Adams CFW 300, CFW 150, CFW 600, CFW 60 User Manual

Adam Equipment
CFW SERIES
(P.N. 6162, Revision A5, May 2006)
Software Version: V1.04
@Adam Equipment Company 2006
CONTENTS
1.0 INTRODUCTION............................................................................................................3
2.0 SPECIFICATIONS.........................................................................................................4
3.0 INSTALLATION..............................................................................................................6
3.1 LOCATING THE SCALES..........................................................................................6
3.2 LIST OF ACCESSORIES...........................................................................................6
3.3 SETTING UP THE SCALES.......................................................................................7
4.0 KEY DESCRIPTIONS....................................................................................................8
5.0 DISPLAYS .....................................................................................................................9
6.0 OPERATION................................................................................................................10
6.1 ZEROING THE DISPLAY.........................................................................................10
6.2 TARING....................................................................................................................10
6.3 WEIGHING A SAMPLE............................................................................................11
6.4 PARTS COUNTING .................................................................................................11
6.5 CHECK-WEIGHING.................................................................................................13
6.5 ACCUMULATED TOTAL ..........................................................................................14
7.0 USER PARAMETERS .................................................................................................16
8.0 BATTERY OPERATION ..............................................................................................19
9.0 RS-232 INTERFACE....................................................................................................20
9.1 INPUT COMMANDS FORMAT ................................................................................21
10.0 CALIBRATION.............................................................................................................22
11.0 SERVICE SECTION ....................................................................................................23
11.1 CFW FACTORY PROGRAMMING AND CALIBRATIONS .......................................23
12.0 ERROR CODES ..........................................................................................................26
13.0 REPLACEMENT PARTS AND ACCESSORIES..........................................................27
14.0 SERVICE INFORMATION...........................................................................................27
@Adam Equipment Company 2006
1
@Adam Equipment Company 2006
2

1.0 INTRODUCTION

The CFW series of scales provide an accurate, fast, versatile series of
general purpose weighing scales with counting and check-weighing functions.
There are 2 series of scales- CFW scales are kilogram only scales and
the CFWa scales offer changeable unit from pounds to kilograms. The scales share the same functions but special instructions will be given for the CFWa series to be able to change the weighing units.
There are 4 models in each series with the maximum capacities up to
600 kg /1320 lb.
They all have stainless steel weighing
platforms on a Steel base assembly and a display module mounted on a pillar attached to the base.
All the keypads are sealed and have
colour coded membrane switches.
The displays are large easy to read liquid
crystal type displays (LCD). The LCD’s are supplied with a backlight.
All units include automatic zero tracking, audible alarm for pre-set
weights, automatic tare and an accumulation facility that allows the individual weights to be stored and recalled as an accumulated total.
The scales have an optional bi-directional RS-232 interface for
communicating with a PC or printer.
@Adam Equipment Company 2006
3

