ADC’s line of armored outdoor loose tube cables with polyethylene jackets are designed to meet
all the rigors of the outside plant environment. The cable core is protected from moisture with
a water swellable tape, eliminating the need for a filling compound. Terminations require less
effort making the installation easier.
Spec Sheet
Features:
Excellent above and below ground reliability
Dry cable core
•
Available in singlemode, 50 µm and
•
62.5 µm multimode versions
Gel-filled buffer tubes
•
All-dielectric or armored construction
•
Available in hybrid constructions
•
(singlemode and multimode)
Excellent crush and impact resistance
•
High pulling force
•
Easy to install
•
UV resistant outer sheath
•
All cables tested to EIA/TIA FOTP standards
•
Rodent-resistant armoring
•
Wide operating temperature range:
•
-40° to 70 °C (-40° to 158 °F)
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
•
Low attenuation for optimum
•
signal reliability
2-288 fibers available
•
Applications:
Campus backbone cabling
•
Outdoor installations: aerial, duct,
•
and direct burial
Harsh climates where rugged cable
•
construction is needed
Compliances:
GR-20-CORE
•
EIA/TIA FOTPs
•
Fiber Optic Cable
Armored Outside Plant Cables
Specifications
Armored Loose Tube Cable
PE Outer Jacket
3.0 mm (0.12 in) Gel-Filled Buffer Tube
Aramid Yarn Strength Member
250 µm UV Colored Optical Fiber
Central Strength Member
Water Swellable Tape and Binder
Plastic Coated Corrugated Steel
Rip Cord (2)
Environmental Characteristics
Armored Outside Plant Cables
Storage Temperature
Operating Temperature
Installation Temperature
Mechanical Characteristics
Max. Tensile Load N (lbf)
Short Term
Long Term
Min. Bend Radius mm (in.)
Installed
Loaded
2700 (607)
800 (180)
134 (5.3)
106 (26.8)
-40˚ to 70 ˚C (-40˚ to 158 ˚F)
-40˚ to 70 ˚C (-40˚ to 158 ˚F)
-30˚ to 70 ˚C (-22˚ to 158 ˚F)
Fibers
2-6062-7274-9698-120122-144146-216218-288
2700 (607)
800 (180)
143 (5.6)
286 (11.2)
2700 (607)
800 (180)
164 (6.4)
328 (12.9)
2700 (607)
800 (180)
184 (7.2)
368 (14.4)
2700 (607)
800 (180)
205 (8.0)
411 (16.1)
2700 (607)
800 (180)
205 (8.0)
411 (16.1)
2700 (607)
800 (180)
235 (9.2)
470 (18.4)
8 / 0 7 • 1 0 5 1 6 6 A E
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Transmission Performance —Guaranteed Minimum Link Lengths
Gigabit Ethernet
Link Length (SX/LX)
Multimode
62.5/125 µm
50/125 µm
50/125 µm Ultra 300
50/125 µm Ultra 550
Singlemode
3
10 Gigabit Ethernet distance guarantees at the long wavelength are achieved via four
3.125 Gbps channels multiplexed with WWDM technology
300 m/550 m35 m/300 m
550 m/550 m86 m/300 m
900 m/550 m300 m/300 m
1040 m/550 m550 m/300 m
NA/5000 m10 km/40 km
10 Gigabit Ethernet
Link Length (SR/LX4)
1
(LR/ER)
3
2
1
8 / 0 7 • 1 0 5 1 6 6 A E
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
3
O r d e r i n g I n f o r m a t i o n
Cable TypeFibersDiameterWeightCatalog Number*
mmin.kg/kmlb/1000'
Armored
(single jacket)
Armored
(dual jacket)
Armored
(single tube)
* Replace XXX with fiber count. i.e 2 fibers = 002
Replace YYY with fiber type:
010 = Singlemode
062 = 62.5/125 µm Multimode
050 = 50/125 µm Multimode
50U = 50/125 µm Ultra Multimode for 300 m 10 Gbps
5U5 = 50/125 µm Ultra Multimode for 550 m 10 Gbps
2-6013.40.53179120QXXXLTDDARYYY
62-7214.30.56199133
74-9616.40.64247166
98-12018.40.72299200
122-12420.50.80353237
146-21620.50.80365245
218-28823.50.92474318
2-72
74-96
2-1210.30.40151101QXXXLTDUARYYY
16.2
18.3
0.64
0.72
351
444
235
298QXXXLTDDARYYY
Spec Sheet
Website: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer