specications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby dis­claim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent as­sembly, installation, rigging, and operation of this product.
4/15
User Instructions
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC) Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Vizi Beam 5RX
Table of Contents
Unpacking......................................................................3
Introduction....................................................................3
Customer Support......................................................................3
Safety Precautions......................................................................4
Features.........................................................................5
Handling Precautions..................................................................6
Registration......................................................................6
Important Discharge Lamp Warnings.........................................7
Mounting.........................................................................8-9
DMX Set-Up.........................................................................10-12
System Menu.......................................................................13-17
DMX Control..............................................................................17
Oset Menu.........................................................................18-20
DMX Traits............................................................................21-34
Fuse Replacement....................................................................35
Lamp Replacement..............................................................35-37
Photometric Chart.....................................................................35
Cleaning..................................................................39
Trouble Shooting.......................................................................39
Warranty.........................................................................40
Specifications....................................................................42
Vizi Beam 5RX General Information
Unpacking: Thank you for purchasing the Vizi Beam 5RX by ADJ
Products, LLC®. Every Vizi Beam 5RX has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all equipment necessary to operate the unit has arrived intact. In the event damage has been found or parts are missing, please contact our toll free customer support number for fur­ther instructions. Please do not return this unit to your dealer without contacting customer support rst.
Introduction: The Vizi Beam 5RX is a DMX intelligent, moving head
fixture. The Vizi Beam 5RX can be a 16 channel or 19 channel DMX unit. The fixture is a DMX controlled unit. The Vizi Beam 5RX is a stand alone unit. For best results use fog or special effects smoke to enhance
the beams projections.
During the initial start-up or use of this product a light smoke or smell may arise from the unit. This is a normal process and is cause by the heat associated with the lamp.
Customer Support: ADJ Products, LLC® provides a toll free cus-
tomer support line, to provide help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacic Standard Time. Voice: (800) 322-6337 Fax: (323) 582-2610 E-mail: support@americandj.com
To purchase parts online visit http://parts.americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
Please see page 7 for important lamp instructions!
ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 2 ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 3
Vizi Beam 5RX Safety Precautions
Vizi Beam 5RX Features
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required volt­ age for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out­ doors voids all warranties.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience recep­ tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 39 for cleaning details.
• Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. Objects have fallen, or liquid has been spilled into the appliance. B. The appliance has been exposed to rain or water. C. The appliance does not appear to operate normally or exhibits a
marked change in performance.
• Philips® Platinum 5R Discharge
• Micro-Stepping Motors for Smooth Color and Gobo Transitions
• 2 Modes of DMX-512 Protocol Compatible (16 DMX Channel Mode or 19 DMX Channel Mode)
• Independent Gobo and Color Wheels
• 17 Static Fixed Gobos + Spot
• 14 Colors, Plus White and Split Colors
• 8 Facet Prism
• Frost Filter
• Strobe Effect
• Built-In Pan/Tilt Macros
• Motorized Focus
• 540˚ Pan Movement
• 270˚ Tilt Movement
• Pan/Tilt Invert
• Digital Display for Address and Function Setting
• Power Cord Daisy Chain (See below)
Vizi Beam 5RX Power Cord Daisy Chain
With this feature you can connect the xtures to one another
using the PowerCon input and output sockets. The quantity
that can be connected is 3 xtures maximum for 120V and 6 x­tures maximum for 240V. After the maximum xtures has been
reached you will need to use a new power outlet. They must be
the same xtures. DO NOT mix xtures.
ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 4 ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 5
Vizi Beam 5RX General Instructions
Vizi Beam 5RX Important Discharge Lamp Warning
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regard­ing the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
Vizi Beam 5RX Handling Precautions
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ®.
During operation the housing may become extremely hot. Avoid touch­ing the unit with bare hands while in use.
ADJ® will not accept any liability for any resulting damages caused by
the non-observance of this manual or any unauthorized modication
to this unit.
Vizi Beam 5RX Product
The Vizi Beam 5RX carries a one year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre­paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper and included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by con­tacting our customer support team on our toll free customer support number. All packages returned to the service department not display­ing a R.A. number on the outside of the package will be returned to
the shipper at the shippers cost.
Registration
This fixture is fitted with a discharge lamp which is highly susceptible to damage if improperly handled. Never touch the lamp with your bare fingers as the oil from your hands will shorten lamp life. Also, never move the fixture until the lamps have had ample time to cool. Remember, lamps are not covered under war-
ranty conditions.
