ADC HBG76 User Manual

HBG76
Installation/Operator Manual
WARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be
performed by a qualified installer, service agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
—Ne pas entreposer ni utiliser d’essence
ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.
—L’installation et l’entretien doivent être
assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 USA
Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447
e-mail: techsupport@amdry.com
ADC Part No. 113615- 2
Retain This Manual in a Safe Place for Future Refer ence
This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation.
Only qualified technicians should ser vice this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation
manual included with the dryer. The following “FOR YOUR SAFETY” caution must be posted near the dryer in a prominent location.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
We have tried to make this manual as complete as possible and hope you will find it useful. The manufacturer reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models. The illustrations included in this manual may not depict your particular dryer exactly.
POUR VO TRE SÉCURITÉ
Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
IMPORTANT
For your convenience, log the following information:
DA TE OF PURCHASE ________________________________________________ MODEL NO. _____________________
RESELLER’S NAME __________________________________________________________________________________
HBG76
SERIAL NUMBER(S) __________________________________________________________________________________
____________________________________________________________________________________________________
____________________________________________________________________________________________________
Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory , you can F AX your order to ADC at +1 (508) 678-9447 or telephone your order directly to the ADC Parts Department at +1 (508) 678-9000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
“IMPORTANT NOTE TO PURCHASER”
Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer.
2 American Dryer Corp. 113615-2
!
WARNING
Table of Contents ______
Proposition 65
Use of this product could expose you to substances
from fuel combustion that contain chemicals
known to the State of Califor nia to cause cancer,
birth defects and other reproductive harm.
IMPORTANT
You must disconnect and lockout the electric supply and the gas supply or the steam supply before any covers or guards are removed from the machine to allow access for cleaning, adjusting, installation, or testing of any equipment per OSHA standards.
Please observe all safety precautions displayed on the equipment and/or specified in the installation manual included with the dryer.
Before installation, check that the local distribution conditions, nature of gas and pressure, and adjustment of the appliances are compatible.
CAUTION
Dryer(s) should never be left unattended while in operation.
When discarding or storing your old clothes dryer, remove the door.
Lorsque vous entreposez ou mettez votre sécheuse au rebut, enlevez-en la porte.
“Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper operation.”
«Attention: Au moment de l’entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de câblage peuvent entraîner un fonctionnement inadéquat et dangereux.»
Safety Precautions.......................... 4
Specifications ................................. 6
Installation Procedures .................. 8
Location Requirements .................................. 8
Unpacking/Setting Up .................................... 8
Dryer Enclosure Requirements...................... 8
Fresh Air Supply Requirement s .....................9
Exhaust Requirements................................... 9
Electrical Information ................................... 11
Gas Information ........................................... 13
Gas Pressure Testing................................... 15
Steam Information ........................................ 15
Water Information ........................................16
Preparation for Operation/S tart-Up ..............17
Preoperational Test ......................................17
Preoperational Instructions .......................... 17
Shutdown Instructions..................................18
Ser vice/Parts Information ............ 18
Service .........................................................18
Parts............................................................. 18
Warranty Infor mation.................... 18
Returning Warranty Cards ...........................18
Warranty ...................................................... 18
Returning Warranty Parts ............................ 18
WARNING
Routine Maintenance .................... 19
Children should not be allowed to play on or near the dryer(s). Children should be supervised if near dryer(s)
Data Label Information ................. 20
in operation. Under no circumstances should the dryer door
switch(es), lint door/drawer switch(es), or heat safety circuit(s) ever be disabled.
The dryer must never be operated with any of the back guards, outer tops, or service panels removed. Personal injury or fire could result.
The dryer must never be operated without the lint filter/ screen in place, even if an external lint collection system is used.
FOR Y OUR SAFETY
Do not dry mop heads in the dryer. Do not use dryer in the presence of dry cleaning fumes.
The dryers must not be installed or stored in an area where it will be exposed to water and/or weather.
The wiring diagram for the dryer is located behind the control panel.
113615-2 www.amdry.com 3
List of Acronyms __________________
HVAC Heating, Ventilating, and Air-Conditioning in WC Inches of Water Column L.C.D. Liquid Crystal Display L.E.D. Light Emitting Diode L.P. Liquid Propane OSHA Occupational Safety and Health Administration R.M.A. Return Material Authorization UL Underwriters Laboratory
Safety Precautions ___________________
Warning
For your safety, the information in this manual
!
must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury, or loss of life.
The dryer must never be operated with any of the back guards, outer tops, or service panels removed. Personal injury or fire could result.
Failure to properly install, maintain, and/or operate dryer according to this manual and operator’s manuals included with dryer may result in conditions, which can cause serious injury, death and/or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Purchaser and user should consult the local gas supplier for proper instructions to be followed in the event the user smells gas. The instructions should be posted in a prominent location.
A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location.
Do not operate steam dryers with more than 150 psi (10.34 bar) steam pressure. Excessive steam pressure can damage the steam coil and/or harm personnel.
Replace leaking flexible hoses or other steam fixtures immediately. Do not operate the dryer with leaking flexible hoses. Personal injury may result.
Warning
The collection of lint in the burner area and
!
exhaust ductwork can create a potential fire
hazard.
For personal safety, the dryer must be electrically grounded in accordance with local and/or country codes. In the absence of these codes use the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
What To Do If You Smell Gas:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Clear the room, building, or area of all occupants.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified installer, service agency, or gas supplier.
Dryers must be exhausted to the outdoors. Although the manufacturer produces a very versatile dryer,
there are some articles that, due to fabric composition or cleaning method, should not be dried in it.
Warning
Dry only water washed fabrics. Do not dry
!
articles spotted or washed in dry cleaning solvents, combustible detergents, or “all purpose” cleaner. Explosion could result.
Do not dry rags or articles coated or contaminated with gasoline, kerosene, oil, paint, or wax. Explosion could result.
Items that have been spotted or soaked with vegetable or cooking oil constitute a fire hazard and should not be placed in a tumble dryer.
Do not dry mop heads. Contamination by wax or flammable solvents will create a fire hazard.
