Adtran Dual FXO Module User Manual

FXO+ DUAL VOICE OPTION MODULE
Part Number 1200103L2
&
FXO+ DUAL VOICE PLUG-ON BOARD
Part Number 1200104L2
USER MANUAL
61200.103L2-1B March 1997
Table of Contents
901 Explorer Boulevard
P.O. Box 140000
Huntsville, AL 35814-4000
Phone: (205) 963-8000
All rights reserved.
Printed in U.S.A.
Table of Contents
FEDERAL COMMUNICATIONS COMMISSION
RADIO FREQUENCY INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio frequencies. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Shielded cables must be used with this unit to ensure compliance with Class A FCC limits.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Table of Contents
FEDERAL COMMUNICATIONS COMMISSION (FCC)
INFORMATION
FCC regulations require that the following information be provided to the customer in this manual:
1. This equipment complies with Part 68 of the FCC rules. The required label is affixed to the bottom of the chassis.
2. If your telephone equipment (FXO+) causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance. But if advance notice is not practical, you will be notified as soon as possible. You will be advised of your right to file a complaint with the FCC.
3. Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the proper operation of your equipment. If they do, you will be given advance notice so as to give you an opportunity to maintain uninterrupted service.
4. If you experience trouble with this equipment (FXO+), please contact ADTRAN Customer Service for repair/warranty information (see the end of this manual). The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or until you are sure the equipment is not malfunctioning.
5. This unit contains no user serviceable parts.
6. The following information may be required when applying to your local telephone company for switched line facilities:
Service REN/SOC FIC USOC
Loop Start 0.3B/9.0F 02LS2 RJ11C Ground Start 0.1A/9.0F 02GS2 RJ11C
7. The REN and FCC registration number are indicated on the label. The ringer equivalence number (REN) is used to determine how many devices can be connected to your telephone line. In most areas, the sum of the RENs of all devices on any one line should not exceed five (5.0). If too many devices are attached, they may not ring properly.
8. On the circuit board of this equipment is a label that contains, along with other informa­tion, the FCC registration number and ringer equivalence number (REN) for the equip­ment requested. Provide this information to your telephone company.
9. The equipment may not be used on public coin service provided by the telephone company. Connection to party lines is subject to state tariffs.
Table of Contents
AFFIDAVIT REQUIREMENTS FOR CONNECTION TO DIGITAL SERVICES
• An affidavit is required to be given to the telephone company when­ever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voice band analog signals and transmitted on the network.
• The affidavit shall affirm that either no encoded analog content or billing information is being transmitted or that the output of the device meets Part 68 encoded analog content or billing protection specifica­tions.
• End user/customer will be responsible to file an affidavit with the local exchange carrier when connecting unprotected CPE toa 1.544 Mbps or subrate digital services.
• Until such time as subrate digital terminal equipment is registered for voice applications, the affidavit requirement for subrate services is waived.
Table of Contents
AFFIDAVIT FOR CONNECTION OF CUSTOMER PREMISES
EQUIPMENT TO 1.544 MBPS AND/OR SUBRATE DIGITAL SERVICES
For the work to be performed in the certified territory of _______________ (telco name)
State of ________________
County of ________________
I, _____________________________ (name), _____________________
(business address), ____________________ (telephone number) being
duly sworn, state:
I have responsibility for the operation and maintenance of the terminal equipment to be connected to 1.544 Mbps and/or ________ subrate digital services. The terminal equipment to be connected complies with Part 68 of the FCC rules except for the encoded analog content and billing protection specifications. With respect to encoded analog content and billing protection:
( ) I attest that all operations associated with the establishment, maintenance, and adjustment of the digital CPE with respect to analog content and encoded billing protection information continuously complies with Part 68 of the FCC Rules and Regulations.
( ) The digital CPE does not transmit digital signals containing encoded analog content or billing information which is intended to be decoded within the telecom­munications network.
( ) The encoded analog content and billing protection is factory set and is not under the control of the customer.
I attest that the operator(s)/maintainer(s) of the digital CPE responsible for the establishment, maintenance, and adjustment of the encoded analog content and billing information has (have) been trained to perform these functions by success­fully having completed one of the following (check appropriate blocks): ( ) A. A training course provided by the manufacturer/grantee of the equipment used to encode analog signals; or
( ) B. A training course provided by the customer or authorized representative, using training materials and instructions provided by the manufacturer/grantee of the equipment used to encode analog signals; or
Table of Contents
( ) C. An independent training course (e.g., trade school or technical institution) recognized by the manufacturer/grantee of the equipment used to encode analog signals; or
( ) D. In lieu of the preceding training requirements, the operator(s)/maintainer(s) is (are) under the control of a supervisor trained in accordance with _________ (circle one) above.
