ADC LSZH User Manual

Fiber Optic Cable
Armored Outside Plant Cables
ADC’s line of armored outdoor loose tube cables with polyethylene jackets are designed to meet all the rigors of the outside plant environment. The cable core is protected from moisture with a water swellable tape, eliminating the need for a filling compound. Terminations require less effort making the installation easier.
Spec Sheet
Excellent above and below ground reliability
Dry cable core
Available in singlemode, 50 µm and
62.5 µm multimode versions
Gel-filled buffer tubes
All-dielectric or armored construction
Available in hybrid constructions
• (singlemode and multimode)
Excellent crush and impact resistance
High pulling force
Easy to install
UV resistant outer sheath
All cables tested to EIA/TIA FOTP standards
Rodent-resistant armoring
Wide operating temperature range:
-40° to 70 °C (-40° to 158 °F)
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Low attenuation for optimum
• signal reliability
2-288 fibers available
Applications:
Campus backbone cabling
Outdoor installations: aerial, duct,
• and direct burial
Harsh climates where rugged cable
• construction is needed
Compliances:
GR-20-CORE
EIA/TIA FOTPs
Fiber Optic Cable
Armored Outside Plant Cables
Specifications
Armored Loose Tube Cable
PE Outer Jacket
3.0 mm (0.12 in) Gel-Filled Buffer Tube
Aramid Yarn Strength Member
250 µm UV Colored Optical Fiber
Central Strength Member
Water Swellable Tape and Binder
Plastic Coated Corrugated Steel
Rip Cord (2)
Environmental Characteristics
Armored Outside Plant Cables
Storage Temperature
Operating Temperature
Installation Temperature
Mechanical Characteristics
Max. Tensile Load N (lbf) Short Term Long Term
Min. Bend Radius mm (in.) Installed Loaded
2700 (607)
800 (180)
134 (5.3)
106 (26.8)
-40˚ to 70 ˚C (-40˚ to 158 ˚F)
-40˚ to 70 ˚C (-40˚ to 158 ˚F)
-30˚ to 70 ˚C (-22˚ to 158 ˚F)
Fibers
2-60 62-72 74-96 98-120 122-144 146-216 218-288
2700 (607)
800 (180)
143 (5.6)
286 (11.2)
2700 (607)
800 (180)
164 (6.4)
328 (12.9)
2700 (607)
800 (180)
184 (7.2)
368 (14.4)
2700 (607)
800 (180)
205 (8.0)
411 (16.1)
2700 (607)
800 (180)
205 (8.0)
411 (16.1)
2700 (607)
800 (180)
235 (9.2)
470 (18.4)
8 / 0 7 • 1 0 5 1 6 6 A E
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
2
Fiber Optic Cable
Armored Outside Plant Cables
Optical Performance
Armored Outside Plant Cables
Maximum Attenuation
(dB/km)
850 nm/1300 nm 850 nm/1300 nm 850 nm/1300 nm
Multimode
62.5/125 µm
50/125 µm
50/125 µm Ultra 300
50/125 µm Ultra 550 3.5/1.5 2.7/0.9 47002/500
Singlemode
1
Bandwidth measurements specified overfilled launch conditions (OFL)
2
Bandwidth measurements specified by laser launch
3.5/1.5 2.7/0.8 200/500
3.5/1.5 2.7/0.8 500/500
3.5/1.5 2.7/0.9 2000/500
1310 nm/1550 nm 1310 nm/1550 nm 1310 nm/1550 nm
1.0/1.0 0.4/0.3 N/A
Typical Attenuation
(dB/km)
Bandwidth1
(MHz/km)
Transmission Performance —Guaranteed Minimum Link Lengths
Gigabit Ethernet
Link Length (SX/LX)
Multimode
62.5/125 µm
50/125 µm
50/125 µm Ultra 300
50/125 µm Ultra 550
Singlemode
3
10 Gigabit Ethernet distance guarantees at the long wavelength are achieved via four
3.125 Gbps channels multiplexed with WWDM technology
300 m/550 m 35 m/300 m
550 m/550 m 86 m/300 m
900 m/550 m 300 m/300 m
1040 m/550 m 550 m/300 m
NA/5000 m 10 km/40 km
10 Gigabit Ethernet
Link Length (SR/LX4)
1
(LR/ER)
3
2
1
8 / 0 7 • 1 0 5 1 6 6 A E
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
3
O r d e r i n g I n f o r m a t i o n
Cable Type Fibers Diameter Weight Catalog Number*
mm in. kg/km lb/1000'
Armored (single jacket)
Armored (dual jacket)
Armored (single tube)
* Replace XXX with fiber count. i.e 2 fibers = 002
Replace YYY with fiber type: 010 = Singlemode 062 = 62.5/125 µm Multimode 050 = 50/125 µm Multimode 50U = 50/125 µm Ultra Multimode for 300 m 10 Gbps 5U5 = 50/125 µm Ultra Multimode for 550 m 10 Gbps
2-60 13.4 0.53 179 120 QXXXLTDDARYYY
62-72 14.3 0.56 199 133
74-96 16.4 0.64 247 166
98-120 18.4 0.72 299 200
122-124 20.5 0.80 353 237
146-216 20.5 0.80 365 245
218-288 23.5 0.92 474 318
2-72
74-96
2-12 10.3 0.40 151 101 QXXXLTDUARYYY
16.2
18.3
0.64
0.72
351 444
235 298 QXXXLTDDARYYY
Spec Sheet
Website: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
105166AE 8/07 Revision © 2007 ADC Telecommunications, Inc. All Rights Reserved