ADJ Hydro Beam X2 User guide

HYDRO BEAM X2
User Instructions
©2019 ADJ Products, LLC all rights reserved. Information, specications, diagrams, images, and
FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:
· Reorient or relocate the device.
· Increase the separation between the device and the receiver.
· Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of
their respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation of this product.
DOCUMENT VERSION
Date
10/30/19
12/17/19
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Document Version
1 1.5
1.2
Software Version >
1.7
DMX Channel Mode
15 / 17 Initial Version
N/C Updated Display Lock/Unlock Feature
Notes
Hydro Beam X2 Table of Contents
Introduction Features I Warranty Registration IP65 Notice Safety Guidelines Overview Discharge Lamp Warning Lamp Installation Gobo Specications I Gobos Gobo Installation Fixture Installation
Connections
3 4 5
6
10 11 13 17 18 22 25
DMX Set Up DMX Addressing DMX Channel Modes
System Menu
WiFly Control Error Codes Dimensional Drawings Power Linking I Cleaning Limited Warranty (USA Only) Technical Specications
26
27 28 31 38 40 42 43 44 45
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 2
Hydro Beam X2 Introduction
Unpacking: Thank you for purchasing the Hydro Beam X2 by ADJ Products, LLC. Every Hydro Beam X2 has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are missing, please contact our toll free customer support number for further instructions. Do not return this unit to your dealer without rst contacting customer support.
Introduction: The ADJ Hydro Beam X2 is a DMX intelligent, IP rated, high powered, moving head fixture. To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. This product is intended to be used by
professionally trained personnel only and is not suitable for private use.
These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
Customer Support: Contact ADJ Service for any product related service and support needs. Also visit
forums.adj.com with questions, comments or suggestions.
Parts: To purchase parts online visit:
http://parts.adj.com (US) http://www.adjparts.eu (EU)
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST Voice: 800-322-6337 | Fax: 323-582-2941 | support@adj.com
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | support@adj.eu
ADJ PRODUCTS LLC USA
6122 S. Eastern Ave. Los Angeles, CA. 90040 323-582-2650 | Fax 323-532-2941 | www.adj.com | info@adj.com
ADJ SUPPLY Europe B.V
Junostraat 2 6468 EW Kerkrade, The Netherlands +31 (0)45 546 85 00 | Fax +31 45 546 85 99
www.adj.eu | info@adj.eu
ADJ PRODUCTS GROUP Mexico
AV Santa Ana 30 Parque Industrial Lerma, Lerma, Mexico 52000 +52 (728) 282-7070
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 3
Hydro Beam X2 Features
• IP65 Outdoor Rated
• Electronic Dimming 0-100%
• DMX-512 protocol
• IP65 Locking 5-Pin XLR Connectors In & Out
• Multiple DMX Modes
• IP65 Locking Power Connectors In & Out
• Colors: 10 + Open (Including 3200K, 5600K, UV, and Quad Split Color)
• Gobos: 11 Rotating/Replaceable Gobos + Open
• Prism 1: Rotating 6-Facet Linear
• Prism 2: Rotating 8-Facet Circular
• Frost Effect
• Motorized Focus
• Multiple Unit Power Linking (See page 43)
Included: 1 x IP65 Locking Power Cable 2 x Omega Brackets
Hydro Beam X2 Warranty Registration
The Hydro Beam X2 carries a 2 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre­paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under war­ranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All packages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the
shipper.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 4
Hydro Beam X2 IP Notice
IP65 RATED
An IP rated lighting xture is one, which is commonly installed in outdoor environments and has been designed with an enclosure that eectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as "IP" (Ingress Protection) followed by two numbers (i.e. IP65) where the numbers dene the degree of protection. The rst digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the xture and the second digit (Water Protection) indicates the extent of protection against water entering the xture. An IP65 rated lighting xture is one, which has been designed and tested to protect against the ingress of dust (6) and low-pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS
NOT suitable for marine and/or coastal environment installations. Installing this xture in a marine and/or coastal environment may cause corrosion and/ or excessive wear to the interior and/or exterior components of the xture.
Damages and/or performance issues resulting from installation in a marine and/or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and/or repairs.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 5
Hydro Beam X2 Safety Guidelines
FOR YOUR OWN PERSONAL SAFETY, PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY
BEFORE YOU ATTEMPT TO INSTALL OR OPERATE THIS UNIT!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG THE FIXTURE INTO A DIMMER PACK! NEVER OPEN THIS FIXTURE WHILE IN USE! UNPLUG POWER BEFORE SERVICING FIXTURE! NEVER TOUCH THE FIXTURE DURING OPERATION AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH AS RELOCATION FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, DO NOT POWER THE FIXTURE ON IMMEDIATELY. INTERNAL CONDENSATION AS A RESULT OF ENVIROMENTAL TEMPERATURE CHANGE CAN CAUSE INTERNAL FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS REACHED ROOM TEMPERATURE BEFORE POWERING ON.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
• Be sure that the local power outlet is compatible with the required voltage for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 43 for cleaning details.
• Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when the appliance does not appear to operate normally or exhibits a marked change in performance.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 6
Hydro Beam X2 Safety Guidelines
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
SAFETY G U I DELI NES
To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. ADJ Products, LLC is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufactures warranty and increase the risk of damage and/or personal injury.
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG FIXTURE INTO A DIMMER PACK! NEVER OPEN THIS FIXTURE WHILE IN USE! UNPLUG POWER BEFORE SERVICING FIXTURE! NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH AS RELOCATION FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, DO NOT POWER THE FIXTURE ON IMMEDIATELY. INTERNAL CONDENSATION AS A RESULT OF ENVIRONMENTAL TEMPERATURE CHANGE CAN CAUSE INTERNAL FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS REACHED ROOM TEMPERATURE BEFORE POWERING ON.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS!
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 7
Hydro Beam X2 Safety Guidelines
S A FETY GUI D ELI N E S
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET UV
RADIATION! FIXTURE EMITS HIGH INTENSITY WAVELENGTH
OF ULTRAVIOLET UV LIGHT FROM THE UV COLOR FILTER.