I agree to provide _________________ (telco's name) with proper documentation to demonstrate compliance with the information as provided in the preceding paragraph, if so requested.
_________________________________Signature
_________________________________Title
_________________________________ Date
Transcribed and sworn to before me
This ________ day of ________, 199___
_________________________________ Notary Public
My commission expires:
_________________________________
Table of Contents
CANADIAN EQUIPMENT LIMITATIONS
The Industry Canada Certification label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company's inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian mainte­nance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic waterpipe system, if present, are connected together. This precaution may be particularly important in rural areas.
Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection author­ity, or an electrician, as appropriate.
The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the equipment that the total of the LNs of all devices does not exceed 100.
The ringer equivalence number (REN) assigned to each terminal adapter is used to determine the total number of devices that may be connected to each circuit. The sum of the RENs from all devices in the circuit should not exceed a total of 5.0.
Table of Contents
Table of Contents
Chapter 1. Introduction ..................................................................................... 1
FXO+ Dual Voice Overview ................................................................................ 1
Functional Description ................................................................................. 2
Features .................................................................................................... 2
FXO+ Option Module Specifications .................................................. 3
Physical Description...................................................................................... 4
Warranty and Customer Service ........................................................................ 5
Chapter 2. Installation ....................................................................................... 7
Unpack and Inspect .............................................................................................. 7
Shipped by ADTRAN ................................................................................... 7
Provided by Customer.................................................................................. 7
Installing The FXO+ Dual Voice Option Module ............................................. 8
Modules With Hot Replaceable Label on Back Panel............................... 8
Modules Without Hot Replaceable Label on Back Panel ......................... 8
Placement of the Option Module ................................................................ 9
Power Connection ......................................................................................... 9
Wiring ........................................................................................................... 10
Power Up Testing and Initialization ................................................................ 11
Successful Self Test ...................................................................................... 11
Failed Self Test ............................................................................................. 11
Operation Alarms ........................................................................................ 11
Chapter 3. Operation ........................................................................................ 13
Overview.............................................................................................................. 13
Menu Structure ............................................................................................ 13
Menu Operation .......................................................................................... 13
FXO+ Menu Items .............................................................................................. 15
Port Status..................................................................................................... 15
2-Wire Status ......................................................................................... 16
View Signaling Bits .............................................................................. 16
Port Config (Port Configuration) .............................................................. 17
Mode ...................................................................................................... 18
RX LVL (TLP) (Receive Level/Transmit Level Point) .................... 19
TX LVL (TLP (Transmit Level/Transmit Level Point) ................... 19
Fault Resp (Fault Response) ............................................................... 19
Port Utility .................................................................................................... 20
Port Test ........................................................................................................ 21
61200.103L2-1 FXO+ Dual Voice Option Module User Manual i
Table of Contents
1 kHz Tone ............................................................................................ 21
VIEW SIG BITS (View Signaling Bits) ............................................... 22
SET TX SIGNAL (Set Transmit Signal) ............................................. 22
SET 2-W OUTPUT (Set 2-Wire Output) ............................................ 22
TSU Features Used With FXO+ Options ......................................................... 23
Factory Restore ............................................................................................ 23
Run Self Test................................................................................................. 23
Appendix A. FXO+ Option Card Menu Tree .............................................. 25
Appendix B. FXO+ Failure Messages ........................................................... 27
Failure Messages at Power-Up ......................................................................... 27
Appendix C. Signaling States ........................................................................ 29
Signaling States versus Mode of Operation ................................................... 29
List of Figures
Figure 1-1 FXO+ Dual Voice Option Module .................................................. 4
Figure 2-1 Installing Option Module ................................................................ 9
Figure 3-1 TSU 100 Main Menu ....................................................................... 14
Figure 3-2 Port Status Submenus .................................................................... 15
Figure 3-3 2-Wire Status Display ..................................................................... 16
Figure 3-4 View Signaling Bits Display .......................................................... 16
Figure 3-5 Port Configuration Submenus ...................................................... 17
Figure 3-6 Port Utility Submenus .................................................................... 20
Figure 3-7 Port Test Submenus ........................................................................ 21
Figure 3-8 View Signaling Bits Display .......................................................... 22
Figure A-1 FXO+ Option Card Menu Tree ..................................................... 25
List of Tables
Table 2-A 2-Wire Voice Pinout Connection .................................................... 10
Table 3-A Port Configuration Parameters ...................................................... 17
Table 3-B Port Test Parameters......................................................................... 22
Table C-A FXO+ Loop Start Mode .................................................................. 29
Table C-B FXO+ Ground Start Mode .............................................................. 30
Table C-C DPT Mode ........................................................................................ 31
ii FXO+ Dual Voice Option Module User Manual 61200.103L2-1
FXO+ DUAL VOICE OVERVIEW
The FXO+ Dual Voice (FXO+) option module is one of the option modules available for use with the ADTRAN TSU 100/120/600. The FXO+ module provides two 2-wire voice-grade interfaces serving as the loop termination for central office line current and ringing voltage.
