All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
Electrolytic: 6x Jun Fu (2-5,000h @ 105°C, WL), 4x Jun Fu (2,000h @ 105°C, WG), 3x CapXon (2-5,000h @ 105°C, KF), 4x
CapXon (2,000h @ 105°C, GF)
Polymer: 2x APAQ
XPG Pylon 550W Bronze
5VSB Circuit-
Standby PWM ControllerPower Integrations TNY287PG
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
115V
Average Efficiency84.893%
Efficiency With 10W (≤500W) or 2% (>500W)63.247
Average Efficiency 5VSB79.871%
Standby Power Consumption (W)0.0385924
Average PF0.982
Avg Noise Output30.82 dB(A)
Efficiency Rating (ETA)ETA-S
Noise Rating (LAMBDA)LAMBDA-S++
230V
Average Efficiency87.000%
Average Efficiency 5VSB78.589%
Standby Power Consumption (W)0.0762105
Average PF0.952
Avg Noise Output29.41 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-A-
XPG Pylon 550W Bronze
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)14.2
AC Loss to PWR_OK Hold Up Time (ms)13
PWR_OK Inactive to DC Loss Delay (ms)1.2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
XPG Pylon 550W Bronze
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
XPG Pylon 550W Bronze
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.229
72.930%
5.089V0.314115.16V
0.090A0.458
77.365%
5.089V0.592115.16V
0.550A2.793
80.933%
5.080V3.451115.14V
1.000A5.071
81.540%
5.071V6.219115.14V
1.500A7.589
79.558%
5.060V9.539115.14V
2.499A12.596
76.946%
5.040V16.370115.14V
0.034
0.062
0.262
0.342
0.389
0.434
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.229
63.085%
5.090V0.363230.30V
0.090A0.458
70.353%
5.089V0.651230.30V
0.550A2.794
77.418%
5.080V3.609230.31V
1.000A5.071
79.470%
5.071V6.381230.31V
1.500A7.590
79.996%
5.060V9.488230.30V
2.499A12.598
79.896%
5.041V15.768230.30V
0.013
0.023
0.114
0.181
0.234
0.301
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
XPG Pylon 550W Bronze
115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 6/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 115V
XPG Pylon 550W Bronze
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 7/16
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -115V
XPG Pylon 550W Bronze
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 115V
Test #12V5V3.3V5VSB
2.739A2.001A2.016A0.989A54.956
1
12.176V4.998V3.277V5.055V66.50737.82°C115.16V
6.506A3.004A3.024A1.190A110.013
2
12.160V4.994V3.273V5.042V127.32738.52°C115.16V
10.617A3.506A3.533A1.393A165.006
3
12.146V4.991V3.269V5.028V188.61939.74°C115.16V
14.738A4.012A4.043A1.595A220.002
4
12.131V4.988V3.266V5.015V251.25641.20°C115.16V
18.528A5.015A5.059A1.800A274.992
5
12.116V4.985V3.263V5.000V315.78742.66°C115.15V
DC/AC
(Watts)
Efficiency
82.632%87721.8
86.402%88021.9
87.481%88222.1
87.561%88622.7
87.081%89023.0
Fan Speed
(RPM)
PSU Noise
(dB[A])
XPG Pylon 550W Bronze
Temps
(In/Out)
34.52°C0.945
34.58°C0.971
35.13°C0.978
35.95°C0.985
36.53°C0.988
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
22.328A6.021A6.074A2.000A329.948
86.399%89522.9
12.100V4.984V3.260V4.984V381.88944.34°C115.15V
26.144A7.030A7.095A2.214A385.048
85.472%106626.7
12.084V4.981V3.257V4.968V450.49845.58°C115.15V
29.968A8.003A8.114A2.422A439.824
84.337%139834.8
12.066V4.978V3.253V4.953V521.50847.12°C115.14V
34.189A8.545A8.617A2.428A494.512
83.381%172040.6
12.051V4.974V3.249V4.943V593.07248.11°C115.14V
38.427A9.056A9.148A2.535A549.631
82.340%205845.0
12.034V4.970V3.246V4.930V667.51349.35°C115.13V
43.080A9.061A9.157A2.540A604.851
81.306%237546.0
12.016V4.967V3.243V4.921V743.91751.15°C115.13V
0.100A13.000A12.997A0.000A108.520
80.041%90922.9
12.148V4.991V3.264V5.035V135.58142.93°C115.17V
45.503A1.000A1.001A1.000A561.116
83.229%207245.7
12.041V4.977V3.256V4.978V674.18349.49°C115.14V
37.09°C0.990
37.53°C0.991
38.01°C0.992
38.54°C0.992
39.27°C0.993
40.50°C0.993
36.99°C0.974
39.59°C0.993
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 10/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
XPG Pylon 550W Bronze
230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 11/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 230V
XPG Pylon 550W Bronze
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 12/16
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -230V
XPG Pylon 550W Bronze
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 13/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 230V
Test #12V5V3.3V5VSB
2.740A2.000A2.013A0.989A54.956
1
12.176V4.998V3.277V5.056V65.50137.17°C230.30V
6.506A3.003A3.023A1.190A110.014
2
12.161V4.995V3.273V5.043V124.99938.52°C230.31V
10.615A3.508A3.533A1.392A165.004
3
12.147V4.991V3.270V5.030V185.03539.60°C230.30V
14.736A4.009A4.043A1.595A219.999
4
12.133V4.988V3.267V5.017V246.01640.50°C230.30V
18.524A5.015A5.057A1.799A274.983
5
12.118V4.986V3.264V5.002V308.51841.88°C230.30V
DC/AC
(Watts)
Efficiency
83.901%87421.7
88.012%87721.8
89.174%87921.9
89.425%88222.1
89.130%88722.9
Fan Speed
(RPM)
PSU Noise
(dB[A])
XPG Pylon 550W Bronze
Temps
(In/Out)
34.01°C0.823
34.73°C0.913
35.12°C0.944
35.35°C0.960
36.09°C0.964
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
22.322A6.020A6.071A2.000A329.946
88.648%89322.9
12.103V4.985V3.261V4.988V372.19843.35°C230.30V
26.136A7.026A7.090A2.212A385.040
87.867%104726.5
12.088V4.983V3.258V4.972V438.20845.07°C230.29V
29.954A8.000A8.111A2.420A439.798
87.017%139934.8
12.071V4.979V3.254V4.958V505.41546.27°C230.29V
34.175A8.543A8.610A2.425A494.472
86.279%171140.5
12.055V4.975V3.251V4.948V573.10547.71°C230.29V
38.408A9.050A9.143A2.532A549.588
85.447%206945.6
12.039V4.972V3.248V4.937V643.19249.21°C230.29V
43.052A9.057A9.152A2.536A604.803
84.683%237446.0
12.023V4.969V3.244V4.927V714.19651.20°C230.29V
0.101A13.001A13.000A0.000A108.534
81.430%90922.9
12.151V4.990V3.264V5.037V133.28541.65°C230.31V
45.498A1.000A1.000A1.000A561.289
86.375%209045.6
12.046V4.979V3.257V4.983V649.82749.55°C230.29V
36.80°C0.972
37.43°C0.977
37.95°C0.981
38.11°C0.984
39.02°C0.987
40.53°C0.988
36.42°C0.922
39.20°C0.987
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 15/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
Anex
XPG Pylon 550W Bronze
CERTIFICATIONS 115V
CERTIFICATIONS 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 16/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.