ADJ UV Flood 36 Users Manual

Page 1
UV FLOOD 36
©2015 ADJ Products, LLC all rights reserved. Information,
specications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby dis­claim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indi­rect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation of this product.
Rev. 11/15
User Instructions
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC) Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Page 2
UV Flood 36 Introduction
UV Flood 36 General Instructions
Unpacking: Thank you for purchasing the UV Flood 36 by ADJ Prod-
ucts, LLC. Every UV Flood 36 has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the ship­ping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are miss­ing, please contact our toll free customer support number for further instructions. Do not return this unit to your dealer without rst contact­ing customer support.
Introduction: The UV Flood 36 is part of ADJ’s continuing pursuit for
creating high quality affordable intelligent fixtures. The UV Flood 36 is a DMX intelligent LED color wash. This wash can be used in a stand alone mode or connected in a Master/Slave conguration. This unit has three operating modes: sound active mode, dimmer mode, and DMX
controlled.
Customer Support: ADJ Products, LLC provides a toll free cus-
tomer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacic Standard Time. Voice: (800) 322-6337 Fax: (323) 582-2941 E-mail: support@americandj.com To purchase parts online visit http://parts.americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
UV Flood 36 Features
• 3 Operating Modes: Sound Active Mode, Dimmer Mode, and DMX Controlled
• Electronic Dimming 0-100%
• Built in Microphone
• DMX-512 protocol
• 3 DMX Channel Modes: 1 Channel Mode, 2 Channel Mode, & 3 Channel Mode
UV Flood 36 Warranty Registration
The UV Flood 36 carries a 2 year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase and war-
ranty. You may also register your product online at www. americandj. com. All returned service items whether under warranty or not, must
be freight pre-paid and accompany a return authorization (R.A.) num­ber. If the unit is under warranty you must provide a copy of your proof of purchase invoice. Please contact ADJ customer support for a R.A. number.
UV Flood 36 Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter­nal optical lenses must be carried out periodically to optimize light output.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war­ranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 2
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
3. Always be sure to dry all parts completely before plugging the unit back in. Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue, dust, dew).
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 3
Page 3
UV Flood 36 Safety Precautions
UV Flood 36 Set Up
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required volt­ age for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out` doors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by t he manufacturer. See page 3 for cleaning details.
• Heat -The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (inclu­ d ing amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. The power-supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the appliance. C. The appliance has been exposed to rain or water. D. The appliance does not appear to operate normally or exhibits a marked change in performance.
Power Supply: The ADJ UV Flood 36 contains a automatic voltage
switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the cor­rect power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that trav­els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter­minals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compli­ant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The UV Flood 36 can be controlled via DMX-512 protocol. The UV Flood 36 has 3 DMX channel modes; 1 channel mode, 2 channel mode, & 3 channel mode. The DMX address is set on the rear panel of the UV Flood 36. Your unit and your DMX controller require a approved DMX­512 110 Ohm Data cable for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all professional sound and lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Figure 1
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 4
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 5
Page 4
UV Flood 36 Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
UV Flood 36 Operating Instructions
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con­nect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
When longer runs of cable are
Figure 4
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
XLR Male Socket
1 Ground
DMX512 OT
3-PIN XLR
2 Cold
3 Hot
1
3
2
DMX +
DMX -
XLR Female Socket
2 Cold
1 Ground
3 Hot
Figure 3
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
5-Pin XLR DMX Connectors.
connectors for DATA transmission in place of 3-pin. 5-pin XLR xtures may be implemented in a 3-pin XLR DMX line. When inserting stan­dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 6
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
Some manufactures use 5-pin XLR
3-Pin XLR to 5-Pin XLR Conversion
Pin 1
Pin 2
Pin 3
The display will lock and blackout after 30 seconds, press the MODE button for 3 seconds to unlock.
DMX Mode:
Operating through a DMX controller give the user the freedom to cre­ate their own programs tailored to their own individual needs. The UV Flood 36 has 3 DMX modes: 1 Channel Mode, 2 Channel Mode, and 3 Channel Mode.
1. This function will allow you to control each individual fixture’s traits with a standard DMX-512 controller. See pages 10-11 for detailed description of the DMX values, and traits.
2. To control your fixture in DMX mode, follow the set-up procedures on pages 5-6 as well as the set-up specifications that are includ­ ed with your DMX controller.
3. Press the MODE button until “AXXX” is displayed. “XXX” is the represents the current DMX address. Use the UP and DOWN but­ tons to set your desired DMX address.
4. After you have set your desired DMX address, press the ENTER button to select your desired DMX channel mode. “CHXX” will be displayed. “XX” represent the current DMX channel mode. Use the UP and DOWN buttons to find your desired DMX channel
mode.
