©2022 ADJ Products, LLC all rights reserved. Information, specications, diagrams, images, and
instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying prod­uct names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or regis­tered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their respective compa­nies.
ADJ Products, LLC and all afliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufcient and negligent assembly, installation, rigging, and opera­tion of this product.
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document may be available online. Please check www.adj.com for the latest revision/update of this manual before beginning installation and/or programming.
Date
06/30/2022 1.0 1.01 17 / 20 / 22 ch. Initial Release
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC) Saving electric energy is a key to help protecting the enviroment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Document
Version
Software
Version
DMX Channels Notes
2
TABLE OF CONTENTS
Introduction 4 Limited Warranty (USA Only) 5 Warranty Registration | Features 6 Safety Precautions 7 Overview 9 Installation 10 Remote Device Management (RDM) 13 Color Wheels 14 Gobos 15 Control Panel 18 System Menu 19 DMX Set Up 22 DMX Traits 24 Dim Speeds 31 Dim Modes 32 Primary-Secondary Set Up | Multi Unit Power Linking 33 Maintenance Guidelines 34 Torque Settings for Screws 35 Error Codes 37 Dimensional Drawings 38 Specifications 39
3
INTRODUCTION
Unpacking: Thank you for purchasing the Hydro Spot 1 by ADJ Products, LLC. Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to have been dam-
aged, carefully inspect your xture for any damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event that damage has been found or parts are missing, please con­tact our toll free customer support number for further instructions. Do not return this unit to your dealer
without rst contacting customer support.
Introduction: The ADJ Hydro Spot 1 is a feature-packed, LED-powered moving head spot luminaire housed within a robust IP65-rated housing. This product is intended to be used by professionally
trained personnel only and is not suitable for private use.
Customer Support: Contact ADJ Service for any product related service and support needs. Also visit
forums.adj.com with questions, comments or suggestions.
Parts: To purchase parts online visit:
http://parts.adj.com (US) http://www.adjparts.eu (EU)
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST Voice: 800-322-6337 | Fax: 323-582-2941 | support@adj.com
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | support@americandj.eu
ADJ PRODUCTS LLC USA
6122 S. Eastern Ave. Los Angeles, CA. 90040
323-582-2650 | Fax 323-532-2941 | www.adj.com | info@adj.com
ADJ SUPPLY Europe B.V
Junostraat 2 6468 EW Kerkrade, The Netherlands
+31 (0)45 546 85 00 | Fax +31 45 546 85 99
www.americandj.eu | info@americandj.eu
ADJ PRODUCTS GROUP Mexico
AV Santa Ana 30 Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
CAUTION! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself,
as doing so will void your manufacturer’s warranty. In the unlikely event your unit may require service,
please contact ADJ Products, LLC.
Do not discard the shipping cartoon in the trash. Please recycle when ever possible.
4
LIMITED WARRANTY (USA ONLY)
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of
manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see
specic warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish
the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, you must obtain a Return Authorization number (RA#) before sending the product
back—please contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be prepaid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return ship­ping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall incur no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is
modied in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the
product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is dam­aged because it was not properly maintained as set forth in the product instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include maintenance, cleaning, or periodic check-
up. During the period specied above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by reason of
defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear identifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products
without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with
products described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or tness, are limited in duration to the warranty period set forth above. And all warranties, whether expressed or implied, including warranties of merchantability or tness, are limited in duration to the warranty period set forth above. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly
provided above; and under no circumstances shall ADJ Product, LLC be liable for any loss and/or damage, direct and/or consequential arising out of the use of, and/or inability to use this product.
G. This warranty is the only written warranty applicable to ADJ Products, LLC products, and supersedes all
prior warranties and written descriptions of warranty terms and conditions heretofore published.
MANUFACTURER’S LIMITED WARRANTY PERIODS:
Non-LED Lighting Products = 1-Year (365 Days) (Including Special Effect Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands,
Power/Data Distribution, etc. excluding LED and lamps)
Laser Products = 1-Year (365 Days) (excluding laser diodes which have a 6-Month Limited Warranty)
LED Products = 2-Year (730 Days) (excluding batteries which have a 180 Day Limited Warranty)
NOTE: 2-Year (730 Days) Limited Warranty ONLY applies to product purchased within the United States.
StarTec Series = 1-Year (365 Days) (excluding batteries which have a 180 Day Limited Warranty)
ADJ DMX Controllers = 2 Year (730 Days)
American Audio Products = 1 Year (365 Days)
5
WARRANTY REGISTRATION
Please fill out the enclosed warranty card to validate your purchase. All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain an R.A. number by contacting our customer support team. All pack­ages returned to the service department not displaying an R.A. number on the outside of the package will be returned to the shipper.
FEATURES
Motorized Focus
Motorized Zoom: 12° ~ 23°
2 Frost Filters (Heavy and Medium)
2 Prism FX: Rotating 5-facet Linear & rotating 6-facet Circular
0-100% smooth dimming
Various strobe speeds
2 cooling fans
INCLUDED ITEMS
Omega Bracket (x1)
Locking Power Cable (x1)
IP RATING
An IP rated lighting fixture is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The Ingress Protection (IP) rating system is commonly expressed as “IP” followed by two num-
bers (i.e. IP65), where the numbers define the degree of protection. The first digit (Foreign Bodies
Protection) indicates the extent of protection against particles entering the fixture and the second digit (Water Protection) indicates the extent of protection against water entering the fixture. An IP65 rated
lighting fixture, such as this one, has been designed and tested to protect against the ingress of dust (6) and low-pressure water jets from any direction (5).
