Additel ADT 780 Specifications

Additel 780 Series Pressure Controller
New Precision Accuracy Models with
1-Year Uncertainty to 0.01% of Reading
Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy models to 0.01% of reading Standalone solution to 1,000 psi (70 bar), no gas bottle required
when used with the Electric Pump Standard model accuracy of 0.02% of full scale External pressure modules to 3,000 psi (200 bar) WiFi enabled communications Fully temperature compensated accuracy over 0°C to 50°C HART Communication and Profibus PA
Large 7” color touch screen display
Control stability of 0.003%FS Built-in barometer Easy-to-use icon based user interface
01
OVERVIEW
For years, we’ve provided the most durable, accurate, quality pressure calibration products for field applications. The Additel 780 series controller incorporates the same durability, accuracy, and quality into a new bench top controller packed with features and functionality that is remarkably easy to use. The Additel 780 series offers two base ranges: to 1,000 psi (70 bar) and to 3,000 psi (200 bar). The base range establishes the
maximum controlling range of the controller. Each conguration includes a control sensor
which is preselected to the sensor range best suited for your application. External and internal sensors can be used which allows for expanded range and accuracy capability in the future.
There are also two controller types that can be selected: the Additel 780S is the standard controller option without any measurement capability. The Additel 780 has expanded
functionality including electrical measurement and HART and Probus PA communication.
Phone: 714-998-6899 Fax: 714-998-6999 Email: sales@additel.com
Corporate Headquarters
2900 Saturn St #B Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101 Pleasant Grove, UT 84062, USA
MODULAR DESIGN
Each unit comes with one Intelligent Pressure Module configured to the many range offerings provided. Standard accuracy sensors (ADT160A-CPXXX) are silicone pressure sensors with a 1 year accuracy of 0.02% FS. The precision accuracy models improve the 1 year accuracy specification to 0.01% of reading from 100% to 30% of range. Each sensor has been specially aged, tested and screened before assembly. After assembly each sensor
STANDALONE SOLUTION
Typical pressure controllers will require a nitrogen bottle for the gas supply which make it
difcult to move the controller around without having to move or connect to another bottle.
The Additel 780 series is unique in that with the optional electric pump, you can generate pressures to 1,000 psi (70 bar) without the need of a gas bottle.
PROCESS FUNCTIONALITY (excl ADT780S versions)
The 780 Series Pressure Controller is considered to handle a very wide range of applications which may normally require a pressure calibrator. Built-in capability, includes current and voltage measurement capability, 24 volt loop power, HART switch measurement capability, and much more.
is temperature compensated over the range of 0°C to 50°C. The Additel 780 series allows for one internal pressure sensor and one external pressure sensor. The modular design of this unit provides for interchangeability of both the internal and external sensors with other Intelligent Pressure Modules.
In addition to the Intelligent Pressure Modules, the Additel 780 series has a built in barometric sensor. This allows for switching between gauge pressures to absolute pressures.
®
and Probus PA communication,
MEASUREMENT SPECIFICATIONS
Specification ADT780-1K ADT780-3K
Pressure range
Control stability
Precision
(includes 1 year stability)
Media
Over-range indication
Resolution
Pressure type
Warm up time
Measurement units
Minimum control pressure
[1] HP gas supply required to reach 3,000 psi (200 bar). [2] 7 digit resolution for precision model only. [3] Dependent on pressure module.
-14.5 to 1,000 psi (-0.95 to 70 bar) -14.5 to 3,000 psi (-0.95 to 200 bar)
0.003% FS (stability based on % FS of control sensor range)
See pressure range table
Clean gas
103% to 120% (based on sensor)
4, 5, 6, or 7 digits (user selectable)
Gauge, Absolute
15 minutes
Pa, hPa, kPa, MPa, bar, mbar, psi, mmHg@0°C,cmHg@0°C, mHg@0°C, inHg@0°C, inH2O@4°C, mmH2O@4°C, cmH2O@4°C, mH2O@4°C, mmH2O@20°C, cmH2O@20°C, mH2O@20°C, kg/m2, kg/cm2, mtorr, torr, atm, lb/ft2, tsi, user selectable
[3]
0.0001 psi 0.001 psi
[2]
[1]
02
Phone: 714-998-6899 Fax: 714-998-6999 Email: sales@additel.com
Corporate Headquarters
2900 Saturn St #B Brea, CA 92821, USA
Salt Lake City Office
1364 West State Rd. Suite 101 Pleasant Grove, UT 84062, USA
Loading...
+ 4 hidden pages