WEAR PROPER EYE AND SKIN PROTECTION. AVOID
PROLONGED PERIODS OF EXPOSURE TO UV COLOR FILTER.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING
UV PAINTS ON SKIN. AVOID DIRECT EYE AND/OR SKIN
EXPOSURE AT DISTANCES LESS THAN 11 feet (3.3m). DO NOT OPERATE FIXTURE
WITH DAMAGED/MISSING EXTERNAL COVERS. DO NOT LOOK DIRECTLY INTO THE
UV LIGHT AND/OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT
MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT. INDIVIDUALS SUFFERING
FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DIS-ORDERS, OR
INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT
IF EXPOSED TO THE ULTRAVIOLET UV LIGHT EMITTED FROM THE UV LED.
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow
approximately 60 minutes for the fixture to cool down before servicing.
DO NOT shake fixture; avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped, damaged and/or if any
of the power cord connectors are damaged and do not insert into the fixture securely with
NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of similar power rating.
DO NOT block any air ventilation slots; these must remain clean and never blocked.
Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
When installing fixture in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, and always attach an appropriately rated safety cable.
ALWAYS disconnect fixture from main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end; never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
ease.
Consistent operational breaks will ensure fixture will function properly for many years.
ONLY use the original packaging and materials to transport the fixture in for service.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 8
Hydro Beam X2 Safety Guidelines
POTENTIAL INTERNAL FIXTURE DAMAGE FROM EXTERNAL SOURCES OF LIGHT BEAMS
External sources of light beams from direct sunlight, lighting moving head xtures, and lasers, which are focused directly towards the exterior housing and/or penetrate the front lens opening of ADJ lighting xtures, can cause severe internal damage including burning to optics, dichroic color lters, glass and metal gobos, prisms, animation wheels, frost lters, iris, shutters, motors, belts, wiring, discharge lamps, and LEDs.
This issue is not specic only to ADJ lighting xtures, it is a common issue with lighting xtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can prevent any potential damage from occurring if followed. Contact ADJ Service for more details.
DO NOT EXPOSE THE FIXTURE AND/OR FRONT LENS OPENING TO LIGHT BEAMS FROM DIRECT SUNLIGHT, OTHER LIGHTING MOVING HEAD FIXTURES, AND LASERS WHILE UNPACKING, INSTALLATION, USE, AND EXTENDED IDLE TIMES OUTDOORS. DO NOT FOCUS A LIGHT BEAM FROM ONE LIGHTING FIXTURE DIRECTLY TOWARDS ANOTHER.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 9
Hydro Beam X2 Overview
MENU
ENTER
3 4 5 96 87 10111
2
1. Lens
2. MENU Button
3. ENTER Button
4. LCD Menu Control Display
5. DOWN Button
6. UP Button
7. IP65 Locking 5-Pin XLR Connector OUT
8. IP65 Locking 5-Pin XLR Connector IN
9. Gore Valve
10. IP65 Locking Power Connector IN
11. IP65 Locking Power Connector OUT
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 10
Hydro Beam X2 Discharge Lamp Warning
D I SCHARGE L A M P W ARNI N G
This fixture is fitted with a DISCHARGE LAMP, which is highly susceptible to damage if improperly handled. NEVER touch the lamp with your bare hands as the oil from your hands will shorten the life of the lamp. Also, NEVER move the fixture until the lamp has had ample time to cool. Lamps are NOT covered under warranty conditions. Avoid switching the fixture ON and OFF repeatedly in short intervals as this will reduce lamp life and intensity. To achieve the intensity associated with discharge lamps, these lamps use gas sealed in a high-pressure environment to emit a brilliant output.
Due to the high pressure involved with the construction of the lamp, the lamp MAY
EXPLODE DURING PROLONGED EXTENSIVE USE. This risk is increased with age;
added care is encouraged when dealing with older lamps. Thus, the lamp must always
be replaced at the end of their recommended duty cycle. Extreme caution should be
used when operating this or any fixture fitted with a gas discharge lamp.
U V RADI ATI ON NOT I C E
This fixture emits intense UV radiation, which is harmful to the
eyes and skin.
severe damage to the retina. NEVER operate this fixture with
ANY of the protective covers removed. These covers have been
specially designed to shield against UV radiation.
The intense luminance of the lamp can cause
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 11
Hydro Beam X2 Discharge Lamp Warning
LAMP REPLACEMENT WARNING
NOTE: The lamp life is represented in “Percentages”.
When the unit reaches 15% of lamp life left, the display will ash the message “Replace The Lamp Soon”. This message will ash for up to 10 minutes. To conrm this warning and return to normal operation,
press the ENTER button.
When the unit reaches 10% of lamp life left, the display will again ash the message “Replace The Lamp Soon”. This message will ash for up to 10 minutes. To conrm this warning and return to normal
operation, press the ENTER button. NOTE: When the xture is powered OFF and then back ON again, the xture display will ash the following message: “Replace The Lamp Soon”.
When the unit reaches between 5%-0%% of lamp life left, the display will ash the message “Replace The Lamp Immediately”. The unit will now NO longer respond to DMX commands and
enter hibernation mode which will discontinue all xture functionality with the exception of a few menu commands.The xture will continue to enter into hibernation mode until the lamp is replaced and the lamp time (LAMP ON TIME-R) has been reset. See page 36 “LAMP ON TIME-R” under the
“TOTAL LAMP TIME” submenu.
NOTE: After replacing the lamp, the lamp time MUST be reset. The lamp time must be reset to gain access to the full system menu.
Lamp Life may vary depending on several factors including but not limited to:
Enviromental Conditions, Power/Voltage, Usage Patterns (On-O Cycling), Control,
and Dimming.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 12
Hydro Beam X2 Lamp Installation
LAMP INSTALLATION
WARNING! LAMP REPLACEMENT SHOULD ONLY BE DONE BY A TRAINED TECHNICIAN.
1. Turn OFF power and allow approximately 60 minutes for the xture to cool down.
2. Unscrew the (4x) allen head screws to remove the rear cover. When removing the rear cover, please be advised that the cover is connected to the unit via a safety cable and connected wire
cable.
3. Gently remove the (2x) spade terminals connected to the lamp.
4. Loosen the Phillips head screw to unlock the lamp holding slider.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 13
Hydro Beam X2 Lamp Installation
5. Carefully slide the lamp to the right and tighten the Phillips head screw. Carefully remove the lamp from its holder and replace with the same type lamp.
6. Once the new lamp has been inserted, loosen the Phillips head screw again to allow the lamp holding mechanism to slide back to its closed position. Tighten the Phillips head screw.
