Adtran Dual FXO Module User Manual

FXO+ DUAL VOICE OPTION MODULE
Part Number 1200103L2
&
FXO+ DUAL VOICE PLUG-ON BOARD
Part Number 1200104L2
USER MANUAL
61200.103L2-1B March 1997
Table of Contents
901 Explorer Boulevard
P.O. Box 140000
Huntsville, AL 35814-4000
Phone: (205) 963-8000
All rights reserved.
Printed in U.S.A.
Table of Contents
FEDERAL COMMUNICATIONS COMMISSION
RADIO FREQUENCY INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio frequencies. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Shielded cables must be used with this unit to ensure compliance with Class A FCC limits.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Table of Contents
FEDERAL COMMUNICATIONS COMMISSION (FCC)
INFORMATION
FCC regulations require that the following information be provided to the customer in this manual:
1. This equipment complies with Part 68 of the FCC rules. The required label is affixed to the bottom of the chassis.
2. If your telephone equipment (FXO+) causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance. But if advance notice is not practical, you will be notified as soon as possible. You will be advised of your right to file a complaint with the FCC.
3. Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the proper operation of your equipment. If they do, you will be given advance notice so as to give you an opportunity to maintain uninterrupted service.
4. If you experience trouble with this equipment (FXO+), please contact ADTRAN Customer Service for repair/warranty information (see the end of this manual). The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or until you are sure the equipment is not malfunctioning.
5. This unit contains no user serviceable parts.
6. The following information may be required when applying to your local telephone company for switched line facilities:
Service REN/SOC FIC USOC
Loop Start 0.3B/9.0F 02LS2 RJ11C Ground Start 0.1A/9.0F 02GS2 RJ11C
7. The REN and FCC registration number are indicated on the label. The ringer equivalence number (REN) is used to determine how many devices can be connected to your telephone line. In most areas, the sum of the RENs of all devices on any one line should not exceed five (5.0). If too many devices are attached, they may not ring properly.
8. On the circuit board of this equipment is a label that contains, along with other informa­tion, the FCC registration number and ringer equivalence number (REN) for the equip­ment requested. Provide this information to your telephone company.
9. The equipment may not be used on public coin service provided by the telephone company. Connection to party lines is subject to state tariffs.
Table of Contents
AFFIDAVIT REQUIREMENTS FOR CONNECTION TO DIGITAL SERVICES
• An affidavit is required to be given to the telephone company when­ever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voice band analog signals and transmitted on the network.
• The affidavit shall affirm that either no encoded analog content or billing information is being transmitted or that the output of the device meets Part 68 encoded analog content or billing protection specifica­tions.
• End user/customer will be responsible to file an affidavit with the local exchange carrier when connecting unprotected CPE toa 1.544 Mbps or subrate digital services.
• Until such time as subrate digital terminal equipment is registered for voice applications, the affidavit requirement for subrate services is waived.
Table of Contents
AFFIDAVIT FOR CONNECTION OF CUSTOMER PREMISES
EQUIPMENT TO 1.544 MBPS AND/OR SUBRATE DIGITAL SERVICES
For the work to be performed in the certified territory of _______________ (telco name)
State of ________________
County of ________________
I, _____________________________ (name), _____________________
(business address), ____________________ (telephone number) being
duly sworn, state:
I have responsibility for the operation and maintenance of the terminal equipment to be connected to 1.544 Mbps and/or ________ subrate digital services. The terminal equipment to be connected complies with Part 68 of the FCC rules except for the encoded analog content and billing protection specifications. With respect to encoded analog content and billing protection:
( ) I attest that all operations associated with the establishment, maintenance, and adjustment of the digital CPE with respect to analog content and encoded billing protection information continuously complies with Part 68 of the FCC Rules and Regulations.
( ) The digital CPE does not transmit digital signals containing encoded analog content or billing information which is intended to be decoded within the telecom­munications network.
( ) The encoded analog content and billing protection is factory set and is not under the control of the customer.