6
SAFETY PRECAUTIONS
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED.
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT
ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S
WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS
MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO
ANY WARRANTY CLAIMS AND/OR REPAIRS.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
Maximum ambient operating temperature is 113° F (45° C)!
DO NOT TOUCH the fixture housing during operation. Disconnect the power and allow approxi­mately 15 minutes for the fixture to cool down before servicing.
DO NOT shake the fixture, and avoid brute force when installing and/or operating the fixture.
DO NOT operate the fixture if the power cord has become frayed, crimped and/or damaged. If the power cord is damaged, replace immediately with a new one of the same power rating.
DO NOT attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
DO NOT attempt to operate this unit if it has been damaged in any way.
DO NOT spill water or other liquids into or on to your unit.
Disconnect from main power before making any type of connection.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and never blocked.
Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
Always be sure to mount this unit in an area that will allow proper ventilation.
DO NOT remove the cover under for any reason.
When installing fixture in a suspended enviroment, always use mounting hardware that is no less
than M10 x 25mm, and always install fixture with an appropriately rated safety cable.
Never plug this unit in to a dimmer pack.
During long periods of non-use, disconnect the unit’s main power.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to be walked on or pinched by
items placed upon or against them, paying particular attention to the point where they exit from the
unit.
Cleaning - The fixture should be cleaned only as recommended by the manufacturer.
Heat - The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when: A. The power-supply cord or the plug have been damaged. B. Objects have fallen onto, or liquid has been spilled into, the fixture. C. The fixture does not appear to operate normally or exhibits a marked change in performance. D. The fixture has fallen and/or has been subjected to extreme handling.
7
SAFETY PRECAUTIONS
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION!
FIXTURE EMITS HIGH INTENSITY ULTRAVIOLET (UV) LIGHT FROM THE UV LED.
WEAR PROPER EYE AND SKIN PROTECTION.
AVOID PROLONGED PERIODS OF EXPOSURE TO THE UV LED.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN.
AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m).
DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER.
DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW (UV) LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT.
INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DIS­ORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION MAY EXPERIENCE DIS­COMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE.
8
OVERVIEW
Mode
Button
Display Screen
Left
Button
Down
Button
Enter
Button
Right
Button
Up
Button
Carry
Handle
Power
In
Safety
Cable
Loop
Power
Out
Fuse
Omega Bracket Mounts
DMX
Out
DMX
In
Carry
Handle
9
INSTALLATION
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and construc­tion codes and regulations.
When installing the unit, the trussing or area of installation must be able to support at least 10 times the weight of the unit and any attached accessories without any deformation. The unit must be secured with a secondary safety attachment, e.g. an appropriately-rated safety cable.
Before rigging/mounting a fixture to any metal truss/structure or placing the fixture(s) on any surface, a
professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accesso­ries.
Maximum ambient operating temperature is 113°F (45°C).
Fixture(s) should be installed away from walking paths, seating areas, or areas where unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing, or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable that can hold at least 10 times the weight of the fixture.
Overhead mounting requires extensive experience, including calculating working load limits, knowl-
edge of installation material being used, and perodic safety inspection of all installation material as well as the unit itself. If you lack these qualifications, do not attempt the installation yourself.
The installaiton should be checked by a skilled person once a year.
10
INSTALLATION
CLAMP MOUNTING
This fixture features mounting points on the underside for the attachment of two Omega brackets.
Additionally, the unit also features a safety cable loop on the underside, near one of the carry handles
(see the illustration below). When mounting the fixture to a truss or any other suspended or overhead
installation, be sure to secure appropriately rated mounting clamps (not included) to each Omega bracket. Please note that two Omega brackets and two mounting clamps are needed to safely support the fixture in a suspended installation. Attach a separate SAFETY CABLE of the appro- priate weight rating to the provided safety cable loop. NEVER use carry handles as an attachment points for the safety cable.
MOUNTING
CLAMPS
OMEGA
CLAMP
MOUNTING
POINTS
(2 per clamp)
OMEGA
CLAMPS
SAFETY
CABLE
LOOP
SAFETY CABLE:
ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIX-
TURE IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE FIXTURE
WILL NOT FALL IF THE CLAMP FAILS.
11
INSTALLATION
POTENTIAL INTERNAL FIXTURE DAMAGE FROM EXTERNAL SOURCES OF LIGHT BEAMS
External sources of light beams from direct sunlight, lighting and moving head fixtures, and lasers, which are focused directly towards the exterior housing and/or penetrate the front lens opening of ADJ lighting fixtures, can cause severe internal damage including burning of optics, dichroic color filters,
glass and metal gobos, prisms, animation wheels, frost filters, iris, shutters, motors, belts, wiring, dis­charge lamps, and LEDs.
This issue is not specific only to ADJ lighting fixtures, but rather it is a common issue with lighting fix­tures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can reduce the risk of potential damage. Contact ADJ Service for more details.