Reconnect the (2x) spade terminal and replace the cover and tighten the (4x) Allen screws.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 14
Hydro Beam X2 Torque Settings & IP Tester
TORQUE SETTINGS FOR SCREWS
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are Allen Head
screws. Please see below for screw locations, screw quantity and torque settings. The number listed in the “#” column corresponds to the location on the xture. See the xture diagram and number on the next page for SCREW LOCATION depictions.
SCREW LOCATIONS TORQUE SETTING & TOOL SIZE#
1 Lens Assembly to Head Casting (x14) 6.5-8.7 In-Lb / 3mm Hex
2 Lamp Cover to Head Casting (x4) 6.7-9.6 In-Lb / 4mm Hex
3 Plastic Head Cover to Head Casting (4 x Each Side = 8 Total) 6.5-8.7 In-Lb / 3mm Hex
4 Yoke Arm Cover to Yoke Frame (11 x Each Side = 22 Total) 6.5-8.7 In-Lb / 3mm Hex
5 Access Cover to Yoke Frame (x4) Manual Screwdriver / 3mm Hex
6 Bottom Cover to Base Casting (x16) 6.7-9.6 In-Lb / 3mm Hex
7 Power & Data Connector to Base Casting (x8) 6.5-8.7 In-Lb / Torx T8
8 1/4 Turn Adaptor Plate to Bottom Cover (x16) 6.5-8.7 In-Lb / 3mm Hex
TORQUE DRIVERS (Recommended): UTICA TS-30 (Shown)
ALTERNATIVE DRIVERS: Proto J6107A Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES! TO CONFIRM THE IP65 INTENGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTURE USING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE DETAILS.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 15
Hydro Beam X2 Screw Locations
2
1
7
5
3
3
4 4
5
6
8
6
6
8
6
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 16
Hydro Beam X2 Gobo Specifications
* * * IMPORTANT NOTICE REGARDING CUSTOM GOBOS * * *
Due to the extreme high temperature optical system, special BOROFLOAT glass material and design criteria are required.
Due to varying gobo manufacturing processes and tolerances, it is highly recommended to provide a gobo sample and gobo holder/wheel sample from the xture to the custom gobo vendor for accurate sizing. Gobo specications below including diameter, thickness, and materials have been tested and are compatible in this xture.
Using custom gobos that do not match the gobo specications below, is not recommended and any damage to the xture as a result of using a custom gobo is NOT covered under warranty. Extended testing of custom gobo designs is highly recommended prior to using.
PLEASE CONTACT ADJ CUSTOMER SUPPORT FOR FURTHER INFORMATION.
ROTATING GLASS GOBOS
Gobo O.D. (Max. Outer Diameter) ø9.7mm
Gobo I.D. (Max. Image Diameter) ø6.5mm
Gobo Holder Diameter ø10mm
Gobo Thickness ø0.5mm
Gobo Material BOROFLOAT
Hydro Beam X2 Gobos
GOBO 1 GOBO 2 GOBO 3 GOBO 4 GOBO 5 GOBO 6
GOBO 7 GOBO 8 GOBO 9 GOBO 10 GOBO 11
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 17
Hydro Beam X2 Gobo Installation
GOBO INSTALLATION
WARNING! GOBO REPLACEMENT SHOULD ONLY BE DONE BY A TRAINED TECHNICAN.
TURN OFF POWER AND ALLOW APPROXIMATELY 60 MINUTES FOR THE FIXTURE TO COOL DOWN.
Unscrew and remove the 8 screws that secure the moving head shells.
4 x Screws Total 2 x Screws on each side
4 x Screws Total 2 x Screws on each side
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 18
Hydro Beam X2 Gobo Installation
4 x Screws Total 2 x Screws on each side
4 x Screws Total 2 x Screws on each side
Unscrew and remove the 8 screws that secure the moving head shells.
Remove both moving head shells
10 x Screws Total 5 x Screws on each side
After the moving head shells have been removed unscrew and remove the 10 screws that secure the head in place. Carefully remove the head to access the inside module.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 19
Hydro Beam X2 Gobo Installation
Guard Plate
2 x Screws
Guard Plate
Note: Disconnect the cables with RED sleeves before dismantling head module.
Head Module
Carefully remove the Head Module.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 20
Hydro Beam X2 Gobo Installation
Note: Make sure the retainer spring is secure.
Unscrew and remove the 4 screws
that secure the Insulation Board.
4 x Screws Total
Insulation Board
Carefully remove the Insulation Board
Gobo
Carefully lift the GOBO holder up and out from the GOBO wheel.
Retainer Spring
Gobo Replacement: The GOBO is secured into the gobo housing by a retainer spring. Carefully remove the retainer spring that holds the GOBO in place. Carefully remove the GOBO from the GOBO holder. Replace with your desired GOBO, and reinsert the retainer spring into place.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 21
Hydro Beam X2 Fixture Installation
F I XTU R E I N S T A LLA T I O N
Keep fixture at least 5.0 feet (1.5m) away from any
flammable materials, decorations, pyrotechnics, etc.
ELEC TRI C AL CONNE C T I ONS
A q ualif ied electri c i an shou l d b e used for all
electri cal c o nnect ions and/ o r i nstalla t i o ns.
MINIMUM DISTANCE TO OBJECTS/SURFACES
M UST BE 40 F EET ( 12 M E T ERS)
FLAMMA B LE M ATER I AL W A RNI N G
MAXIMUM TEMPERATURE OF EXTERNAL SURFACE
212° F ( 100° C )
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and
construction codes and regulations. Before rigging/mounting the fixture to any metal
truss/structure or placing the fixture on any surface, a professional equipment installer
MUST be consulted to determine if the metal truss/structure or surface is properly certified
to safely hold the combined weight of the fixture, clamps, cables, and accessories.
Overhead fixture installation must always be secured with a secondary safety attachment,
such as an appropriately rated safety cable that meets all local, national, and country codes
and regulations.
Fixture ambient operating temperature range is -4° to 113°F. (-20° to 45°C)
Do not use this fixture outside this temperature range.
Fixture should be installed in areas outside walking paths, seating areas, or away from areas
were unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture when rigging, removing, or servicing.
Allow approximately 60 minutes for the fixture to cool down before servicing.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 22
Hydro Beam X2 Fixture Installation
NOTICE: The suitable enviromental temperature for this lighting xture is between -25˚ C to 45˚ C.
Do not place this lighting xture in an enviroment where the temperatures are under or above the temperatures stated above. This will allow the xture to run at its best and help prolong the xture life.
