specications, diagrams, images, and instructions herein are
subject to change without notice. ADJ Products, LLC logo and
identifying product names and numbers herein are trademarks
of ADJ Products, LLC. Copyright protection claimed includes all
forms and matters of copyrightable materials and information
now allowed by statutory or judicial law or hereinafter granted.
Product names used in this document may be trademarks or
registered trademarks of their respective companies and are
hereby acknowledged. All non-ADJ Products, LLC brands and
product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property, equipment, building, and
electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any
information contained within this document, and/or as a result
of the improper, unsafe, unsucient and negligent assembly,
installation, rigging, and operation of this product.
3/14
User Instructions
Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment.
Please turn o all electrical products when they are not in use. To
avoid power consumption in idle mode, disconnect all electrical
equipment from power when not in use. Thank you!
Dotz Par Introduction
Dotz Par General Instructions
Unpacking: Thank you for purchasing the Dotz Par by ADJ Products,
LLC. Every Dotz Par has been thoroughly tested and has been shipped
in perfect operating condition. Carefully check the shipping carton for
damage that may have occurred during shipping. If the carton appears
to be damaged, carefully inspect your xture for any damage and be
sure all accessories necessary to operate the unit has arrived intact. In
the case damage has been found or parts are missing, please contact
our toll free customer support number for further instructions. Do not
return this unit to your dealer without rst contacting customer sup-
port.
Introduction: The Dotz Par is part of ADJ’s continuing pursuit for cre-
ating high quality affordable intelligent fixtures. The Dotz Par is a high
performance, DMX intelligent, moving head LED fixture. This fixture
is a great piece for retail stores, displays, mood, architectural, interior
and exterior decoration, and clubs. This unit can be used as a stand
alone, or in a Master/Slave conguration. The unit can also be controlled via DMX controller. This fixture is suitable for theaters, studios,
retail stores, and other similar locations.
Customer Support: ADJ Products, LLC provides a toll free cus-
tomer support line, to provide set up help and to answer any question
should you encounter problems during your set up or initial operation.
You may also visit us on the web at www.adj.com for any comments
or suggestions. Service Hours are Monday through Friday 8:00 a.m. to
4:30 p.m. Pacic Standard Time.
Voice: (800) 322-6337
Fax: (323) 582-2941
E-mail: support@americandj.com
To purchase parts online visit http://parts.americandj.com
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations
of this unit. These instructions contain important safety information
regarding the use and maintenance of this unit. Please keep this manual
with the unit, for future reference.
• 4 Operating Modes - Sound Active, Auto Run, Built-In Programs,
or DMX Control
• Power Cord Daisy Chaining (See Page 21)
Dotz Par Warranty Registration
The Dotz Par carries a 2 year (730 days) limited warranty. Please fill
out the enclosed warranty card to validate your purchase and war-
ranty. You may also register your product online at www. americandj.
com. All returned service items whether under warranty or not, must
be freight pre-paid and accompany a return authorization (R.A.) number. If the unit is under warranty you must provide a copy of your
proof of purchase invoice. Please contact ADJ Products, LLC customer support for a R.A. number.
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact
ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - Dotz Par User Manual Page 2
ADJ Products, LLC - www.adj.com - Dotz Par User Manual Page 3
Dotz Par Safety Precautions
Dotz Par Set Up
• To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required volt age for your unit.
• Do not attempt to operate this unit if the power cord has been
frayed or broken. Do not attempt to remove or break o the ground
prong from the electrical cord. This prong is used to reduce the risk
of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user
serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper
ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out`
doors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by
t he manufacturer. See page 19 for cleaning details.
• Heat -The appliance should be situated away from heat sources
such as radiators, heat registers, stoves, or other appliances (inclu d ing amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the appliance.
C. The appliance has been exposed to rain or water.
D. The appliance does not appear to operate normally or exhibits a
marked change in performance.
Power Supply: The ADJ Dotz Par contains a automatic voltage
switch, which will auto sense the voltage when it is plugged into a
power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere. Always use
the PowerCon cord that came with the unit.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures
and controllers. A DMX controller sends DMX data instructions from
the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA
“OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of
dierent manufactures to be linked together and operate from a single
controller, as long as all xtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order
in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. When a fixture is assigned a DMX address
of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The Dotz Par can be controlled via DMX-512 protocol. The Dotz Par has
4 DMX Channel Modes. The DMX address is set on the rear panel of the
Dotz Par. Your unit and your DMX controller require a approved DMX512 110 Ohm Data cable for data input and data output (Figure 1). We
recommend Accu-Cable DMX cables. If you are
making your own cables, be sure to use standard
110-120 Ohm shielded cable (This cable may be
purchased at almost all professional sound and
lighting stores). Your cables should be made with
a male and female XLR connector on either end
of the cable. Also remember that DMX cable must
be daisy chained and cannot be split.
ADJ Products, LLC - www.adj.com - Dotz Par User Manual Page 4
Figure 1
ADJ Products, LLC - www.adj.com - Dotz Par User Manual Page 5
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signalerrors andavoids signal transmission problemsand interference. It is always advisableto connect a DMX terminal, (Resistance120 Ohm 1/4 W) between PIN 2 (DMX-)and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUTOUTPUT
Dotz Par Set Up
Dotz Par System Menu
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
1 Ground
3 Hot
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
When longer runs of cable are
Figure 4
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
XLR Male Socket
1 Ground
DMX512 OUT
3-PIN XLR
2 Cold
3 Hot
1
3
2
DMX +
DMX -
XLR Female Socket
2 Cold
Figure 3
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
5-Pin XLR DMX Connectors.
connectors for DATA transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting standard
5-pin XLR connectors in to a 3-pin line a cable adaptor must be used,
these adaptors are readily available at most electric stores. The chart
below details a proper cable conversion.
Conductor5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
Some manufactures use 5-pin XLR
3-Pin XLR to 5-Pin XLR Conversion
Pin 1
Pin 2
Pin 3
The LCD backlight will shut o after 30 seconds, to relight
the background, press the MODE button for 5 seconds.
DMX Mode - Set the DMX Address and DMX Channel
Mode -
1. Press the MODE button until “AXXX” is displayed. “XXX” represents the current displayed address.
2. Use the UP or DOWN buttons to change the DMX address.
3. After setting your DMX address press ENTER. You can now
select your desired DMX channel mode. Use the UP or DOWN
buttons to nd your desired DMX channel mode, press ENTER
when you nd your desired DMX channel mode.
4. After you press ENTER you can now set your dimmer curve.
There are 5 dimmer curve settings. See Dimmer Curve below for
the dierent curves. Select you desired dimmer curve setting,
and press ENTER.
5. After you press ENTER you can set your NO DMX setting. This
setting is a precaution setting. This setting is in case you DMX
signal is lost or interrupted. See NO DMX on page 9 for the dierent settings. Press ENTER when you are nished to return to the
DMX address setting.
Dimmer Curve - This setting will let you select your
desired dimmer curve.
1. Press the MODE button until “dcXX” is displayed, press ENTER.
2. 1 of 5 dimming curve settings will be displayed: Standard,
Stage, TV, Architectural, or Theatre. Use the UP and DOWM buttons to select your desired dimming curve and press ENTER to
conrm.
NO DMX - This mode can be used as a precaution mode,
ADJ Products, LLC - www.adj.com - Dotz Par User Manual Page 6
ADJ Products, LLC - www.adj.com - Dotz Par User Manual Page 7
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.