DO NOT EXPOSE THE FIXTURE AND/OR FRONT LENS OPENING TO LIGHT BEAMS FROM DIRECT SUNLIGHT, OTHER LIGHTING OR MOVING HEAD FIXTURES, AND LASERS DURING UNPACKING, INSTALLATION, USE, AND EXTENDED IDLE TIMES OUTDOORS. DO NOT FOCUS A LIGHT BEAM FROM ONE LIGHTING FIXTURE DIRECTLY TOWARDS ANOTHER.
SUN PROTECTION MODE/ HIBERNATION MODE:
This state can be set via DMX, or the device will go into this state after 3 minutes without a DMX sig­nal. This function can be switched on or off in the DMX traits (see the DMX Traits section for details). When the sun protection is activated, the pan-and-tilt function of the moving-head will position the lens away from direct sunlight, or other high intensity light source, to protect the internal belts, electronics etc. from burn damage.
When the unit is in the ‘sun protection state’, it uses its accelerometer sensors (X-Y-Z) (only present on
discharge units and IP units) to position the front lens downwards, even when the unit(s) will be moved from its position. This will keep on changing the position of the head.
Please note that ‘manual mode’ overrides the ‘sun-protection mode’. The hibernation function is
an existing feature that puts the unit into a ‘sleep state’ to save power (this is a state where only the
electronics remain on, and all other functions are turned off, functions such as motors lamps etc). This state is automatically activated when no DMX signal is present for the set time (1-99min or off).
12
REMOTE DEVICE MANAGEMENT (RDM)
NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data standard for
lighting, allowing the DMX systems of the xtures to be modied and monitored remotely. This proto-
col is ideal for instances in which a unit is installed in a location that is not easily accessible.
With RDM, the DMX512 system becomes bi-directional, allowing a compatible RDM enabled con-
troller to send out a signal to devices on the wire, as well as allowing the xture to respond (known as
a GET command). The controller can then use its SET command to modify settings that would typi-
cally have to be changed or viewed directly via the unit’s display screen, including the DMX Address,
DMX Channel Mode, and Temperature Sensors.
FIXTURE RDM INFORMATION:
RDM Code Device ID Device Model ID Personality ID
Basic 17 (1)
0x1900 26 0000-FFFF 26
Standard 20 (2)
Extend 22 (3)
Please be aware that not all RDM devices support all RDM features, and therefore it is important to check beforehand to ensure that the equipment that you are considering includes all of the fea­tures that you require.
The following parameters are accessible in RDM on this device:
[0x0015] Comms Status [0x00E1] DMX Personality Description [0x0020] Queued Messages [0x0200] Sensor Denition [0x0030] Status Message [0x0201] Sensor Value [0x0031] Status ID Description [0x0400] Device Hours [0x0032] Clear Status ID [0x0405] Device Power Cycles [0x0080] Device Model Description [0x0500] Display Invert [0x0081] Manufacturer Label [0x0501] Display Level [0x0082] Device Label [0x0600] Pan Invert [0x0090] Factory Defaults [0x0601] Tilt Invert [0x00C1] Boot Software Version ID [0x1001] Reset Device [0x00E0] DMX Personality
13
COLOR WHEELS
COLOR WHEEL 1
CTB
(5600K)
High CRI
UV
Orange
Red
Medium
Blue
Green
Amber
Magenta
Blue
Green
COLOR WHEEL 2
Yellow
Light
Purple
CTO
(3200K)
UV
Pink
14
GOBOS
DESIGNS
3
4
2
5
1
6
GOBO DIMENSIONS
Thickness Inner (Viewable) Diameter Outer Diameter
0 in
0.002in
(0.5mm)
0.75in
(19.0mm)
0.906in
(23.0mm
-0.008in
0mm
-0.2mm
)
15
GOBOS
ROTATING GOBO HOLDER DIMENSIONS
ø 0.94in (24.0mm)
ø 0.906in (23.0mm
+0.004 in
-0.0 in
+0.1 mm
-0.0 mm
)
ø 0.83in (21.0mm)
ø 0.906in (23.0mm
+0.008 in
-0.004 in
+0.2 mm
-0.1 mm
)
(3.0mm)
0.12in
Orientation
Point
(6.2mm)
0.24in
16
ø 0.83in
(21.0mm)
GOBOS
REPLACEMENT PROCEDURE
1. Place the device on a at, stable surface, and allow the device to cool down for at least 1 hour before beginning this procedure.
2. Engage both the pan and tilt locks, and remove the head covers.
3. Locate the gobo module, which can be identied by nding the cooling fan located near the middle of the module, as shown in the illustration below. Disconnect any electrical connectors linking the
module to the xture head, and remove the screws holding the module in place. Slide the module
out of the head.
4. Pull the gobo holder away from the gobo wheel, then gently slide it outwards. Use a pair of needle nose pliers to carefully remove the retainer spring from the gobo holder. The gobo can now be removed from the gobo holder, and replaced with a new gobo. Reassemble by reversing these steps.
17
CONTROL PANEL
The Hydro Spot 1 features a display screen with a 6-button control pad, which can be used to easily adjust any device settings.
• The MODE button cycles through main menu options, or returns to the previous menu without mak-
ing changes.
The ENTER button is used to select the highlighted option, or to conrm a selection.
• The UP, DOWN, LEFT, and RIGHT buttons are used to navigate and adjust menu options and set-
tings displayed on the screen.
KEY LOCK
This function allows the user to configure whether or not the display screen and control panel keys will lock after a certain period of inactivity. It can be accessed by navigating to Personality > Display > Key Lock in the system menu. The setting options are described below:
OFF: The display screen and control panel keys remain active at all times.
