Part No. XXXXXXXXXXEdition 1
Printed in TaiwanSeptember 2016
The documentation and the software included with this product are copyrighted 2016
by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right
to make improvements in the products described in this manual at any time without
notice. No part of this manual may be reproduced, copied, translated or transmitted
in any form or by any means without the prior written permission of Advantech Co.,
Ltd. Information provided in this manual is intended to be accurat e and reliable. However, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringements of the rights of third parties, which may result from its use.
Acknowledgements
Intel and Pentium are trademarks of Intel Corporation.
Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp.
All other product names or trademarks are properties of their respective owners.
Product Warranty (5 years)
Advantech warrants to you, the original purchaser, that each of its products will be
free from defects in materials and workmanship for five years from the date of purchase.
This warranty does not apply to any products which have been repaired or altered by
persons other than repair personnel authorized by Advantech, or which have been
subject to misuse, abuse, accident or improper installation. Advantech assumes no
liability under the terms of this warranty as a consequence of such events.
Because of Advantech’s high quality-control standards and rigorous testing, most of
our customers never need to use our repair service. If an Advantech product is defective, it will be repaired or replaced at no charge during the warranty pe riod. For out ofwarranty repairs, you will be billed according to the cost of replacement materials,
service time and freight. Please consult your dealer for more details.
If you think you have a defective product, follow these steps:
1.Collect all the information about the problem encountered. (For example, CPU
speed, Advantech products used, other hardware and software used, etc.) Note
anything abnormal and list any on screen messages you get when the problem
occurs.
2.Call your dealer and describe the problem. Please have your manual, product,
and any helpful information readily available.
3.If your product is diagnosed as defective, obtain an RMA (return merchandize
authorization) number from your dealer. This allows us to process your return
more quickly.
4.Carefully pack the defective product, a fully-completed Repair and Replacement
Order Card and a photocopy proof of purchase date (such as your sales receipt)
in a shippable container. A product returned without proof of the purchase date
is not eligible for warranty service.
5.Write the RMA number visibly on the outside of the package and ship it prepaid
to your dealer.
EKI-9500 Series User Manualii
Declaration of Conformity
CE
This product has passed the CE test for environmental specifications when shielded
cables are used for external wiring. We recommend the use of shielded cables. This
kind of cable is available from Advantech. Please contact your local supplier for
ordering information.
This product has passed the CE test for environmental specifications. Test conditions
for passing included the equipment being operated within an industrial enclosure. In
order to protect the product from being damaged by ESD (Electrostatic Discharge)
and EMI leakage, we strongly recommend the use of CE-compliant industrial enclosure products.
FCC Class A
Note: This equipment has been tested and found to comply with the limit s for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
FCC Class B
Note: This equipment has been tested and found to comply with the limit s for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FM
This equipment has passed the FM certification. According to the National Fire Protection Association, work sites are classified into different classes, divisions and
groups, based on hazard considerations. This equipment is compliant with the specifications of Class I, Division 2, Groups A, B, C and D indoor hazards.
iiiEKI-9500 Series User Manual
Technical Support and Assistance
1.Visit the Advantech web site at www .advantech.com/support where you can find
the latest information about the product.
2.Contact your distributor, sales representative, or Advantech's customer service
center for technical support if you need additional assistance. Please have the
following information ready before you call:
– Product name and serial number
– Description of your peripheral attachments
– Description of your software (operating system, version, application software,
etc.)
– A complete description of the problem
– The exact wording of any error messages
Warnings, Cautions and Notes
Warning! Warnings indicate conditions, which if not observed, can cause personal
injury!
Caution! Cautions are included to help you avoid damaging hardware or losing
data. e.g.
There is a danger of a new battery exploding if it is incorrectly installed.
Do not attempt to recharge, force open, or heat the battery. Replace the
battery only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer's
instructions.
Note!Notes provide optional additional information.
Document Feedback
To assist us in making improvements to this manual, we would welcome comments
and constructive criticism. Please send all such - in writing to: support@advantech.com
Packing List
Before setting up the system, check that the items listed below are included and in
good condition. If any item does not accord with the table, please contact your dealer
immediately.
