drastically reduce the
performance and increase the noise levels of the extractor hood.
58
Description of the Appliance
The cooker hood is designed to extract unpleasant odours
from the kitchen, it will not extract steam.
 The hood is supplied as an extractor unit and can also be used with
a recirculation mode by fitting a charcoal filter.
 In some models the charcoal filter is supplied. The hood, therefore,
can be used immediately in the recirculation mode. We advise removing the charcoal filter to use the hood in the extraction mode.
reduction flange
Extraction mode
 In this mode fumes are
extracted to the outside via a hose connected to the coupling ring. Fig. 1.
 In order to obtain the best
performance the hose should have a diameter equal to the outlet hole.
 Should there already be a
pipe of diameter 125 or 120 mm that ducts to the outside through the walls, it is possible to use the 150/125-120 mm reduction flange provided. In this case the hood will be slightly noisier.
coupling ring
Fig. 1
Recirculation mode
 The air is filtered through a
charcoal filter and returned to the kitchen.
 You will need an original
charcoal filter for the recirculation mode. (See Special Accessories).
 Fix the deflector using 2 screws
Ø 3.5x9.5 mm. Fig. 2.
Fig. 2
Deflector
59
Control Panel
 Best results are obtained by using a low speed for normal conditions
and a high speed when odours are more concentrated.
Turn the hood on a few minutes before you start cooking.
The hood should be left on after cooking for about 15 minutes or until
all the odours have disappeared.  The hood can also be commanded from the control panel or the
remote control. (the remote control is a special accessory and is
ordered separately). The control panel is low on the left (lights and reset filters) and right (speed control  suction power).
Fig. 3
ab
1
1 - Mains switch, ON/OFF
Press for less than 1 1/2 seconds and the cooker hood goes into the "stand by" position (point "b" is illuminated). Press for more than 1 1/2 seconds and the cooker hood turns off, ALL the controls (except the light push button) are disabled (the display is off). Press again for more than 1 1/2 seconds to reset the cooker hood to "stand by".
2 - Cooking top lights OFF key: -suffused  full light-OFF- . 3 - Reset indicators of filters saturation key 4 - Upper lights key: OFF  full light-OFF- 
5 - Start and choice of motor speed 1-2-3-1-2.........
6 - Display 7 - Intensive speed on/off. The Intensive speed runs for 5 minutes:
If the hood is on when the Intensive speed is activated, the hood will revert to previous speed after 5 minutes. If the hood is off when the Intensive speed is activated, the hood will automatically turn off after 5 minutes. To interrupt the Intensive speed, press button 1 or 7. The letter P appears on the display and the remaining time (the point a is flashing), if interrupted an acoustic signal is heard.
60