RD-60
Integrated MultiCODEC Receiver/Decoder
Thank you for your purchase of the Adtec RD-60 Receiver/Decoder. This
product is sold with optional demodulator hardware packages. Configurations and
indicators relevant to those add-on package are noted here. If you purchased this
product without a demodulator, please disreguard settings noted with an asterisks.
Quick View Status
For information on the core systems of the IRD, use
the down arrorw on the front panel to scroll through
these quick view menus.
Decoder Activity TMR Encryption
DECODING ASI TMR:20.000M CAS:Free to Air
SVC: 00001 “Serv. Name” “Serv. Provider”
Service ID Service Name Service Provider
CODEC Chroma Bit Depth Delay Mode
COD: H.264 CHR: 422 BITD:08 DLYM: NORMAL
VRT: 18.012Mb/s RES:1920X1080 FR:59i
Video Rate Resolution Frame Rate
Video PID PCR PID PMT PID Aspect Ratio
VID:441 PCR:441 PMT:440 ARA:16X9
Audio 1-8
Type Bitrate
1:MU 384k 2:MU 384k 3:MU 384k 4:MU 384k
5:MU 384k 6:MU 384k 7:MU 384k 8:MU 384k
Audio PIDS 1- 8
Audio 1:11300 2:11400 3:11500 4:11600
PIDS 5:11300 6:11400 7:11500 8:11600
Input Mode/FEC Rcv Level Link Margin
RF1 32APSK9/10 Lvl: -52.0dB LMar:20.5dB
Locked DVB-S2 Sym:29.970Ms Eb/No:29.8dB
Lock Status Type Symbol Rate Eb(s)/No
RTP Detected RTP Error Count Buer
RTP: Y RTP-Err: 1234567 Buer:1234ms
FEC: Y FecLoss: 1234567 FecCorr: 1234567
FEC Detected FEC Packet Loss FEC Corrections
Reset:
Should you need to reset your device, you can do
so via the front panel by pressing the MODE,
ESCAPE and RIGHT ARROW keys simultaneously.
LED Status
Decode
Off - Decoder is idle
On - Decoder is active
ASI/IP/RF
Off - No services detected
On - Services detected
Lock 1 / Lock 2
Off - Tuner is not locked
On - Tuner is locked
IP Out
Off - Not functional
On - Not functional
Bars
Off - B/T/ID options are disabled
On - B/T/ID are enabled
A1 - A8
Off - No Audio Decoding
On - Audio Decoding
Blinking - Fail to decode or pass
audio
Alarm
Off - No system alarms
ASI
A2
IP
MultiCODEC
Receiver / Decoder
A3
On - System alarm
BISS
Off - Decryption config is OFF
On - Decryption config is ON
Busy
Off - No network activity
On - Network traffic present
Link
Off - No network detected
On - Connection active
Decode
RD-60
A1
Quick Start Guide
Services
ASI RF1 RF2 IP
Select Service
Select First
The two Gain settings
only apply to RD60-PRM
units manufactured prior
to 03/12 with special
rmware. Units
manufactured after this
date handle these
setting automatically.
RF Rx*
PRM & ADV
Select Tuner
Local Oscillator
Manual LO
Downlink
L-Band
Mod. Type
CCM Mode
Mod. Mode
Symbol Rate
Acquisition Range
Roll O
Pilot
Fec Frame Type
RF Gain
BB Gain (PRM Only)
(PRM Only)
LNB Menu
RF Rx*
LB
<< RF1 - RF2 >>
Tuner State
Downlink
Local Oscillator
Manual LO
L-Band
Acqusition Range
S2X Rollo
LNB Polarity
LNB Tone
Modulation Type
Symbol Rate
ISI
RF Stats
Front Panel Menus:
Use Mode Button to move
MODE
through top layer menus.
Use arrows for navigation
in submenus.
RF
Lock 1
Lock 2
IP Out
Bars
Alarm BISS
Busy
Link
A8
A7
A6
A5
A4
DECODING ASI TMR:20.000M CAS:Free to Air
SVC: 00001 “Service Name” Service Provider
Use select to enter into edit
SELECT
mode and enter to
save selection.
RF Rx*
STD
<< RF1 - RF2 >>
Tuner Active
Local Oscillator
Manual LO
Downlink
L-Band
Mod. Type
Mod. Mode
Symbol Rate
Aquisition Range
Roll O
Pilot
LNB State
LNB Polarity
LNB Tone
ENTER
IP Rx
Rx IP
Rx Port
SSM Address
Video
Output Menu
Genlock Menu
Audio Assign Order
Audio Sync Mode
<< AUDIO 1-8 >>
Connector
Latency
Time Out
Error Rec.
Dolby E Line
Dolby D Mode
ANALOG VOL.
(Audio 1-2 only)
Units ship with the front panel
logged in by default. If you become
logged out and are prompted for a
password, use the following key
sequence for access.
Press <Select> when panel displays
‘User Login -- logged out’
Press <Up arrow>
Press <Select>
Press <Enter>
Press <Right arrow>
Press <Enter>
Audio
Audio PID
Oset
SDI Matrix
SELECT
ENTER
VBI
TimeCode Menu
AFD Menu
CC Menu
Teletext Menu
CAS
Mode
Clear SW
Encrypt. SW
User ID 1
User ID 2
TS Out Decrypt
System
Login
Duration
Backlight
Network Menu
Time Menu
NTP Menu
Alarm Menu
SNMP Menu
COM2
Name
Firmware
Feature Menu
Model Indicators:
Premium demodulator (PRM)
Advanced demodulator (ADV)
L-Band demdulator (LB)
Standard demodulator (STD)
No demodulator
Special Keys:
Use the F2 button as a decimal.