CLAMP
SAFETY CABLE
Screw one clamp via a M12 screw and nut into the Omega holder. Insert the quick-lock fasteners of the Omega holder into the respective holes of the adjustable mounting bracket. Tighten the quick-lock fasteners fully clockwise. Pull the safety-cable through the opening located on the bottom of the unit and over the trussing system or a safe xation spot. Insert the end in the carabine and tighten the safety screw.
OMEGA BRACKET
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 23
Hydro Beam X2 Fixture Installation
When installing the unit, the trussing or area of installation must be able to hold 10 times the weight without any deformation. When installing the unit must be secured with a secondary safety attachment, e.g. and appropriate safety cable. Never stand directly below the unit when mounting, removing, or
servicing the unit.
Overhead mounting requires extensive experience, including calculating working load limits, installation material being used, and perodic safety inspection of all installation material and unit. If you lack these qualications, do not attempt the installation yourself.
These installaiton should be checked by a skilled person once a year.
LCD CONTROL DISPLAY
CABLES DOWN
* S I D E M OUNT I N G
TO MAINTAIN IP65 RATING INTEGRITY, FIXTURE
MUST BE INSTALLED WITH CABLES FACING THE
GROUND AT ALL TIMES. WATER MUST EASILY
RUN OFF AND NOT COLLECT AROUND CABLE
CONNECTIONS.
LCD CONTROL DISPLAY
CABLES DOWN
* S A FETY CABL E
ALWAYS ATTACH A SAFETY CABLE WHENEVER
INSTALLING THIS FIXTURE IN A SUSPENDED
ENVIRONMENT TO ENSURE THE FIXTURE WILL
NOT DROP IF THE CLAMP FAILS.
The Hydro Beam X2 is fully operational in three dierent mounting positions, hanging upside-down, mounted sideways on trussing, or set on a at level surface. Be sure this xture is kept at least 12m (40ft) away from any ammable materials (decoration etc.). Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails (see next page). Never use the carrying handles for secondary attachment.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 24
Hydro Beam X2 Connections
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 25
Hydro Beam X2 DMX Set Up
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication
between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The Hydro Beam X2 can be controlled via DMX-512 protocol. Your unit and your DMX controller requires a 5-pin XLR connector for data input and data output. We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Special Note: Line Termination.
on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED AND ONLY IP65 RATED POWER AND DATE CABLES MUST BE USED.
When longer runs of cable are used, you may need to use a terminator
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 26
Hydro Beam X2 DMX Addressing
DMX ADDRESSING
All xtures should be given a DMX starting address when using a DMX controller, so the correct xture responds to the correct control signal. This digital starting address is the channel number from which the xture starts to “listen” to the digital control signal sent out from the DMX controller. The assignment of this starting DMX address is achieved by setting the correct DMX address on the digital control display on the xture.
You can set the same starting address for all xtures or a group of xtures, or set dierent addresses for each individual xture. Setting all xtures to the same DMX address will cause all xtures to react in the same way, in other words, changing the settings of one channel will aect all the xtures
simultaneously.
If you set each xture to a dierent DMX address, each unit will start to “listen” to the channel number you have set, based on the quantity of DMX channels of each xture. That means changing the settings of one channel will only aect the selected xture.
In the case of the Hydro Beam X2, when in 15 Channel you should set the starting DMX address of the rst unit to 1, the second unit to 16 (15 + 1), the third unit to 31 (16 + 15), and so on. (See the chart below for more details.)
Channel Mode
15 Channels 1 16 31 46
17 Channels 1 18 35 52
Unit1
Address
Unit2
Address
Unit3
Address
Unit4
Address
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 27
Hydro Beam X2 DMX Channel Modes
15 Channels 17 Channels Values
1 1
2
2 3
4
3 5
000-255
000-255
000-255
000-255
000-007 008-009 010-011 012-013 014-015 016-017 018-019 020-021 022-023 024-025 026-027 028-029 030-031 032-033 034-035 036-037 038-039 040-041 042-043 044-045 046-047 048-049 050-051 052-053 054-055 056-057 058-059 060-061 062-063 064-127 128-189 190-193 194-255
Functions
PAN MOVEMENT 8-BIT:
Pan Movement (0° - 540°)
PAN FINE 16-BIT:
Fine Control of Pan Movement
TILT MOVEMENT 8-BIT:
Tilt Movement (0° - 270°)
TILT FINE 16-BIT:
Fine Control of Tilt Movement
COLOR WHEEL:
Open / White White + Red Red Red + Orange Orange Orange + Light Blue Light Blue Light Blue + Green Green Green + Light Green Light Green Light Green + Purple Purple Purple + Pink Pink Pink + Yellow Yellow Yellow + Magenta Magenta Magenta + Blue Blue Blue + Red/Green/Blue/Orange (Quad) Red/Green/Blue/Orange (Quad) Red/Green/Blue/Orange (Quad) + CTO-3200K CTO-3200K CTO-3200K + CTO-5600K CTO-5600K CTO-5600K + UV UV Color Wheel Indexing Clockwise Rotation Fast - Slow Stop Clockwise Rotation Slow - Fast
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 28
Hydro Beam X2 DMX Channel Modes
15 Channels 17 Channels Values
000-009 010-014 015-019 020-024 025-029 030-034 035-039 040-044 045-049 050-054 055-059
4 6
5 7
6 8
7 9
8 10
9 11
060-063 064-068 069-073 074-078 079-083 084-088 089-093 094-098 099-103 104-108 109-113 114-118 119-127 128-189 190-193 194-255
000-127 128-189 190-193 194-255
000-007 008-255
000-127 128-189 190-193 194-255
000-007 008-255
000-127 128-189 190-193 194-255