Do not use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber materials. Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard.
Note: Failure to electrically ground the dryer properly will void the warranty.
Warning
Personal injury or fire could result should the
!
dryer door switch, lint door/drawer, or heat
safety circuit ever be disabled.
Remove articles from the dryer as soon as the drying cycle has been completed.
Warning
Articles left in the dryer after the drying and
!
cooling cycles have been completed can
create a fire hazard.
For safety , proper operation, and optimum performance, the dryer must not be operated with a load less than 66% of its rated capacity.
Warning
You must disconnect and lockout the electric
!
supply and the gas supply or the steam supply before any covers or guards are removed from the machine to allow access for cleaning, adjusting, installation, or testing of any equipment per OSHA standards.
Important: The dryer must be installed in a location/ environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C).
The operation of this appliance may affect the operation of other types of gas appliances, which take their air for safe combustion from the same room. If in doubt, consult the appliance manufacturer(s).
Use this dryer only for its intended purpose, drying fabrics.
4 American Dryer Corp. 113615-2
The “Cool Down” Cycle of tumble dryers should be used to reduce the temperature of the items. They should not be removed from the tumble dryer or piled or stacked while hot.
Fabric softeners or similar products should not be used in a tumble dryer to eliminate the effects of the static electricity, unless this practice is specifically recommended by the manufacturer of the fabric softener or product.
Warning
To reduce the risk of personal injury, install
!
lockable doors to prevent public access to the
rear of the dryers.
Exhaust duct outlet should be checked periodically for blockages, and if any found, removed.
NOTES _____________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
Important: A means of restraint must be used to prevent straining of the gas supply when the appliance is moved.
An external means of power removal (disconnect device) must be provided by the installer.
CE Only
Important: This appliance must only be installed and operated in the country of destination indicated on the dryer’s data plate. If the appliance is to be installed and operated in a country other than the one indicated on the data plate, a data plate amendment must be obtained from American Dryer Corporation.
Warning
This appliance must only operate with the gas
!
type indicated on the dryer’s data plate. If the appliance is converted (gas type is changed), a data plate amendment must be obtained from American Dryer Corporation.
This appliance may cause spillage of products of combustion from an open-flue appliance fitted in the same room, and that such an appliance shall be tested for clearance of products with the appliance in operation and all windows and doors closed.
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
113615-2 www.amdry.com 5
Specifications _____________________________________________________________________
MAXIMUM CAPACITY (DRY WEIGHT) 75 lb
TUMBLER DIAMETER 37” TUMBLER DEPTH 35-1/2” TUMBLER VOLUME 22. 09 cu ft
TUMBLE R / DR IV E M O TO R 3/4 hp BLOWER/FAN MOTOR 3/ 4 hp DOOR OPENING (DIAMETER) 27-3/8” DOOR SILL HEIGHT 27-5/16”
WATER CONNECTION 3/4”-11.5 NH DRYERS PER 20’/40’ CONTAINER 9 / 2 0 DRYERS PE R 48’ /5 3’ TRUC K 25 / 27
VOLTAGE AVAILABLE 120-240V 1ø 2,3w 50/60 Hz APPROXIMATE NET WEIGHT 745 l b APPROXIMATE SHIPPING WEIGHT 775 l b
kcal/hr 15,816 17,381 17,493 17,519
60 Hz 50 Hz
60 Hz 50 Hz
60 Hz 50 Hz
640 cfm 550 cfm
640 cfm 550 cfm
640 cfm 550 cfm
AIRFLOW
HEAT INPUT 130 ,0 00 Bt u/hr
GasElectric
EXHAUST CONNECTION (DIAMETER) 8” COMPRESSED AIR CONNECTION N / A COMPRESSED AIR VOLUME N / A INLET PIPE CONNECTION 1/2” M . N .P.T. VOLTAGE AVAILABLE 200-416V 1,3ø 3,4w 50/60 Hz APPROXIMATE NET WEIGHT 745 l b APPROXIMATE SHIPPING WEIGHT 775 l b AIRFLOW
EXHAUST CONNECTION (DIAMETER) 8” COMPRESSED AIR CONNECTION N / A COMPRESSED AIR VOLUME N / A
OVEN SIZE
kW Btu/hr
18.4 62,763
20.2 68,975
20.3 69,418
20.4 69,5 21 VOLTAGE AVAILABLE 120-240V 1ø 2,3w 50/60 Hz APPROXIMATE NET WEIGHT 745 l b APPROXIMATE SHIPPING WEIGHT 775 l b AIRFLOW
STEAM CONSUMPTION 167 lb/hr OPERATING STEAM PRESSURE 150 psi m ax EXHAUST CONNECTION (DIAMETER) 8” COMPRESSED AIR CONNECTION N / A
Steam
COMPRESSED AIR VOLUME N / A BOILER HORSEPOWER (NORMAL LOAD) 5 Bhp SUPPLY CONNECTION 3/ 4” F.N. P.T. RETURN CONNECTION 3/4” M.N.P.T.
Shaded areas are stated in metric equivalents 6/17/08
34.02 kg
93.98 cm
90.17 cm
625.52 L
0.56 kW
0.56 kW
69.53 cm
69.37 cm
337.93 kg
351.53 kg
18.12 cmm
15.58 cmm
32.75 kcal/hr
20.32 cm
337.93 kg
351.53 kg
18.12 cmm
15.58 cmm
20.32 cm
337.93 kg
351.53 kg
18.12 cmm
15.58 cmm
75.74 kg/hr
10.34 bar
20.32 cm
Note: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
6 American Dryer Corp. 113615-2
Specifications _____________________________________________________________________
113615-2 www.amdry.com 7
Installation Procedures ______________
Installation should be performed by competent professional in accordance with local, state, and country codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1­LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/ CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections).
Location Requirements ______________
Before installing the dryer, be sure the location conforms to local, state, and country codes. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LA TEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/ CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing).
The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Dryers installed in residential garages must be elevated 18-inches (45.72 cm) above the floor.
Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply Requirements section).
Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer Enclosure Requirements section).
Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements section).