ON: The display screen and control panel keys automatically lock after a certain period of inactiv-
ity, which can be set under Personality > Display > Screen Saver Delay. To unlock, press and hold the MODE button for 10 seconds.
ON1: The display screen and control panel keys automatically lock after a certain period of inac­tivity, which can be set under Personality > Display > Screen Saver Delay. To unlock, press UP, DOWN, UP, DOWN, ENTER in that order.
18
SYSTEM MENU
DMX Address 001 - xxx
DMX Channel Mode
DMX SETTINGS
No DMX Status
Prim/Sec Mode Primary / Secondary
Select Signal
Wiy Settings
PERSONALITY
Status Settings
Fan Settings
Zoom Speed
Basic 17
Standard 20
Extended 22
Holds last settings
Hold Last
Blackout
Manual
Internal Programs
DMX or Wiy
Wiy and DMX Out
Wiy Enable On / Off
Set Wiy Channel 00 - 14
Pan Degree 540 / 630
Pan Invert On / Off
Tilt Invert On / Off
P/T Feedback On / Off Pan/Tilt Feedback
P/T Speed
Hibernation Off, 01min - 99 min Default = 15min
Head Fan
Base Fan
Standard
Fast
Speed 1
Speed 2
Auto
High
Low
Auto
High
Low
when DMX signal is lost
Takes all channels to 0 when DMX signal is lost
Reverts to manual mode when DMX signal is lost
Reverts to se­lected internal program when DMX signal is lost
DMX has prior­ity; green LED
indicates Wiy
connected, and red LED indicates Wiy not con­nected
DMX XLR output sends DMX signal out
Pan/Tilt Speed
CONTINUED ON NEXT PAGE
19
SYSTEM MENU
Dim Modes
LED Refresh Rate
Dim Curve
Reset Motors
PERSONALITY (continued)
Display
Service Passcode = 050
Pan 000 - 255
MANUAL CONTROL
Pan Fine 000 - 255
Tilt 000 - 255
Tilt Fine 000 - 255
... ...
Standard
Stage
TV
Architectural
Theatre
Stage 2
Dim Speed 0.1s - 10.0s
900 Hz-1500 Hz, 2500 Hz, 4000 Hz, 5000 Hz, 6000 Hz, 10 KHz, 15 KHz, 20 KHz, 25 KHz
Square
Linear
Inv Squa
S Curve
Reset All Motors Yes / No
Pan/Tilt Reset Yes / No
... ...
Effect Reset Yes / No
Intensity 1 - 10
Display Invert Yes / No
Screen Saver Delay
Key Lock
Off - 10 min Default = 05 min
Off Keys do not lock
On
On1
Pan 000 - 255
Tilt 000 - 255
Effect Adjust (Calibration)
Update Software Off / On
Factory Restore Passcode = 011
Color1 000 - 255
Color2 000 - 255
Gobo 000 - 255
Shutter 000 - 255
...
Off / On
Default = 1200 Hz
Press and hold MODE button for 10 sec to unlock keys
Press Up, Down, Up, Down, Enter to unlock keys
CONTINUED ON NEXT PAGE
20
SYSTEM MENU
INTERNAL PROGRAMS
INFORMATION
Program 1
Program 2
... ... ...
Program 7
Fixture Life Time
Total LED Time
Fixture Temps
Fixture Humidity
Fan Info (RPM)
DMX Values
Error Logs
Software Version U:xxx
Speed 000 - 255
Fade 000 - 255
Speed 000 - 255
Fade 000 - 255
Speed 000 - 255
Fade 000 - 255
Power On Time xxxxxx Hours
P-On Time-R xxxxxx Hours
P-On Time-Reset Passcode = 050
LED On Time xxxxxx Hours
LED On Time-R xxxxxx Hours
LED Hours Reset Passcode = 050
Current xxx F / xxx C
LEDs
Max Resettable xxx F / xxx C
Current xxx F / xxx C
Base Temp
Max Resettable xxx F / xxx C
Reset LED Temp Yes / No Passcode = 050
Reset Base Temp Yes / No Passcode = 050
Head xxx %
Base xxx %
LED Fan xxxx RPM LED
Base Fan xxxx RPM
Pan
Pan Fine
...
xxxxx
Reset Error Log Yes / No Passcode = 050
Total lifetime
hours that xture
has been pow­ered on, cannot be reset
Hours powered on since last reset
Reset hours pow­ered on
Total lifetime hours that LED has been run, cannot be reset
Hours LED has been run since last reset
Reset LED run hours
Displays current LED temp
Max recorded
LED temp since last reset
Displays current base temp
Max recorded
base temp since last reset
List errors one by one
21
DMX SET UP
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of commu-
nication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of different manufacturers to be
linked together and operate from a single controller, as long as all fixtures and the controller are
DMX compliant. To ensure proper DMX data transmission, try to use the shortest cable path possible
when linking several DMX fixtures. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example, a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line: at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): This unit can be controlled via DMX­512 protocol. The DMX address is set on the rear panel of the unit. Your unit and your DMX controller require a standard 5-pin XLR connector for data input and data output. We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male XLR connector at one end and a female XLR connector at the other. Also remember that DMX cable must be daisy chained and cannot be split.