I attest that the operator(s)/maintainer(s) of the digital CPE responsible for the establishment, maintenance, and adjustment of the encoded analog content and billing information has (have) been trained to perform these functions by success­fully having completed one of the following (check appropriate blocks): ( ) A. A training course provided by the manufacturer/grantee of the equipment used to encode analog signals; or
( ) B. A training course provided by the customer or authorized representative, using training materials and instructions provided by the manufacturer/grantee of the equipment used to encode analog signals; or
Table of Contents
( ) C. An independent training course (e.g., trade school or technical institution) recognized by the manufacturer/grantee of the equipment used to encode analog signals; or
( ) D. In lieu of the preceding training requirements, the operator(s)/maintainer(s) is (are) under the control of a supervisor trained in accordance with _________ (circle one) above.
I agree to provide _________________ (telco's name) with proper documentation to demonstrate compliance with the information as provided in the preceding paragraph, if so requested.
_________________________________Signature
_________________________________Title
_________________________________ Date
Transcribed and sworn to before me
This ________ day of ________, 199___
_________________________________ Notary Public
My commission expires:
_________________________________
Table of Contents
CANADIAN EQUIPMENT LIMITATIONS
The Industry Canada Certification label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company's inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian mainte­nance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic waterpipe system, if present, are connected together. This precaution may be particularly important in rural areas.
Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection author­ity, or an electrician, as appropriate.
The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the equipment that the total of the LNs of all devices does not exceed 100.
The ringer equivalence number (REN) assigned to each terminal adapter is used to determine the total number of devices that may be connected to each circuit. The sum of the RENs from all devices in the circuit should not exceed a total of 5.0.
Table of Contents
Table of Contents
Chapter 1. Introduction ..................................................................................... 1
FXO+ Dual Voice Overview ................................................................................ 1
Functional Description ................................................................................. 2
Features .................................................................................................... 2
FXO+ Option Module Specifications .................................................. 3
Physical Description...................................................................................... 4
Warranty and Customer Service ........................................................................ 5
Chapter 2. Installation ....................................................................................... 7
Unpack and Inspect .............................................................................................. 7
Shipped by ADTRAN ................................................................................... 7
Provided by Customer.................................................................................. 7
Installing The FXO+ Dual Voice Option Module ............................................. 8
Modules With Hot Replaceable Label on Back Panel............................... 8
Modules Without Hot Replaceable Label on Back Panel ......................... 8
Placement of the Option Module ................................................................ 9
Power Connection ......................................................................................... 9
Wiring ........................................................................................................... 10
Power Up Testing and Initialization ................................................................ 11
Successful Self Test ...................................................................................... 11
Failed Self Test ............................................................................................. 11
Operation Alarms ........................................................................................ 11
Chapter 3. Operation ........................................................................................ 13
Overview.............................................................................................................. 13
Menu Structure ............................................................................................ 13
Menu Operation .......................................................................................... 13
FXO+ Menu Items .............................................................................................. 15
Port Status..................................................................................................... 15
2-Wire Status ......................................................................................... 16
View Signaling Bits .............................................................................. 16
Port Config (Port Configuration) .............................................................. 17
Mode ...................................................................................................... 18
RX LVL (TLP) (Receive Level/Transmit Level Point) .................... 19
TX LVL (TLP (Transmit Level/Transmit Level Point) ................... 19
Fault Resp (Fault Response) ............................................................... 19
Port Utility .................................................................................................... 20
Port Test ........................................................................................................ 21
61200.103L2-1 FXO+ Dual Voice Option Module User Manual i
Table of Contents
1 kHz Tone ............................................................................................ 21
VIEW SIG BITS (View Signaling Bits) ............................................... 22
SET TX SIGNAL (Set Transmit Signal) ............................................. 22
SET 2-W OUTPUT (Set 2-Wire Output) ............................................ 22
TSU Features Used With FXO+ Options ......................................................... 23
Factory Restore ............................................................................................ 23
Run Self Test................................................................................................. 23
Appendix A. FXO+ Option Card Menu Tree .............................................. 25
Appendix B. FXO+ Failure Messages ........................................................... 27
Failure Messages at Power-Up ......................................................................... 27
Appendix C. Signaling States ........................................................................ 29
Signaling States versus Mode of Operation ................................................... 29
List of Figures
Figure 1-1 FXO+ Dual Voice Option Module .................................................. 4
Figure 2-1 Installing Option Module ................................................................ 9
Figure 3-1 TSU 100 Main Menu ....................................................................... 14
Figure 3-2 Port Status Submenus .................................................................... 15
Figure 3-3 2-Wire Status Display ..................................................................... 16
Figure 3-4 View Signaling Bits Display .......................................................... 16
Figure 3-5 Port Configuration Submenus ...................................................... 17
Figure 3-6 Port Utility Submenus .................................................................... 20
Figure 3-7 Port Test Submenus ........................................................................ 21
Figure 3-8 View Signaling Bits Display .......................................................... 22
Figure A-1 FXO+ Option Card Menu Tree ..................................................... 25
List of Tables
Table 2-A 2-Wire Voice Pinout Connection .................................................... 10
Table 3-A Port Configuration Parameters ...................................................... 17
Table 3-B Port Test Parameters......................................................................... 22
Table C-A FXO+ Loop Start Mode .................................................................. 29
Table C-B FXO+ Ground Start Mode .............................................................. 30
Table C-C DPT Mode ........................................................................................ 31
ii FXO+ Dual Voice Option Module User Manual 61200.103L2-1
FXO+ DUAL VOICE OVERVIEW
The FXO+ Dual Voice (FXO+) option module is one of the option modules available for use with the ADTRAN TSU 100/120/600. The FXO+ module provides two 2-wire voice-grade interfaces serving as the loop termination for central office line current and ringing voltage.