The dryer must be installed with a proper exhaust duct connection to the outside as noted in this manual (refer to Exhaust Requirements section).
The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements section).
Important: The dryer should be located where a minimum amount of exhaust ducting will be necessary.
The dryer must be installed with adequate clearance for air openings into the combustion chamber.
Caution
This dryer produces combustible lint and must
!
be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint buildup.
Important: The dryer must be installed in a location/ environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C).
Unpacking/Setting Up ________________
Remove protective shipping material (i.e., plastic wrap and optional shipping box) from the dryer.
Important: Dryer must be transported and handled in an upright position at all times.
The dryer can be moved to its final location while still attached to the skid or with the skid removed. To remove the skid locate and remove the 2 bolts securing the base of the dryer to the wooden skid. One is located at the center rear and the other is at the center front.
With the skid removed, use caution and assure all four leveling legs are fully retracted, if the dryer is to be slid into its final position.
Leveling Dryer
The dryer is equipped with 4 leveling legs, 1 at each corner of the base. For optimum performance the dryer should be level front-to-back and side-to-side.
Dryer Enclosure Requirements _______
Commercial Type II
Bulkheads and partitions should be made of noncombustible material.
Note: Allowances must be made for opening the control door.
A The requirement to allow the door to open completely is
40-inches (101.6 cm).
B A minimum overhead clearance of 6-inches (15.24 cm)
is required.
C Dryer should be positioned a minimum of 12-inches
(30.48 cm) away from the nearest obstruction. 24-inches (60.96 cm) is recommended for ease of installation,
maintenance, and service. D 1/16” (1.5875 mm) minimum is required. E Flooring should be level or below dryer cabinet for ease
of removing panels during maintenance. F Dryers may be positioned sidewall to sidewall, however
a 1/16” (1.5875 mm) minimum allowance must be made
for the opening and closing of the control door, along
with the removal of panels during maintenance.
8 American Dryer Corp. 113615-2
Fresh Air Supply Requirements ______
When the dryer is operating, it draws in room air, heats it, passes this air through the tumbler, and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected. Ignition problems and sail switch “fluttering” problems may result, as well as premature motor failure from overheating. The dryer must be installed with provisions for adequate combustion and make-up air supply.
Air supply (make-up air) must be given careful consideration to ensure proper performance of each dryer. Fresh air ventilation openings shall not be blocked and/or sealed. As a general rule, an unrestricted air entrance from the outdoors of 135 inch 1 inch
It is not necessary to have a separate make-up air opening for each dryer. Common make-up air openings are acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to all the dryers.
To compensate for the use of registers or louvers used over the openings, this area must be increased by approximately 33%. Make-up air openings should not be located in an area directly near where exhaust vents exit the building.
Allowances must be made for remote or constricting passageways or where dryers are located at high altitudes or predominantly low pressure areas.
Note: Component failure due to dry cleaning solvent fumes will void the warranty.
2
(871 cm2) is required for each dryer. (Based on
2
[6.5 cm2] per 1,000 Btu [252 kcal].)
A = 16-inches (40.6 cm) B = 17-inches (43.2 cm)
Exhaust Requirements _______________
Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure, which results in slow drying, increased use of energy, and shutdown of the burner by the airflow (sail) switch, burner hi-limits, or lint chamber hi-limit protector thermostat. The dryer must be installed with a proper exhaust duct connection to the outside.
The dryer shall not be exhausted into any gas vent, chimney , wall, ceiling or concealed space of a building.
Caution
This dryer produces combustible lint and must
!
be exhausted to the outdoors.
Improperly sized or installed exhaust ductwork can create a potential fire hazard.
The ductwork should be laid out in such a way that the ductwork travels as directly as possible to the outdoors with as few turns as possible. There should be a minimum 6-inch (15.24 cm) clearance between the back guard and the first bend in the ductwork for ease of servicing. Single or independent dryer venting is recommended. It is suggested that the use of 90° turns be avoided; use 30° and/or 45° bends instead. The radius of the elbows should preferably be 1-1/2 times the diameter of the duct. All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions, which will collect lint. When adding ducts, overlap the duct being connected. All ductwork joints must be taped to prevent moisture and lint from escaping into the building. Back draft dampers must be installed in all commonly ducted systems. Inspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and cleaning of lint from the ductwork.
Important: It is recommended that exhaust or booster fans not be used in the exhaust ductwork system.
Exhaust back pressure measured by a manometer/ magnehelic in the exhaust duct must be no less than 0 and must not exceed 0.6 in WC (1.48 mb).
Note: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening.
As per the National Fuel Gas Code, “Exhaust ducts for type 2 clothes dryers shall be constructed of sheet metal or
EXAMPLE: For a bank of four dryers, two unrestricted openings measuring 16-inches by 17-inches (40.6 cm by 43.2 cm) are acceptable.
Important: Make-up air must be free of dry cleaning solvent fumes. Make-up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components.
other noncombustible material. Such ducts shall be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 26 gauge (0.0195-inches [0.50 mm]) thick.”
The ductwork for this appliance must be suitable for the appliance category in accordance with national installation regulations of the country of destination.
113615-2 www.amdry.com 9
Outside Ductwork Protection
To protect the outside end of the horizontal ductwork from the weather, a 90° elbow bent downward should be installed where the exhaust exits the building. If the ductwork travels vertically up through the roof, it should be protected from the weather by using a 180° turn to point the opening downward. In either case, allow at least twice the diameter of the duct between the duct opening and the nearest obstruction (refer to the diagram).
Important: Do not use screens, louvers, or caps on the outside opening of the exhaust ductwork.
Single Dryer Venting
Important: For extended ductwork runs, the cross­sectional area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits as noted in this manual, a professional HVAC firm should be consulted for proper venting information.
Horizontal Venting
When horizontal dryer venting is used, the length of the ductwork from the dryer to the outside exhaust outlet, must not exceed 20 feet (6.10 meters). The minimum diameter of this ductwork must be at least 8-inches (20.32 cm). Including tumbler/dryer elbow connections or elbows used for outside protection from the weather, no more than 1 elbow should be used in the exhaust duct run. If more than 1 elbow is used, the cross-sectional area of the ductwork must be increased.