Notice: Be sure to follow the diagram below when making your own cables. Do not use the ground
lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come into contact with the XLR’s outer casing. Grounding the shield could cause
a short circuit and erratic behavior.
Special Note: Line Termination. When longer runs of cable are used, you may need to use a termi­nator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will reduce the risk of erratic behavior.
22
DMX SET UP
DMX ADDRESSING.
All fixtures should be given a DMX starting address when using a DMX controller, so the correct fix­ture responds to the correct control signal. This digital starting address is the channel number from
which the fixture starts to “listen” to the digital control signal sent out from the DMX controller. The
assignment of this starting DMX address is achieved by setting the correct DMX address on the digi-
tal control display on the fixture.
You can set the same starting address for all fixtures or a group of fixtures, or set different addresses for each individual fixture. Setting all fixtures to the same DMX address will cause all fixtures to react in the same way. In other words, changing the settings of one channel will affect all the fixtures simul-
taneously.
If you set each fixture to a different DMX address, each unit will start to “listen” to the channel number you have set, based on the quantity of DMX channels of each fixture. That means changing the set­tings of one channel will only affect the selected fixture.
For example, when this unit is operating in 17 channel mode, you should set the starting DMX
address of the first unit to 1, the second unit to 18 (1 + 17), the third unit to 35 (1 + 17 + 17), and so on. See the chart below for more details.
CHANNEL MODE UNIT 1 ADDRESS UNIT 2 ADDRESS UNIT 3 ADDRESS UNIT 4 ADDRESS
17 Ch 1 18 35 52 20 Ch 1 21 41 61 22 Ch 1 23 45 67
23
DMX TRAITS
CHANNEL
17 CH 20 CH 22 CH
1 1 1 000 - 255 Pan Movement, 540/630
2 2 000 - 255 Pan Fine
2 3 3 000 - 255 Tilt Movement, 270
4 4 000 - 255 Tilt Fine
3 5 5
4 6 6
DMX
VALUES
000 - 009 Open
010 - 016 Open / Red
017 - 023 Red
024 - 030 Red / Medium Blue
031 - 037 Medium Blue
038 - 044 Medium Blue / Green
045 - 051 Green
052 - 058 Green / Amber
059 - 065 Amber
066 - 072 Amber / Orange
073 - 079 Orange
080 - 086 Orange / High CRI
087 - 093 High CRI
094 - 100 High CRI / CTB (5600K)
101 - 107 CTB (5600K)
108 - 114 CTB (5600K) / UV
115 - 121 UV
122 - 127 UV / Open
128 - 189 Clockwise Color Wheel Rotation, fast to slow
190 - 193 No Rotation
194 - 255 Counter-Clockwise Color Wheel Rotation, slow to fast
000 - 009 Open
010 - 016 Open / Magenta
017 - 023 Magenta
024 - 030 Magenta / Blue
031 - 037 Blue
038 - 044 Blue / Green
045 - 051 Green
052 - 058 Green / Yellow
059 - 065 Yellow
066 - 072 Yellow / Light Purple
073 - 079 Light Purple
080 - 086 Light Purple / Pink
FUNCTION
Color Wheel 1
Color Wheel 2
CONTINUED ON NEXT PAGE
24
DMX TRAITS
CHANNEL
17 CH 20 CH 22 CH
4 6 6
5 7 7
6 8 8
DMX
VALUES
087 - 093 Pink
094 - 100 Pink / UV
101 - 107 UV
108 - 114 UV / CTO (3200K)
115 - 121 CTO (3200K)
122 - 127 CTO (3200K) / Open
128 - 189 Clockwise Color Wheel Rotation, fast to slow
190 - 193 No Rotation
194 - 255 Counter-Clockwise Color Wheel Rotation, slow to fast
000 - 004 Open
005 - 019 Gobo 1 - Dotted Tunnel
020 - 034 Gobo 2 - Scattered Triangles
035 - 049 Gobo 3 - Swipe
050 - 064 Gobo 4 - Flower Petals
065 - 079 Gobo 5 - Starry Night
080 - 094 Gobo 6 - Swirl
095 - 109 Gobo 1 Shake, slow to fast
110 - 124 Gobo 2 Shake, slow to fast
125 - 139 Gobo 3 Shake, slow to fast
140 - 154 Gobo 4 Shake, slow to fast
155 - 169 Gobo 5 Shake, slow to fast
170 - 189 Gobo 6 Shake, slow to fast
190 - 221 Clockwise Gobo Wheel Rotation, fast to slow
222 - 223 No Rotation
224 - 255 Counter-Clockwise Gobo Wheel Rotation, slow to fast
000 - 127 Indexing
128 - 189 Clockwise Gobo Rotation, fast to slow
190 - 193 No Rotation
194 - 255 Counter-Clockwise Gobo Rotation, slow to fast
FUNCTION
Color Wheel 2 (continued)
Gobo Wheel
Gobo Rotation
CONTINUED ON NEXT PAGE
25
DMX TRAITS
CHANNEL
17 CH 20 CH 22 CH
7 9 9
8 10 10 000 - 255 Dimmer Intensity, 0% to 100%
11 000 - 255 Dimmer Intensity Fine
9 11 12
DMX
VALUES
000 - 031 Shutter Closed
032 - 063 Shutter Open
064 - 095 Strobe, slow to fast
096 - 127 Shutter Open
128 - 159 Pulse Effect, slow to fast
160 - 191 Shutter Open
192 - 223 Random Strobe, slow to fast
224 - 255 Shutter Open
000 - 005 No Prism - Open
006 - 066 Prism 1 (5 Facet Linear Prism)
067 - 127 Prism 2 (6 Facet Circular Prism)
129 - 135 Macro 1
136 - 143 Macro 2
