Addonics Technologies RT5835HMEU User Manual

ADDONICS TECHNOLOGIES
LED pins
Pin 1
SATA Port 2
SATA Port 4
SATA Port 1
SATA Port 3
Photo identifying SATA port s on HPM
Power LED
Power Switch
USB port
eSATA port
RAID config rotary switch
RAID setting button
Power Connector
Power Switch
Use a ballpoint pen tip to press the RAID Setting Button
(LED 1) HPM Health
(LED 3) USB Status
(LED 2) eSATA Status
(LED 1) HPM Health
(LED 3) USB Status
(LED 2) eSATA Status
HPM 1 (Top disk array)
HPM 2 (Bottom disk array)
Set A (4-drive HPM)
Set B (4-drive HPM)
Set B (4-drive HPM)
Set A (4-drive HPM)
Model: RT5835HMEU
I. Installing drive into the RAID Tower V
Step 1
Use a Philips screwdriver to secure the 3.5”
Step 2
Slide the tray into the Disk Array drive bay.
Note: It is recommended to fill up the RAID Tower V with SATA drives from right to left and top to bottom. This is to help in identifying which drives connect to which ports for easier
troubleshooting.
II. Connecting the power cable and RAID Tower V to the
computer
a. Connect the power cord provided from the wall outlet to the back of
the RAID Tower.
b. Make sure the power is off (power LED light should be off).
c. Connect either the provided USB or eSATA cable from the back of
the RAID Tower to the computer. We recommend connecting the eSATA port for best performance if this port is available on your computer.
III. Power on/off control
Turn on the power to the RAID Tower Mini by pressing the power button on the front. The power LED light should lit indicating the power is on.
IV. Setting RAID on the HPM
1. Attach the SATA hard drives (up to 4) to the SATA ports on the Hardware Port Multiplier (HPM) using SATA cables. It is recommended to connect drives to the SATA ports 1 to 4 successively.
2. Set the Rotary switch to the RAID mode required.
3. Push the RAID setting button with a ballpoint pen tip while the HPM is turned off.
4. While holding the RAID setting button, turn on the HPM and SATA hard drives and continue to hold button for at least 5 seconds.
Note: The onboard LED's for the eSATA and USB will start blinking
while holding down the raid setting button. Once the raid setting button is released, the PM Health LED will blink 4-6 times.
If the PM Health LED stops blinking, the raid set is set
correctly. If the PM Health LED lights up as solid green, it is a bad setup. You need to repeat setting up the raid again.
Instruction for Special RAID Modes:
RAID Mode
LEDs
BIG 2
LEDs 1, 2 & 3 all OFF
BIG 4
3 ON, 2 & 1 OFF
FAST 2
2 ON, 3 & 1 OFF
FAST 4
1 ON, 3 & 2 OFF
SAFE FAST
3 & 2 ON, 1 OFF
SAFE 2
3 & 1 ON, 2 OFF
RAID 5
2 & 1 ON, 3 OFF
RAID 5 + S
3, 2 & 1 all ON
BIG 2 - 2 Drives Spanned o Note: Do not connect more than 2 SATA drives to the hardware port
multiplier. Doing so will hang the system when you configure the raid.
o For SATA drives with different capacities, the hardware port
multiplier will use the smallest drive capacity of the 2 drives connected to create the total partition size.
FAST 2 - 2 Drives Striped o Note: Do not connect more than 2 SATA drives to the hardware port
multiplier. Doing so will hang the system when you configure the raid.
Verify RAID Setting on the HPM Note: Disconnect the HPM from host when verifying the RAID setting.
It is assumed that you have already connected the SATA drives and set up the raid mode when verifying the raid setting.
1. Turn on the power for RAID tower mini.
2. Push the RAID setting button with the tool provided. Using the table below, verify if the LEDs are lighting up. The selected LEDs will light up for 2 seconds followed by a blink and cycles back.
LED reference:
LED 1 - HPM Health LED 2 - eSATA Status LED 3 - USB Status
ADDONICS TECHNOLOGIES
Model: RT5835HMEU
TECHNICAL SUPPORT
Phone: 408-453-6212 Hours: 8:30 am - 6:00 pm PST Email: http://www.addonics.com/support/query/
Loading...