Vertical Venting
When vertical dryer venting is used, the length of the ductwork from the dryer to the outside exhaust outlet, must not exceed 20 feet (6.10 meters). The minimum diameter of this ductwork must be at least 8-inches (20.32 cm). Including tumbler/dryer elbow connections or elbows used for outside protection from the weather, no more than 3 elbows should be used in the exhaust duct run. If more than 3 elbows are used, the cross­sectional area of the ductwork must be increased.
A = 20 feet (6.10 meters) B = 8” (20.32 cm)
NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm)
larger than the duct (all the way around). The duct must be centered within this opening.
NOTE 2 Distance should be 2 times the diameter of the duct to the nearest
obstruction.
C = 20 feet (6.10 meters) D = 8” (20.32 cm)
Multiple Dryer (Common) Venting
Important: For extended ductwork runs, the cross­sectional area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits as noted in this manual, a professional HVAC firm should be consulted for proper venting information.
If it is not feasible to provide separate exhaust ducts for each dryer, ducts from individual dryers may be channeled into a “common main duct.” The individual ducts should enter the bottom or side of the main duct at an angle not more than 45º in the direction of airflow. The main duct should be tapered, with the diameter increasing before each individual duct is added.
Important: No more than 4 dryers should be connected to 1 main common duct.
The illustration on the next page shows the minimum cross­sectional area for multiple dryer round or square venting. These figures must be increased if the main duct run from the last dryer to where it exhausts to the outdoors is longer than 12 feet (3.656 meters) or has more than 1 elbow in it.
10 American Dryer Corp. 113615-2
A =8-inch (20.32 cm) B =12 feet (3.656 meters)
NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm)
larger than the duct (all the way around). The duct must be centered within this opening.
NOTE 2 Distance should be 2 times the diameter of the duct to the nearest
obstruction.
Multiple Dryer Venting with 8-Inch (20.32 cm) Diameter
640 cfm (18.12 cmm) Exhaust Connections at Common Duct
NUMBER OF D RYERS 4 3 2 1
MINIMUM CROSS-
SECTIONAL AREA
MINIMUM RO UND DUCT DIAMETER
SQ IN 164 120 80 54
SQ CM 1058 774.2 516.1 348.4
IN 14 12 10 8
CM 35.56 30.48 25.4 20.32
Electrical Information ________________
Electrical Requirements
All electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical installation is adequate and conforms to local, state, and national regulations or codes of the country of origin. In the absence of such codes, all electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
Important: Failure to comply with these codes or ordinances, and/or the requirements stipulated in this manual can result in personal injury or component failure.
Note: Component failure due to improper installation will void the warranty.
Each dryer should be connected to an independently protected branch circuit. The dryer must be connected with copper wire only. Do not use aluminum wire, which could cause a fire hazard. The copper conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes for making all service connections.
Note: The use of aluminum wire will void the warranty. An individual ground circuit must be provided to each
dryer, do not daisy chain. Component failure due to improper voltage application will
void the warranty.
The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
Important: A separate protected circuit must be provided to each dryer.
The dryer must be connected to the electric supply shown on the data label. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.
The wire size must be properly sized to handle the related current.
Warning
208 VAC and 240 VAC are not the same. Any
!
damage done to dryer components due to improper voltage connections will automatically void the warranty .
Warning (Gas Models Only)
Dryers built for use with a voltage between 200
!
and 240 must verify the input voltage during installation. If the nominal voltage is outside of the medium tolerances shown on the diagram below, adjust the autotransformer, located near the burner assembly. To adjust the autotransformer wiring, place the red wire on the appropriate tap (HIGH,
TERM
HIGH
MED
LOW
LINE VOLTAGE
50 Hz 60 Hz
260 226
239 208
217 189
283 249
260 230
236 208
MED, LOW) of the autotransformer. For additional wiring details, refer to the electrical diagram located on the inside of the control panel.
Electrical Service Specifications Gas and Steam Models Only
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT: NOTES
B.
C.
SERVICE
VOLTAGE
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage. When fuses are used they must be dual element, time delay, current limiting, class RK1 or
: A.
RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data. Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
PHASE
120 2 25.5 35 208 2 19.8 25 220 2 14.2 12.3 20 230 2 12.2 20 240 2 13.4 20
120 2 22.2 30 200 2 12.0 20 208 2 12.0 20 220 2 12.0 9.6 20 230 2 10.0 20 240 2 11.3 20
WIRE
SERVICE
APPROX. AMP DR AW
60 Hz 50 Hz
Gas
Steam
CIRCUIT
BREAKER
10/14/08
113615-2 www.amdry.com 11
Electric Models Only
All electrically heated dryers must be connected to the electric service shown on the dryer’s data label. The connecting wires must be properly sized to handle the rated current.
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
NOTES
B. C.
SERVICE
VOLTAGE
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5
: A.
ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data. Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appli ance amp draw rating and type of breaker used. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
PHASE
200 2 20.3 113.6 150 208 2 22.0 117.7 150 220 2 18.5 95.9 94.3 125 230 2 20.3 97.8 125 240 2 22.0 102.9 125 208 3 22.0 73.2 90 220 3 18.5 60.2 58.8 80 230 3 20.3 60.6 80 240 3 22.0 64.4 80
WIRE
SERVICE
OVEN
kW
APPROX.
AMP DRAW
60 Hz 50 Hz
CIRCUIT
BREAKER
10/14/08
Single-Phase (1ø) Wiring Connections/Hookup
The electrical input connections are made into the rear service box located at the upper right area of the dryer. The ground connection is made to the copper lug, also provided in this box. T o gain access, the service box cover must be removed.
Gas and Steam Models Only 120-240V Application with Neutral
Grounding
A ground (earth) connection must be provided and installed in accordance with local, state, and national regulations or codes of the country of origin. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at the location service panel.