1 x Full Managed Ethernet Switch
1 x Startup Manual
EKI-9500 Series User Manualiv
Safety Instructions
1.Read these safety instructions carefully.
2.Keep this User Manual for later reference.
3.Disconnect this equipment from any AC outlet before cleaning. Use a damp
cloth. Do not use liquid or spray detergents for cleaning.
4.For plug-in equipment, the power outlet socket must be located near the equip-
ment and must be easily accessible.
5.Keep this equipment away from humidity.
6.Put this equipment on a reliable surface during installation. Dro pping it or letting
it fall may cause damage.
7.The openings on the enclosure are for air convection. Protect the equipment
from overheating. DO NOT COVER THE OPENINGS.
8.Make sure the voltage of the power source is correct before connecting the
equipment to the power outlet.
9.Position the power cord so that people cannot step on it. Do not place anything
over the power cord.
10. All cautions and warnings on the equipment should be noted.
11.If the equipment is not used for a long time, disconnect it from the power source
to avoid damage by transient overvoltage.
12. Never pour any liquid into an opening. This may cause fire or electrical shock.
13. Never open the equipment. For safety reasons, the equipment should be
opened only by qualified service personnel.
14. If one of the following situations arises, get the equipment checked by service
personnel:
15. The power cord or plug is damaged.
16. Liquid has penetrated into the equipment.
17. The equipment has been exposed to moisture.
18. The equipment does not work well, or you cannot get it to work according to the
user's manual.
19. The equipment has been dropped and damaged.
20. The equipment has obvious signs of breakage.
21. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE
STORAGE TEMPERA TURE MAY GO BELOW -20° C (-4° F) OR ABOVE 60° C
(140° F). THIS COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT
SHOULD BE IN A CONTROLLED ENVIRONMENT.
22. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY
REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE
RECOMMENDED BY THE MANUFACTURER, DISCARD USED BATTERIES
ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS.
23. The sound pressure level at the operator's position according to IEC 704-1:198 2
is no more than 70 dB (A).
DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech
disclaims all responsibility for the accuracy of any statements contained herein.
vEKI-9500 Series User Manual
Wichtige Sicherheishinweise
1.Bitte lesen sie Sich diese Hinweise sorgfältig durch.
2.Heben Sie diese Anleitung für den späteren Gebrauch auf.
3.Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie
Keine Flüssig-oder Aerosolreiniger. Am besten dient ein angefeuchtetes Tuch
zur Reinigung.
4.Die NetzanschluBsteckdose soll nahe dem Gerät angebracht und leicht zugän-
glich sein.
5.Das Gerät ist vor Feuchtigkeit zu schützen.
6.Bei der Aufstellung des Gerätes ist auf sicheren Stand zu achten. Ein Kippen
oder Fallen könnte Verletzungen hervorrufen.
7.Die Belüftungsöffnungen dienen zur Luftzirkulation die das Gerät vor überhit-
zung schützt. Sorgen Sie dafür, daB diese Öffnungen nicht abgedeckt werden.
8.Beachten Sie beim. AnschluB an das Stromnetz die AnschluBwerte.
9.Verlegen Sie die Netza nschluBleitung so , daB niemand darüber fallen kann. Es
sollte auch nichts auf der Leitung abgestellt werden.
10. Alle Hinweise und Warnungen die sich am Geräten befinden sind zu beachten.
11.Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten Sie es vom
Stromnetz trennen. Somit wird im Falle einer Übersp annung eine Beschädigung
vermieden.
12. Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder Flü ssigkeiten in
das Gerät gelangen. Dies könnte einen Brand bzw. elektrischen Schlag auslösen.
13. Öffnen Sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen
Sicherheit nur von authorisiertem Servicepersonal geöffnet werden.
14. Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen
und von einer qualifizierten Servicestelle zu überprüfen:
15. Netzkabel oder Netzstecker sind beschädigt.
16. Flüssigkeit ist in das Gerät eingedrungen.
17. Das Gerät war Feuchtigkeit ausgesetzt.
18. Wenn das Gerät nicht der Bedienungsanleitung entsprechend funktioniert oder
Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen.
19. Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt.
20. Wenn das Gerät deutliche Anzeichen eines Defektes aufweist.
21. VOSICHT: Explisionsgefahr bei unsachgemaben Austausch der Batterie.Ersatz
nur durch densellben order einem vom Hersteller empfohlene-mahnlichen Typ.
Entsorgung gebrauchter Batterien navh Angaben des Herstellers.
22. ACHTUNG: Es besteht die Explosionsgefahr, falls die Batterie auf nicht fach-
männische Weise gewechselt wird. Verfangen Sie die Batterie nur gleicher oder
entsprechender Type, wie vom Hersteller empfohlen. Entsorgen Sie Batterien
nach Anweisung des Herstellers.
23. Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 beträgt
70dB(A) oder weiger.
Haftungsausschluss: Die Bedienungsanleitungen wurden entsprechend der IEC704-1 erstellt. Advantech lehnt jegliche Verantwortung für die Richtigkeit der in diesem Zusammenhang getätigten Aussagen ab.
EKI-9500 Series User Manualvi
Safety Precaution - Static Electricity
Follow these simple precautions to protect yourself from harm and the products from
damage.
To avoid electrical shock, always disconnect the power from your PC chassis
before you work on it. Don't touch any components on the CPU card or other
cards while the PC is on.
Disconnect power before making any configuration changes. The sudden rush
of power as you connect a jumper or install a card may damage sensitive electronic components.
viiEKI-9500 Series User Manual
Technical Support and Assistance
1.Visit the Advantech web site at www .advantech.com/support where you can find
the latest information about the product.
2.Contract your distributor , sales represent ative, or Advantech's customer service
center for technical support if you need additional assistance. Please have the
following information ready before you call:
– Product name and serial number
– Description of your peripheral attachment
– Description of your sof tware (operating system, version, application sof tware,
etc.)
– A complete description of the problem
– The exact wording of any error messages
About This Manual
This user manual is intended to guide professional installers in installing and configuring the serial device server. It includes technical specifications, as well as procedures for the management of the devices.
Figure 4.286Security > Port Access Control > Configuration... 259
Figure 4.287Security > Port Access Control > Port Summary . 260
Figure 4.288Security > Port Access Control > Port
ShockIEC 61373 Cat 1 Class B
FreefallIEC 60068-2-32
VibrationIEC 61373 Cat 1 Class B
3EKI-9500 Series User Manual
1.3Hardware Views
1
3
4
67
9
8
2
5
1.3.1Front View
The following view applies to EKI-9516 and EKI-9516D.
DATADATADATA
1
2
3
4
5
4
6
3
7
2
1
8
Pair
Pin
+
1
DA
-
2
DA
+
DB
3
-
4
DB
+
DD
5
-
6
DD
-
7
DC
+
8
DC
EKI-9516
5
6
4
3
4
1
5
Power
PWR2
Pin PWR
+
L1
1
/
V
-
2
L1/V
2
3
GND
+
4
L2/
V
-
5
L
2/V
6
NA
3
1
6
2
3
Console
ALM
PWR1
SYS
CFG
ALM
153
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Pin
1
2
3
4
5
DATA
13
14
15
16
2
4
Signal
DN
VBUS
NC
DP
GND
Signal
TX
RX
DSR
GND
DTR
Pair
P1-N
P1-P
P2-N
P2-P
NA
9
10
11
12
5
6
7
8
Figure 1.1 Front View
No. ItemDescription
1USB portM12 5-pin (female) port for FW backup access.
2Ground terminalScrew terminal used to ground chassis.
3Console portM12 5-pin (female) port to access the managed switch's soft-
ware.
4Power input portM23 connector 6-pin (male) DC power connector port.
5Alarm portM12 5-pin (female) port to attach monitoring wires.