The FXO+ module emulates a telephone or station interface. It responds to signaling from the digital signal, level 1 (DS1) stream by providing loop closure or ring ground to the 2-wire interface. The condition of tip-ground and ringing on the 2-wire interface is converted to signaling out the DS1 stream. The FXO+ may serve as the office side of a foreign exchange FXO/FXS application. The FXO+ may be used with the ADTRAN FXS+ to implement message-waiting with analog message-waiting phones that need -150 VDC to light the message lamp. The FXO+ module features on-hook data transmission for passing Caller ID data from the 2-wire interface to the DS1 stream. When the FXO+ is used in the dial pulse terminate (DPT) mode with E&M signaling on the DS1 stream, it extends the central office side of an analog direct inward dial (DID) trunk to the customer premises. The FXO+ may be used to connect to the station side of a private branch exchange (PBX). Signaling and interfaces comply with portions of EIA/TIA-464-A
Chapter 1. Introduction
Chapter 1
Introduction
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 1
Chapter 1. Introduction
and AT&T Pub. 43801, and FCC Part 68. The FXO+ option module also accepts the FXO+ plug-on board to provide up to four FXO+ functional ports per option slot used, as well as accepting other plug-on modules.
The FXO+ plug-on module may be plugged onto any existing TSU option module.
Functional Description
The FXO+ is designed to fit in the option slot of the TSU 100/120/600 and is subject to its operation and control. The FXO+ is configured from the front panel of the TSU 100/120/600 or by an external personal computer (PC) program (T-Watch). The internal menus for its configuration are a part of the FXO+ module and are automatically installed when the FXO+ is plugged into the unit.
Features
The FXO+ Dual Voice option module has the follow­ing features:
• Each 2-wire port operates at 64 kbps
• Menu configurable transmit (TX) and receive (RX) levels (transmit level points - TLPs)
• FXO, FXO message waiting, and DPT operating modes
• Passes Caller ID data from the 2-wire interface to the T1
• Ground Start or Loop Start 2-Wire Supervision
• Extensive testing capabilities:
- RX and TX signal bit monitoring
- Busy, ringing, message-waiting, and status
monitoring
- Integral 1 kHz tone generation sends test tone
towards near or far end
- Manual control of TX A and B signal bits
- Manual control of 2-wire interface supervision
output
• Adding the FXO+ plug-on board provides the TSU
2 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
100/120/600 with four voice ports in one option slot
• Selectable 2-Wire output for carrier failure
• Full V.34 modem compatible
• Detects and forwards far-end disconnect signals to ADTRAN FXS+ in FXS mode.
FXO+ Option Module Specifications
The FXO+ Dual Voice option module conforms to the following specifications:
Voice Channels Two (four with plug-on
Transmission Levels TX: +8 to 0 dB TLP, 1 dB
Frequency Response 300 to 3400 Hz (+/- 1.0 dB) 2-wire Impedance 600 + 2.15 µF 2-wire ERL 20 dB 2-wire SRL 15 dB THL ERL >25 dB THL SRL 20 dB Longitudinal Bal >52 dB RX Idle Channel Noise <15 dBrnc TX Idle Channel Noise <20 dB r nc
Chapter 1. Introduction
module installed)
steps RX: 0 to -8 dB TLP, 1 dB steps
Operating Temperature 0° to 45°C, relative humid-
ity, non-condensing
Connector RJ-45
Tests Power-on circuit test
Signal Bits Monitoring and Setting 1 kHz test tone generation Settable 2-wire port output state
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 3
Chapter 1. Introduction
Physical Description
The FXO+ is an option module which plugs into the option slot in the rear of the main unit; see Figure 1-1.
