A&D UB-543 Users guide

Wrist Digital Blood Pressure Monitor
Model UB-543
Instruction Manual
Original
Manuel d’instructions
1WMPD4002838D
Manual de Instrucciones
Traducción
Manuale di Istruzioni
Traduzione
使用手冊
翻譯
Contents
Dear Customers ................................................................................................................................................ 2
Preliminary Remarks ......................................................................................................................................... 2
Precautions ....................................................................................................................................................... 2
Parts Identification ............................................................................................................................................. 4
Symbols ............................................................................................................................................................. 5
Using the Monitor .............................................................................................................................................. 7
1. Installing / Changing the Batteries ............................................................................................................ 7
2. Selecting a User ....................................................................................................................................... 8
3. Adjusting the Built-in Clock Before Use .................................................................................................... 8
4. Applying the Cuff ...................................................................................................................................... 9
5. How to Take Proper Measurements ......................................................................................................... 9
6. The C.P.G. Function Switch ..................................................................................................................... 10
7. Selecting the C.P.G. and my C.P.G. .......................................................................................................... 10
8. Measurement ......................................................................................................................................... 11
9. After Measurement ................................................................................................................................. 11
Measurements ................................................................................................................................................. 12
Recalling the Memory Data ............................................................................................................................. 13
Deleting Data Stored in Memory ...................................................................................................................... 14
What is an Irregular Heartbeat? ....................................................................................................................... 15
Pressure Bar Indicator ..................................................................................................................................... 15
WHO Classification Indicator ........................................................................................................................... 15
The C.P.G. Indicator ........................................................................................................................................ 16
About Blood Pressure ...................................................................................................................................... 17
What is Blood Pressure? ............................................................................................................................ 17
What is Hypertension and How is it Controlled? ......................................................................................... 17
Why Measure Blood Pressure at Home? ................................................................................................... 17
WHO Blood Pressure Classification ........................................................................................................... 18
Blood Pressure Variations .......................................................................................................................... 18
Maintenance .................................................................................................................................................... 18
Troubleshooting ............................................................................................................................................... 19
Technical Data................................................................................................................................................. 20
English 1
Dear Customers
Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this device will facilitate your daily blood pressure regimen.
We recommend that you read through this manual carefully before using the device for the first time.
Preliminary Remarks
This device conforms to the European Directive 93/42 EEC for Medical Products. This is made evident by the
mark of conformity. (0123: The reference number to the involved notified body)
The device is designed for use on adults only, not newborns or infants. Environment for use. The device is for use in the home healthcare environment.
This device is designed to measure blood pressure and pulse rate of people for diagnosis.
Precautions
Precision components are used in the construction of this device. Extremes in temperature, humidity, direct
sunlight, shock or dust should be avoided.
Clean the device with a dry, soft cloth or a cloth dampened with water and a neutral detergent. Never use alcohol,
benzene, thinner or other harsh chemicals to clean the device.
Avoid tightly folding the cuff for long periods, as such treatment may shorten the life of the components. The device is not water resistant. Prevent rain, sweat and water from soiling the device.
Measurements may be distorted if the device is used close to televisions, microwave ovens, X-ray or other devices
with strong electrical fields.
Wireless communication devices, such as home networking devices, mobile phones, cordless phones and their base
stations, walkie-talkies can affect this blood pressure monitor.
Therefore, a minimum distance of 3.3 meters (11 feet) should be kept from such devices.
English 2
Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of
according to the applicable local regulations.
When reusing the device, confirm that the device is clean.
Do not modify the device. It may cause accidents or damage to the device. To measure blood pressure, the wrist must be squeezed by the cuff hard enough to temporarily stop blood flow
through the artery. This may cause pain, numbness or a temporary red mark to the wrist. This condition will appear
especially when measurement is repeated successively. Any pain, numbness, or red marks will disappear with time.
Measuring blood pressure too frequently may cause harm due to blood flow interference. Check that the operation
of the device does not result in prolonged impairment of blood circulation, when using the device repeatedly.
If you have had a mastectomy, please consult a doctor before using the device. Do not let children use the device by themselves and do not use the device in a place within the reach of infants.
There are small parts that may cause a choking hazard if swallowed by mistake by infants.
Contraindications
The following are precautions for proper use of the device.
Do not apply the device to a wrist with other medical electrical equipment attached. The equipment may not
function properly. People who have a severe circulatory deficit in the arm must consult a doctor before using the device to avoid
medical problems. Do not self-diagnose the measurement results and start treatment by yourself. Always consult your doctor for evaluation of
the results and treatment. Do not apply the device on a wrist with an unhealed wound. Do not apply the device on an arm receiving an intravenous drip or blood transfusion. It may cause injury or
accidents. Do not use the device where flammable gases such as anesthetic gases are present. It may cause an explosion. Do not use the device in highly concentrated oxygen environments, such as a high-pressure oxygen chamber or an oxygen tent.
It may cause a fire or explosion.
English 3
r
Parts Identification
Display
button ( average, memory and change of preset parameters)
SET button ( user selection
START button
Cuff
WHO classification indicator
and
Pressure bar indicator
Heart mark
User
Battery indicator
and User
MEMORY Average
Battery cove
Display
and clock )
Carrying case
Alkaline batteries (LR03 or AAA)
Systolic pressure
Diastolic pressure
Correct Position Guidance (C.P.G.) indicator
Irregular Heartbeat (I.H.B.) symbol
Pulse rate
Date & clock display
AM / PM mark
English 4
Symbols
Symbols that are printed on the device case
Symbols Function / Meaning
SN Serial number
IP International protection symbol
Standby and Turn the device on Battery installation guide Direct current
Date of manufacture Type BF: Device and cuff are designed to provide special protection against electrical shocks. EC directive medical device label
WEEE label Manufacturer
EU-representative Refer to instruction manual / booklet User selection Keep dry
Symbols that appear on the display
Symbols Function / Meaning / Recommended Action
The heart mark appears while measurement is in progress. It blinks when the pulse is detected.
English 5
Remain as still as possible.
Irregular Heartbeat (I.H.B.) symbol appears when an irregular heartbeat is detected.
It may light when a very slight vibration like shivering or shaking is detected. User 1 and user 2
Symbols
Symbols that appear on the display (continued)
Symbols Function / Meaning Recommended Action
or
Previous measurements stored in MEMORY Average data FULL BATTERY
The battery power indicator during measurement LOW BATTERY
The battery is low when it blinks
Unstable blood pressure due to movement during measurement
The systolic and diastolic values are within 10 mmHg of each other. The pressure value did not increase during inflation. The cuff is not applied correctly.
PUL. DISPLAY ERROR The pulse is not detected correctly.
Blood pressure monitor internal error
Replace all batteries with new ones when the indicator blinks.
Try the measurement again. Remain very still during the measurement.
Fasten the cuff correctly, and try the measurement again.
Remove the batteries and press the
START button, and then install the
batteries again. If the error still appears, contact the dealer.
SYS Systolic blood pressure in mmHg
DIA Diastolic blood pressure in mmHg
PUL Pulse per minute
AM Data taken between 4:00 and 9:59 PM Data taken between 18:00 and 1:59
English 6
Loading...