144 - 151 Macro 3
152 - 159 Macro 4
160 - 167 Macro 5
168 - 175 Macro 6
176 - 183 Macro 7
184 - 191 Macro 8
192 - 199 Macro 9
200 - 207 Macro 10
208 - 215 Macro 11
216 - 223 Macro 12
224 - 231 Macro 13
232 - 239 Macro 14
240 - 247 Macro 15
248 - 255 Macro 16
000 - 005 Prism Rotation Off
FUNCTION
Shutter
Prisms and Prism/Gobo Macros
Prism Rotation
10 12 13
006 - 128
129 - 191 Clockwise Prism Rotation, fast to slow
192 No Rotation
193 - 255 Counter-Clockwise Prism Rotation, slow to fast
11 13 14 000 - 255 Focus, 0% to 100% 12 14 15 000 - 255 Zoom, narrow to wide
Prism Indexing, 0°...540°
CONTINUED ON NEXT PAGE
26
DMX TRAITS
CHANNEL
17 CH 20 CH 22 CH
16 000 - 255 Zoom Fine 13 15 17 000 - 255 Heavy Frost, 0% to 100% 14 16 18 000 - 255 Medium Frost, 0% to 100%
15 17 19
18 20
16 19 21
17 20 22
DMX
VALUES
000 - 020 Default to Unit Setting
021 - 040 Standard
041 - 060 Stage
061 - 080 TV
081 - 100 Architectural
101 - 120 Theater
121 - 140 Stage 2
141 - 160 Dim Speed, fast to slow (0.1s to 10.0s)
161 - 255 Default to Unit Setting
000 - 020 Square
021 - 040 Linear
041 - 060 Inv Squa
061 - 080 S Curve
081 - 255 No Function
000 - 225 Pan/Tilt, fast to slow
226 - 235 Blackout by Movement
236 - 245 Blackout by All Wheel Changing
246 - 255 No Function
000 - 039 No Function
040 - 049 Fan Control - Low (hold 3s)
050 - 059 Fan Control - High (hold 3s)
060 - 069 Fan Control - Auto (Default, hold 3s)
070 - 074 All motor reset (hold 3s)
075 - 079 Pan/tilt reset (hold 3s)
080 - 084 Color reset (hold 3s)
085 - 089 Gobo reset (hold 3s)
090 - 094 Focus and zoom reset (hold 3s)
095 - 099 Shutter reset (hold 3s)
100 - 104 No Function
105 - 109 Other motors reset (hold 3s)
110 - 148 No Function
FUNCTION
Dimmer Modes
Dim Curves
Pan/Tilt Speed
Special Functions
CONTINUED ON NEXT PAGE
27
DMX TRAITS
CHANNEL
17 CH 20 CH 22 CH
17 20 22
DMX
VALUES
149 - 150 Wiy On (Default, hold 3s)
151 - 152 Wiy Off (hold 5s) 153 - 154 Hibernation Enable (hold 3s) - see Installation section for details 155 - 156 Hibernation Off (hold 5s) - see Installation section for details
157 - 158 Display Backlight On (hold 3s)
159 - 160 Display Backlight Off (hold 5s)
161 - 162 Pan/Tilt Speed 1 (default, hold 5s)
163 - 164 Pan/Tilt Speed 2 (hold 5s)
165 - 166 Invert Pan On (hold 3s)
167 - 168 Invert Pan Off (hold 5s)
169 - 170 Invert Tilt On (hold 3s)
171 - 172 Invert Tilt Off (hold 5s)
173 900
174 910
175 920
176 930
177 940
178 950
179 960
180 970
181 980
182 990
183 1000
184 1010
185 1020
186 1030
187 1040
188 1050
189 1060
190 1070
191 1080
192 1090
193 1100
194 111 0
195 1120
196 1130
197 1140
FUNCTION
Special Functions (continued)
Refresh Rate (Hz, Hold 1s)
CONTINUED ON NEXT PAGE
28
DMX TRAITS
CHANNEL
17 CH 20 CH 22 CH
17 20 22
DMX
VALUES
198 1150
199 1160
200 1170
201 1180
202 1190
203 1210
204 1220
205 1230
206 1240
207 1250
208 1260
209 1270
210 1280
211 1290
212 1300
213 1310
214 1320
215 1330
216 1340
217 1350
218 1360
219 1370
220 1380
221 1390
222 1400
223 1410
224 1420
225 1430
226 1440
227 1450
228 1460
229 1470
230 1480
231 1490
232 1500
233 2500
234 4000
235 5000
FUNCTION
Refresh Rates (Hz, hold 3s) (continued)
CONTINUED ON NEXT PAGE
29
DMX TRAITS
CHANNEL
17 CH 20 CH 22 CH
17 20 22
DMX
VALUES
236 6000
237 10,000
238 15,000
239 20,000
240 25,000
241 Internal Program 1 (scenes 1-8, hold 3s)
242 Internal Program 2 (scenes 9-16, hold 3s)
243 Internal Program 3 (scenes 17-24, hold 3s)
244 Internal Program 4 (scenes 25-32, hold 3s)
245 Internal Program 5 (scenes 33-40, hold 3s)
246 Internal Program 6 (scenes 41-48, hold 3s)
247 Internal Program 7 (scenes 49-56, hold 3s)
248 - 255 No Function
FUNCTION
Refresh Rates (Hz, hold 3s) (continued)
30
DIM SPEEDS
DMX VALUES DELAY TIME
121 0.1 sec 122 0.2 sec 123 0.3 sec 124 0.4 sec 125 0.5 sec 126 0.6 sec 127 0.7 sec 128 0.8 sec 129 0.9 sec 130 1.0 sec 131 1.5 sec 132 2.0 sec 133 3.0 sec 134 4.0 sec 135 5.0 sec 136 6.0 sec 137 7.0 sec 138 8.0 sec 139 9.0 sec 140 10.0 sec
31
DIM MODES
DIMMER
100%
50%
10%
0%
255 255
0 0
Stage 2 0 1100 0 1660
Rise Time
Down Time
0 sec Fade Time
1 sec Fade Time
Time (ms)
0 Sec
Dimming Curve
Ramp Effect
Rise Time (ms) Down Time (ms) Rise Time (ms) Down Time (ms)
Standard (default) 0 0 0 0
Stage 780 1100 1540 1660
TV 1180 1520 1860 1940
Architectural 1380 1730 2040 2120
Theatre 1580 1940 2230 2280
32
PRIMARY-SECONDARY SET UP
This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit
will act as the controlling unit and the others will react to the controlling unit’s built-in programs. Any
unit can be configured to act as a Primary or as a Secondary, but only one unit in a given system can be programmed to act as the Primary.