5. Once you have set your DMX address and DMX channel mode, use your DMX controller’s faders to control the various DMX fix­ ture traits.
6. For longer cable runs (more than a 100 feet) use a terminator on the last fixture.
Static Mode:
In this mode the UV light will remain static. You can adjust the inten­sity in this mode as well.
1. Plug the fixture in and press the MODE button until “LXXX” is dis-
played.
2. Press the UP or DOWN buttons to adjust the intensity of the light.
3. Press the ENTER button and “S-XX” will be displayed. This is the strobe mode. Use the UP or DOWN buttons to adjust the strobe
speed.
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 7
Page 5
UV Flood 36 Operating Instructions
UV Flood 36 Operating Instructions
Sound Active Mode:
In this mode the UV Flood 36 will react to sound.
1. Plug the fixture in and press the MODE button until “SoXX” is displayed. “XX” represents the sound sensitivity level. Use the UP and DOWN buttons to adjust the sensitivity. “00” is the lowest sensitivity, “30” is the highest.
Dimming Curve:
This is used to set the dimming curve used with DMX mode. See page 11 for the dimming curves diagram.
1. Plug the fixture in and press the MODE button until the DMX
address is displayed.
2. Press the ENTER button until “dCXX” is displayed. This is the dimmer setting. “XX” represents the current dimming mode.
3. Use the UP and DOWN buttons to find your desired dimmer curve. Press SET UP when you are finished.
• dC00 - Standard
• dC01 - Stage
• dC02 - TV
• dC03 - Architectural
• dC04 - Theater
DMX State:
This mode is used as a precaution mode, that in case the DMX signal is lost, the operating mode chosen in this setup is the running mode the xture will go into when the DMX signal is lost. You can also set this as the operating mode you would like the unit to return to when power
is applied.
1. Press the MODE button until the DMX address is displayed. Press the ENTER button until either “Soun”, “HOLd”, or “blC” is dis-
played.
2. Use the UP or DOWN buttons to nd the mode you want incase of power loss or DMX loss.
• “blC” (Blackout) - If the DMX signal is lost or interrupted, the unit will automatically go into stand by mode.
• “HOLd” (Last State) - If the DMX signal is lost or interrupted, the x-
ture will stay in the last DMX set up. If power is applied and this mode is set, the unit will automatically go into the last DMX set up.
• “Soun” (Sound Active) - If the DMX signal is lost or interrupted, the unit will automatically go into sound active mode.
3. Find your desired setting and press ENTER. Your setting will be saved automatically.
Activate RF Control:
This function is used to activate and deactivate the RF Remote Control. When this function is activated you can control the fixture using the Dotz Par RF remote. Please see the next page for remote controls and functions.
1. Plug the fixture in and press the MODE button until “rFXX” is dis- played. “XX” represents either “on” or “oFF”.
2. Press the UP or DOWN buttons to either activate the remote func­ tion (On) or deactivate it (Off).
UV Flood 36 Master-Slave Configuration
Master-Slave Configuration:
This function will allows you to link units together to run in a Master­Slave mode. In Master-Slave configuration one unit will act as the
controlling unit and the others will react to the controlling units built-in programs. Any unit can act as a Master or as a Slave however, only
one unit can be programmed to act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit. Use standard XLR microphone cables to link your units to- gether. Remember that the Male XLR connector is the input and the Female XLR connector is the output. The first unit in the chain (master) will use the female XLR connector only. The last unit in the chain will use the male XLR connector only.
2. Using the Master unit, choose your desired operating mode and connect the “Slave” unit or units.
3. On the “Slave” unit(s) press the MODE button until a “SLAV” is displayed. They will now follow the “Master” unit.
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 8
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 9
Page 6
UV Flood 36 Dotz RF Remote Operation
The Dotz Par RF remote (sold separately) has many different func­tions and allows you to control your UV Flood 36 from long distance. The remote can control your system up to 25 meters. To use the remote you must first activate the fixtures receiver, to activate the re­ceiver please see the instructions on page 9.
BLACKOUT - Pressing this button will blackout the fixture.
COLOR - This button will activate the UV output. Use the “+” and “-”
buttons to adjust the output intensity.
SOUND ACTIVE - This button activates sound active mode.