2.0 SPECIFICATIONS

CFW SERIES
Model # CFW 60 CFW 150 CFW 300 CFW 600
Maximum Capacity Readability 5 g 10 g 20 g 50g Repeatability (Std Dev) Linearity ± 10 g 20 g 40 g 100g Tare Range -60 kg -150 kg -300 kg -600kg Platform Size 425 mm x 525 mm 600 mm x 800 mm Overall Dimensions (w x d x h) Net Weight 15 kg 45 kg Units of Measure kg, g kg
60 kg 150 kg 300 kg 600kg
5 g 10 g 20 g 50g
425 mm x 700 mm x 950 mm 600 mm x 925 mm x 970 mm
CFWa SERIES
Model # CFW 130a CFW 330a CFW 660a
Maximum Capacity Readability 0.01 lb/
Repeatability (Std Dev) Linearity ± 0.02 lb/
Tare Range -130 lb/ Platform Size 16.7" x 20.7" / Overall
Dimensions (w x d x h) Net Weight 33 lb / 15 kg 99 lb / 45 kg Units of Measure Lb / oz / kg / g
130 lb/
60 kg
5 g
0.01 lb/ 5 g
10 g
-60 kg
/ lb:oz
330 lb/ 150 kg
0.02 lb/ 10 g
0.02 lb/ 10 g
0.04 lb/ 20 g
-330 lb/
-150 kg
425mm x 525mm
425mm x 700mm x 950mm /
16.7" x 27.6" x 37.4"
660 lb/ 300 kg
0.05 lb/ 20 g
0.05 lb/ 20 g
0.10 lb/ 40 g
-660 lb/
-300 kg
600mm x 925mm x 970mm /
Lb / oz / kg / lb:oz
CFW 1320a
1320 lb/
600 kg
0.1 lb/ 50 g
0.1 lb/ 50 g
0.2 lb/
100 g
-1000 lb/
-600kg
23.6" x 31.5" /
600mm x 800mm
23.6" x 36.4" x 38.2"
@Adam Equipment Company 2006
4
Common Specifications
Interface RS-232 bi-directional Interface (Optional) Stabilisation Time 2 seconds typical Operating Temperature 0°C - 40°C
32°F - 104°F
Power supply 9 VDC, 800 mA from external power supply
Internal re-chargeable battery (up to 70 hours operation)
Calibration Automatic External Display 1 x 6 digits LCD digital display Balance Housing Indicator: ABS Plastic
Top pan: Stainless Steel Base: Cast Aluminium for all models except Mild Steel
for CFW 600 (CFW 1320a) Applications General Purpose Floor Weighing Scales Functions Weighing, Parts counting, Memory Accumulation,
Pre-set weighing with alarm
@Adam Equipment Company 2006
5

3.0 INSTALLATION

3.1 LOCATING THE SCALES

The scales should not be placed in a location that
will reduce the accuracy.
Avoid extremes of temperature. Do not place in
direct sunlight or near air conditioning vents.
Avoid unsuitable tables. The table or floor must be
rigid and not vibrate.
Avoid unstable power sources. Do not use near
large users of electricity such as welding equipment or large motors.
Do not place near vibrating machinery.
Avoid high humidity that might cause
condensation. Avoid direct contact with water. Do not spray or immerse the scales in water.
Avoid air movement such as from fans or opening
doors. Do not place near open windows or air­conditioning vents.
Keep the scales clean. Do not stack material on
the scales when they are not in use.

3.2 LIST OF ACCESSORIES

Your packet contains-
9 AC adapter 9 Indicator 9 Metal base 9 Stainless Steel pan 9 Tubular pillar with top flanges 9 Bottom Bracket 9 4 Bolts and 2 set screws 9 Instruction manual
@Adam Equipment Company 2006
6

3.3 SETTING UP THE SCALES

The pillar is attached to the base using a bracket that must be
attached to the base frame first using the 4 bolts supplied. The pillar is secured to the bracket using 2 sets of screws. The cable from the base to the indicator module is run through the tube and taken out through the plastic support at the top. Excess cable can be stored within the tube.
The CFW Series comes with a stainless steel platform packed
separately. Place the platform in the base.
Level the scale by adjusting the four feet. If the scale rocks re-adjust
the feet.
Attach the indicator module to the pillar by sliding it over the bracket
with the flanges engaged in the groves on the base. Attach the cable from the base to the connector on the rear of the indicator.
Attach the power supply module to the connector on the side of the
indicator. Press the [On/Off] key. The software revision number will be displayed followed by a self-test showing all digits before the zero is displayed along with the unit of weight that was selected last.
@Adam Equipment Company 2006
7

4.0 KEY DESCRIPTIONS

[Zero] or
[Tare] or
[Pcs]
[Unit] or [U]
Sets the zero point for all subsequent weighing. The display shows zero.
A secondary function is of "Enter" key used when setting up the value for the Parameters.
Tares the scale. Stores the weight currently on the scale as tare value, subtracts the tare value from the gross weight and shows the results.
A secondary function is of incrementing the active digit when setting a value for Parameters.
Selects parts counting. Used to set the sample quantities while parts counting.
A secondary function is to move the active/flashing digit to the left when setting values for the Parameters.
Selects the weighing unit to be displayed from those which are enabled. See parameter F2 in section 7.
@Adam Equipment Company 2006
8
Loading...