Primary-Secondary Connections and Settings:
1. Daisy chain your units via the XLR connectors on the rear panels of each unit. Use standard XLR data cables to link your units together. Remember that the male XLR connector is the input and the female XLR connector is the ouput. The first unit in the chain (primary) will use the female XLR connector only, wile the last unit in the chain will use the male XLR connector only.
2. Use the display screen and control panel to navigate to Personality > Prim/Sec Mode. Select
this sub-menu using the ENTER button, and use the arrows to toggle between “Primary” and “Secondary”. Press ENTER to confirm your selection.
3. Repeat Step 2 for each unit in the system. Make sure that only one unit is designated as the Primary, while all other units are designated as Secondaries.
4. The secondary units will now follow the behavior of the primary unit.
MULTI UNIT POWER LINKING
This features allows you to connect the fixtures to one another using the power cable input and output
sockets.
The maximum number of units that can be linked in this manner is as follows:
• 3 units when running on 110V power.
• 8 units when running on 240V power.
DO NOT EXCEED THIS MAXIMUM NUMBER WHEN POWER LINKING UNITS!
All linked units must be of the same make and model type. Do not mix and match units!
33
MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to ensure proper function, optimized light output, and an extend­ed life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky, or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. Clean the external lens surface regularly with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to ensure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all other service issues to an authorized ADJ
service technician. Should you need any spare parts, please order genuine parts from your local ADJ dealer.
Please refer to the following points during routine inspections: A. A detailed electrical check by an approved electrical engineer every three months, to make sure
the circuit contacts are in good condition and prevent overheating.
B. Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out
during normal operation, resulting in damage or injury as larger parts could fall.
C. Check for any deformations on the housing, color lenses, rigging hardware, and rigging points
(ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the
fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously
injure a person(s).
D. Electric power supply cables must not show any damage, material fatigue, or sediments.
NEVER remove the ground prong from the power cable.
SOFTWARE UPDATES
For software updates, please contact ADJ service to obtain a software uploader and detailed instruc­tions. Refer to the Introduction section of this manual for contact information.
FIXTURE DISASSEMBLY
The following points should be observed after performing any maintenance procedure that requires disassembly of the unit:
After the unit has been reassembled, open the valve, and allow the light to run for approximately 2
hours in order to dry out any moisture that has been trapped inside the fixture. The process should
continue until indicated humidity drops below 15% for the head and 30% for the base.
Once this has been achieved, the light can be switched off, but the unit should remain connected to power so that the cooling fan can cool down the unit. Please note that allowing cool down time should ALWAYS be done after lamp operation.
Some units may require partial disassembly in order to gain access to the valve. Please contact ADJ service for information regarding the location and access procedure for the valve on your specific unit model.
34
TORQUE SETTINGS FOR SCREWS
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are Allen head
screws. Please refer to the table and diagram below for screw locations, quantity, and torque settings.
1
2
3
5
Zone
No.
Description Quantity Torque Spec
1 Lens Frame 4
2 Main Head Cover 7 per side (14 total)
3 Arm Cover 6 per side (12 total)
4 Base Side Cover 8 per side (16 total)
5 Carry Handle 2 per handle (4 total)
35
4
4.3 + 0.6 in-lb (5.0 + 0.7 Kg-cm)
6.9 + 0.6 in-lb (8.0 + 0.7 Kg-cm)
4.3 + 0.4 in-lb (5.0 + 0.5 Kg-cm)
6.9 + 0.6 in-lb (8.0 + 0.7 Kg-cm)
6.9 + 0.6 in-lb (8.0 + 0.7 Kg-cm)
TORQUE SETTINGS FOR SCREWS
TORQUE DRIVERS (Recommended): UTICA TS-30 (Shown)
TORQUE DRIVER (Alternate):
• Proto J6107A
• Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTURE USING THE IP TESTER. CONTACT ADJ SERVICE FOR MORE DETAILS.