This unit emits intense UV radiation which is harmful to the eyes and skin. The intense luminance of the lamp can cause severe damage to the retina. Never operate this unit without it’s covers, these covers have been specially designed to shield against UV radiation.
Epileptic Warning: Those suering from epilepsy should avoid looking directly
into the lamp at all times.
Avoid switching the xture on and o repeatedly in short intervals as this will reduce lamp life and intensity.
To achieve the intensity associated with discharge lamps, these lamps use gas sealed in a high pressure environment to emit a brilliant output. Due to the high pressure involved with the construction of the lamp, the lamp may explode during prolonged extensive use. This risk is increased with age, added care is encouraged when dealing with older lamps. Extreme caution should be used when operating this or any xture tted with a gas discharge lamp. Never open this unit while in use.
VERY IMPORTANT: This is for your safety and the life length of the unit.
The Philips® Platinum 5R Discharge lamp has lifetime of 3000 hours.
ADJ recommends periodically checking the lamp running time. When the lamp reaches the 3000 hour mark, or close to it, we strongly suggest you switch the lamp out.
Replace the lamp following the instructions on pages 35-38. After replaceing the lamp you must clear the LAMP RUNNING TIME (see page 15 “FHRS”).
Warning: DO NOT use this lamp more then 3000 hours. Using the lamp
any longer then the set life could seriously damage your unit.
ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 6
ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 7
Vizi Beam 5RX Mounting
Vizi Beam 5RX Mounting
When installing the unit, the trussing or area of installation must be able to hold 10 times the weight without any deformation. When installing the unit must be secured with a secondary safety attach­ment, e.g. and appropriate safety cable. Never stand directly below the unit when mounting, removing, or servicing the unit.
Overhead mounting requires extensive experience, including calculat­ing working load limits, installation material being used, and perodic safety inspection of all installation material and unit. If you lack these qualications, do not attempt the installation yourself.
These installaiton should be checked by a skilled person once a year.
NOTICE: The suitable enviromental temperature for this light­ing xture is between -25˚ C to 45˚ C. Do not place this lighting xture in an enviroment where the temperatures are under or above the temperatures stated above. This will allow the xture to run at its best and help prolong the xture life.
The Vizi Beam 5RX is fully operational in two dierent mounting posi­tions, hanging upside-down from a ceiling or set on a at level sur-
face. To avoid internal damage to the unit, never mount the unit on its side as illustrated above. Be sure this xture is kept at least
0.5m away from any ammable materials (decoration etc.). Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails (see next page). Never use the carrying handles for secondary attach-
ment.
ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 8
Screw one clamp each via a M12 screw and nut onto the Omega holders. Insert the quick-lock fasteners of the rst Omega holder into the respective holes on the bottom of the Vizi Beam 5RX. Tighten the quick-lock fasteners fully clockwise. Install the second Omega holder. Pull the safety-cable through the openings located on the base plate and over the trussing system or a safe xation spot. Insert the end in the carabine and tighten the safety screw.
ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 9
Vizi Beam 5RX Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
and PIN 3 (DMX +) of the last fixture.
Vizi Beam 5RX Set Up
Power Supply: The ADJ® Vizi Beam 5RX contains a electronic bal-
last, which will auto sense the voltage when it is plugged into the power source. With the electronic ballast you do not need to worry about wall voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix­ture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. Therefore, the first fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): The Vizi Beam 5RX can be controlled via DMX-512 pro-
tocol. The Vizi Beam 5RX can be either a 16 or 19 channel DMX unit. The DMX address is set electronically using the controls on the side panel of the unit. Your unit and your DMX control­ler require a approved DMX-512 110 Ohm Data cable for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all professional sound and lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also
ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 10 ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 11
Figure 1
remember that DMX cable must be daisy chained and cannot be split.
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con­nect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
When longer runs of cable are
Figure 4
XLR Male Socket
1 Ground
DMX512 OUT
3-PIN XLR
2 Cold
3 Hot
1
2
3
2 Cold
DMX +
DMX -
XLR Female Socket
1 Ground
3 Hot
Figure 3
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-)
Vizi Beam 5RX Set Up Vizi Beam 5RX System Menu
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin DMX-
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting stan­dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Pin 4 - Do Not Use
Pin 5 - Do Not Use
ADJ Products, LLC - www.adj.com - Vizi Beam 5RX Instruction Manual Page 12