For added personal safety, when possible, it is suggested that a separate ground wire (size per local codes) be connected from the ground connection of the dryer to a grounded cold water pipe. Do not ground to a gas pipe or hot water pipe. The grounded cold water pipe must have metal-to-metal connection all the way to the electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic, rubber, or other insulating connectors, they must be jumped out with a wire (size per local codes) and securely clamped to bare metal at both ends.
Important: For personal safety and proper operation, the dryer must be grounded.
Provisions are made for ground connection in each dryer at the electrical service connection area.
Electrical Connections
A wiring diagram is located behind the control panel for connection data.
If local codes permit, power to the dryer can be made by the use of a flexible UL listed power cord/pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer.
For CE Models Only
The means for disconnection from the supply must be incorporated into wiring having a minimum contact separation of 3.0 mm in all poles.
200-240V Application without Neutral
Caution
The dryer must be grounded. A ground lug
!
has been provided for this purpose.
Input connection wiring must be sized properly to handle the dryer’s current draw. This information is printed on the dryer’s data label.
Important: A strain relief must be used where the input wiring enters the oven assembly.
Electrically Heated Models Only
The electrical input connections are made at the rear service box located at the right upper section of the dryer. The ground connection is made to a copper lug also provided in this area. To gain access, remove rear service cover.
The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes neutral) and ground. Single-phase (1ø) power for the control circuit and for any single-phase (1ø) motors (if present) is done internally to the dryer by the factory at the oven contactor. No single-phase (1ø) input connection is required on a 3-phase (3ø) dryer.
The neutral will only be used on 4-wire service. This is typical for 380-416V, 50 Hz.
Caution
The dryer must be grounded. A ground lug
!
has been provided for this purpose.
12 American Dryer Corp. 113615-2
Input connection wiring must be sized properly to handle the dryer’s current draw. This information is printed on the dryer’s data label.
It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of all the appliance Btu being supplied.
Electric Models Only
Single-Phase (1ø) Wiring Connections / Hookup
Important: Failure to comply with these codes or ordinances, and/or the requirements stipulated in this manual, can result in personal injury and improper operation of the dryer.
For ease of service, the individual gas supply line of each dryer must have its own manual shutoff valve.
The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa) for non-CE dryers or 50 mb for CE dryers.
Failure to isolate or disconnect the dryer from supply as noted can cause irreparable damage to the gas valve, voiding the warranty.
Note: The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure test of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa) for non­CE dryers or 50 mb for CE dryers.
Warning
Fire or explosion could result due to failure of
!
isolating or disconnecting the gas supply as noted.
Note: Undersized gas piping will result in ignition problems, slow drying, increased use of energy, and can create a safety hazard.
3-Phase (3ø) Wiring Connections / Hookup
Gas Information ______________________
It is your responsibility to have all plumbing connections, materials, and workmanship conform to local and state regulations or codes of the country of destination. In the absence of such codes, all plumbing connections, materials, and workmanship must conform to the applicable local requirements. In the USA this is the National Fuel Gas Code ANSI Z223.1-LA TEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGAB149.2-M91 (L.P. Gas) or LATEST EDITION.
In Australia, the fuel gas code is AS 5601/AG 601, local authority, gas, electricity, and any other relevant statutory regulations.
The dryer must be connected to the type of heat/gas indicated on the data label and pressure must be confirmed. If this information does not agree with the type of gas available, do not operate the dryer. Contact the reseller who sold the dryer or contact the manufacturer.
The input ratings shown on the data label are for elevations up to 2,000 feet (610 meters), unless elevation requirements of over 2,000 feet (610 meters) were specified at the time the dryer order was placed with the factory . The adjustment or conversion of dryers in the field for elevations over 2,000 feet (610 meters) is made by changing each burner orifice. If this conversion is necessary, cont act the reseller who sold the dryer or contact the manufacturer.
Important: If connection to this appliance is made with a flexible hose, it must be suitable for the appliance category in accordance with national installation regulations of the country of destination, and if in doubt the installer must contact the supplier. The manufacturer of this appliance does not recommend the use of flexible gas supply line/ hose. An external gas supply shutoff must be provided.
CE and Australian Dryers
There is an N.P .T. to B.S.P. T . adaptor included with each dryer , which must be installed to the gas inlet. The adaptor is shipped in the tumbler.
Important: Pipe joint compounds that resist the action of natural, propane, and butane gases must be used.
113615-2 www.amdry.com 13
Heat Input/Gas Consumption/Orifice (Injector) Data
Gas Specifications for Non-CE and Non-AGA Approved Dryers**
Gas
Type
Natural 1,00 0 *Liquid Propane 2,500
Shaded areas are stated in metric equivalents * Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Nominal
He a ting Value
Btu/ft
Supply
Pressure
3
in WC B tu/hr kW DMS mm in WC
7.0-13.0
11.0
Heat Input
130,000 130,000
Gross
38.103
38.103
Orifice Size
3.9116
23
2.3749
42
Orifice
(Injector)
Quantity
2 2
Burner
Pressure
4.0
10.0
Piping/Connections
Inlet Connection – 1/2” M.N.P.T. CE and Australian dryer connections will be B.S.P.T ., all others
will be N.P.T. There should be a minimum 6-inch (15.24 cm) clearance
between the back guard and the first bend in the gas piping for ease of servicing. It is recommended that a gas shutoff valve be provided to the gas supply line of each dryer for ease in servicing.
The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same line, etc. Specific information regarding supply line size should be determined by the gas supplier.
Note: Undersized gas supply piping can create a low or inconsistent pressure, which will result in erratic operation of the burner ignition system.
TYPICAL NATURAL GAS INSTALLATION
Consistent gas pressure is essential at all gas connections. It is recommended that a 3/4-inch (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 13.0 in WC (32.34 mb) pressure.
A plugged tap, accessible for a pressure gauge connection, must be installed in the main gas supply line immediately upstream of the dryers.
Important: Pipe joint compounds that resist the action of natural, L.P., and butane gases must be used.
Test all connections for leaks by brushing on a soapy water solution (liquid detergent works well).
Warning
!
Never test for leaks with a flame!!!
