AD-464 Models
MAXIMUM CAPACITY (DRY WEIGHT) 460 lb 208.65 kg
MINIMUM LOAD SIZE 250 lb 113.40 kg
TUMBLER DIAMETER 69-1/8" 175.59 cm
TUMBLER DEPTH
TUMBLER VOLUME
DOOR OPENING (WIDTH X HEIGHT)
DOOR SILL HEIGHT, LEVEL
DOOR SILL HEIGHT, REAR TILT
DOOR SILL HEIGHT, FRONT TILT
CABINET OPERATING DEPTH, LEVEL (1-DOOR/2-DOOR)
CABINET WIDTH
REAR TILT
FRONT TILT
WATER CONNECTION
CABINET REAR-TILT HEIGHT
CABINET OPERATING HEIGHT, LEVEL
CABINET FULL-TILT DEPTH
APPROX. NET WEIGHT
APPROX. SHIPPING WEIGHT
VOLTAGE AVAILABLE
TUMBLER/DRIVE MOTOR
BLOWER/FAN MOTOR
BURNER BLOWER MOTOR
BURNER TYPE
HEAT INPUT
INLET PIPE CONNECTION (NON-TILT/TILT)
MAXIMUM GAS PRESSURE
AIRFLOW
MAXIMUM EXHAUST BACK PRESSURE
EXHAUST DIAMATER
COMPRESSED AIR PRESSURE
COMPRESSED AIR VOLUME (1-WAY/2-WAY TILT)
COMPRESSED AIR CONNECTION (NON-TILT/TILT)
CABINET REAR-TILT HEIGHT
CABINET OPERATING HEIGHT, LEVEL
CABINET FULL-TILT DEPTH
APPROX. NET WEIGHT
APPROX. SHIPPING WEIGHT
VOLTAGE AVAILABLE
TUMBLER/DRIVE MOTOR
BLOWER/FAN MOTOR
BOILER HORSEPOWER (NORMAL LOAD)
SUPPLY CONNECTION
RETURN CONNECTION (NON-TILT/TILT)
Steam Gas
STEAM CONSUMPTION
AIRFLOW
MAXIMUM EXHAUST BACK PRESSURE
EXHAUST DIAMETER
COMPRESSED AIR PRESSURE
COMPRESSED AIR VOLUME (1-WAY/2-WAY TILT)
COMPRESSED AIR CONNECTION (NON-TILT/TILT)
Shaded areas are stated in metric equivalents
IMPORTANT: 208 VAC and 230/240 VAC are not the same. When ordering, specify voltage.
NOTES: A. Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appli-
ance amp draw rating and type of breaker to be used.
B. Circuit breakers for 3ø dryers must be 3-pole type.
Voltage Phase Wire Service Hz Total Current Circuit Breaker Fuse Wire Size
208 3 3/4 60 111 150 150 1/0
220 3 3 60 107 150 150 1/0
240 3 3 60 105 150 150 1/0
460 3 3 60 56 70 70 3
480 3 3 60 56 70 70 3
230 3 3 50 113 150 150 1/0
380 3 3/4 50 62 80 80 3
400 3 3/4 50 59 80 80 3
416 3 3/4 50 61 80 80 3
GAS - All-Door / All-Tilt - Electrical Service Specifications
AD-464
80-5/16" 203.99 cm
175 cu ft 4955.44 L
53-1/4" x 49" 135.26 cm x 124.46 cm
45" 114.30 cm
43-3/4" 111.13 cm
65-5/8" 166.70 cm
95" / 95" 241.30 cm / 241.30 cm
122" 309.88 cm
138-1/4" 351.16 cm
121" 307.34 cm
118" 299.72 cm
10,270 lb 4,658.39 kg
10,425 lb 4,728.70 kg
208-480v 3ø 3,4w 50/60 Hz
7-1/2 hp 5.59 kW
25 hp 18.64 kW
1-1/2 hp 1.12 kW
2,800,000 Btu/hr 705,588 kcal/hr
12 in WC 29.89 mb
13,000 cfm 368.12 cmm
1.25 in WC 3.11 mb
24" 60.96 cm
80 psi (± 10 psi) 5.52 bar (± 0.69 bar)
15 cfh / 19 cfh 0.42 cmh / 0.54 cmh
138-1/4" 351.16 cm
121" 307.34 cm
118" 299.72 cm
11,000 lb 4,989.52 kg
11,162 lb 5,063 kg
208-480v 3ø 3,4w 50/60 Hz
7-1/2 hp 5.59 kW
25 hp 18.64 kW
2,071 lb/hr 939.39 kg/hr
13,000 cfm 368.12 cmm
1.25 in WC 3.11 mb
24" 60.96 cm
80 psi (± 10 psi) 5.52 bar (± 0.69 bar)
16 cfh / 20 cfh 0.45 cmh / 0.57 cmh
15°
15°
1" F.N.P.T.
On / O
2-1/2" F.N.P.T.
3/8" F.N.P.T.
60 Bhp
2-1/2" F.N.P.T.
1-1/4" F.N.P.T.
3/8" F.N.P.T.
IMPORTANT: 208 VAC and 230/240 VAC are not the same. When ordering, specify voltage.
NOTES: A. Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appli-
ance amp draw rating and type of breaker to be used.
B. Circuit breakers for 3ø dryers must be 3-pole type.
Voltage Phase Wire Service Hz Total Current Circuit Breaker Fuse Wire Size
208 3 3/4 60 106 150 150 1/0
240 3 3 60 100 150 150 1/0
460 3 3 60 53 70 70 4
480 3 3 60 53 70 70 4
230 3 3 50 107 150 150 1/0
380 3 3/4 50 60 80 80 3
400 3 3/4 50 57 80 80 3
416 3 3/4 50 58 80 80 3
STEAM - All-Door / All-Tilt - Electrical Service Specifications