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO
THE FIXTURE’S LENS WHILE PERFORMING THE TEST!
IP PRESSURE TESTING PARAMETERS
Maximum Pressure Minimum Pressure Steady/Hold Time
3.3 psi (23 KPa) 2.9 psi (20 KPa) 15 sec
36
ERROR CODES
When power is applied, the unit will automatically enter a “Reset/Test” mode. This mode brings all the internal motors to a home position. If there is an internal problem with one or more of the motors,
an error code will ash in the display, as described in the chart below. For example, when the dis­play shows “Pan” it means there is some type of error with the Pan motor. If there are multiple errors during the start-up process, they will all ash in the display. For example: if the xtures have errors on Pan, Tilt, and Color Wheel 1 all at the same time, you will see the error message “Pan”, “Tilt”, and “Color Wheel 1” ash repeated 5 times.
If an error does occur during the initial start-up procedure, the xture will self-generate a second reset
signal and try to realign all the motors and correct the errors. If the error persists after a second at­tempt, a third attempt will be made. If after a third attempt all the errors have not been corrected, the
xture will make the following determinations:
• 3 or More Errors: The xture cannot function properly with three or more errors. Therefore the
xture will place itself in a stand-by mode until subsequent repairs can be made.
• Less Than 3 Errors: The xture has less than 3 errors. Therefore, most other functions will work
properly. The xture will attempt to operate normally until the errors can be correct by a technician. The errors in question will remain ashing in the display as a reminder of internal errors.
Error Code Description
Pan Pan Error Tilt Tilt Error Color Wheel 1 Color Wheel 1 Error Color Wheel 2 Color Wheel 2 Error Focus Focus Error Zoom Zoom Error Gobo Gobo Wheel Error Rot Gobo Gobo Rotation Error Prism 1 Prism 1 Error Prism 1 Rot Prism 1 Rotation Error Prism 2 Prism 2 Error Prism 2 Rot Prism 2 Rotation Error LED Fan LED Fan Error Base Fan Base Fan Error LED Temp LED Temperature Error Base Temp Base Temperature Error
37
DIMENSIONAL DRAWINGS
Ø 2.97in (75.53mm)
19.22in (488.15mm)
14.94in (379.60mm)
0.36in
4.31in (109.40mm)
(9.22mm)
12.41in (315.17mm)
8.82in
(224.00mm)
7.82in (198.57mm)
11.48in (291.55mm)
10.33in (262.30mm)
13.14in (333.80mm)
8.18in (209.79mm)
9.41in (239.00mm)
8.17in (207.45mm)
9.09in (231.00mm)
14.13in (359.00mm)
6.43in
5.47in (163.45mm)
(139.00mm)
Drawings are not to scale.
9.41in (239.00mm)
38
SPECIFICATIONS
Light Source:
• 200W Cool White LED Engine (50,000 hr.)
Features:
• Motorized Focus
• Motorized Zoom: 12° ~ 23°
• 2 Frost Filters (Heavy and Medium)
• 2 Prism FX: Rotating 5-facet Linear & rotating 6-facet Circular
• 0-100% smooth dimming
• Various strobe speeds
• 2 cooling fans
Color Wheels:
• (2) Color wheels
• 8 dichroic colors + white on each wheel (includes CTO, CTB and UV filters)
GOBO Wheels:
(1) Wheel with 6 Rotatable Gobo’s
All Gobo’s are replaceable
• Gobo Shake Effect
• Aluminum GOBO size: 23mm (outer); 19mm (viewable); 0.5mm (thickness)
• Glass gobo size: 23mm (outer); 19mm (view­able); 3.3mm (thickness)
Prism Wheel:
• Prism Wheel 1: Rotatable 6-facet Circular
• Prism Wheel 2: Rotatable 5-facet Linear
Both Prisms are indexable
Frost Filters:
• Frost 1: Heavy frost for wash effect
• Frost 2: Medium frost creates lightly blurred edges for Gobo and Prism FX
Control:
• 3 DMX Channel Modes: 17/20/22-ch
• Color LCD display with 6-button function menu
• Control Mode: DMX512 or internal programs
• 6 Dim Modes: Standard, Stage, TV, Architectural, Theatre, Stage2
• 4 Dim Curves: Square, Linear, Inv. Square and S. Curve
• Selectable LED Refresh Rates (900 Hz~25K Hz)
• 0-100% smooth dimming
• Various strobe speeds
• RDM (Remote Device Management)
• With Wired Digital Communication Network
Pan/Tilt:
• Pan: 630 degrees
• Tilt: 270 degrees
Connections:
• DMX Connections: 5-pin XLR In/Out
• Power Connections: IP65 PowerLock In/Out to daisy chain power
Electrical:
• Multi-voltage operation: 90-240V, 50/60Hz
Max power consumption: 280W
Dimensions & Weight:
Dimensions (LxWxH): 9.49” x 14.57” x
19.21” (241x370x488mm)
• Weight: 35.2lbs (16kg)
Approvals / Rating:
• ETL Approved / CE Certified
IP65 with Marine Coated Exterior and con­formal coated PCBs
4010765
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without