NOTES _____________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
TYPICAL L.P. GAS INSTALLATION
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
14 American Dryer Corp. 113615-2
Gas Pressure Testing _________________
For proper operation, the gas pressure must be correct, consistent and maintained at the gas pressure rates shown on page 14. Provisions are made at the gas valve for taking gas pressure readings.
There are 2 types of devices used to measure gas pressure. They are the spring/mechanical type gauge and the manometer. The use of the spring/mechanical type gauge is not recommended because they are very easily damaged and are not always accurate. The preferred type of gauge is the manometer because it is a simple device to use and is highly accurate. A manometer is simply a glass or transparent plastic tube with a scale graduated in inches or millibar. When it is filled with water and pressure is applied, the water in the tube rises, showing the exact gas pressure.
Gas Pressure Test Procedure
Turn gas cock in gas supply line to “OFF” position. 50 Hz dryers: Back out miniature screw inside pressure tap
and attach manometer. 60 Hz dryers: Install pressure tap and attach manometer. Turn gas cock to “ON” position. Start the dryer in Heat Mode and wait for ignition. Gas
manifold pressure should be as shown on page 14. Once test is complete, turn gas cock to “OFF” position.
Remove manometer. Tighten screw inside the pressure tap or install plug.
Turn gas cock to “ON” position and check for leaks with soap solution with main burner “ON.”
Steam Information ____________________
It is your responsibility to have all plumbing connections made by a qualified professional to ensure that the steam plumbing installation is adequate and conforms with local, state, and country regulations or codes.
Care must be exercised when leveling steam dryers into final position. After leveling the dryer, check the downward pitch of the heat exchanger from front to rear with a level. Likewise, check the downward pitch of the return condensate manifold toward its outlet part. Absence of these downward pitches will result in probable water hammer and premature heat exchanger fracture and leakage.
The presence of condensate in the steam will cause water hammer and subsequent heat exchanger failure. The steam supply connection must be taken from the top of a well-dripped steam main. If the supply run-out to the dryer exceeds 25 feet (7.6 meters), it should be dripped just before the control valve with a proper trap and dirt pocket.
Important: Failure to comply with the requirements stipulated in this manual can result in component failure, which will void the warranty.
Steam Coil pH Level
The normal pH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For steel type steam coils the pH level must be maintained between a value of 9.5 to 10.5. These limits are set to limit the acid attack of the steam coils.
Important: Coil failure due to improper pH level will void the warranty.
113615-2 www.amdry.com 15
Steam Requirements – High Pressure
Water Information ____________________
Operating Steam Pressure
Maxi mum 150 psig* Heat Input (Normal Load) 5 Bhp Consumption (Approximate) 167 lb/hr Inlet / R et urn 3/4” / 3/4”
Shaded areas are stated in metric equivalents * The minimum operating pressure for optimum results is 100 psig (689.47
kPa).
Installation Instructions
To ensure an adequate supply of steam is provided, be sure that the steam supply lines and steam return lines are sized and laid out as stipulated in this manual. Inadequate steam supply lines and steam return lines or improper steam plumbing will result in poor performance and can cause component failure. Clean, dry steam must be provided to the dryer.
Important: Steam coil failure due to water hammer by wet steam will void the warranty.
The presence of condensate in the steam supply line will cause water hammer and subsequent heat exchanger (steam coil) failure. The steam supply connection into the main supply line must be made with a minimum 10-inch (25.4 cm) riser. This will prevent any condensate from draining towards the dryer.
The steam supply line to the dryer must include a 12-inch (30.48 cm) riser along with a drip trap and check valve. This will prevent any condensate from entering the steam coil.
Flexible hoses or couplings must be used. The dryer vibrates slightly when it runs and this will cause the steam coil connections to crack if they are hard piped to the supply and return mains.
Shutoff valves for each dryer should be installed in the supply line, return line, and drip trap return line. This will allow the dryer to be isolated from the supply main and the return main if the dryer needs maintenance work.
Install an inverted bucket steam trap and check valve at least 12-inches (30.48 cm) below the steam coil as close to the coil as possible. A trap with a minimum capacity of 272 lb (123.37 kg) of condensate per hour at 125 psi (8.62 bar) is needed for each unit. (Based on 2 times the steam consumption per hour.)
The supply line and the return line should be insulated. This will save energy and provide for the safety of the operator and maintenance personnel.
Water pockets in the supply line, caused by low points, will provide wet steam to the coil possibly causing steam coil damage. All horizontal runs of steam supply piping should be pitched 1/4-inch (6.35 mm) for every 1 foot (0.31 meters) back towards the steam supply header causing the condensate in the line to drain to the header. Inst all a bypass trap in any low point to eliminate wet steam.
Important: Flexible hoses/couplings must be used. Coil failure due to hard plumbing connections will void the warranty.
1.0 MPa
75.74 kg/hr
Before You Start Check Local Codes and Permits
Call your local water company or the proper municipal authority for information regarding local codes.
Important: It is your responsibility to have all plumbing connections made by a qualified professional to ensure that the plumbing installation is adequate and conforms to local, state, and federal regulations or codes.
It is the installer’s or owner’s responsibility to see that the required water pressure, pipe size, or connections are provided. The manufacturer assumes no responsibility if the fire suppression system is not connected, installed, or maintained properly.
Installation Water Supply
The fire suppression system must be supplied with a minimum water pipe size of 1/2-inch (12.7 mm) and be provided with 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure.
If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold/freezing temperatures, provisions must be made to protect these water lines from freezing.
Warning
If the water in the supply line or water solenoid
!
valve freezes, the fire suppression system will
be inoperative!!
Water Connections
The water connection is made to the 3/4”-11.5 NH hose adaptor, which is shipped in the tumbler and must be inst alled to the 1/2” N.P.T . water connection, located at the upper rear of the dryer. A flexible supply line/coupling must be used in an effort to avoid damaging the electric water solenoid valve.
Note: The 3/4”-11.5 NH is a standard hose coupling screw thread. It is not to be confused with 3/4” N.P.T. The sealing of an NH connection is made with a washer opposed to the mating threads of an N.P.T. assembly. The 2 thread designs are not compatible.