Functions
GOBO WHEEL:
Open Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo 11 Open Shake Gobo 1 Shake Gobo 2 Shake Gobo 3 Shake Gobo 4 Shake Gobo 5 Shake Gobo 6 Shake Gobo 7 Shake Gobo 8 Shake Gobo 9 Shake Gobo 10 Shake Gobo 11 Shake Clockwise Rotation Fast - Slow Stop Counter-Clockwise Rotation Slow - Fast
ROTATING GOBO:
Indexing Clockwise Rotation Fast - Slow Stop Counter-Clockwise Rotation Slow - Fast
PRISM 1 (6 FACET LINEAR):
Close Open
ROTATING PRISM 1 (6 FACET LINEAR):
Indexing Counter-Clockwise Rotation Fast - Slow Stop Clockwise Rotation Slow - Fast
PRISM 2 (8 FACET CIRCULAR):
Close Open
ROTATING PRISM 2 (8 FACET CIRCULAR):
Indexing Counter-Clockwise Rotation Fast - Slow Stop Clockwise Rotation Slow - Fast
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 29
Hydro Beam X2 DMX Channel Modes
15 Channels 17 Channels Values
000-031 032-063
10 12
11 13
12 14
13 15
14 16
15 17
064-095 096-127 128-159 160-191 192-223 224-255
000-007 008-255
000-255
000-069 070-079 080-089 090-099 100-109 110-119 120-129 130-139 140-149 150-159 160-179 180-189 190-199 200-209 210-229 230-239 240-255
Functions
SHUTTER & STROBING:
Close Open Strobing Slow - Fast Open Pulsating Strobe Slow - Fast Open Random Strobing Open
MASTER DIMMER:
0% - 100% 000-255
FOCUS:
0% - 100%000-255
FROST:
Off On
PAN/TILT MOVEMENT SPEED:
Fast - Slow
SPECIAL FUNCTIONS:
No Function Blackout W/ Pan/Tilt Movement Enabled Blackout W/ Pan/Tilt Movement Disabled Blackout W/ Color Wheel Movement Enabled Blackout W/ Color Wheel Movement Disabled Blackout W/ Gobo Wheel Movement Enabled Blackout W/ Gobo Wheel Movement Disabled Lamp On Reset Pan & Tilt Motors Reset Effect Motors No Function Lamp Full Power Lamp Half Power Reset All No Function Lamp Off No Function
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 30
Hydro Beam X2 System Menu
SYSTEM MENU
The xture includes an easy to navigate system menu control panel display where all necessary settings and adjustments are made. (See image below) During normal operation, pressing the MENU button once will access the xture’s main menu. Once in the main menu, you can navigate through the dierent functions and access the sub-menus with the UP and DOWN buttons. When you reach a eld that requires adjusting, press the ENTER button to access that eld and use the UP and DOWN buttons to adjust the eld. Pressing the ENTER button once more will conrm your setting. You may exit the main menu at any time without making any adjustments by pressing the MENU
button.
SYSTEM LOCK/UNLOCK: When the display lock function is activated, the display and system menu will lock after 10 seconds of no activity. To UNLOCK the display, press and HOLD the MENU button for 10+ seconds. While pressing the MENU button, a timer will appear at the bottom of the display indicating the pass­ing seconds from 0-9. Once the timer reaches 9 seconds, the display will unlock allowing access to
the system menu.
DO NOT RELEASE THE MENU BUTTON UNTIL THE DISPLAY IS UNLOCKED.
If the MENU button is released before the timer reaches 9 seconds and/or is unlocked, the display will not unlock and the time will be reset.
NOTE: The timer will not appear in the display if the lock function is disabled.
MENU
ENTER
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 31
Hydro Beam X2 System Menu
MENU OPTIONS DESCRIPTIONSUBMENU
DMX SETTINGS
PERSONALITY
MANUAL CONTROL
DMX Address
DMX CH Mode
No DMX Status
Select Signal
Status Settings
WiFly Settings
Reset Motors
Display
Service
Pan Tilt Color Gobo RGobo Prism1 RPrism1 Prism2 RPrism2 Shutter Dimmer Frost Focus
001-512
15Ch / 17Ch
Hold Last / Blackout / Manual
DMX: Yes / No
WiFly: Yes / No
WiFly and DMX Out: Yes / No
Pan Invert: On / Off
Tilt Invert: On / Off
P./T. Feedback: On / Off
Pan Degree: 540
P./T. Speed: Speed 1 / Speed 2
Hibernation: Off / 01M~99M / 15M
Set WiFly Channel: 00~14
Enable / Disable WiFly
Reset All Motors: Yes / No
Pan/Tilt Reset: Yes / No
Color Reset: Yes / No
Gobo/R-G Reset: Yes / No
Prism1/R-P1 Reset: Yes / No
Prism2/R-P2 Reset: Yes / No
Shutter Reset: Yes / No
Focus Reset: Yes / No
Frost Reset: Yes / No
Intensity: 1~10 (Dimmest-Brightest)
Display Invert: Yes / No
Screen Saver Delay: Off~10M Lock On/Off: On / Off
Calibration
Pass Code = 050
000-255 000-255 000-255 000-255 000-255 000-255 000-255 000-255 000-255 000-255 000-255 000-255 000-255
(Pass Code = 050)
Factory Restore: Yes / No (Pass Code = 011)
DMX Addressing
DMX Channel Mode Selection
DMX Lost Status
Control via DMX
Control via WiFly Control via WiFly and send
DMX Out via DMX cable Reverse Pan Motion
Reverse Tilt Motion
Pan/Tilt Movement Feedback
Pan Degree
Pan/Tilt Movement Speed
Sleep Setting (No Activity)
Set WiFly Wireless Channel
Activate / Deactivate WiFly
Reset All Motors
Reset the Pan & Tilt Motors
Reset the Color Wheel Motor
Reset the Gobo Wheel Motors
Reset the Prism 1 Motors
Reset the Prism 2 Motors
Reset the Shutter Motor
Reset the Focus Motor
Reset the Frost Motor
Display Brightness
Display Readout Inversion
Display Shutoff Time Display Lock
Calibration Adjustment
Restore Factory Settings
Manual Control
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 32
Hydro Beam X2 System Menu
MENU OPTIONS DESCRIPTIONSUBMENU
INFORMATION
Fixture Life Time
Total Lamp Time
Fixture Temps
Power On Time: XXXXXX Hours
P-On Time-R: XXXXXX Hours
P-On Time Reset: Pass Code = 050
Lamp On Time - XXXXXX Hours
Lamp On Time-R - XXXXXX Hours
Lamp On Time Reset: Pass Code = 050
LampLifeTime: XXX%
Current: XXX ˚F / XXX ˚C
Max Resettable: XXX ˚F / XXX ˚C
Head
Max Not Resettable: XXX ˚F / XXX ˚C
Current: XXX ˚F / XXX ˚C
Max Resettable: XXX ˚F / XXX ˚C
Base
Max Not Resettable: XXX ˚F / XXX ˚C
Reset Head Temp: Yes / No (Pass Code = 050)
Reset Base Temp: Yes / No (Pass Code = 050)
Total Running Time (Not Resettable)
Total Running Time (Resettable)