DUAL FXO
T X.1
R
PO
PO
RT X.2
PORT X.3
Figure 1-1
FXO+ Dual Voice Option Module
The FXO+ rear panel includes a plastic plug over a cutout for additional connectors. This allows a plug­on board to be added to the FXO+ module. The PORT X.Y indication is linked to the port numbering philoso­phy of the TSU 100 product family. The X represents the slot number, and the .Y indicates the port number. For the TSU 100 application, there is only one option slot. Therefore the port designations for the two FXO voice ports will be 1.1 and 1.2. If added, the plug-on board port designation would be 1.3 and
1.4. These port numbers appear in the front panel liquid crystal display (LCD) menu displays.
4 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within five years from the date of shipment if the product does not meet its published specifications or if it fails while in service. For detailed warranty, repair, and return information refer to the ADTRAN Equipment Warranty and Repair and Return Policy Procedure.
Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN.
For Service, RMA requests, or more information, contact one of the numbers at the end of this manual.
Chapter 1. Introduction
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 5
Chapter 1. Introduction
6 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
UNPACK AND INSPECT
Carefully inspect the FXO+ Dual Voice option module for any shipping damages. If damage is suspected, file a claim immediately with the carrier and then contact ADTRAN Technical Support. If possible, keep the original shipping container for use in shipping the FXO+ module back for repair or for verification of damage during shipment.
Chapter 2. Installation
Chapter 2
Installation
Shipped by ADTRAN
The following items are included in the ADTRAN shipment:
• FXO+ Dual Voice option module
• User Manual (to be inserted into main TSU 100/ 120/600 user manual)
Provided by Customer
The customer must provide a cable for connection to the station.
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 7
Chapter 2. Installation
INSTALLING THE FXO+ DUAL VOICE OPTION MODULE
For ease of replacement, power to the TSU 100/120/ 600 may be on when installing or removing the FXO+ Dual Voice option module.
For use in Canada, regulatory compliance requires that the Transmit Level/Transmit Level Point, TX LVL (TLP), of the FXO+ Dual Voice option module be set to a value between +3dB and +8dB inclusive, and that the TSU 100/120/600 be password protected to prevent unauthorized alteration of the level.
See the chapter Operations for information on setting the Transmit Level/Transmit Level Point, TX LVL (TLP). See the TSU 100/120/600 user manual for information about password protecting the unit.
8 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
Placement of the Option Module
Figure 2-1 represents the action required for proper placement of the option module.
1. Remove cover plate from the unit rear panel.
2. Slide option module into the rear panel until it is
positioned firmly against the front of the unit.
3. Fasten thumbscrews at both edges of the option
module.
TSU 100/120/600
Chapter 2. Installation
Cover Plate
Option Module
Figure 2-1
Installing Option Module
Power Connection
Each FXO+ module derives power from the base TSU 100/120/600 unit. Power to the TSU 100/120/600 is supplied by a captive eight-foot power cord.
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 9
Chapter 2. Installation
Wiring
PIN NAME DESCRIPTION
The FXO+ Dual Voice option module offers two connectors for an analog voice interface. The connec­tors are universal and accept either an RJ-45 (8-pin) or an RJ-11 (6-pin modular plug). The pinout is given in Table 2-A.
The required wiring connection is as follows:
Connector Type (USOC) RJ-45 Part number AMP # 555164-1
Table 2-A
2-Wire Voice Pinout Connection
5
4
1, 2, 3, 4, 5, 6, 7, 8
TIP
RING
UNUSED
Tip lead of 2-wire interface
Ring lead of 2-wire interface
-
Pins used to mate with the FXO+ connector are as follows:
RJ-11 Tip pin 4
Ring pin 3
RJ-45 Tip pin 5
Ring pin 4
10 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
POWER UP TESTING AND INITIALIZATION
The FXO+ option module executes a partial self test during the power up sequence, as described in the TSU 100/120/600 manual. A full self test can be activated from the Test menu. No initialization input is required. Any previously configured setting for the FXO+ is restored automatically upon power up.
