Advantech DLV4108 User Manual

Quick Start Guide DLT-V4108 Industrial PC
DLoG GmbH, 2016
1 / 15
1
Introduction – for your safety
Read and observe the quick start
guide carefully.
Keep for future reference. Read and observe the accompanying
“DLT-V4108 Safety Instructions carefully.
Go to www.advantech-dlog.com for
detailed manuals, e.g. “DLT-V4108 Manual” and “MDevice Manual”.
Figure: DLT-V4108 Industrial PC
DANGER
Observe the intended use.
Observe the intended use of DLT-V4108, e.g.: no use in EX zone (potentially explosive) and on ships, no use in life-supporting systems or security-critical facilities.
Observe the required qualification.
This quick start guide is intended for qualified skilled personnel. Only skilled personnel may transport, store, commission and maintain the DLT-V4108. Qualified and skilled personnel referred in this quick start guide are persons who are familiar with these processes and have the corresponding qualifications for their activities.
Hazardous voltage, electric shock from contact with live parts.
Do not put DLT-V4108 into operation if it is damaged. Do not open or modify DLT-V4108. Only connect or disconnect electrical connections when the device is in a de-energized state
(electrically dead)
Operators of the DLT-V4108 must be trained in the handling of the device. DLT-V4108 is intended to be supplied by DC power source, rated _9-60 Vdc, 5 A minimum and
Tma _45 degree C maximum, if need further assistance, please contact Advantech for further information."
Users must be trained / instructed.
Users of the DLT-V4108 must be trained by skilled personnel and instructed about the operation of the device.
Quick Start Guide
DLT-V4108 Industrial PC
2 / 15
Quick Start Guide DLT-V4108, V001
DLoG GmbH, 2016
CAUTION
Hazards that pose a risk to life and limb - Personal injury
Possible property damage:
DANGER / WARNING / CAUTION
DANGER: Danger that immediately leads to death or severe injury. WARNING: Danger that can lead to death or severe injury. CAUTION: Danger that can lead to slight injuries.
NOTICE: Physical damage
Information about possible physical damage.
2
Technical data of DLT-V4108
DLT-V4108
Weight
3.35 kg
Dimensions
290 x 230 x 60.5 mm (width x height x depth)
Operating temp.
-20 to +45 °C
Storage temp.
-20 to +50 °C
Relative humidity
10~95% non-condensing, ambient temperature 25 °C
IP Protection class
IP65
Replaceable Battery.
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Design method in our quick start guide:
Quick Start Guide DLT-V4108 Industrial PC
DLoG GmbH, 2016
3 / 15
3
Operation of DLT-V4108
NOTICE: Physical damage
Users of DLT-V4108 must be trained by skilled personnel and instructed about the operation of the device.
Left side:
- Power on/off
- Display brighter
- Display darker
- Backlighting on/off
- Touchscreen on/off
- SHIFT
Right side:
- S1 to S12 programmable keys
Enter data
You can enter data using the touchscreen and the built in integrated keyboard.
Operate the touchscreen with:
Clean, dry fingers. Clean, dry, thin gloves. Suitable touch stylus
Front keys
Quick Start Guide
DLT-V4108 Industrial PC
4 / 15
Quick Start Guide DLT-V4108, V001
DLoG GmbH, 2016
System Status
LED Status
Color
System power on
Static
Green
System power off
Off
x
System over/under temperature
Static
Red
System UPS Battery is charging
Static
Orange
System thermal sensor faculty
Blinking
0.5 sec. on / 0.5 sec. off
Red
System UPS Battery Capacity Low
Blinking
0.2 sec. on / 0.8 sec. off
Orange
System is powered by UPS battery only
Blinking
0.5 sec. on / 0.5 sec. off
Green
Touch Status
LED Status
Color
Touch function ON
Off
x
Touch function OFF
Static
Orange
System Status
LED Status
Color
System switch to S1/S2/S3/S4/S5/S6
Off
x
System switch to S7/S8/S9/S10/S11/S12
Static
Orange
LED indication on “Power ON /OFF “Key
LED indication on Touch ON/OFF “Key
LED indication on SHIFT “Key
Quick Start Guide DLT-V4108 Industrial PC
DLoG GmbH, 2016
5 / 15
4
Software configuration with MDevice
You can find details on configuration in the "MDevice Manual” at www.advantech-
dlog.com.
4.1 Wireless technology
WARNING
DLT-V4108 Industrial PCs are configured with the MDevice software, e.g., with regard to Wi-Fi settings, network settings, front key assignment, etc.
Start MDevice via Start -> Programs -> DLoG: MDevice. Enter the standard password: gold.
Only authorized skilled personnel are permitted to configure the wireless settings on DLT-V4108.
Safety information about radio wave emissions
To comply with the SAR limited values for exposure to radio waves:
While the device is in operation, the antenna must have a distance of ≥ 20 cm to the body. Make sure that the transmission power and the radio frequency of DLT-V4108 comply with the
regulations for the respective country where the device is deployed.
Depending on the country-specific regulations, the operating company/importing company may
be required to ensure the settings of wireless operation are compliant. The regulatory authorities in the relevant country can provide information on this.
Any changes or modifications which are not expressly approved by the party responsible for the compliance can lead to the withdrawal of the operating license and guarantee for this device.