It is recommended that a filter or strainer be installed in the water supply line.
Important: Flexible supply line/coupling must be used. Solenoid valve failure due to hard plumbing connections will void warranty.
The dryer is to be connected to the water mains using a new hose set and the old hose set should not be reused.
Electrical Requirements
No independent external power source or supply connection is necessary. The 24-volt power to operate the fire suppression system is accomplished internally in the dryer (from the dryer controls).
16 American Dryer Corp. 113615-2
Warning
Electrical power must be provided to the dryer
!
at all times. If the main electrical power supply to the dryer is disconnected, the fire suppression system is inoperative!!
Preparation for Operation/Start-Up __
The following items should be checked before attempting to operate the dryer:
• Read all “CAUTION,” “WARNING,” and “DIRECTION”
labels attached to the dryer.
• Check incoming supply voltage to be sure that it is the
same as indicated on the data label. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service exactly.
• GAS MODELS – Check to ensure that the dryer is
connected to the type of heat/gas indicated on the dryer data label.
• GAS MODELS – Be sure that all gas shutoff valves are
in the open position.
• Be sure all back panels (guards) and electric box covers
are in place.
• Be sure the service doors are closed and securely in
place.
• Be sure the lint door/drawer is securely in place.
• Rotate the tumbler (drum) by hand to be sure it moves
freely.
• Check bolts, nuts, screws, terminals, and fittings for
tightness and security.
• Check that the vent is connected to the dryer and is
exhausted to the outdoors.
• STEAM MODELS – Check to ensure all steam shutoff
valves are open.
Note: Water column pressure requirements (measured at the pressure tap of the gas valve body) must be verified.
Important: In most cases there is no regulator provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank), or an external regulator must be added to each dryer.
Electrical Dryers
Check to ensure that electric oven/contactor assembly is activating.
Safety Related Circuits
Make a complete operational check of all safety related circuits:
• Door Switch(es)
• Hi-Limit Thermostats
• Sail Switch Make a complete operational check of all operating controls.
Tumbler Coating
The tumbler is treated with a protective coating. We suggest dampening old garments or cloth material with a solution of water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating.
Microprocessor Programs/Selections
Each microprocessor controller (computer) has been preprogrammed by the factory with the most commonly used parameter (program) selections. If computer program changes are required, refer to the computer programming manual, which was shipped with the dryer.
Preoperational Instructions __________
Preoperational Test __________________
All dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.
Turn on electric power to the dryer. Refer to the Operating Instructions for starting your particular
model dryer.
Gas Dryers
Open all shutoff valves. When a gas dryer is first started (during initial start-up), it
has a tendency not to ignite on the first ignition attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the lines.
Note: During the purging period, check to be sure that all gas shutoff valves are open.
A gas pressure test should be taken at the gas valve pressure tap of each dryer to ensure that the water column pressure is correct and consistent.
Important: For more detailed information regarding the microprocessor controller (computer), refer to the microprocessor user’s manual included with the dryer.
Coin Models
Microprocessor Controller (Computer)
When the microprocessor controller (computer) is in the ready state, the L.C.D. screen will display “Ready, Insert $XX.XX (amount) to Start”.
Insert coin(s). Once the correct “Amount to Start” has been inserted, the L.C.D. will display “Select Temperature”.
Select temperature by pressing “HI,” “MED,” or “LO.” The cycle will start and the L.C.D. will display the Dry Cycle selected and the remaining time.
The dryer will continue through the drying and cooling cycles, until the vended time has expired.
Note: To stop the dryer, open main door. Continuation of the cycle will resume only after the door has been closed and any one of the 3 temperature selections is pressed.
113615-2 www.amdry.com 17
Non-Coin Models
Microprocessor Controller (Computer)
The L.E.D. display reads “READY” (no cycle in progress). Press the letter on the keypad corresponding to the cycle
desired (e.g. key “D”). The dryer will then start (i.e. blower, tumbler, and heat). The L.E.D. display will read MANUAL DRYING CYCLE D,
___MIN REMAIN.
Note: The dryer can be stopped at any time by pressing the “STOP/CLEAR” key, at this time the dryer will go into a cycle pause. If the “STOP/CLEAR” key is pressed again at this point, the cycle that was in progress will be cancelled and returned to the “READY” state.
When the programmed drying time has expired, the non­coin microprocessor controller (computer) will proceed into the Cool Down Cycle.
Once the Cool Down Cycle begins at the end of the heat cycle, the L.E.D. display will read COOL DOWN TEMP __/__ MINUTES remaining. At the end of the heat cycle, the dryer will shut off the heat and continue the fan and tumbler until the Cool Down Time or temperature is reached.
Shutdown Instructions _______________
If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:
Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
Discontinue the heat supply: Gas Models – Discontinue the gas supply. Shut off external gas supply shutoff valve. Shut off internal gas supply shutoff valve located in the gas
valve burner area. Steam Models – Discontinue the steam supply. Shut off external (location furnished) shutoff valves.
Service/Parts Information ____________

Service

Service must be performed by a qualified trained technician. If service is required, contact the reseller from whom the equipment was purchased. If the reseller cannot be contacted or is unknown, contact the Service Department for a reseller in your area.
Note: When contacting the Service Department, be sure to give them the correct model number and serial number so that your inquiry is handled in an expeditious manner.

Parts

Replacement parts should be purchased from the reseller from whom the equipment was purchased. If the reseller cannot be contacted or is unknown, contact the Parts Department for a reseller in your area. Parts may also be purchased directly from the factory by calling the Parts Department at +1 (508) 678-9000 or you may FAX in your order at +1 (508) 678-9447.
Note: When ordering replacement parts from the reseller or the manufacturer, be sure to give them the correct model number and serial number so that your parts order can be processed in an expeditious manner.
Warranty Information _________________

Returning Warranty Cards

Before any dryer leaves the factory test area, a warranty card is placed on the inside of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you should you file a warranty claim.
If a warranty card did not come with your dryer, contact the Warranty Department or the Service Dep artment at +1 (508) 678-9000.
