These instructions provide installation information for installing a Wide Band Digital Radio
(WBDR) PCIx host card in a dedicated server.
Revision History
ISSUEDATEREASON FOR CHANGE
18/2004Original Publication
List of Changes
PAGEIDENTIFIERDESCRIPTION OF CHANGE
All—New document
Trademark Information
ADC and Digivance are registered trademarks of ADC Telecommunications, Inc.
Admonishments
Important safety admoni shmen ts are used throughou t thi s manual to warn of possi ble haza rds to
persons or equipment. An admonishment identifies a possible hazard and then explains what
may happen if the hazard is not avoided. The admonishments — in the form of Dangers,
Warnings, and Cautions — must be followed at all times. These warnings are flagged by use of
the triangular alert icon (seen below), and are listed in descending order of severity of injury or
damage and likelihood of occurrence.
Danger: Danger is used to indicate the presence of a hazard that will cause severe personal
injury, death, or substantial property damage if the hazard is not avoided.
Warning: Warning is used to indicate the presence of a hazard that can cause severe personal
injury, death, or substantial property damage if the hazard is not avoided.
Caution: Caution is used to indicate the presence of a hazard that will or can cause minor
personal injury or property damage if the hazard is not avoided.
General Safety Precautions
Caution: Elect ronic modules can be damage d by electrostatic di scharge (ESD). To prevent this,
take the following precautions:
• Wear an anti-static-discharge wrist strap while handling modules.
• Place modules in anti-static packing material when transporting or storing them.
Warni n g: To prevent electrical shock, never install equipment in a wet location or during a
lightning storm. When installing or modifying telephone lines, disconnect lines at the network
interface before working with uninsulated lines or terminals. Disconnect all power feeds before
working with uninsulated lines or terminals.
Danger: This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation
can seriously dama ge the retina of the eye. Do not look int o the ends of any optical fi ber. Do not
look directly into the optical transceiver of any digital unit or exposure to laser radiation may
result. An optical power meter should be used to verify active fibers. A protective cap or hood
MUST be immediately placed ov er a ny radiating transceiv er or optical fiber connec tor to avoid
the potential of dangerous amounts of radiation exposure. This practice also prevents dirt
particles from entering the transceiver or connector.
FCC/IC Compliance Statement
WBDR PCIx host card has been certified to comply with the requirements for Class B computing
devices per part 15 of the FCC regulations and applicable sections of Title 47 CFR Part 22.
ADCP-75-163WB • Issue 1 • August 2004
Warning: This equipment generates, uses, and can radiate radio frequency energy and if not
installed and used in accordance with the instruction manu al, may cause interference to radi o
communications. It has b een tested and found to comply with limits for a Class B d igital devic e
pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable
protection against such interference when operated in a residential environment. If interference
to TV and radio reception does occur relocate or reorient the antenna of the affected radio or TV .
This equipment does not exceed Class B limits for radio emission for digital apparatus, set out
in the radio interference regulation of the authorization methods of Industry Canada.
This equipment complies with the applicable sections of RSS-131. The term “IC:” before the
radio certification number only signifies that Industry C anada Technical Specifications were met.
This product conforms to all applicable standards of 21 CFR 1040.
Certification: UL/CSA Recognized
WBDR PCIx host card has been tested and found to comply with the requirements of UL/CSA
60950.
1DESCRIPTION
Wide Band Digital Radio (WBDR), refers to wireless communication in which the transmitter
modulation is generated and receiver demodulation recovered by software operating on a
computer. To select the desired modulation and demodulation type, configuration programs
must be run by microcomputers controlling the transmitter and receiver.
The most significant asset of WBDR is versatility. Wireless systems employ protocols that vary
from one service to another. Even in the same type of service, for example wireless fax, the
protocol often differs from country to country. A single WBDR set with an all-inclusive
software repertoire can be used in any mode, anywhere in the world. Changing the service type,
the mode, and/or the modulation protocol involves simply selecting and launching the requisite
computer program. A WBDR PCIx Host Card is shown in Figure 1.