UV Flood 36 1 Channel Mode
Channel Value Function
1 DIMMER
0 - 255 0% - 100%
UV Flood 36 2 Channel Mode
Channel Value Function
1 DIMMER
0 - 255 0% - 100%
2 STROBING 0 - 31 LED ON 32 - 95 STROBING SLOW - FAST 96 - 127 LED ON 128 - 159 PULSE STROBE SLOW - FAST 160 - 191 LED ON 192 - 223 RANDOM STROBE SLOW - FAST 224 - 255 SOUND ACTIVE STROBING
UV Flood 36 3 Channel Mode
Channel Value Function
1 DIMMER
0 - 255 0% - 100%
2 STROBING 0 - 31 LED ON 32 - 95 STROBING SLOW - FAST 96 - 127 LED ON 128 - 159 PULSE STROBE SLOW - FAST 160 - 191 LED ON 192 - 223 RANDOM STROBE SLOW - FAST 224 - 255 SOUND ACTIVE STROBING 3 DIMMER CURVES 0 - 20 STANDARD 21 - 40 STAGE 41 - 60 TV 61 - 80 ARCHTECTURAL 81 - 100 THEATRE 101 - 255 DEFAULT TO UNIT CURRENT SETTING
UV Flood 36 Dimmer Curve Chart
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 10
Ramp Effect
Standard
Stage
TV
Architectural
Theatre
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 11
(Fade Time) (Fade Time)
Page 7
UV Flood 36 Photometric Chart
UV Flood 36 Power Cord Daisy Chain
Beam angle 57° Field angle 93°
Intensity(LUX)
3
2
1
0
1
Beam opening(m)
2
3
0 1 2 3 4 5
Diameter
(m)
Diameter
(m)
201 45 18 9 4UV LEDs
1.09
2.11
2.17
4.22
With this feature you can connect the xtures to one another
using the I.E.C. input and output sockets. The quantity that can
be connected is 26 xtures maximum for 120V and 57 xtures maximum for 230V. After the maximum xtures has been reached
you will need to use a new power outlet. They must be the same
xtures. DO NOT mix xtures.
UV Flood 36 Fuse Replacement
First unplug the power. Locate and remove the unit’s power cord. Once the cord has been removed located the fuse holder located inside the power socket. Insert a flat-head screw driver into the power socket and gently pry out the fuse holder. Remove the bad fuse and replace with a new one. The fuse holder has a built-in socket for a
57
93
spare fuse be sure not to confuse the spare fuse with active fuse.
UV Flood 36 Trouble Shooting
Listed below are a few common problems the user may encounter, with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are
3.26 4.34 5.4357°
6.32 8.43 10.5393°
wired correctly (pin 3 is “hot”; on some other DMX devices pin 2 may be ‘hot’). Also, check that all cables are connected to the right connectors; it does matter which way the inputs and outputs are connected.
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 12
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 13
Page 8
UV Flood 36 Warranty
MANUFACTURER’S LIMITED WARRANTY
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service you must obtain a Return Authorization number (RA#)
before sending back the product–please contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All
shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in it’s original package. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintnance, cleaning or periodic check up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear indentifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product.
This warranty is the only written warranty applicable to ADJ Products, LLC Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
MANUFACTURER’S LIMITED WARRANTY PERIODS:
•LightingProducts=1-year(365days)LimitedWarranty(Such as: Special Effect Lighting, Intelligent
Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
•LaserProducts=1Year(365Days)LimitedWarranty(excluding laser diodes which have a 6 month
limited warranty)
•L.E.D.Products=2-year(730days)LimitedWarranty(excluding motors, PCB boards, and power supplies, which have a 1-year (365 day Limited Warranty) batteries which have a 180 day limited war-
ranty). Only the L.E.D.s carry a 2-year warranty (excluding StarTec Series which a carries a 90 Day
Limited Warranty)
•ADJDMXControllers=2Year(730Days)LimitedWarranty(excluding faders and tact switches)
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 14
UV Flood 36 Specifications
Model:
UV Flood 36
Working Position: Any safe working position Voltage: 100V ~ 240V, 50/60Hz LEDs: 12 x 3W UV LEDs Wavelength: 395-400nm Power Draw: 35W Power Cord Daisy Chain: 26 Fixtures Max. (120V) 57 Fixtures Max. (230V) Beam Angle: 57 Degrees Fuse: 1Amp Weight: 5lbs./ 2.2Kgs. Dimensions: 11.75” (L) x 9.25” (W) x 4.5” (H) 300 x 235 x 115mm Colors: UV DMX Channels: 3 DMX Channel Modes: 1 Channel Mode, 2 Channel Mode, & 3 Channel Mode Warranty: 2 Year (730 days)
Auto Sensing Voltage: This xture contains a electronic volt-
age switch, which will auto sense the voltage when it is plugged into the power source.
Please Note: Specications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
ADJ Products, LLC
6122 S. Eastern Ave. Los Angeles, CA 90040 USA
Tel: 323-582-2650 / Fax: 323-725-6100
Web: www.adj.com / E-mail: info@americandj.com
A.D.J. Supply Europe B.V.
Junostraat 2
6468 EW Kerkrade
The Netherlands
service@adjgroup.eu / www.adj.com
Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99
Loading...