Important: A separate warranty card must be completed and returned for each individual dryer.
Note: Be sure to include the installation date when returning the warranty card(s).

Warranty

For a copy of the commercial warranty covering your particular dryer(s), contact the reseller from whom you purchased the equipment and request a dryer warranty form. If the reseller cannot be contacted or is unknown, warranty information can be obtained from the factory by contacting the Warranty Department at +1 (508) 678-9000.
Note: Whenever contacting the factory for warranty information, be sure to have the dryer’s model number and serial number available so that your inquiry can be handled in an expeditious manner.

Returning Warranty Parts

All dryer or parts warranty claims or inquiries should be addressed to the Warranty Parts Department. To expedite processing, the following procedures must be followed:
No parts are to be returned without prior written authorization R.M.A. from the factory.
Note: An R.M.A. is valid for only 30 days from date of issue.
The R.M.A. issued by the factory, as well as any other correspondence pertaining to the returned part(s), must be included inside the package with the failed merchandise.
Each part must be tagged with the following information: Model number and serial number of the dryer from which
part was removed. Nature of failure (be specific). Date of dryer installation. Date of part failure. Specify whether the part(s) being returned is for a credit,
replacement, or a refund.
Note: If a part is marked for a credit or a refund, the invoice number covering the purchase of the replacement part must be provided.
18 American Dryer Corp. 113615-2
Warranty tags (Part No. 450064) are available at “no charge” from ADC upon request.
The company returning the part(s) must clearly note the complete company name and address on the outside of the package.
All returns must be properly packaged to ensure that they are not damaged in transit. Damage claims are the responsibility of the shipper.
Important: No replacements, credits, or refunds will be issued for merchandise damaged in transit.
Note: To remove the lint drawer from the dryer, pull the drawer out loosen the torx screws on the sides of the rails. This allows the metal clips to rotate and allow the drawer to be fully removed. Reverse the above process for installation.
Important: The frequency of cleaning the lint screen can best be determined from experience at each location.
Weekly
Clean lint accumulation from lint chamber, thermostat, and microprocessor temperature sensor area.
All returns should be shipped to the factory in such a manner that they are insured and a proof of delivery can be obtained by the sender.
Shipping charges are not the responsibility of ADC. All returns should be “prepaid” to the factory. Any “C.O.D.” or “COLLECT” returns will not be accepted.
Important: No replacements, credits, or refunds will be issued if the claim cannot be processed due to insufficient information. The party filing the claim will be notified in writing, either by “FAX” or “CERTIFIED MAIL – Return Receipt Requested,” as to the information necessary to process claim. If a reply is not received by the Warranty Department within 30 days from the FAX/letter date, then no replacements, credits, or refunds will be issued, and the merchandise will be discarded.
Routine Maintenance _________________
Cleaning
A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent upon proper airflow. The accumulation of lint can restrict this airflow. If the guidelines in this section are met, the dryer will provide many years of efficient, trouble free, and most importantly, safe operation.
Warning
Lint from most fabrics is highly combustible.
!
The accumulation of lint can create a potential fire hazard. Keep dryer area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Note: Suggested time intervals shown are for average usage, which is considered 6 to 8 operational (running) hours per day.
Important: Dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint buildup.
Suggested Cleaning Schedule Every Third or Fourth Load
Clean the lint screen every third or fourth load. A clogged lint screen will cause poor dryer performance. The lint door/ drawer is located just below the loading door of the dryer. Open the lint door/drawer, brush the lint off the lint screen, and remove the lint. Inspect lint screen and replace if torn.
Warning
To avoid the hazard of electrical shock,
!
discontinue electrical supply to the dryer.
Steam Dryers
Clean the steam coil fins. It is suggested that compressed air and a vacuum cleaner with brush attachment be used.
Warning
When cleaning steam coil fins, be careful not
!
to bend the fins. If fins are bent, straighten by using a fin comb, which is available from local air­conditioning supply houses.
90 Days
Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment.
Clean any lint accumulation in and around the motor(s) casing opening.
Note: To prevent damage, avoid cleaning and/or touching ignitor/flame-probe assembly.
Every 6 Months
Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer’s internal exhaust ducting.
Note: The accumulation of lint in the exhaust ductwork can create a potential fire hazard.
Do not obstruct the flow of combustion and ventilation air. Check back draft dampers in the exhaust ductwork. Inspect and remove any lint accumulation, which can cause the damper to bind or stick.
A back draft damper that is sticking partially closed can result in slow drying and shutdown of heat circuit safety switches or thermostats.
When cleaning the dryer cabinet(s), avoid using harsh abrasives. A product intended for the cleaning of appliances is recommended.
7 Days After Installation and Every 12 Months Thereafter
A competent professional should inspect bolt s, nuts, screws, setscrews, grounding connections and nonpermanent gas connections (unions, shutoff valves, and orifices). Belts should be examined. Cracked or seriously frayed belts should be replaced. Complete an operational check of controls and valves. Complete an operational check of all safety devices (lint door/drawer switch, door switches, sail switch, and hi-limit thermostats).
113615-2 www.amdry.com 19
Data Label Information ____________________________________________________________
Standard Label
CE Label
AGA Label
When contacting ADC, the information on the data label is required to ensure proper service/parts assistance. The data label is located at the upper left rear of the dryer behind the back guard.
1. Model Number – This describes the style of dryer and type of heat (gas, electric, or steam).
2. Serial Number – Allows the manufacturer to gather information on your particular dryer.
3. Type of Heat – This describes the type of heat for your particular dryer, gas (either natural gas or L.P. gas), electric, or steam.
4. Heat Input (For Gas Dryers) – This describes the heat input in British thermal units per hour (Btu/hr) or kilowatts (kW).
5. Orifice Size (For Gas Dryers) – Gives the number drill size used.
6. Electric Service – This describes the voltage and current rating for a particular model.
7. Gas Manifold Pressure (For Gas Dryers) – This describes the manifold pressure taken at the gas valve tap.
20 American Dryer Corp. 113615-2
NOTES __________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
113615-2 www.amdry.com 21