Successful Self Test
The green OK LED, located with the Module LEDs on the front panel, turns on when a successful self test is completed and the configuration is successfully restored. See the chapter Operation in the main user manual.
Failed Self Test
If the FXO+ module fails one or more of the self tests, a message is displayed in the LCD during power up. See the TSU 100/120/600 user manual. Specific failures of the FXO+ module are identified in the appendix FXO+ Failure Messages in this manual.
Chapter 2. Installation
Operation Alarms
The red ALARM LED with the Module LEDs on the front panel turns on when an alarm condition is detected.
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 11
Chapter 2. Installation
12 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
OVERVIEW
Chapter 3. Operation
Chapter 3
Operation
The FXO+ module is controlled as part of the TSU 100/120/600 using the same methods as described in the user manual.
See the TSU 100/120/600 user manual for descriptions of front panel indicators and buttons.
Menu Structure
When an option module is installed in the TSU 100/120/600, the unit adds it to the list of available options under the Port menu items. These menu items are shaded in the limited overview of the TSU 100 menu shown in Figure 3-1. (The appendix of the TSU 100 user manual contains a complete menu diagram.)
Menu Operation
An option module must be selected from the listing in one of the Port menu options before any option module menus are applicable. With the cursor on one of the Port menu items, press Enter to display a list of the currently installed option modules. To activate menus for the FXO+ option module, scroll through the list to display X.1 FXO+ and press Enter. (The X represents the slot number, and .1 identifies the port number.)
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 1
Chapter 3. Operation
Once the option module is selected, the FXO+ menus appear as a subset of, and operate the same as, menus for the main unit. Use the up and down Arrows to place the cursor on the desired item and press Enter to display the first two submenu choices.
TSU 100 MAIN MENU
1)STATUS
2)CONFIG
3)UTIL
4)TEST
1)NETWORK (NI)
2)UNIT
3)MAP XCHNG
4)MAP IN USE A (B)
5)DS0 MAP A
6)DS0 MAP B
7)PORT CONFIG
1)NETWORK TESTS
2)RUN SELF TEST
3)PORT TEST
4)CANCEL TEST
1)NI PERF REPORTS
2)NI ERRORS
3)ACTIVE ALARMS
4)VIEW HISTORY
5)PORT STATUS
6)REMOTE PORT
7)CLEAR PORT ALM
1)TIME/DATE
2)FACTORY RESTORE
3)SET PASSCODE
4)UNIT ID
5)SOFTWARE REV
6)PORT UTILITY
Figure 3-1
TSU 100 Main Menu
2 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
FXO+ MENU ITEMS
The FXO+ menus are accessed from, and operate the same as, menus for the TSU 100/120/600. The FXO+ items are submenu choices of those four Main menus, as shown in Figure 3-1. For information on Factory Restore and Run Self Test see TSU Features Used With FXO+ Options in this chapter.
The FXO+ menu items:
• Port Status
• Port Configuration
• Port Utility
• Port Test
Port Status
Port Status, a submenu of TSU 100/120/600 Main menu item Status, displays active status information about the FXO+ interface.
Chapter 3. Operation
When Port Status is displayed, place the cursor on it and press Enter to display the first available port. Scroll to select 1.1 FXO+ and press Enter to activate either of the submenus shown in Figure 3-2.
1)STATUS
1)NI PERF REPORTS
2)NI ERRORS
3)ACTIVE ALARMS
4)VIEW HISTORY
5)PORT STATUS
6)REMOTE PORT
7)CLEAR PORT ALM
1.1 FXO+
2W STATUS
VIEW SIG BITS
Figure 3-2
Port Status Submenus
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 3
Chapter 3. Operation
2-Wire Status
There are three information fields, Busy, Ringing, and Message-Waiting (MW). See Figure 3-3. An asterisk (*) indicates an item is active.
Figure 3-3
2-Wire Status Display
Busy
An asterisk is present if loop current is flowing through the 2-wire circuit.
Ringing
An asterisk is present if ringing voltage is being applied to the 2-wire input.
MW (Message-Waiting)
An asterisk is present if 150 VDC message-waiting voltage is applied between tip and ring.