The FXO+ module emulates a telephone or station interface. It responds to signaling from the digital signal, level 1 (DS1) stream by providing loop closure or ring ground to the 2-wire interface. The condition of tip-ground and ringing on the 2-wire interface is converted to signaling out the DS1 stream. The FXO+ may serve as the office side of a foreign exchange FXO/FXS application. The FXO+ may be used with the ADTRAN FXS+ to implement message-waiting with analog message-waiting phones that need -150 VDC to light the message lamp. The FXO+ module features on-hook data transmission for passing Caller ID data from the 2-wire interface to the DS1 stream. When the FXO+ is used in the dial pulse terminate (DPT) mode with E&M signaling on the DS1 stream, it extends the central office side of an analog direct inward dial (DID) trunk to the customer premises. The FXO+ may be used to connect to the station side of a private branch exchange (PBX). Signaling and interfaces comply with portions of EIA/TIA-464-A
Chapter 1. Introduction
Chapter 1
Introduction
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 1
Chapter 1. Introduction
and AT&T Pub. 43801, and FCC Part 68. The FXO+ option module also accepts the FXO+ plug-on board to provide up to four FXO+ functional ports per option slot used, as well as accepting other plug-on modules.
The FXO+ plug-on module may be plugged onto any existing TSU option module.
Functional Description
The FXO+ is designed to fit in the option slot of the TSU 100/120/600 and is subject to its operation and control. The FXO+ is configured from the front panel of the TSU 100/120/600 or by an external personal computer (PC) program (T-Watch). The internal menus for its configuration are a part of the FXO+ module and are automatically installed when the FXO+ is plugged into the unit.
Features
The FXO+ Dual Voice option module has the follow­ing features:
• Each 2-wire port operates at 64 kbps
• Menu configurable transmit (TX) and receive (RX) levels (transmit level points - TLPs)
• FXO, FXO message waiting, and DPT operating modes
• Passes Caller ID data from the 2-wire interface to the T1
• Ground Start or Loop Start 2-Wire Supervision
• Extensive testing capabilities:
- RX and TX signal bit monitoring
- Busy, ringing, message-waiting, and status
monitoring
- Integral 1 kHz tone generation sends test tone
towards near or far end
- Manual control of TX A and B signal bits
- Manual control of 2-wire interface supervision
output
• Adding the FXO+ plug-on board provides the TSU
2 FXO+ Dual Voice Option Module User Manual 61200.103L2-1
100/120/600 with four voice ports in one option slot
• Selectable 2-Wire output for carrier failure
• Full V.34 modem compatible
• Detects and forwards far-end disconnect signals to ADTRAN FXS+ in FXS mode.
FXO+ Option Module Specifications
The FXO+ Dual Voice option module conforms to the following specifications:
Voice Channels Two (four with plug-on
Transmission Levels TX: +8 to 0 dB TLP, 1 dB
Frequency Response 300 to 3400 Hz (+/- 1.0 dB) 2-wire Impedance 600 + 2.15 µF 2-wire ERL 20 dB 2-wire SRL 15 dB THL ERL >25 dB THL SRL 20 dB Longitudinal Bal >52 dB RX Idle Channel Noise <15 dBrnc TX Idle Channel Noise <20 dB r nc
Chapter 1. Introduction
module installed)
steps RX: 0 to -8 dB TLP, 1 dB steps
Operating Temperature 0° to 45°C, relative humid-
ity, non-condensing
Connector RJ-45
Tests Power-on circuit test
Signal Bits Monitoring and Setting 1 kHz test tone generation Settable 2-wire port output state
61200.103L2-1 FXO+ Dual Voice Option Module User Manual 3
Loading...
+ 30 hidden pages