ADJ VioSCAN LED Operation Manual

VioSCAN LED General Information
Unpacking: Thank you for purchasing the VioSCAN LED by Ameri-
can DJ®. Every VioSCAN LED has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the ship­ping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all equipment necessary to operate the unit has arrived intact. In the event damage has been found or parts are miss­ing, please contact our toll free customer support number for further instructions. Please do not return this unit to your dealer without con­tacting customer support rst.
Introduction: The VioSCAN LED bright, compact, DMX intelligent
LED scanner. The unit has 2 DMX channel modes; a 1 channel mode and 5 channel mode. The VioSCAN LED has three operating modes; sound active mode, show mode, & DMX controlled. The fixture can operate as stand alone unit or in a Master/Slave configuration. The VioSCAN LED comes with several built in programs. For best results
use fog or special effects smoke to enhance the beams projections.
Customer Support: American DJ® provides a toll free customer
support line, to provide help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.americandj.com for any comments or suggestions. Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacic Standard Time. Voice: (800) 322-6337 Fax: (323) 582-2941 E-mail: support@americandj.com
To purchase parts online visit http://parts.americandj.com
10/10
User Instructions
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
American DJ® - www.americandj.com - VioSCAN LED Instruction Manual Page 2
VioSCAN LED General Instructions
VioSCAN LED Safety Precautions
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
VioSCAN LED Features
• 2 DMX Channel Modes; 1 Channel Mode & 5 Channel Mode
• Auto Sensing Voltage
• 3 Operating Modes - Sound Active, Show Mode, and DMX Control
• Internal Microphone
• Digital Display for Address and Function Setting
• UC3 Controller (Not Included)
VioSCAN LED Warranty Registration
The VioSCAN LED carries a 3 year (1095 days) limited warranty (U.S. Only). Please fill out the enclosed warranty card to validate your pur­chase and warranty. You may also register your product online at www. americandj.com. All returned service items whether under war­ranty or not, must be freight pre-paid and accompany a return autho­rization (R.A.) number. If the unit is under warranty you must provide a copy of your proof of purchase invoice. Please contact American DJ® customer support for a R.A. number.
VioSCAN LED Handling Precautions
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war­ranty. In the unlikely event your unit may require service please contact American DJ®.
During operation the housing may become extremely hot. Avoid touch­ing the unit with bare hands while in use.
American DJ® will not accept any liability for any resulting damages caused by the non-observance of this manual or any unauthorized modication to this unit.
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required volt­ age for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out­ doors voids all warranties.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience recep­ tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 17 for cleaning details.
• Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. Objects have fallen, or liquid has been spilled into the appliance. B. The appliance has been exposed to rain or water. C. The appliance does not appear to operate normally or exhibits a marked change in performance.
American DJ® - www.americandj.com - VioSCAN LED Instruction Manual Page 4American DJ® - www.americandj.com - VioSCAN LED Instruction Manual Page 3
VioSCAN LED Set Up
DMX512 IN
3-PIN XLR
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
VioSCAN LED Set Up
Power Supply: The American DJ® VioSCAN LED contains a elec-
tronic ballast, which will auto sense the voltage when it is plugged into the power source. With the electronic ballast you do not need to worry about wall voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix­ture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using
several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. Therefore, the first fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): The VioSCAN LED can be controlled via DMX-512 proto-
col. The VioSCAN LED has 2 DMX channel modes; a 1 Channel mode and 5 Channel mode. The DMX address is set elec­tronically using the controls on the rear of the unit. Your unit and your DMX controller require a stan­dard 3-pin XLR connector for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember
that DMX cable must be daisy chained and cannot be split.
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con­nect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
Figure 2
XLR Male Socket
1 Ground
2 Cold
3 Hot
Figure 3
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic
Figure 1
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
American DJ® - www.americandj.com - VioSCAN LED Instruction Manual Page 6American DJ® - www.americandj.com - VioSCAN LED Instruction Manual Page 5
XLR Female Socket
2 Cold
XLR Pin Conguration
1 Ground
3 Hot
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
When longer runs of cable are
Figure 4
Loading...
+ 7 hidden pages