View Signaling Bits
View Sig Bits is used to view the status of the RX and TX signaling bits in the DS1 stream. See Figure 3-4. The status of both the A and B bits is displayed.
Figure 3-4
View Signaling Bits Display
4 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
Port Config (Port Configuration)
Port Configuration, a submenu of TSU 100/120/600 main menu item Configuration, is used to configure the FXO+ option module. The submenu items shown in Figure 3-5 are used to configure the parameters.
Chapter 3. Operation
2)CONFIG
7)PORT CONFIG
MENU ITEM PARAMETER CHOICES
MODE
RX LVL (TLP)
TX LVL (TLP)
FAULT RESP
1)MODE
1.2 FXO+
2)RX LVL (TLP)
3)TX LVL (TLP)
4)FAULT RESP
Figure 3-5
Port Configuration Submenus
The unit displays the first of seven submenu items. Table 3-A identifies the available selections for Port Configuration. Continue with standard operating procedures.
Table 3-A
Port Configuration Parameters
FXS-LS, FXO-GS, FXO-LSMW, DPT
--8 dB --> 0 dB, 1 dB steps *(--3 dB)
0 dB -->+8 dB, 1 dB steps *(+3 dB)
*Normal, Seized
*Factory Default
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 5
Chapter 3. Operation
Mode
Mode sets the type of 2-wire to T1 signaling used. Choices include:
FXO_LS (FXO loop-start)
This mode detects the presence of ringing voltage on a 2W analog line with battery. The status of this ringing signal is passed on out the T-span. The FXO+ also provides loop-closure in response to signaling being received on the T-span. The FXO interface looks like a telephone to the analog line that it terminates. Line­current dropout is also detected at the end of a call (disconnect supervision) and is passed to the far-end FXS card.
FXO_GS (FXO ground-start)
This mode is used when interfacing to or extending ground start analog central office trunks. Ringing voltage and tip-ground is detected by this card and passed out the T-span. Incoming signaling on the T-span will determine if ring ground or loop closure is asserted on the 2W interface. Ground start lines are often used with PBX and key systems to reduce the possibility of incoming and outgoing calls on a trunk.
FXO_LSMW (FXO loop-start message waiting; used in ESF framing only)
This mode is the same as FXO_LS with the exception that 150-volt message-waiting voltage is detected and that information is passed out the T-span to the far­end FXS+ card. Message waiting operation allows an analog message-waiting telephone to be placed at a remote location and connected through T-span.
6 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
DPT (dial-pulse terminate)
This mode allows analog DID (direct inward dial) trunk interfaces on a PBX to be interfaced to a T-span. In the DPT mode, the FXO+ card detects battery polarity reversal and passes this information out the T­span. The FXO+ responds to signaling on the T-span by opening or closing the loop. These functions allow incoming calls on the T-span using E&M signaling to be terminated on an analog port using loop-reverse battery signaling.
RX LVL (TLP) (Receive Level/Transmit Level Point)
RX LVL (TLP) sets the RX direction transmission level points (TLP). The TLP is indicated in dB and the relative loudness is indicated by a bar graph display. Settings change immediately as the bar graph is scrolled.
Choice range: –8 dB –> 0 dB, in 1 dB steps.
TX LVL (TLP) (Transmit Level/Transmit Level Point)
Chapter 3. Operation
TX LVL (TLP) sets the TX direction transmission level points (TLPs). The TLP is indicated in dB and the relative loudness is indicated by a bar graph display. Settings change immediately as the bar graph is scrolled.
Choice range: +0 dB –> –8 dB, in 1 dB steps.
Fault Resp (Fault Response)
Fault Response, Normal or Seized, determines the 2­wire output during a carrier alarm. For a network alarm, the 2-wire trunk would appear busy if set for seized. If set for Normal, no seizure occurs.
Choices: Normal and Seized.
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 7
Chapter 3. Operation
Port Utility
1)TIME/DATE
2)FACTORY RESTORE
3)SET PASSCODE
3)UTIL
4)UNIT ID
5)SOFTWARE REV
6)PORT UTILITY
Port Utility, a submenu of the TSU 100/120/600 main menu item Utilities (UTIL) displays the current software information for each port installed in the unit. This information is required when requesting assistance from ADTRAN Technical Support or when updates are needed.
When Port Utility is displayed, place the cursor on it and press Enter to display the first available port. See Figure 3-6.