F2
3def
2abc
MODE
ESCAPE
1
4ghi
7pqrs
F1
5jkl
8tuv
6mno
9wxyz
F2
0
Adtec Digital US Sales +1-615-256-6619 International Sales +1-904-394-0389 www.adtecdigital.com 2015 Adtec Digital
Getting Connected
To begin, you will need to connect to your RD-60 via ethernet
directly, or by adding the RD-60 to your local area network.The default
address for all Adtec devices is 192.168.10.48.
To connect directly to the device, make sure that your computer
and the device have IP addresses within the same IP class range (ex.
192.168.10.48 for the device and 192.168.10.49 for your computer).
If you need to change the IP address of the device, this can be done via
the front panel, System > Network menu. Using a CAT 5 crossover
cable, connect one end to your computer and the other to the Ethernet
port found on the processor section of the back panel. (Some computers
can auto negotiate the connection and a crossover may not be
necessary.)
To add the device to a LAN, connect a standard Ethernet cable to
your network router and then to the Ethernet port on the back of the
device. If your network is DHCP enabled and you prefer that over a
static IP, you can turn on DHCP for the device via the front panel,
System > Network menu.
Web-Based Control Application
Adtec Digital has adopted
zero-conguration networking
technology, streamlining the setup and
conguration processes for our products.
The use of this technology enables
automatic discovery of Adtec devices and
services on an IP network. Used in tandem
with the web-based control and
conguration applications we can now
provide 1-click access to any device.
By using the built-in Bonjour
Apple's
readily available for IE
©
Safari© browser or the plug-ins
©
or Firefox©
©
locater in
browsers, users can locate all of the Adtec
devices on a network by referencing the
serial number on the back of the device. Clicking on the unit in the Bonjour
©
list will re-route you to a
login page. If you do not wish to use Bonjour, you can reach the device’s web application by pointing
your browser to the IP Address of the device. Ex. http://192.168.10.48/. You will be prompted for a
username and password. The default username is ‘adtec’. The default password is ‘none’.
The left-hand panel of the application will report current status in real-time while the right
panel tabs will allow you to congure your device.
Have questions? Each field or group of fields in
our web-based application has a hint button associate
?
with it. It contains information on use of the field or
acceptable ranges.
Getting Started
Once your receiver is powered up, configured on
your network and you have inputs applied with active
services, you can select which services you want to
decode via the web-based control application. The below
image shows the Input > RD Services tab. From this tab,
you can view all services available on your device, select
one of the services for decode or view more details about
the service. There is a ‘Select First Found’ option for each
input. When selected, this configuration will detect the
first service detected in the PAT table of the input and
decode it.
Power .....................................................................................................................................
Power: 1 & 2 Redundant AC Power, Standard 3 pin computer power plug
(Auto range 70-240 VAC Input)
Processor ..............................................................................................................................
GigE: MPEG2 or RTP multicast transport ingress port. Current Contraints: 1 - 100 Mbps
COM2: API Serial Communication Interface
COM1: Serial Port Used for Troubleshooting (Terminal)
Ethernet: 10/100 base T ethernet interface (Monitoring/Management)
RS422: Not Currently Supported
Parport: 9-pin parallel I/O interface for control systems
GPIO: Tally and Control Port
Decoder .............................................................................................................................
Analog Audio Out: Balanced analog audio out. Stereo pairs 1 & 2
AES Audio Out 1-4: 75 Ohm AES-3 BNC
ASI In: 75 Ohm BNC
DVB-ASI x3 Out: 75 Ohm BNC
DVB-ASI In: 75 Ohm terminated. ASI Transport Stream Input
Sync In: Standard analog video sync separation for NTSC, PAL, 480I/P, 576I/P, 720P, and 1080I/P/PsF from
Composite Video (CVBS). Bi-level & tri-level sync compatible. BNC
CVBS Out: 75 Ohm Standard Denition Composite Video Output BNC
SDI Out Banks: (2) 75 Ohm Outputs from decoder: Video/Audio/VBI (SMPTE 259M-C - SD & SMPTE 292M - HD) BNC
Demodulator (optional)*......................................................................................................................
RF 1 & 2: RF input, 75 Ohm F-Connector
Advanced (ADV) Model: Supports L-Band, DVB-S/S2, QPSK, 8PSK, 16APSK.
L-Band (LB) Model: Supports L-Band, DVB-S/S2, QPSK, 8PSK, 16APSK, 32APSK.
Premium (PRM) Model: Supports L-Band, DVB-S/S2, QPSK, 8PSK, 16APSK, 32APSK.
Standard (STD) Model: Supports L-Band, DVB-S/S2, QPSK, 8PSK 1-30 Mbaud.
Demodulator notes: Field upgradable demodulator keys are required to unlock full capability such as 16/32APSK. The STD demodulator has been discontinued.
Power
1
Demodulator
2
RF 1
RF 2
GigE
COM2
GPIO
COM1
Ethernet
DVC
Parport
Processor
RS422
ASI Out X 3
Analog
Audio 1
DVB
ASI In
Analog
Audio 2
AES Audio
In 1-4
Note: IP service selection is treated differently than ASI or RF
inputs. To populate the IP services section, you need to first
Sync In
CVBS Out
SDI Out
1 & 2
SDI Out
1 & 2
Decoder
visit the IP Params tab and set the correct Multicast RX, port
and handling parameters. Return to the RD Services tab. Click
the ‘Select First Found’ radio button for IP. This will populate
the RD Services tab with services found on the IP input.
The most recent firmware releases are available on our
support website, www.adtecdigital.com. Advanced users can
find direct API command help as part of the on-board web
application, Help Tab.
Adtec Digital Technical Support: 615.256.6619 www.adtecdigital.com FW: 1.13.XX March 2015