Adaptec SANBLOC S50 User Manual

Using the SANbloc S50 JBOD Enclosure with Snap Servers
Quick Install Guide
SANbloc S50 JBOD Enclosure Quick Start Guide
www.snapserver.com
COPYRIGHT
Copyright © 2007, Adaptec, Inc. All rights reserved worldwide.
TRADEMARKS
Adaptec, the Adaptec logo, Snap Server, the Snap Server logo, GuardianOS, SnapOS, and Snap Disk are trademarks or registered trademarks of Adaptec, Inc. in the U.S.A. and other countries.
Products mentioned herein are for identification purposes only and may be registered trademarks or trademarks of their respective companies.
REVISIONS
Adaptec, Inc. provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Adaptec and its subsidiaries reserve the right to revise this publication and to make changes in the content hereof without the obligation of Adaptec to notify any person of such revision or changes.
SANBloc S50 Quick Install Guide
The SANbloc S50 JBOD enclosure supports up to 12 Serial Attached SCSI (SAS), 12 Serial ATA (SATA) disk drives, or a combination of SAS and SATA drives (up to 12 drives total). A maximum of seven (7) S50s can be chained to each Snap Server.
This Quick Installation Guide describes how to install the SANbloc S50 enclosure and connect it to a 500/600 Series Snap Server.
Note To connect the SANbloc S50 enclosure, your Snap Server must be
installed with a Serial Attached SCSI (SAS) host adapter.
1 SANBloc S50 Quick Install Guide

Enclosure Features and Accessories

11
1
34 5 6
HOST
FAULT !
SEP MASTER
7 8 9
1 Pre-installed disk drives (4 or 12) and
3
EXP
10
2
13
Q
ui
I
ck
n
s
t
Guid
a
l
l
e
8 SAS I/O controller status LEDs
pre-installed drive carrier blanks (8 blanks if 4 drives are pre-installed)
2 Enclosure status LEDs 9 SAS HOST connector 3 Advanced Power and Cooling units
10 SAS EXP connector
(two)
4 On/off switch 11 Rackmount kit 5 Power connector 12 Power cables for all regions (6
total)
6 APC unit status LEDs 13 External 4x SAS cable 7 SAS I/O controller 14 Quick Install Guide
12
14
SANBloc S50 Quick Install Guide 2

Installing Your Adaptec Enclosure into a Rack

S
1 Ensure that you have these rackmount kit components:
• Front rails (1 left, 1 right)
• Rear rails, two different lengths (2 left, 2 right)
• 20 nuts (10 each of two different types)
• 4 small screws and 10 large screws
2 Secure the front rails to the front supports of the rack, using the screws
or nuts included in the kit. (Use the nuts if your rack does not have threaded holes.)
)
ecure rear rail, using rail
length suitable for your rack
Rear support
Front support
3 Select the right length of rails for your rack, then secure them to the
Secure front rail
rear supports of the rack, as shown above. Then secure the front rails to the rear rails.
Ensure that all the rail connections are tightened and secure.
3 SANBloc S50 Quick Install Guide
4 Remove the plastic covers from the enclosure’s rackmount ears.
Caution
The enclosure is heavy.
To avoid personal injury, have
someone help you lift it.
5 Slide the enclosure onto the rails, then push it all the way back until the
rackmount ears are flush against the front vertical supports and the enclosure rests completely on the rails.
Rackmount ears rest against vertical
6 Secure both rackmount ears to the front vertical supports.
Secure to the front vertical supports
SANBloc S50 Quick Install Guide 4