Reset P-On Time-R (Total Running Time)
Lamp On Time (Not Resettable)
Lamp On Time (Resettable)
Reset Lamp On Time-R (Lamp On Time)
Current Lamp Life Percentage
Current Head Temperature
Maximum Temperature
(1)
Reached (Resettable)
(See Note 1)
(2)
Maximum Temperature Reached (Not Resettable)
(See Note 2)
Current Base Temperature
(1)
Maximum Temperature Reached (Resettable)
(See Note 1)
Maximum Temperature
(2)
Reached (Not Resettable)
(See Note 2)
Reset Head Temperature (Max Resettable)
Reset Base Temperature (Max Resettable)
Humidity
Fan Info. (RPM)
DMX Values
(See Note 3)
(3)
Head Humidity: XXX%
Base Humidity: XXX%
Base Fan 1: XXXX Base Fan 2: XXXX Base Fan 3: XXXX Arm Fan 1: XXXX Arm Fan 2: XXXX Head Fan 1: XXXX Head Fan 2: XXXX Head Fan 3: XXXX Head Fan 4: XXXX Head Fan 5: XXXX Head Fan 6: XXXX Head Fan 7: XXXX
Pan / Pan Fine / Tilt / Tilt Fine / Color / Gobo / RGobo / Prism1 / RPrism1 / Prism2 / RPrism2 / Shutter / Dimmer / Focus / Frost / P/T Speed /
Current Head Humidity
Current Base Humidity
Base Fan 1 Speed Base Fan 2 Speed Base Fan 3 Speed Arm Fan 1 Speed Arm Fan 2 Speed Head Fan 1 Speed Head Fan 2 Speed Head Fan 3 Speed Head Fan 4 Speed Head Fan 5 Speed Head Fan 6 Speed Head Fan 7 Speed
Current DMX Values
Spe. Func
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 33
Hydro Beam X2 System Menu
MENU OPTIONS DESCRIPTIONSUBMENU
INFORMATION
Error Logs
Fixture Errors (Listed Errors One by One)
Reset Error Log: Yes / No (Pass Code = 050)
Software Version Current Software VersionX.XX
Last 10 Fixture Error Codes
Clear the Error Log
Lamp ON / OFF
Lamp ON
LAMP CONTROL
Notes: (1) Current Maximum Temperature - Maximum fixture temp. that has been recorded, before reset and after reset. (2) Maximum Temperature - Overall maximum fixture temp. that has been recorded. (Not Resettable) (3) DMX Value options depend on the DMX Channel mode the fixture is set to
with Power
Lamp ON via DMX On / Off
Lamp OFF via DMX On / Off
On / Off
On / Off
Lamp On/Off
Lamp ON when Power ON
Lamp Power ON via DMX
Lamp Power OFF via DMX
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 34
Hydro Beam X2 System Menu
DMX SETTINGS - The submenus listed under DMX SETTINGS are as follows: DMX Address, DMX Channel Mode, No DMX Status, and Select Signal.
- DMX ADDRESS - In this submenu you can use the UP or DOWN buttons to adjust and nd your
desired DMX address.
- DMX CHANNEL MODE - In this submenu you can use the UP or DOWN buttons to nd your desired DMX channel mode.
- NO DMX STATUS - This submenu setting is used as a precaution mode in case the DMX signal is lost or interrupted. The operating mode chosen in this submenu is the running mode the xture will go into when the DMX signal is lost. Listed below are the 2 modes.
HOLD - This setting will have the xture stay in the last DMX setup.
BLACKOUT - This setting will have the xture automatically go into stand by mode.
MANUAL - This setting will go into the current manual control set up. See MANUAL CONTROL.
PERSONALITY - The submenus listed under PERSONALITY are as follows: Select Signal, Status Settings, WiFly Settings, Reset Motors, Display, and Service.
- SELECT SIGNAL - In this submenu you can select your desired DMX control mode:
DMX - Control the unit via DMX cable connection.
WiFly - Control the unit via WiFly connection.
WiFly / DMX Out - Control the unit via WiFly connection. The DMX signal is sent to the next unit via DMX cable.
- STATUS SETTINGS - In this submenu you are able to access and adjust/change: Pan Invert, Tilt Invert, P./T. Feedback, Pan Degree, P./T. Speed, and Hibernation.
- WIFLY SETTINGS - In this submenu you are able to access and adjust/change: WiFly Channel and Enable/Disable WiFly.
- RESET MOTORS - In this submenu you are able to reset selected motors.
- DISPLAY - In this submenu you are able to access and adjust/change: Backlight Intensity, Display
Invert, Screen Saver Delay, and Display Lock.
- SERVICE - In this submenu you are able to access and adjust/change: the calibration (eect adjust) and restore the factory settings.
MANUAL CONTROL - This menu is for manual testing and manual control. Pan, tilt, color wheel, gobo wheel, gobo rotation, prism 1, prism 1 rotation, prism 2, prism 2 rotation, shutter, dimmer, frost, and focus can all be tested/adjusted.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 35
Hydro Beam X2 System Menu
INFORMATION - The submenus listed under INFORMATION are as follows: Fixture Life Time, Total Lamp Time, Fixture Temps, Humidity, Fan Info. (RPM), DMX Values, Error Logs, and Software Version.
- FIXTURE LIFE TIME
Power On Time -The TOTAL power ON running time of the unit is displayed. This time CANNOT be reset. Reminder: The displayed time represents the TOTAL POWER ON time.
P-On Time-R - The CURRENT power ON running time of the unit is displayed. This running time may not be the same as the total power ON running time displayed under “Power On Time”. This
time CAN be reset. Reminder: The displayed time represents the CURRENT POWER ON TIME since the last reset.
P-On Time Reset - Reset the CURRENT power ON running time that is displayed under “P-On Time-R”.
- TOTAL LAMP TIME
Lamp On Time - The TOTAL Lamp ON time is displayed. This total lamp ON time CANNOT be reset. Reminder: The displayed time represents the TOTAL LAMP ON time.
Lamp On Time-R - The CURRENT LED ON running time is displayed. This running time may not be the same as the total lamp ON time displayed under “Lamp On Time”. This total lamp ON
time CAN be reset. Reminder: The displayed time represents the CURRENT LAMP ON time since the last reset.
Lamp On Time Reset - With this function you can reset the CURRENT lamp ON time that is displayed under “Lamp On Time-R”.
LampLifeTime - With this function you can check the current lamp life percentage.
