Safe ty in struc tions for lithium batteries (CR2032/CR2430):
warran ty for t he Body Ana lysing S
This symbol on the product or on its packaging indicates th
product shall not be treated as household waste. Instead it shall be
handed over to the applicable collection point for the recycling of
electrical and electronic equipment. For more detailed information
1. Lithium batteries are lithium manganese cells. If you do not use the scale over a longer
period, you should take out the batteries of the device.
2. Never open the lithium battery, do not put into fire, or expose to shocks because an
explosion risk lasts or discharge of poisonous exposure to fumes might possible.
3. Never touch leaked cells with bare hands.
4. When eyes or hands are contaminated, it is essential to rinse with lots of water. You
should go to a doctor if skin or eyes are irritated.
5. Dispose cells only completely discharged or protected against polarity reversal
wrapped according to your local disposal regulation.
6. Do not expose the cells to direct solar radiation and store away from heat;
otherwise, there is risk of overheating.
7. Maintain a storage temperature of < 40°C.
Disposal of old electrical and electronic equipmen t
about recycling contact your local city offi
&---------------------------------------------------------------------------------------------------------
• Sen der • Reason for complaint
Vielen Dank, dass Sie sich für den Kauf dieser Körperanalysewaage entschieden haben.
Bitte lesen Sie diese Betriebsanleitung vor der ersten Inbetriebnahme sorgfältig durch
________________________________ _____________________________________________
und bewahren sie dann gut auf, damit Ihnen diese Informationen bei Bedarf immer
wieder zur Verfügung ste
________________________________ _____________________________________________
________________________________ _____________________________________________
_____________________________________________
• Date of purchase
Please return this guarantee card together with the receipt to your retailer.
disposal service or the shop where you purchased the product.
ADE (GmbH & Co.)
1.
Model Barbara / BA 914
Instruction Manual
Directory
1. How does the body analyser work?.......................Page 2
2. Conditions to use.............................................................Page 2
3. Commissioning..................................................................Page 3
4. Programming / enter of personal data...........................Pag e 4
5. Weighing function (weight measurement only)............Page 4
6. Body Analysis.....................................................................Page 5
7. Error Messages.................................................................Page 6
8. Technical Data...................................................................Page 7
9. Warranty...............................................................................Page 7
Operati ng M anual_N_BA914_XY6062_EN_100324_REV001
Thank you for your decision to purchase this high-quality body analyser scale. Please
peruse read this instruction manual prior to first start up and keep this user instruction
careful to have this information on hand whenever it is needed.
1. How does the body analyser work?
Through this new revolutionary scale, you will be able to get information about your body
composition with reference to your weight, body fat %, body water %, muscle mass %
and bone mass kg. First of all, you have to enter once your personal data like gender
(male or female), age and body height under your selected personal memory location.
Afterwards a measurement is as simple as on a normal bathroom scale. Afterwards a
measurement is as simple as on a normal bathroom scale. You have only to select your
personal memory location, step on the scale and within a few seconds, your measured
values will be indicated. The analysis based on the measurement of the body’s electrical
resistance. A low, safe electrical signal passes freely through fluids contained in lean
tissue, such as muscle and blood, but meets resistance passing through fat tissue. The
body analyser accurately measures the resistance and with reference to your personal
data use it to calculate elements of body composition.
2. Conditions to use
If possible, the measurement should be done undressed and always barefoot.
By nature, a body is subject of fluctuations (for example loss of water after taking
exercise or after a sauna visit, after a meal, etc.). To enable comparable readings it is
important to take the measurements as possible always under the same conditions.
In order to ensure that the results of analysis are accurate and consistent, please keep
the measurement conditions constant always at the same daytime. In the morning,
directly after you’ve woken up, your body will be dehydrated and also the majority of fluid
will be stored in the central trunk area. This means that the resistance is relatively high
because of the poor conductivity in the body. By intensify moving during the day
progresses the fluid becomes more evenly distributed through the limbs and increasing
the accuracy of the readings. To get a realistic result it is important to take your readings
at the same time and under the same conditions every day. The easiest way to stick the
rule, measure always in the morning, 15 minutes after you’ve got up, either before or
after you’ve gone to the bathroom.
In spite of a very low electrica l signal, this bod y ana lyzer is not suitable for persons
with hea rt pacemaker or other elec tronic medical implants! There is no risk for
persons with none electronic implant for instance a titanium plate in the knee. However,
metal conducts the electric current extremely well and therefore the scale implicates the
body fat value “beautified” – means the actual body fat value is higher as indicated.
However, tendencies may be determined as well.
8. Technical Data
Capacity x graduation: max. 150 kg x 100 g
Display resolution: body fat: 0.1%
Display resolution: body water: 0.1%
Display resolution: muscle mass: 0.1%
Display resolution: bone mass: 100 g
Personal memory loc.: 10 positions
Age: 10 – 80 years
Body height: 100 – 240 cm
Dimensions: approx. 300 mm x 300 mm x 34 mm
Batteries: 2 x CR2032 (included)
Subject to technical modifications
9. Warranty
ADE warrants for a period of 3 years from the date of purchase that it will remedy any
defects due to faulty material or workmanship free of charge by repair or replacement.
When purchasing, please have the warranty coupon signed and stamped by the dealer.
When making a guarantee claim, please return the weighing scale together with the
guarantee card including the reason of complaint to your dealer.
CE-Conformity - This device fea tures radio interference
suppress ion in complian ce with valid EC Regulation 2004/108
Note: The displayed value may be adversely affected under extreme electromagnetic
influences, e.g. when using a radio unit in the immediate vicinity of the device. Once the
interference has been rectified, the product can once again be used for its intended
purpose. The device may have to be switched-on again.
Statutory instruc tions on battery disposal
Batteries must not be disposed as household waste. The law requires that you, as
consumer, return the waste batteries either to public collection points in your town or
village or to any outlet selling batteries of the same kind.
Note:
Batteries are marked as follows:
CR (Li); AA (Al, Mn); AAA (Al, Mn)
Li = Battery contains Lithium
Al = Battery contains Alkali
Mn = Battery contains Manganese