6ETH port
EKI-9516: 10/100/1000BaseT(X) x 4 (X-coding)
EKI-9516D: 10/100/1000BaseT(X) x 4 (D-coding)
7ETH port
EKI-9516: 10/100/1000BaseT(X) x 12 (X-coding)
EKI-9516D: 10/100/1000BaseT(X) x 12 (D-coding)
8Mounting screw hole Screw holes (x6) used in the installation of a wall mounting plate
9System LED panelSee “System LED Panel” on page 8 for further details.
EKI-9500 Series User Manual4
The following view applies to EKI-9516P-HV, EKI-9516P-LV, EKI-9516DP-HV and
1
3
4
67
9
8
2
5
EKI-9516DP-LV.
PoEDATAPoEDATAPoEDATA
1
2
3
4
5
4
6
3
7
2
1
8
Pair
Pin
+
1
DA
-
2
DA
+
DB
3
-
4
DB
+
DD
5
-
6
DD
-
7
DC
+
8
DC
EKI-9516P
1
5
6
4
3
5
4
Power
PWR2
Pin PWR
+
L1
1
/
V
-
2
L1/V
2
GND
3
+
4
L2/
V
-
5
L
2/V
6
NA
3
1
6
2
3
Console
ALM
PWR1
SYS
CFG
ALM
153
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Pin
1
2
3
4
5
DATA
13
14
15
16
2
4
Signal
DN
VBUS
NC
DP
GND
Signal
TX
RX
DSR
GND
DTR
Pair
P1-N
P1-P
P2-N
P2-P
NA
9
10
11
12
5
6
7
8
Figure 1.2 Front View
No. ItemDescription
1USB portM12 5-pin (female) port for FW backup access.
2Ground terminalScr ew terminal used to ground chassis.
3Console portM12 5-pin (female) port to access the managed switch's soft-
ware.
4Power input portM23 connector 6-pin (male) DC power connector port.
5Alarm portM12 5-pin (female) port to attach monitoring wires.
6ETH port
EKI-9516P-HV and EKI-9516P-L V : 10/100/1000BaseT(X) x
4 (X-coding)
EKI-9516DP-HV and EKI-9516DP-LV: 10/100/
1000BaseT(X) x 4 (D-coding)
7ETH port
EKI-9516P-HV and EKI-9516P-L V : 10/100/1000BaseT(X) x
12 (X-coding)
EKI-9516DP-HV and EKI-9516DP-LV: 10/100/
1000BaseT(X) x 12 (D-coding)
8Mounting screw hole Screw holes (x6) used in the installation of a wall mounting plate
9System LED panelSee “System LED Panel” on page 8 for further details.
5EKI-9500 Series User Manual
The following view applies to EKI-9512 and EKI-9512D.
1
3
4
67
9
8
2
5
EKI-9512
5
6
4
1
3
4
2
3
5
Power
PWR2
Pin PWR
+
L1
1
/
V
-
2
L1/V
3
GND
+
4
L2/
V
-
5
L
2/V
6
NA
1
6
2
3
Console
PWR1
SYS
CFG
ALM
153
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Pin
1
2
3
4
5
DATA
9
10
11
12
2
4
Signal
DN
VBUS
NC
DP
GND
Signal
TX
RX
DSR
GND
DTR
Pair
P1-N
P1-P
P2-N
P2-P
NA
5
6
7
8
ALM
DATADATA
1
2
3
4
5
4
6
3
7
2
1
8
Pair
Pin
+
1
DA
-
2
DA
+
DB
3
-
4
DB
+
DD
5
-
6
DD
-
7
DC
+
8
DC
Figure 1.3 Front View
No. ItemDescription
1USB portM12 5-pin (female) port for FW backup access.
2Ground terminalScrew terminal used to ground chassis.
3Console portM12 5-pin (female) port to access the managed switch's soft-
ware.
4Power input portM23 connector 6-pin (male) DC power connector port.
5Alarm portM12 5-pin (female) port to attach monitoring wires.