1)SW REVISION
1.1 FXO+
2)CMD MODE
Figure 3-6
Port Utility Submenus
Display 1.1 FXO+ (scroll to display if necessary), and press Enter. The unit displays the option module name and the software version installed.
The submenu Port Utility contains a second option,
2)CMD Mode, for the FXO+ module. This option is reserved for factory use only.
Press Cancel to exit or select another port.
8 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
Port Test
Chapter 3. Operation
Port Test, a submenu of the TSU 100/120/600 Main menu item Test, activates tests of the selected data ports. Selecting the FXO+ displays tests available for this option module. See Figure 3-7.
4)TEST
1 kHz Tone
1)NETWORK TESTS
2)RUN SELF TEST
3)PORT TEST
4)CANCEL TEST
1.1 FXO+
1)1 KHZ TONE
2)VIEW SIG BITS
3)SET TX SIGNAL
4)SET 2W OUTPUT
Figure 3-7
Port Test Submenus
This test injects a 1004 Hz sine wave either toward the far end (TX DIRECTION toward the T1 network) or toward the near end (the 2-wire interface on the option module). This tone may be used for testing or relative level measurements.
Choices: Off, Near, and Far.
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 9
Chapter 3. Operation
VIEW SIG BITS (View Signaling Bits)
View Sig Bits is used to view the status of the RX and TX signaling bits in the DS1 stream. See Figure 3-8. The status of both the A and B bits is displayed.
SET TX SIGNAL (Set Transmit Signal)
Set TX Signal allows the A and B signal bits in the TX direction to be forced to a desired state for test.
Figure 3-8
View Signaling Bits Display
SET 2-W OUTPUT (Set 2-Wire Output)
Set 2W Output allows the 2-wire voice interface output to be forced to a desired state for test.
Table 3-B
Port Test Parameters
MENU ITEM PARAMETER CHOICES
1 kHz Tone
View Sig Bits
Set TX Signal
Set 2W Output
10 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
Off, Near, Far
Display only
Off, A=0 B=0, A=1 B=0, A=0 B=1, A=1 B=1
Off, Loop Open, Loop Closed, Ring Ground
TSU FEATURES USED WITH FXO+ OPTIONS
In addition to the FXO+ menu items, two additional menu items of the TSU 100/120/600 may be operated in conjunction with the FXO+ option module. These are Factory Restore and Run Self Test.
Factory Restore
Factory Restore, a submenu of the TSU 100/120/600 Main menu item UTIL (Utilities), restores the factory installed default setting for all FXO+ option module parameters.
When Factory Restore is displayed, place the cursor on it and press Enter. The unit is restored to preset factory defaults and returns to the Main menu. The factory default for port configuration parameters is shown in Table 3-A.
Run Self Test
Chapter 3. Operation
Run Self Test, a submenu of the TSU 100/120/600 Main menu item Test, executes both the FXO+ internal test and the TSU 100/120/600 internal test. The results of the self test are displayed in the LCD. See the TSU 100/120/600 user manual for additional information on Self Test.
When Run Self Test is displayed, place the cursor on it and press Enter to execute the test. The unit continu­ously changes the display in the LCD window until all test results are shown.
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 11
Chapter 3. Operation
12 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
Product Support Information
Presales Inquiries and Applications Support
Please contact your local distributor, ADTRAN Applications Engineering, or ADTRAN Sales:
Applications Engineering (800) 615-1176 Sales (800) 827-0807
Post-Sale Support
Please contact your local distributor first. If your local distributor cannot help, please contact ADTRAN Technical Support and have the unit serial number available.
Technical Support (888) 4ADTRAN
Repair and Return
If ADTRAN Technical Support determines that a repair is needed, Technical Support will coordinate with the Return Material Authorization (RMA) department to issue an RMA number. For informa­tion regarding equipment currently in house or possible fees associated with repair, contact RMA directly at the following number:
RMA Department (205) 963-8722
Identify the RMA number clearly on the package (below address), and return to the following address:
ADTRAN, Inc. RMA Department 901 Explorer Boulevard Huntsville, Alabama 35806
RMA # _____________
Appendix A. FXO+ Option Card Menu Tree
Appendix A
FXO+ Option Card Menu Tree
The menu tree for the FXO+ Option Card is provided in Figure A-1.
