ADE ULTIMATE ID User Manual

Specifications and Main Features

  • iD Sensing: integrierte iD-Sensing-Linie für bis zu 30 parallel angeschlossene iD-Punkte.
  • iD Line Erweiterung: Steckerblock Ergänzung schlägt ein weiteres IД Modem vor, um eine weitere 30 IД-Punkte zu erreichen.
  • Wyring Scheme Choice: Each parallel wiring scheme such as star, T and ring can be opted for any application.
  • Cable Type: 2 cores used to sense only, 4 cores were used to sense and also apply a voltage (PIRs).
  • Maximum Allowed Length of Cable: single parallel cable run of up to 30 devices may extend to 100m with a requirement to reduce (7 strands 0.2mm²) cables.
  • Response Time for iD Device: Lastly, devices available by default are 300ms, while each point can be programmed to 800ms.
  • Bell/Strobe Output: Programmable configurations, and also with rearmable options 12V -Ve switch.
  • Bell/Strobe Current: Combined output maximum surge can reach up to 1Amp.
  • Inside Sounders: A maximum of 3 high definitional twenty one ohms speakers with audio signals are 180mA each.
  • Digital Outputs (P1 — P6): Say variable switch to 12V sinks or sources ten milliamps which are selectable over different types.
  • Digital Inputs (P7 — P8): Grounding on the input triggers these; four conditions over normally + or – are selectable on these inputs.
  • Cpu Current: With an average intake of 290 mA (while having 60 points) is quite typical for these items.
  • Low Voltage Output: A steady state of 13 V dc is obtained.
  • Battery Charge Voltage: A battery charge voltage of 13.8 V dc is also obtained and is kept steady.
  • Type of Battery: The battery capacity has a 6Ah rechargeable capability of 12V volts.
  • Mains Voltage Supply: The combined mains voltage supply, which is of 50Hz, is within the range of 220 volts to 245 volts in ac.
  • Current Output Total: The maximum current output is capped at 1.5 Amps.
  • Fuses: The bell fuse has an amperage rating of 1 Amp, strobe has 1.6A and the both have quick blow 20 mm fuses, the battery is rated at 20MM2 .
  • Number of Programmes: Eight setting programs which have differing set ups or configurations.
  • Groups Shunt: Eight individual groups with room for 59 inclusive of a facility of overlap on the demand.
  • Codes for Users: There are sixteen codes for the users and the codes range between 1 upto 8 digits, user levels are set to 6 with an additional for duress.
  • Events Logging: The date is also used as a reference in logging 999 events.
  • NVM: Retains all programmed information including the entire event log.
  • No of version timely/Software Version No:: ‘Timely P’: version 1.2

Frequently Asked Questions

Q1: What is the maximum number of iD points that can be connected to the identicator?

A1: A total of up to 30 common id point types can be connected in parallel to the iD sensing integral line, in addition to that another 30 can also be added with plug in line expansion .

Q2: Is there a limitation on the length of cables that can be used for the connections of iD devices?

A2: For each stand alone parallel single cable maximally 30 device runs the maximum length is upto 100 metres .

Q3: Is there a connection for bells and strobe outputs?

A3: The 12 volts system has a negative switch bell strobe circuit which a maximum of a combined 1 amp output.

Q4 Can I alter the iD devices’ time attribute? A4 I can alter the point attribute to 300ms or set it to extended 800ms time per point.

Q5 Up until how many users and their respective codes are able to be programmed into the system? A5 A maximum of 16 user codes are accepted by the device, user codes are an aggregate of 1-8 digits which have 6 levels of authority alongside a duress code.

Q6 What is the type of battery that the device claims to support? A6 This device operates and supports a 12Volts rechargeable battery which has the ability to hold 6Ah of charge.

Q7 What will take place when the system enters an alarm condition? A7 When the alarm condition has been activated, the internal sounders, external bells as well as the digicom output will produce sound as per the configured point type.

Q8 Are there additional features or functionalities to cater missed alarms? A8 Several functionalities have been embedded into the device to resolve false alarms activations including soak tests, long response times, attributes of double knock and entry deviation among others.