- FIXTURE TEMPS
Head Current - Current temperature of the moving head is displayed. Max Resettable - Maximum moving head temperature that has been recorded, before reset
and after reset. (Resettable)
Max Not Resettable - Overall maximum moving head temperature that has been recorded. (Not Resettable)
Base Current - Current temperature of the base is displayed.
Max Resettable - Maximum base temperature that has been recorded, before reset and after reset. (Resettable) Max Not Resettable - Overall maximum moving head temperature that has been recorded. (Not Resettable)
Reset Head Temp - Reset the “MAX RESETTABLE” moving head temperature. (Pass Code is “50”)
Reset Base Temp - Reset the “MAX RESETTABLE” base temperature. (Pass Code is “50”)
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 36
Hydro Beam X2 System Menu
- HUMIDITY Head Humidity - The current humidity of the moving head is displayed.
Base Humidity - The current humidity of the base is displayed.
- FAN INFO. (RPM) Base Fan1 - Current speed of base fan 1 is displayed.
Base Fan2 - Current speed of base fan 2 is displayed.
Base Fan3 - Current speed of base fan 3 is displayed.
Arm Fan1 - Current speed of arm fan 1 is displayed.
Arm Fan2 - Current speed of arm fan 2 is displayed.
Head Fan1 - Current speed of moving head fan 1 is displayed.
Head Fan2 - Current speed of moving head fan 2 is displayed.
Head Fan3 - Current speed of moving head fan 3 is displayed.
Head Fan4 - Current speed of moving head fan 4 is displayed.
Head Fan5 - Current speed of moving head fan 5 is displayed.
Head Fan6 - Current speed of moving head fan 6 is displayed.
Head Fan7 - Current speed of moving head fan 7 is displayed.
- DMX Values - Displays the DMX values of any DMX channel that is currently in use.
- Error Logs - Displays any error codes.
- Software Version - Current software version is displayed.
LAMP CONTROL - The submenus listed under LAMP CONTROL are as follows: Lamp ON/OFF, Lamp ON with Power, Lamp ON via DMX, and Lamp OFF via DMX.
- Lamp ON/OFF - Turn the lamp On/O.
- Lamp ON with Power - Lamp powers “ON” when power is applied.
- Lamp ON via DMX - Power lamp “ON” using a DMX controller.
- Lamp OFF via DMX - Power lamp “OFF” using a DMX controller.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 37
Hydro Beam X2 WiFly Control
BEFORE SETTING THE WIRELESS CHANNEL ON ANY WIFLY FIXTURE, MAKE SURE THE SOURCE WIFLY WIRELESS DMX TRANSCEIVER DEVICE IS OFF.
With this feature you are able to control the unit with DMX without the need of XLR cables. Your DMX controller must be connected to a ADJ WiFly Transceiver to use this function. You are able to communicate up to 2500 feet/760 meters (open line of sight).
1. Ensure the source WiFly wireless DMX Transceiver device is powered OFF.
2. Power ON the fixture and using the control panel scroll to the PERSONALITY menu and press
ENTER. Use the UP and DOWN buttons to highlight the WIFLY SETTINGS submenu and press ENTER.
3. Using the UP and DOWN buttons, highlight ENABLE/DISABLE WIFLY. Press the ENTER button to toggle between ENABLE & DISABLE. Press ENTER so that “Enable” is displayed.
4. Next highlight SET WIFLY CHANNEL and press ENTER. Use the UP and DOWN buttons to find your desired WiFly address and press ENTER to confirm.
NOTE: Erratic fixture movement may occur if other WiFly wireless DMX products are in use in the same area and are using the same WiFly wireless channel. When WiFly is enabled, the fixture may immediately start to respond to the DMX wireless signal from another WiFly wireless DMX Transceiver. Make sure to know what WiFly wireless channels are being used in the area where the fixture is being used.
ADJ WIFLY WIRELESS TRANSCEIVER only has 0-14 wireless channels, NO CH 15.
5. Press the MENU button to exit out of the WIFLY SETTINGS submenu. Press the UP button so that SELECT SIGNAL is highlighted and press ENTER. Press the DOWN button to highlight WIFLY and press ENTER. Select YES and press ENTER to confirm.
6. Set your desired DMX address in the DMX ADDRESS submenu of the DMX SETTINGS main system menu. Set your desired DMX channel mode in the DMX CH MODE submenu of the DMX SETTINGS main system menu.
7. Repeat this process for all WiFly compatible fixtures in the WiFly wireless network, making sure all fixtures are assigned the same WiFly wireless channel.
8. After all fixtures in the WiFly wireless network have been set to the same WiFly wireless channel and powered ON, power ON the source WiFly DMX Transceiver device.
4. Test all fixtures connected to the WiFly wireless network to confirm proper functionality.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 38
Hydro Beam X2 WiFly Control
WIRELESS WIFLY INSTALLATION LOCATION GUIDELINES
Wireless DMX signal can penetrate walls, glass, metal, and most objects. However, there are many factors that can aect and/or interrupt the wireless DMX signal, one of which is people. Therefore, it is highly recommended to position the wireless antenna a minimum of 9.8 ft. (3m) above audiences and/or above ground level. Careful planning and testing of the selected installation location is critical to ensure optimum and reliable wireless DMX operation.