1)Port Status
2)Port Config
3)Port Utility
4)Port Test
1)2W Status (Busy Ringing)
2)View Sig Bits (RXA RXB TXA TXB)
1)MODE: FXO_LS, FXO_GS, FXO_LSMW, DPT
2)RX LVL (TLP): -8 dBM to 0 dBM
3)TX LVL (TLP): 0 dBM to +8 dBM
4)FAULT RESP: NORMAL, SEIZED
1)SW Revision
2)Command Mode : 0
1)1 KHZ Tone: OFF, NEAR, FAR
2)View Sig Bits (RXA RXB TXA TXB)
3)Set TX Signal: OFF, AB=00, AB=01, AB=10, AB=11
4)Set 2W Output: OFF, LOOP OPEN, LOOP CLOSED, RING GROUND
Figure A-1
FXO+ Option Card Menu Tree
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 25
Appendix A. FXO+ Option Card Menu Tree
26 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
Appendix B. FXO+ Failure Messages
FXO+ Failure Messages
FAILURE MESSAGES AT POWER-UP
The following messages indicate a probable compo­nent failure on the FXO+ Module:
E01 - EPROM CS EPROM checksum error
E02 - RAM ERR Static RAM error
Appendix B
E03 - TIP GND Tip ground detection circuits
E04 - RINGING Ringing detection circuits
E06 - TEST FAIL Self test could not finish
E10 - SIGNALING Failure of signal bit transmission
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 27
Appendix B. FXO+ Failure Messages
28 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
Appendix C. Signaling States
FXO+ FXO+
2W OUTPUT RXA RXB TXA TXB 2W Output
Outgoing call from 2W port
Loop Open 0 X 0 1 No ringing (idle)
Loop Open 0 X 0 0 Ringing
Loop Closed 1 X 0 1 No ringing
Incoming call to 2W port
Loop Open 0 X 0 1 No ringing (idle)
Loop Closed 1 X 0 1 No ringing
Appendix C
Signaling States
SIGNALING STATES VERSUS MODE OF OPERATION
The three tables in this appendix describe the signal­ing states for the FXO card and the DS-1 PCM stream.
FXO+ Loop Start Mode
Table C-A
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 29
The A and B signal bit states on the DS-1 signal are as follows:
0 = logic 0 is the DS-1 stream 1 = logic 1 is the DS-1 stream X = value is not significant Loop Open = telephone on-hook Loop Closed = telephone off-hook
Appendix C. Signaling States
Table C-B
FXO+ Ground Start Mode
FXO+ FXO+
2W OUTPUT RX A RX B TXA TX B 2W INPUT
Outgoing call from 2W port
Loop open, no ring ground 0 1 1 1 No tip ground, no ringing (idle) Loop open, no ring ground 0 1 0 1 Loop closed, no ring ground 1 1 0 1 Loop closed, no ring ground 1 1 0 0
Incoming call to 2W port
Loop open, no ring ground 0 1 1 1 No tip ground, no ringing (idle) Loop open, ring ground 0 0 1 1 No tip ground, no ringing Loop open, ring ground 0 0 0 1 Tip ground, no ringing Loop closed, no ring ground 1 1 0 1 Tip ground, no ringing
Tip ground, no ringing Tip ground, no ringing Tip ground, no ringing
The A and B signal bit states on the DS-1 signal are as follows:
0 = logic 0 is the DS-1 stream 1 = logic 1 is the DS-1 stream X = value is not significant Loop Open = phone on-hook Loop Closed = phone off-hook
See Tables C-B and C-C for descriptions of FXO mode for signaling states.
30 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
Appendix C. Signaling States
Table C-C
DPT Mode
FXS+ FXO+
2W OUTPUT RX A RX B TX A TXB 2W Output
Outgoing call from 2W port
Loop Open
Loop Closed
Loop Open
Loop Open 0/1
Loop Closed
0
1
1
1
The A and B signal bit states on the DS-1 signal are as follows:
0 = logic 0 is the DS-1 stream 1 = logic 1 is the DS-1 stream X = value is not significant Loop Open = telephone on-hook Loop Closed = telephone off-hook
X
X
X
X
X
0
0
1
0
1
0 Normal battery (idle)
0 Normal battery
1 Reverse battery (wink)
0 Normal battery
1 Reverse battery (answer)
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 31
Appendix C. Signaling States
32 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
Loading...