Adams F10, F16, F20, Fh1000-l10, Fh1000-l20 Owner's Manual

...
5 (1)
Adams F10, F16, F20, Fh1000-l10, Fh1000-l20 Owner's Manual

A l l H u m i d i f i e r s A r e N o t C r e a t e d E q u a l .

Why you need humidity

Outside air infiltrates your home to replace the thousands of cubic feet of air consumed by your furnace, water heater and fireplace. When this air is heated, it dries out your home. You need to replace this moisture with a humidifier.

As an example, if outside air at 20° with 60% relative humidity infiltrates your home and is heated to 72°, the relative humidity drops to only 8%. You need 25-45% for comfort and well being, but outside air infiltrates your home and robs you of the necessary humidity.

Proper humidity makes you feel more comfortable, protects your home and furnishings from drying and cracking, and reduces annoying static electricity that shocks you when you touch anything metal. Because you are comfortable with a lower thermostat setting, you can save from 10% to 20% on your fuel bill, too.

?How do they work

Humid-Aire humidifiers are the answer to all the dry air problems in your home. When the relative humidity drops below the set point, the humidifier will automatically begin to supply water to the water pad or media. As the dry air passes through the water media or pad, air is humidified and carried throughout your home as water vapor. As a result, lower heating costs are achieved. In addition this stops wood shrinkage, static electricity and other problems which normally occur without humidity.

All Humid-Aire humidifiers produce humidity in a safe and pure water vapor form. No mist or droplets are present which can carry impurities. All minerals and impurities left from the evaporation process are flushed down the drain with ease.

MODEL

FH 182H

FH214H

FH212H

FH200H

FH400(A,B,C)

 

 

 

 

 

 

Type

Bypass flow-through

Self-powered

Power rotating pad

Power rotating pad

Power rotating disc

flow-through

by-pass

by-pass

 

 

 

Mounting

Plenum or return supply

Warm air plenum

Plenum or return supply

Plenum or return supply

Under duct supply side

Location

 

 

 

 

 

Capacity

 

 

 

 

 

19.4

21.4

21.2

20.0

13,24, or 32

Gal/Day

 

 

 

 

 

Approx. capacity

2800

3200

3200

3200

1800,3600 or 4500

in sq. ft.

 

 

 

 

 

 

 

 

 

 

 

Voltage

120 or 24

120

24

24

120

Reservoir or

Fiberglass

Fiberglass

Stainless Steel

Plastic

Lexan

Housing

 

 

 

 

 

Media

 

 

 

 

 

Coated Aluminum pad

Coated Aluminum pad

Foam pad

Foam pad

Bronze Disc

Unit HxWxD

14-1/2"x15-1/4-"x8-1/4"

14-1/2"x15-1/4-"x10-3/4"

10-1/2x"11-5/8"x11-1/2"

10"x"13-1/2"x11-1/2"

8-1/2"x"13"x20-3/4"

Plenum Opening

 

 

 

 

 

10-1/4"x9-1/8"

10-1/4"x13-3/4"

6-1/4"x7-1/2"

6-1/8"x7-1/2"

11"x12-3/4"

HxW

 

 

 

 

 

Features

• By-pass damper

• Integral fan and motor

• Flexible by-pass duct

• Flexible by-pass duct

• Heavy duty gear motor

 

• Built-in leveling bubble

• Power Cord

• 24V transformer

• 24V transformer

• Separate float

 

• Saddle valve

• Built-in Transformer

• 24V motor

• 24V motor

compartment

 

• 6" starting collar

& Relay

• Adjustable float

• Adjustable float

• External water level

 

• Wall/Duct Mounted

• Wall/Duct Mounted

• Saddle valve

• Saddle valve

• Air Deflector

 

humidistat

humidistat

• Water supply tubing

• Water supply tubing

• Saddle valve

 

• 15 ft. drain tubing

• 15 ft. drain tubing

• Wall/duct mount

• Wall/duct mount

• Tilt-in/tilt out mounting

 

• Right or left hand

• Built-in Leveling

humidistat

humidistat

• Optional Sentinel Auto

 

air inlet

bubble

• Right or left hand

• Right or left hand

Flush

 

• Completely factory

 

air inlet

air inlet

• Adjustable float

 

assembled

 

 

 

 

 

 

 

 

 

 