A dam Equipment
AELP
PALLET BEAMS SCALES
(P.N. 4327, Rev. A7, Mar 2016)
© Adam Equi p m ent Company 2016
© Adam Equi p m ent Company 2016
CONTENTS
1.0 INTRODUCTION ........................................................................................................... 2
2.0 TECHNICAL SPECIFICATIONS .................................................................................... 3
3.0 UNPACKING THE SCALE ............................................................................................. 4
4.0 SETTING UP THE SCALE ............................................................................................ 4
5.0 KEYPAD AND DISPLAY ................................................................................................ 5
5.1 KEY DESCRIPTION ................................................................................................... 5
5.2 DISPLAY SYMBOLS .................................................................................................. 6
6.0 FUNCTIONS .................................................................................................................. 6
6.1 BL = AUTOMATIC BACKLIGHT CONTROL ................................................................ 7
6.2 AVE = DISPLAY AVERAGING RATE ........................................................................... 8
6.3 FIL = ADC FILTER RATE ............................................................................................. 8
6.4 BOD = BAUD RATE SELECTION .................................................................................. 8
6.5 CONT = CONTINUOUS PRINTING ................................................................................ 9
6.6 PIECE = PARTS COUNTING ........................................................................................ 9
6.7 STEPS = CHECK-WEIGHING FUNCTION (LOW-OK-HIGH) ...................................... 11
6.8 CALIBR = CALIBRATION ROUTINE ........................................................................... 12
6.9 REPL = RESULTS PRINTED AUTOMATICALLY OR MANUALLY .............................. 12
6.10 STAB = PRINT WHEN STABLE OR INSTANTANEOUS .............................................. 13
6.11 AUT = AUTOZERO FUNCTION .................................................................................. 13
6.12 T1 = AUTOMATIC POWER SWITCH OFF ................................................................ 14
6.13 TOP = HOLD MAXIMUM VALUE ................................................................................. 14
6.14 NE = WEIGH IN NEWTONS ....................................................................................... 14
6.15 SUPP = POWER SUPPLY VOLTAGE TO PCB ..................................................................... 15
7.0 COMMUNICATION WITH A COMPUTER/P RINTER .................................................. 15
7.1 PARAMETER ........................................................................................................... 15
7.2 CONNECTION ......................................................................................................... 15
7.3 OUTPUT FORMAT ................................................................................................... 16
7.4 INPUT COMMANDS FORMAT ................................................................................. 16
© Adam Equi p m ent Company 2005
1.0 INTRODUCTION
AELP Pallet Beam Scales come with the following standard features:
• Lightweight for ease of handling
• Supplied with optional indicator if required
• Precision load cells for acc ur at e weighing results every time
• Handles for portability
• Low profile beams to allow easy weighing of pallets
• 2 beams per set
© Adam Equi p m ent Company 2005
Models
Maximum Cap aci ty
Readability
Repeatability
Linearity (±)
Internal counting resolution
Tare ra ng e
Stabilis at ion time
U nit s of measur e
Interface
Operating temperature
Power supp l y
Calibration
Display
Pan size
Functions
O ther f eatures
AEL P 500
AEL P 200 0
500 kg 2000 kg
200 g
500 g
200 g 500 g
200 g 1000 g
Up to 60,000 divisions
Full
Typically 3 seconds
Kg, g, t or lb
R S- 23 2 b i- dir ec tio na l Inte rface
0 to 4 0° C
10.5 VAC external adapter
6 x AA size Alkaline Dry-cell batteries are suggested
Pu s h b utton cali br at ion
16
mm LCD displays
1250 x 80 x 60 m m
Averaging level, baud rate, print when
scale becomes stable or manually, pr int when
stable or at any time, auto-zero di sable,
automatic power off, enable maximum value
hol d, enable weighing in Newtons
Parts Counting and Check-weighing
N et we i ght
Resolution
200 g
500 g
28 .3 k g
2.0 TECHNICAL SPECIFICATIONS
NEEDS REVISION
© Adam Equi p m ent Company 2005
3.0 UNPACKING THE SCALE
• Remove the 2 sets of pallet beams using the handles pr ovided.
• Take care while removing the beams to avoid banging or injury.
• Remove the Indicator and the power supply adapter packed seperately.
• Place it on a levelled and firm floor.
• Position the beams side by side.
4.0 SETTING UP THE SCALE
• Plug in the Indicator into the soc ket provided at the back of the
pallet beam (the one having two sockets).
• Ensure both the beams are connected via the beam-to-beam
cable.
• Attach the Power Supply adapter to the Indicator and switch the
main supply to ON.
• Read this User Manual before starting t he weighing operation.
• Place the pallet s on t he beams f or weighing.
© Adam Equi p m ent Company 2005