PIN
1
19307-A
Figure 1. WBDR PCIx Host Card
Wide Band Digital Radio (WBDR) allows a single device to adapt to different communications
environments and systems by selecting the most appropriate protocol and frequency needed for
a link. One device may work with a wireless local area network protocol in the city, and then be
reconfigured to work with terrestrial and satellite protocols to deliver broadband applications to
rural and remote areas.
WBDR works much like desktop computing, where a single hardware platform carries out
many functions based on the software applications loaded. WBDR uses software to perform
radio-signal processing functions instead of using resistors, capacitors, feedback loops, or
application-specific integrated circuits.
The WBDR PCIx host card is installed in a server and cabled to the LRCS remote (radio head)
units and the GPS receiver. Power is provided by the server with configuration and software
management through the server communications interface. Communications with the network
is through the server and associated hardware and software.
2WBDR CARD INSTALLATION
2.1Power Down the Server
Warning: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On switch may
not completely shut off system power. Portions of the power supply and some internal circuitry
may remain active until AC power is removed.
1. Back up the server data.
ADCP-75-163WB • Issue 1 • August 2004
2. Shut down the operating system as directed by the operating system documentation.
3. If the server is installed in a rack, locate the server.
4. Some servers may have a standby mode, if your server has a standby mode, press the
Power On/Standby button to place the server in standby mode. When the server activates
standby power mode, the system power LED should indicate the change to standby mode.
5. Disconnect the power cords. Server is now without power.
2.2Extend Server from the Rack
Loosen the thumbscrews that secure the server faceplate to the front of the rack. Extend the
server on the rack rails until the server rail-release latches engage.
Warning: To reduce the risk of personal injury or equipment damage, be sure that the rack is
adequately stabilized before extending a component from the rack.
Warning: To reduce the risk of personal in j ury, be careful when pres sin g t he s erver rail-release
latches and sliding server into the rack. The sliding rails could pinch your fingers.
2.3Remove Access Panel
Warning: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
Caution: Do not operate the server for long periods without the access panel. Operating the
server without the access panel results in improper airflow and improper cooling that can lead
to thermal damage.
Lift up on the hood latch handle and remove the access panel.
Caution: To prevent damage to the server or expansion boards, power down the server and
remove all AC or DC power cords before removing or installing the PCI riser cage.
1. If necessary, disconnect any internal or external cables connected to all expansion boards.
2. Lift the PCI riser cage thumbscrews and turn them counter-clockwise.
3. Remove the PCI riser cage.
2.5Remove Expansion Slot Cover
Most servers contain a P CI-X backplane that is part of the PCI riser cage. The PCI bac kplane
normally provides hot-plug capability to two expansion slots and a third non-hot-plug exp ansion
WBDR
slot.
specification; 64-bit/133-MH z 3.3V. Determine which slot th e
and remove the expansion slot cover.
PCIx Host card is installed in the non-hot-plug PCI-X expansion slot that meets the
WBDR
card is to be installed in
Caution: To prev ent i mpr o per cool ing an d th ermal dama ge, do not operat e the s erver unless all
PCI slots have either an expansion slot cover or an expansion board installed.
2.6Installing a WBDR PCIx Host Card
Caution: Elect ronic modules can be damaged by electrostati c disch ar g e (ESD). To prev ent thi s,
take the following precautions:
• Wear an anti-static-discharge wrist strap while handling modules.
• Place modules in anti-static packing material when transporting or storing them.
1. Slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an
earth ground source. Wear the ESD wrist strap while completing the WBDR PCIx Host
Card installation procedure.
2. Unlock the PC I retaining clip.
3. Install the card.
4. Lock the PCI retaining clip.
5. Power, network interface, and communications to the card are supplied through the card
edge connector.
2.7Install PCI Riser Cage
Caution: To prevent damage to the server or expansion boards, power down the server and
remove all AC power cords before removing or installing the PCI riser cage.
1. Align the PCI riser cage with the chassis and slide it into place.
2. Tighten the screws to secure the PCI riser cage.