Information in this document is subject to change without notice and does not
represent a commitment on the part of Adaptec or any of its subsidiaries. The
software described in this document is furnished under a license agreement. The
software may be used only in accordance with the terms of the license agreement.
It is against the law to copy the software on any medium. No part of this manual
may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, for any purpose without the
express written permission of Adaptec, Inc.
TRADEMARKS
Adaptec, the Adaptec logo, Snap Server, the Snap Server logo, GuardianOS,
SnapOS, and Snap Disk are trademarks or registered trademarks of Adaptec, Inc.
in the U.S.A. and other countries.
Products mentioned herein are for identification purposes only and may be
registered trademarks or trademarks of their respective companies.
REVISIONS
Adaptec, Inc. provides this publication “as is” without warranty of any kind,
either express or implied, including but not limited to the implied warranties of
merchantability or fitness for a particular purpose. Adaptec and its subsidiaries
reserve the right to revise this publication and to make changes in the content
hereof without the obligation of Adaptec to notify any person of such revision or
changes.
SANBloc S50 Quick Install
Guide
The SANbloc S50 JBOD enclosure supports up to 12 Serial Attached SCSI
(SAS), 12 Serial ATA (SATA) disk drives, or a combination of SAS and
SATA drives (up to 12 drives total). A maximum of seven (7) S50s can be
chained to each Snap Server.
This Quick Installation Guide describes how to install the SANbloc S50
enclosure and connect it to a 500/600 Series Snap Server.
Note To connect the SANbloc S50 enclosure, your Snap Server must be
installed with a Serial Attached SCSI (SAS) host adapter.
1SANBloc S50 Quick Install Guide
Enclosure Features and Accessories
11
1
3456
HOST
FAULT !
SEP MASTER
789
1 Pre-installed disk drives (4 or 12) and
3
EXP
10
2
13
Q
ui
I
ck
n
s
t
Guid
a
l
l
e
8 SAS I/O controller status LEDs
pre-installed drive carrier blanks (8
blanks if 4 drives are pre-installed)
2 Enclosure status LEDs9 SAS HOST connector
3 Advanced Power and Cooling units
10 SAS EXP connector
(two)
4 On/off switch 11 Rackmount kit
5 Power connector 12 Power cables for all regions (6
total)
6 APC unit status LEDs 13 External 4x SAS cable
7 SAS I/O controller14 Quick Install Guide
12
14
SANBloc S50 Quick Install Guide2
Installing Your Adaptec Enclosure into a Rack
S
1 Ensure that you have these rackmount kit components:
• Front rails (1 left, 1 right)
• Rear rails, two different lengths (2 left, 2 right)
• 20 nuts (10 each of two different types)
• 4 small screws and 10 large screws
2 Secure the front rails to the front supports of the rack, using the screws
or nuts included in the kit. (Use the nuts if your rack does not have
threaded holes.)
)
ecure rear rail, using rail
length suitable for your rack
Rear support
Front
support
3 Select the right length of rails for your rack, then secure them to the
Secure front rail
rear supports of the rack, as shown above. Then secure the front rails to
the rear rails.
Ensure that all the rail connections are tightened and secure.
3SANBloc S50 Quick Install Guide
4 Remove the plastic covers from the enclosure’s rackmount ears.
Caution
The enclosure is heavy.
To avoid personal injury, have
someone help you lift it.
5 Slide the enclosure onto the rails, then push it all the way back until the
rackmount ears are flush against the front vertical supports and the
enclosure rests completely on the rails.
Rackmount ears
rest against vertical
6 Secure both rackmount ears to the front vertical supports.
Secure to the front vertical
supports
SANBloc S50 Quick Install Guide4