Ademco TH8732WF01 User Manual

Lyric™ Thermostat
33-00031EFS-01
SUBMITTAL SHEET
APPLICATION
The Lyric Thermostat is a Wi-Fi enabled comfort system designed to be easy to use as well as maximizes home comfort. Lyric provides control of single stage and multi stage conventional and heat pump heating and cooling systems. The thermostat controls up to 2 heat / 2 cool conventional systems and up to 3 heat / 2 cool heat pump systems. The
thermostat also controls humidication, dehumidication or ventilation
through the Lyric App.
Automatically maintains comfort by considering temperature,
humidity and weather
• Control from anywhere by smartphone or tablet
• No complex menus. One-touch buttons save you time
Smart alerts remind you of lter changes and warn you of extreme
indoor conditions
• Weather information to help plan your day
SPECIFICATIONS
Includes:
Lyric Wi-Fi thermostat
Lyric App for Android or iOS
AAA Lithium battery, wall plate, wall cover and mounting screws
Requirements:
802.11 b/g/n home wireless router
Android or iOS smartphone, tablet or device
Models:
TH8732WF5018
TH8732WF5034
Terminal Designations:
U1B, U1A, C, L, G, K, Y, Y2, W (O/B), W2 (Aux/E), R, Rc
Electrical Ratings:
Terminal Voltage
W - O/B (heating) W2 - Aux/E (heating)
Y (cooling) 18 to 30 VAC 1.00A Y2 (cooling) 18 to 30 VAC 0.60A K 18 to 30 VAC 1.00A G (fan) 18 to 30 VAC 0.50A L (output) 18 to 30 VAC 1.00A
U1B, U1A
Power Consumption:
Full brightness = 3.0 VA
Wi-Fi Communication: 2.4GHz range Temperature Setting Range:
Heating: 40 to 90 °F (4.5 to 32 °C) Cooling: 50 to 99 °F (10 to 37 °C)
Temperature Sensor Accuracy:
± 1.5 °F at 70 °F (0.75 °C at 21.0 °C)
Humidication Setting Range: 10% to 60% RH Dehumidication Setting Range: 40% to 80% RH
Humidity Display Range: 0% to 99% Humidity Sensor Accuracy:
± 5% RH from 30% to 50% RH at 75 °F (24 °C)
Cool Indication: Displays the snowake icon in cooling mode. Heat Indication: Displays the sun icon in heating mode. Mounting Means:
Thermostat: The thermostat is mounted via a wall plate. The wall
plate is mounted directly on the wall in the living space, using
mounting screws provided. The thermostat is then snapped directly onto the wall plate.
Trim Ring (Optional): The wall plate is rst attached to the trim
ring. The trim ring and wall plate are then mounted directly
on the wall in the living space, using mounting screws and
anchors provided.
(50/60 Hz)
18 to 30 VAC 1.00A
18 to 30 VAC 0.60A
18 to 30 VAC 0.10 A
Max. Current Rating
Job Name
Engineer
Mechanical Contractor
Contractor’s P.O. No.
Representative
Model(s) Qty.
TH8732WF5018 TH8732WF5034
Approval
Service
Tag No.
Product Part Number Operating Ambient
TH8732WF5018
Thermostat
TH8732WF5034
Temperature
32 to 120 °F
(0 to 48.9 °C)
32 to 120 °F
(0 to 48.9 °C)
Operating
Relative
Humidity
5% to 90% Non-Condensing
5% to 95% Non-Condensing
Shipping
Temperature
-20 to 120 °F
(-28.9 to 48.9 °C)
-20 to 120 °F
(-28.9 to 48.9 °C)
Physical Dimensions in mm
(Height x Width x Depth)
96.5 x 96.5 x 22.49 White
96.5 x 96.5 x 22.49 White
Color(s)
REGULATOR INFORMATION
FCC Compliance Statement (Part 15.19) (USA only)
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
FCC Warning (Part 15.21) (USA only)
Changes or modications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC Interference Statement (Part 15.105 (b)) (USA only)
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures:
Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Thermostats
To comply with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure, the antenna(s) used
for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Section 7.1.2 of RSS-GEN
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and
its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that necessary for
successful communication.
Section 7.1.3 of RSS-GEN
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including
interference that may cause undesired operation of the device.
Automation and Control Solutions
Honeywell International Inc. 1985 Douglas Drive North
Golden Valley, MN 55422
customer.honeywell.com
® U.S. Registered Trademark
© 2014 Honeywell International Inc.
33-00031EFS—01 M.S. 04-14
Printed in United States