Adtran NetVanta HSSI Quick Start Guide

For more detailed documentation, visit us online at www.adtran.com
Quick Start Guide
NETVANTA HSSI WIDE MODULE P/N 1200934L1
SPECIFICATIONS
Interface Type: 50 pin SCSI-II female connector
Line Rate: 0-52 Mbps
Signal Type:
Diagnostics/Testing:
HSSI Loopbacks, HSSI External loopback control with T3SU or DSU/CSU
Environmental: Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: up to 95% Noncondensing
Compliance: FCC Part 15 Class A, UL 60950/CSA-C22.2
No. 60950, EN 60950, IEC 60950, AS/NZS 60950, EN 55022, EN 54024
INSTALLATION INSTRUCTIONS
1. Remove the cover plate from the appropriate option slot in the NetVanta 5305 Base Unit.
HSSI PINOUT
PIN# (+ side) PIN# (- side) Direction Description
1 26 HSSI SG - Signal Ground 2 27 I HSSI RT - Receive Timing 3 28 I HSSI CA - DCE Available 4 29 I HSSI RD - Receive Data 5 30 I HSSI LC - Loopback Circuit C 6 31 I HSSI ST - Send Timing 7 32 HSSI SG - Signal Ground 8 33 O HSSI TA - DTE Available
9 34 O HSSI TT - Terminal Timing 10 35 O HSSI LA - Loopback Circuit A 11 36 O HSSI SD - Send Data 12 37 O HSSI LB - Loopback Circuit B 13 38 HSSI SG - Signal Ground 14 No Connection 15 40 No Connection 16 41 No Connection 17 42 No Connection 18 43 No Connection 19 44 HSSI SG - Signal Ground 20 45 No Connection 21 46 No Connection 22 47 No Connection 23 No Connection 24 49 I HSSI TM - Test Mode 25 50 HSSI SG - Signal Ground
2. Slide the NetVanta HSSI Wide Module into the option slot until the module is firmly positioned against the front of the chassis.
3. Secure the thumbscrews at both edges of the module. Tighten with a screwdriver.
4. Connect the cables to the associated device(s).
5. Complete the installation of the system as specified in the Hardware Installation Guide (P/N 61200890L1-34 or P/N 61200990L1-34).
Quick Start Guide, 61200934L1-13A, July 2004 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright © 2004 ADTRAN, All Rights Reserved
For more detailed documentation, visit us online at www.adtran.com
Quick Start Guide
NETVANTA HSSI WIDE MODULE P/N 1200934L1
COMMANDS
alias <text>
Comment line to provide text describing the interface.
<text> Up to 80 alphanumeric characters
description <text>
Comment line to provide an identifier for this interface (for example, circuit ID, contact information, etc.)
<text> Up to 80 alphanumeric characters
external-loopback-request
Enables LC (Loopback circuit C) input to control loopback towards the network.
no external-loopback-request
Disables LC (Loopback circuit C) input control of loopback.
loopback {dce | dte | line | remote | none} Initiates or removes the specified loopback.
dce Loops the physical interface toward the DCE.
dte Commands the DCE to loopback to DTE.
line Commands the DCE to loopback toward the DTE at
the line port.
remote Commands the remote DCE device to loopback for
purposes of testing data communication channels.
none Removes the loopback.
shutdown
Turns off the interface. The no version of this command turns the interface on and allows it to pass data.
snmp trap link-status
Enables the interface to send SNMP traps when the link status changes and controls the SNMP variable, ifLinkUpDownTrap Enable. The default is enabled.
Quick Start Guide, 61200934L1-13A, July 2004 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright © 2004 ADTRAN, All Rights Reserved
Loading...