9.8 ft (3m)
Above Ground
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 39
Hydro Beam X2 Error Codes
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Printerrormessage Description
Lamp Hot Power Off Lamp Hot Power Off
CPU-B Error CPU-B Error
CPU-C Error CPU-C Error
CPU-D Error CPU-D Error
CPU-E Error CPU-E Error
Pan Reset Error
Pan Encoder Error
Tilt Reset Error
Tilt Encoder Error
Color Reset Error Color: Reset Error
Gobo Reset Error Gobo: Reset Error
RGobo Reset Error RGobo: Reset Error
Prism1 Reset Error Prism1: Reset Error
RPrism1 Reset Error RPrism1: Reset Error
Prism2 Reset Error Prism2: Reset Error
Pan: Reset Error
Pan: Encoder Error
Tilt: Reset Error
Tilt: Encoder Error
16
17
18
19
20
21
22
23
24
25
26
27
28
29
RPrism2 Reset Error RPrism2: Reset Error
Focus Reset Error Focus: Reset Error
Base Fan 1 start Errors
Base Fan 1 stop Errors
Base Fan 1 Too Low Errors
Base Fan 1 Too High Errors
Base Fan 2 start Errors
Base Fan 2 stop Errors
Base Fan 2 Too Low Errors
Base Fan 2 Too High Errors
Base Fan 3 start Errors
Base Fan 3 stop Errors
Base Fan 3 Too Low Errors
Base Fan 3 Too High Errors
Base Fan 1 Can’t Start
Base Fan 1 Can’t Stop
Base Fan 1 speed Too low
Base Fan 1 speed Too high
Base Fan 2 Can’t Start
Base Fan 2 Can’t Stop
Base Fan 2 speed Too low
Base Fan 2 speed Too high
Base Fan 3 Can’t Start
Base Fan 3 Can’t Stop
Base Fan 3 speed Too low
Base Fan 3 speed Too high
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 40
Hydro Beam X2 Error Codes
30
31 Side Fan 1 stop Errors
32 Side Fan 2 start Errors
33 Side Fan 2 stop Errors
34 Lamp Fan 1 start Errors
35 Lamp Fan 1 stop Errors
36 Lamp Fan 1 Too Low Errors
37 Lamp Fan 1 Too High Errors
38 Lamp Fan 2 start Errors
39 Lamp Fan 2 stop Errors
40 Lamp Fan 2 Too Low Errors
41 Lamp Fan 2 Too High Errors
42 Lamp Fan 3 start Errors
43 Lamp Fan 3 stop Errors
44 Lamp Fan 3 Too Low Errors
45 Lamp Fan 3 Too High Errors
46 Lamp Fan 4 start Errors
47 Lamp Fan 4 stop Errors
48 Lamp Fan 4 Too Low Errors
49 Lamp Fan 4 Too High Errors
50 Lamp Fan 5 start Errors
51 Lamp Fan 5 stop Errors
52 Lamp Fan 5 Too Low Errors
53 Lamp Fan 5 Too High Errors
54 Lamp Fan 6 start Errors
55 Lamp Fan 6 stop Errors
56 Lamp Fan 6 Too Low Errors
57 Lamp Fan 6 Too High Errors
58 Lamp Fan 7 start Errors
59 Lamp Fan 7 stop Errors
60 Lamp Fan 7 Too Low Errors
61 Lamp Fan 7 Too High Errors
Printerrormessage Description
Side Fan 1 start Errors
Side Fan 1 Can’t Start
Side Fan 1 Can’t Stop
Side Fan 2 Can’t Start
Side Fan 2 Can’t Stop
Lamp Fan 1 Can’t Start
Lamp Fan 1 Can’t Stop
Lamp Fan 1 speed Too low
Lamp Fan 1 speed Too high
Lamp Fan 2 Can’t Start
Lamp Fan 2 Can’t Stop
Lamp Fan 2 speed Too low
Lamp Fan 2 speed Too high
Lamp Fan 3 Can’t Start
Lamp Fan 3 Can’t Stop
Lamp Fan 3 speed Too low
Lamp Fan 3 speed Too high
Lamp Fan 4 Can’t Start
Lamp Fan 4 Can’t Stop
Lamp Fan 4 speed Too low
Lamp Fan 4 speed Too high
Lamp Fan 5 Can’t Start
Lamp Fan 5 Can’t Stop
Lamp Fan 5 speed Too low
Lamp Fan 5 speed Too high
Lamp Fan 6 Can’t Start
Lamp Fan 6 Can’t Stop
Lamp Fan 6 speed Too low
Lamp Fan 6 speed Too high
Lamp Fan 7 Can’t Start
Lamp Fan 7 Can’t Stop
Lamp Fan 7 speed Too low
Lamp Fan 7 speed Too high
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 41
Hydro Beam X2 Dimensional Drawings
*NOT TO SCALE
14.65” / 372mm
10.4” / 264mm
21.5” / 547.2mm
14.65” / 372mm
16.5” / 419.5mm
MENU
ENTER
10.4” / 264mm
24.8” / 630mm
MENU
ENTER
15.8” / 402mm
19” / 482mm
13” / 330mm
5.5” / 140mm
5.5” / 140mm
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 42
Hydro Beam X2 Multiple Unit Power Linking
With this feature you can connect the xtures to one another using the power cable input and
output sockets. NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
Hydro Beam X2 Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be car­ried out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
3. Always be sure to dry all parts completely before plugging the unit back in. Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue, dust, dew).
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 43
Hydro Beam X2 Limited Warranty (USA Only)
MANUFACTURER’S LIMITED WARRANTY
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing
defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service you must obtain a Return Authorization number (RA#) before sending back the product–please
contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in it’s original package. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified in any manner
which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the
instruction manual.
D. This is not a service contract, and this warranty does not include maintnance, cleaning or periodic check up.
During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or
replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this
warranty were manufactured after August 15, 2012, and bear indentifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without
any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products
described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product.
This warranty is the only written warranty applicable to ADJ Products, LLC Products and supersedes all prior warranties
and written descriptions of warranty terms and conditions heretofore published.
MANUFACTURER’S LIMITED WARRANTY PERIODS:
• Non L.E.D. Lighting Products = 1-year (365 days) Limited Warranty (Such as: Special Effect Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
• Laser Products = 1 Year (365 Days) Limited Warranty (excluding laser diodes which have a 6 month limited warranty)
• L.E.D. Products = 2-year (730 days) Limited Warranty (excluding batteries which have a 180 day limited warranty).
Note: 2 Year Warranty only applies to purchases within the United States.
• StarTec Series = 1 Year Limited Warranty (excluding batteries which have a 180 day limited warranty).
• ADJ DMX Controllers = 2 Year (730 Days) Limited Warranty
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 44
Hydro Beam X2 Technical pecifications
Voltage: 100V ~ 240V/50~60Hz IP Rating: IP65 Lamp: Osram Sirius HRI 370W LL Discharge Lamp Color Temperature: 7800K Power Draw: 540W Weight: 64 lbs./ 29 kgs. Dimensions: 15.8” (L) x 16.5” (W) x 24.8” (H) 402 x 419.5 x 630mm Gobos: 11 Gobos + Open Prisms: 2 Prisms (1 x 6 Facet Linear & 1 x 8 Facet Circular) DMX Channels: 2 DMX Modes: 15 / 17 Warranty: 2 Year (730 days)
* May vary depending on several factors including but not limited to:
Enviromental Conditions, Power/Voltage, Usage Patterns (On-O Cycling), Control, and Dimming.
Please Note: Specications and improvements in the design of this unit and this manual are subject to change without notice.
ADJ Products, LLC - www.adj.com - Hydro Beam X2 User Manual Page 45
Loading...