6ETH port
EKI-9512: 10/100/1000BaseT(X) x 4 (X-coding)
EKI-9512D: 10/100/1000BaseT(X) x 4 (D-coding)
7ETH port
EKI-9512: 10/100/1000BaseT(X) x 8 (X-coding)
EKI-9512D: 10/100/1000BaseT(X) x 8 (D-coding)
8Mounting screw hole Screw holes (x6) used in the installation of a wall mounting plate
9System LED panelSee “System LED Panel” on page 8 for further details.
EKI-9500 Series User Manual6
The following view applies to EKI-9512P-HV, EKI-9512P-LV, EKI-9512DP-HV and
1
3
4
67
9
8
2
5
EKI-9512DP-LV.
EKI-9512P
1
5
6
4
3
4
2
3
5
Power
PWR2
Pin PWR
+
L1
1
/
V
-
2
L1/V
GND
3
+
4
L2/
V
-
5
L
2/V
6
NA
1
6
2
3
Console
ALM
PWR1
SYS
CFG
ALM
153
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Pin
1
2
3
4
5
DATA
9
10
11
12
2
4
Signal
DN
VBUS
NC
DP
GND
Signal
TX
RX
DSR
GND
DTR
Pair
P1-N
P1-P
P2-N
P2-P
NA
5
6
7
8
PoEDATAPoEDATA
1
2
3
4
5
4
6
3
7
2
1
8
Pair
Pin
+
1
DA
-
2
DA
+
DB
3
-
4
DB
+
DD
5
-
6
DD
-
7
DC
+
8
DC
Figure 1.4 Front View
No. ItemDescription
1USB portM12 5-pin (female) port for FW backup access.
2Ground terminalScr ew terminal used to ground chassis.
3Console portM12 5-pin (female) port to access the managed switch's soft-
ware.
4Power input portM23 connector 6-pin (male) DC power connector port.
5Alarm portM12 5-pin (female) port to attach monitoring wires.
6ETH port
EKI-9512P-HV and EKI-9512P-L V : 10/100/1000BaseT(X) x
4 (X-coding)
EKI-9512DP-HV and EKI-9512DP-LV: 10/100/
1000BaseT(X) x 4 (D-coding)
7ETH port
EKI-9512P-HV and EKI-9512P-L V : 10/100/1000BaseT(X) x
8 (X-coding)
EKI-9512DP-HV and EKI-9512DP-LV: 10/100/
1000BaseT(X) x 8 (D-coding)
8Mounting screw hole Screw holes (x6) used in the installation of a wall mounting plate
9System LED panelSee “System LED Panel” on page 8 for further details.
7EKI-9500 Series User Manual
1.3.1.1 System LED Panel
3
12
4566 76 76 7
PWR 2
No. LED NameLED ColorDescription
PWR2Green onPower is being supplied to power input PWR2.
1
PWR1Green onPower is being supplied to power input PWR1.
2
SYSGreen onEKI switch system is ready.
3
CFGYellow onTBD
4
ALMRed onDefined major policies are detected.
5
DATAGreen onLink 1G
6
PoE
7
(only available in
EKI-9516P-LV,
EKI-9516P-HV,
EKI-9512P-LV,
EKI-9512P-HV,
EKI-9516DP-LV,
EKI-9516DP-HV,
EKI-9512DP-LV
and
EKI-9512DP-HV)
DATADATAPoEDATA PoEDATA PoE
PWR 1
SYS
CFG
ALM
13
14
15
16
9
10
11
12
5
6
7
8
1
2
3
4
Figure 1.5 System LED Panel
OffPower is not being supplied to power input
PWR2.
OffPower is not being supplied to power input
PWR1.
Blink green (1Hz) EKI switch system is under initiating.
Blink green (3Hz) TBD
Blink green (5Hz) TBD
OffPower on processing in U-Boot mode.
Blink red (1Hz)Defined minor policies are detected.
Blink red (3Hz)TBD
Blink red (5Hz)TBD
OffPower off or system alarm is cleared or masked.
