Flat Par Tri7X

Unpacking: Thank you for purchasing ican DJ®. Every Flat Par Tri7X has bee been shipped in perfect operating condit ping carton for damage that may have oc carton appears to be damaged, carefull damage and be sure all accessories nec arrived intact. In the case damage has b ing, please contact our toll free custom instructions. Do not return this unit to you ing customer support.

Introduction: The American DJ® Flat P pursuit to create high quality intelligent li

DMX intelligent, high powered LED par fi in a stand alone mode or connected in

This wash has five operating modes: Sou RGB mode, Static Color mode and DMX

Customer Support: American DJ prov

to provide set up help and to answer any

ter problems during your set up or initial

us on the web at www.American DJ.com

tions. Service Hours are Monday through

Pacific Standard Time.

Voice:

(323) 582-3322

Fax:

(323) 582-3108

E-mail:

support@American

Warning! To prevent or reduce the risk not expose this unit to rain or moisture.

Caution! There are no user serviceable attempt any repairs yourself, doing so wil ranty. In the unlikely event your unit may r American DJ.

PLEASE recycle the shipping carton w

©American DJ® - www.Americandj.com - Fla

Flat Par Tri7X

General Instructions

To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.

Flat Par Tri7X

Features

Mulit-Colors

Five Operating Modes

Electronic Dimming 0-100%

Built in Microphone

DMX-512 protocol

3-Pin DMX Connection

Seven DMX Modes: 1 Channel Mode, 2 Channel Mode, 3 Channel

Mode, 4 Channel Mode, 5 Channel Mode, 6 Channel Mode, and 7 Channel Mode.

ADJ LED RC compatiable (Not Included)

Power Cord Daisy Chain (See page 17)

Flat Par Tri7X

Warranty Registration

The Flat Par Tri7X carries a 3 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All packages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the shipper.

Flat Par Tri7X

To reduce the risk of electrical shock o rain or moisture

Do not spill water or other liquids into o

Do not attempt to operate this unit if th frayed or broken. Do not attempt to re prong from the electrical cord. This pro of electrical shock and fire in case of a

Disconnect from main power before ma

Do not remove the cover under any co serviceable parts inside.

Never operate this unit when it’s cover

Never plug this unit in to a dimmer pac

Always be sure to mount this unit in an ventilation. Allow about 6” (15cm) betw

Do not attempt to operate this unit, if it

This unit is intended for indoor use onl doors voids all warranties.

During long periods of non-use, discon

Always mount this unit in safe and stab

Power-supply cords should be routed be walked on or pinched by items plac paying particular attention to the point

Cleaning -The fixture should be cleane the manufacturer. See page 18 for clea

Heat -The appliance should be situate such as radiators, heat registers, stove ding amplifiers) that produce heat.

The fixture should be serviced by qual

A.The power-supply cord or the plug

B.Objects have fallen, or liquid has be

C.The appliance has been exposed to

D.The appliance does not appear to o marked change in performance.

©American DJ® - www.Americandj.com - Flat Par Tri7X User Manual Page 3

©American DJ® - www.Americandj.com - Fla

Figure 1
Termination reduces signal err avoids signal transmission pr and interference. It is always a to connect a DMX terminal, (Re 120 Ohm 1/4 W) between PIN 2 and PIN 3 (DMX +) of the last

Flat Par Tri7X

Set Up

Power Supply: The American DJ Flat Par Tri7X contains a automatic voltage switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.

DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).

DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several

DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

The Flat Par Tri7X can be controlled via DMX-512 protocol. The Flat Par Tri7Xhas7DMXchannelmodes,pleaseseepage9forthedifferentDMX modes. The DMX address is set on the back panel of the Flat Par Tri7X. Your unit and your DMX controller require a stan-

dard 3-pin XLR connector for data input and data output (Figure 1). We recommend Accu-Cable

DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.

©American DJ® - www.Americandj.com - Flat Par Tri7X User Manual Page 5

Flat Par Tri7X

Notice: Be sure to follow figures two and cables. Do not use the ground lug on the nect the cable’s shield conductor to the conductor to come in contact with the X the shield could cause a short circuit and

 

 

 

 

COMMON

 

DMX512 OUT

1

3

DMX +

 

3-PIN XLR

2

 

DMX -

XLR Male Socket

 

XLR Female Socket

1 Ground

2 Cold

 

2 Cold

1 Groun

 

3 Hot

 

 

3 Hot

Figure 3

Special Note: Line Termination. W used, you may need to use a terminator o behavior. A terminator is a 110-120 ohm nected between pins 2 and 3 of a male DATA -). This unit is inserted in the fem unit in your daisy chain to terminate the (ADJ part number Z-DMX/T) will decrea behavior.

1

3

2

5-Pin XLR DMX Connectors. Some

512 data cables for DATA transmission fixtures may be implemented in a 3-pin D dard 5-pin data cables in to a 3-pin line a these adaptors are readily available at m below details a proper cable conversion.

3-Pin XLR to 5-Pin XLR Co

Conductor

3-Pin XLR Female (O

Ground/Shield

Pin 1

Data Compliment (- signal)

Pin 2

 

 

Data True (+ signal)

Pin 3

Not Used

 

Not Used

 