Heater Proofer
This manual contains important information regarding your Admiral Craft unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply with regular maintenance guidelines outlined in this manual may void the warranty. MUST READ!!!
The Heater-Proofer is an aluminum transport cabinet with heaters that function as a hot food holding cabinet and/or as a proofing cabinet for commercial kitchens. The heat drawer slides into place on the lower ledges of the heating cabinet. A power cord is provided and attached to the heat drawer through an access hole in the back of the cabinet.
The thermostat control knobs are mounted to the left and right of the HEAT/PROOF switch. The left thermostat knob controls the heat in the cabinet from 1 to 9. The right thermostat knob controls the humidity from 1 to 9. Please see below for humidity and thermostat ranges for this unit.
When the power switch is in the ON position, the circulating fan and element will run continuously until switched off.
WARNINGS
•Cabinet will hold food hot at a constant temperature
•Will supply humidity for proofing when the application applies
•This cabinet is not a cooking appliance
UNPACKING
1.Examine the interior and exterior to determine if any damage has occurred during delivery
2.Examine the interior of the unit to make sure all packing materials are removed before the unit is plugged into an electrical outlet
INSTALLATION
1.Position unit on a stable, level surface
2.Plug the cord into any grounded 120-volt AC, 15 amps power supply dedicated breaker
3.It is highly recommended the only power supply cord provided be used
4.Do not operate with an extension cord
MAINTENANCE – NOTE: The equipment has been designed to require minimum maintenance and has been constructed to meet National Sanitation Foundation and U.S. Public Health Service standards
1.Disconnect the cord from the outlet.
2.To avoid damage, do not use abrasive cleaners or scouring pads.
3.Non-toxic chemical cleaners or mild detergents are recommended for cleaning fixtures
4.Hosing or steam cleaning should not be necessary to keep fixtures clean and sanitary
5.Do not allow water or steam to come in contact with electrical components
6.Never power wash or steam clean the cabinet with the power drawer inserted
OPERATING INSTRUCTIONS – NOTE: The internal circulation blower and 1000w heater element (controlled with the Heat Thermostat) will operate continuously when the power switch is turned on.
1.Push main power switch (ON/OFF rocker) to ON position
2.Push HEAT/PROOF switch to HEAT for heating ONLY
3.Turn HEAT thermostat knob fully clockwise for preheat
4.Allow 45 minutes for pre-heating, then turn thermostat to desired setting
5.Place water in the water pan filling to about ¾ full, for proofing
6.For proofing, push HEAT/PROOF switch to PROOF
7.Adjust the heat and humidity thermostat knob to control desired temperature and humidity. Allow 45 minutes for pre-heating
HEAT THERMOSTAT
•The controlling range is 80°F to 185°F
•The dial numbers 1 thru 9, do not relate to a specific calibrated temperature
•Temperature settings must be obtained through familiarization with the unit
•The dial also has an OFF position to turn heater unit off
HUMIDITY THERMOSTAT
•To control humidity range from 30% to 100%, humidity settings must be obtained through familiarization with the unit
•The dial numbers 1 thru 9 do not relate to a specific calibrated humidity
•The dial also has an OFF position to turn humidity off
•To maintain low heat range between 85°F and 100°F, switch to proof mode and adjust heat knob to desired heat range
•Allow 45 minutes to pre-heat in proof cycle
SPECIFICATIONS
|
Model |
|
|
Description |
Wattage |
Voltage |
Amps |
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
PW-120 |
Heater Proofer Cabinet |
1800W |
120V/60Hz |
15 |
|||
DIMENSIONS AND WEIGHTS |
|
|
|
|
|
|||
|
|
|
|
|
|
|||
|
Net Weight |
|
Gross Weight |
Overall Dimensions |
Cabinet Dimensions |
|||
|
|
|
|
|
|
|
|
|
|
112 lbs (51kgs) |
|
148 lbs (67kgs) |
21”W x 31.25”L x 67.25”H |
18”W x 26.25”L x 52.75”H |
Thank you for purchasing this Adcraft equipment
Admiral Craft Equipment Corp • 940 S. Oyster Bay Rd. • Hicksville, NY • 11801
Phone: 800-223-7751 • Fax: 800-447-7751
www.admiralcraft.com
PW-120
SWITCH
Z |
|
|
|
|
|
|
|
|
|
HEAT |
|
W |
|
|
|
THERMOSTAT |
|
|
|
|
|
|
|
|
TEMPERATURE |
|
|
LIMIT |
|
G |
|
|
THERMOREGULATOR |
|
|
DISPLAY |
|
|
|
|
|
GROUND |
T |
M |
1000W |
800W |
600W |
|
|
|
|
||
|
9V |
BLOWER |
|
MODE |
|
|
|
|
SLECTOR |
|
|
|
TRANSFORMER |
|
|
|
|
|
|
|
SWITCH |
|
|
POWER |
|
|
|
|
|
|
|
|
|
|
|
CABLE |
|
|
|
|
|
|
|
|
|
HEAT |
|
HUMIDITY THERMOSTAT
PROOF
VER811
Heater Proofer Cabinet Assembly Instructions
PW-120 Heater Proofer Cabinet Parts Layout
|
|
|
Please read the assembly instructions before putting together
Parts Listing and Drawing Numbers
%RWWRP %RDUG |
/HIW VLGH FDELQHW |
5LJKW VLGH FDELQHW |
|
%RDUG |
%RDUG |
4XDQWLW\ SLHFH |
4XDQWLW\ SLHFH |
4XDQWLW\ SLHFH |
|
|
|
+HDG &RYHU |
%DFN 3DQHO |
'RRUIUDPH %UDFLQJ 3LHFH |
4XDQWLW\ SLHFH |
4XDQWLW\ SLHFH |
4XDQWLW\ SFV |
|
|
|
8QLYHUVDO :KHHO |
6KXWWHU RI WKH |
+HDWHU |
|
&DELQHW %RG\ |
|
4XDQWLW\ SFV |
4XDQWLW\ SFV |
4XDQWLW\ SLHFH |
:LQG 'HIOHFWRU |
7UDQVSDUHQW 'RRU |
,QVWDOODWLRQ $X[LOLDU\ |
|
|
3DUWV |
|
|
XVHG ZKHQ QHHGHG LQ |
|
|
LQVWDOODWLRQ |
4XDQWLW\ SLHFH |
4XDQWLW\ SLHFH |
4XDQWLW\ SFV |