Adam Equipment AELP 1000, AELP 2000, AELP 3000 User Manual

A dam Equipment
AELP
PALLET BEAMS SCALES
(P.N. 4327, Rev. A7, Mar 2016)
© Adam Equi p m ent Company 2016
© Adam Equi p m ent Company 2016
1
CONTENTS
1.0 INTRODUCTION ........................................................................................................... 2
2.0 TECHNICAL SPECIFICATIONS .................................................................................... 3
3.0 UNPACKING THE SCALE ............................................................................................. 4
4.0 SETTING UP THE SCALE ............................................................................................ 4
5.0 KEYPAD AND DISPLAY ................................................................................................ 5
5.1 KEY DESCRIPTION ................................................................................................... 5
5.2 DISPLAY SYMBOLS .................................................................................................. 6
6.0 FUNCTIONS .................................................................................................................. 6
6.1 BL = AUTOMATIC BACKLIGHT CONTROL ................................................................ 7
6.2 AVE = DISPLAY AVERAGING RATE ........................................................................... 8
6.3 FIL = ADC FILTER RATE ............................................................................................. 8
6.4 BOD = BAUD RATE SELECTION .................................................................................. 8
6.5 CONT = CONTINUOUS PRINTING ................................................................................ 9
6.6 PIECE = PARTS COUNTING ........................................................................................ 9
6.7 STEPS = CHECK-WEIGHING FUNCTION (LOW-OK-HIGH) ...................................... 11
6.8 CALIBR = CALIBRATION ROUTINE ........................................................................... 12
6.9 REPL = RESULTS PRINTED AUTOMATICALLY OR MANUALLY .............................. 12
6.10 STAB = PRINT WHEN STABLE OR INSTANTANEOUS .............................................. 13
6.11 AUT = AUTOZERO FUNCTION .................................................................................. 13
6.12 T1 = AUTOMATIC POWER SWITCH OFF ................................................................ 14
6.13 TOP = HOLD MAXIMUM VALUE ................................................................................. 14
6.14 NE = WEIGH IN NEWTONS ....................................................................................... 14
6.15 SUPP = POWER SUPPLY VOLTAGE TO PCB ..................................................................... 15
7.0 COMMUNICATION WITH A COMPUTER/P RINTER .................................................. 15
7.1 PARAMETER ........................................................................................................... 15
7.2 CONNECTION ......................................................................................................... 15
7.3 OUTPUT FORMAT ................................................................................................... 16
7.4 INPUT COMMANDS FORMAT ................................................................................. 16
© Adam Equi p m ent Company 2005
2

1.0 INTRODUCTION

AELP Pallet Beam Scales come with the following standard features:
Lightweight for ease of handling
Supplied with optional indicator if required
Precision load cells for acc ur at e weighing results every time
Handles for portability
Low profile beams to allow easy weighing of pallets
2 beams per set
© Adam Equi p m ent Company 2005
3
Models
Maximum Cap aci ty
Readability
Repeatability Linearity (±)
Internal counting resolution
Tare ra ng e Stabilis at ion time
U nit s of measur e Interface Operating temperature
Power supp l y Calibration
Display
Pan size
Functions
O ther f eatures
AEL P 500
AEL P 200 0
500 kg 2000 kg
200 g
500 g 200 g 500 g 200 g 1000 g
Up to 60,000 divisions
Full
Typically 3 seconds
Kg, g, t or lb
R S- 23 2 b i- dir ec tio na l Inte rface
0 to 4 0° C
10.5 VAC external adapter 6 x AA size Alkaline Dry-cell batteries are suggested
Pu s h b utton cali br at ion
16
mm LCD displays
1250 x 80 x 60 m m
Averaging level, baud rate, print when scale becomes stable or manually, pr int when stable or at any time, auto-zero di sable,
automatic power off, enable maximum value hol d, enable weighing in Newtons
Parts Counting and Check-weighing
N et we i ght
Resolution
200 g
500 g
28 .3 k g

2.0 TECHNICAL SPECIFICATIONS

NEEDS REVISION
© Adam Equi p m ent Company 2005
4

3.0 UNPACKING THE SCALE

Remove the 2 sets of pallet beams using the handles pr ovided.
Take care while removing the beams to avoid banging or injury.
Remove the Indicator and the power supply adapter packed seperately.
Place it on a levelled and firm floor.
Position the beams side by side.

4.0 SETTING UP THE SCALE

Plug in the Indicator into the soc ket provided at the back of the pallet beam (the one having two sockets).
Ensure both the beams are connected via the beam-to-beam cable.
Attach the Power Supply adapter to the Indicator and switch the main supply to ON.
Read this User Manual before starting t he weighing operation.
Place the pallet s on t he beams f or weighing.
© Adam Equi p m ent Company 2005
Loading...