Adcraft PW-120 Installation Manual

4.5 (2)

PW-120

Heater Proofer

This manual contains important information regarding your Admiral Craft unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply with regular maintenance guidelines outlined in this manual may void the warranty. MUST READ!!!

The Heater-Proofer is an aluminum transport cabinet with heaters that function as a hot food holding cabinet and/or as a proofing cabinet for commercial kitchens. The heat drawer slides into place on the lower ledges of the heating cabinet. A power cord is provided and attached to the heat drawer through an access hole in the back of the cabinet.

The thermostat control knobs are mounted to the left and right of the HEAT/PROOF switch. The left thermostat knob controls the heat in the cabinet from 1 to 9. The right thermostat knob controls the humidity from 1 to 9. Please see below for humidity and thermostat ranges for this unit.

When the power switch is in the ON position, the circulating fan and element will run continuously until switched off.

WARNINGS

Cabinet will hold food hot at a constant temperature

Will supply humidity for proofing when the application applies

This cabinet is not a cooking appliance

UNPACKING

1.Examine the interior and exterior to determine if any damage has occurred during delivery

2.Examine the interior of the unit to make sure all packing materials are removed before the unit is plugged into an electrical outlet

INSTALLATION

1.Position unit on a stable, level surface

2.Plug the cord into any grounded 120-volt AC, 15 amps power supply dedicated breaker

3.It is highly recommended the only power supply cord provided be used

4.Do not operate with an extension cord

MAINTENANCE – NOTE: The equipment has been designed to require minimum maintenance and has been constructed to meet National Sanitation Foundation and U.S. Public Health Service standards

1.Disconnect the cord from the outlet.

2.To avoid damage, do not use abrasive cleaners or scouring pads.

3.Non-toxic chemical cleaners or mild detergents are recommended for cleaning fixtures

4.Hosing or steam cleaning should not be necessary to keep fixtures clean and sanitary

5.Do not allow water or steam to come in contact with electrical components

6.Never power wash or steam clean the cabinet with the power drawer inserted

OPERATING INSTRUCTIONS – NOTE: The internal circulation blower and 1000w heater element (controlled with the Heat Thermostat) will operate continuously when the power switch is turned on.

1.Push main power switch (ON/OFF rocker) to ON position

2.Push HEAT/PROOF switch to HEAT for heating ONLY

3.Turn HEAT thermostat knob fully clockwise for preheat

4.Allow 45 minutes for pre-heating, then turn thermostat to desired setting

5.Place water in the water pan filling to about ¾ full, for proofing

6.For proofing, push HEAT/PROOF switch to PROOF

7.Adjust the heat and humidity thermostat knob to control desired temperature and humidity. Allow 45 minutes for pre-heating

HEAT THERMOSTAT

The controlling range is 80°F to 185°F

The dial numbers 1 thru 9, do not relate to a specific calibrated temperature

Temperature settings must be obtained through familiarization with the unit

The dial also has an OFF position to turn heater unit off

HUMIDITY THERMOSTAT

To control humidity range from 30% to 100%, humidity settings must be obtained through familiarization with the unit

The dial numbers 1 thru 9 do not relate to a specific calibrated humidity

The dial also has an OFF position to turn humidity off

To maintain low heat range between 85°F and 100°F, switch to proof mode and adjust heat knob to desired heat range

Allow 45 minutes to pre-heat in proof cycle

SPECIFICATIONS

 

Model

 

 

Description

Wattage

Voltage

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

PW-120

Heater Proofer Cabinet

1800W

120V/60Hz

15

DIMENSIONS AND WEIGHTS

 

 

 

 

 

 

 

 

 

 

 

 

Net Weight

 

Gross Weight

Overall Dimensions

Cabinet Dimensions

 

 

 

 

 

 

 

 

 

 

112 lbs (51kgs)

 

148 lbs (67kgs)

21”W x 31.25”L x 67.25”H

18”W x 26.25”L x 52.75”H

Thank you for purchasing this Adcraft equipment

Admiral Craft Equipment Corp • 940 S. Oyster Bay Rd. • Hicksville, NY • 11801

Phone: 800-223-7751 • Fax: 800-447-7751

www.admiralcraft.com

PW-120

SWITCH

Z

 

 

 

 

 

 

 

 

 

HEAT

 

W

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

TEMPERATURE

 

 

LIMIT

 

G

 

 

THERMOREGULATOR

 

DISPLAY

 

 

 

 

GROUND

T

M

1000W

800W

600W

 

 

 

 

 

9V

BLOWER

 

MODE

 

 

 

 

SLECTOR

 

 

TRANSFORMER

 

 

 

 

 

 

SWITCH

 

POWER

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

HEAT

 

HUMIDITY THERMOSTAT

PROOF

VER811

Adcraft PW-120 Installation  Manual

Heater Proofer Cabinet Assembly Instructions

PW-120 Heater Proofer Cabinet Parts Layout

 

 

 

Please read the assembly instructions before putting together

Parts Listing and Drawing Numbers

%RWWRP %RDUG

/HIW VLGH FDELQHW

5LJKW VLGH FDELQHW

 

%RDUG

%RDUG

4XDQWLW\ SLHFH

4XDQWLW\ SLHFH

4XDQWLW\ SLHFH

 

 

 

+HDG &RYHU

%DFN 3DQHO

'RRUIUDPH %UDFLQJ 3LHFH

4XDQWLW\ SLHFH

4XDQWLW\ SLHFH

4XDQWLW\ SFV

 

 

 

8QLYHUVDO :KHHO

6KXWWHU RI WKH

+HDWHU

 

&DELQHW %RG\

 

4XDQWLW\ SFV

4XDQWLW\ SFV

4XDQWLW\ SLHFH

:LQG 'HIOHFWRU

7UDQVSDUHQW 'RRU

,QVWDOODWLRQ $X[LOLDU\

 

 

3DUWV

 

 

XVHG ZKHQ QHHGHG LQ

 

 

LQVWDOODWLRQ

4XDQWLW\ SLHFH

4XDQWLW\ SLHFH

4XDQWLW\ SFV

Loading...
+ 11 hidden pages