Blink greenACT 1G
Amber onLink 10/100MB
Blink amberACT 10/100MB
OffLink down
Green onProviding power over 15. 4 W.
Blink greenPr ov idin g po we r un d er 15. 4 W.
OffUser turns off PoE mode at corresponding Giga-
bit Ethernet port.
EKI-9500 Series User Manual8
Chapter2
2Switch Installation
2.1Installation Guidelines
The following guidelines are provided to optimize the device performance. Review
the guidelines before installing the device.
Make sure cabling is away from sources of electrical noise. Radios, power lines,
and fluorescent lighting fixtures can interference with the device performance.
Make sure the cabling is positioned away from equipment that can damage the
cables.
Operating environment is within the ranges listed range, see “S pecifications” on
page 1.
Relative humidity around the switch does not exceed 95 percent (noncondens-
ing).
Altitude at the installation site is not higher than 10,000 feet.
In 10/100 and 10/100/1000 fixed port devices, the cable length from the switch
to connected devices can not exceed 100 meters (328 feet).
Make sure airflow around the switch and respective vents is unrestricted. With-
out proper airflow the switch can overheat. To prevent performance degradation
and damage to the switch, make sure there is clearance at the top and bottom
and around the exhaust vents.
2.1.1Connecting Hardware
These instructions explain how to find a proper location for your Modbus Gateways,
and how to connect to the network, hook up the power cable, and conne ct to the EKI9500 Series.
2.2Verifying Switch Operation
Before installing the device in a rack or on a wall, power on the switch to verify that
the switch passes the power-on self-test (POST). To connect the cabling to the power
source see “Power Supply Installation” on page 12.
At startup (POST), the System LED blinks green, while the remaining LEDs are a
solid green. Once the switch passes POST self-test, the System LED turns green.
The other LEDs turn off and return to their operating status. If the switch fails POST,
the System LED switches to an amber state.
After a successful self-test, power down the switch and disconnect the po wer cabling.
The switch is now ready for installation at its final location.
2.3Installing the Switch
2.3.1Wall-Mounting
Note!When installing, make sure to allow for enough space to properly install
the cabling.
1.Locate the installation site and place the switch against the wall, making sure it
is the final installation location.
EKI-9500 Series User Manual10
2.Insert the screws into the wall sinks. Leave a 6 mm gap between the wall and
10 mm
4.0 mm
(Max: 4.3mm)
4.0 mm
P
in
D
N
Si
gn
a
l
V
B
US
NCD
P
G
N
D
12345
P
in
TX
Si
gna
l
R
X
D
S
R
G
N
D
D
TR
1
2
3
4
5
P
in
P
1
-
N
P
1
-
P
P
2
-
N
P
2
-
P
P
a
i
r
1
2
3
4
5
N
A
P
in
P
ai
r
1
2
3
4
5
6
7
8
D
A
-
D
A
+
D
B
-
D
B
+
D
D
-
D
C
-
D
C
+
D
D
+
2
1
5
3
4
P
i
n
P
WR
G
N
D
N
A
12
3
4
5
6
L
1
/
V
+L
1
/
V
-
L
2
/
V
+
L
2
/
V
-
1
2
5
4
6
3
C
o
n
s
o
le
A
L
M
PoE
D
ATA
PoED
ATA
PoE
D
A
TA
1
2
8
7
6
5
4
3
1
2
3
4
5
6
7
8
9
10
1112
13
14
15
16
DATA
PWR1
SYS
C
FG
ALM
PWR2
EKI-9516P
P
o
wer
the screw head to allow for wall mount plate insertion.
Figure 2.1 Securing Wall Mounting Screws
Note!Make sure the screws dimensions are suitable for use with the
device.
Do not completely tighten the screws into the wall. A final adjust-
ment may be needed before fully securing the device on the wall.
3.Align the device over the screws on the wall.
4.Install the device on the screws and slide it downward to lock in place, see the
following figure.
5.Once the device is installed on the wall, tighten the screws to secure t he device.
Figure 2.2 Switch Installation
11EKI-9500 Series User Manual
Loading...
+ 296 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.