A&D UB-512 User Manual

Dual MeMory Wrist
Blood Pressure Monitor
Bilingual Instruction Guide – MODEL UB-512
Eng li sh • Es pa ño l
¡IMPORTANTE!
Si Necesita Ayuda Para Operar Su Monitor
¡Nosotros Le Ayudaremos!
Llámenos PRIMERO antes de contactarse con su vendedor
1-888-726-9966 - gratis en EE.UU.
Un representante especializado le asistirá.
IMPORTANT INFORMATION
Please read this important information before using your monitor.
Please remember that only a medical practitioner is qualified to interpret
your blood pressure measurements. Use of this device should not replace regular medical examinations.
Have your physician review your procedure for using this device. He or
she will want to verify blood pressure measurements before prescribing or adjusting medications.
Consult your physician if you have any doubt about your readings. Should
a mechanical problem occur, contact A&D Medical.
Make sure to use the correct cuff size when measuring your blood pressure.
Do not attempt to service, calibrate, or repair this monitor.
Because your UB-512 monitor contains delicate, high-precision parts, avoid
exposing it to extremes in temperature or humidity or to direct sunlight, shock and dust. A&D Medical guarantees the accuracy of this monitor only when it is stored and used within the temperature and humidity ranges noted on page E-17.
Clean the monitor and cuff with a dry, soft cloth or a cloth dampened with
water and a mild detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean monitor or cuff.
Remove and replace batteries if monitor is not used for more than
six months. Alkaline batteries recommended.
PRECAUTIONS
The UB-512 is designed to be used at home, by those who are eighteen (18) years and older, to monitor blood pressure (systolic and diastolic) and pulse rate.
Fast. Easy. Accurate.
Congratulations on purchasing a state-of-the-art LifeSource® blood pressure monitor—one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen.
Physicians agree that daily self-monitoring of blood pressure is an important step individuals can take to maintain cardiovascular health and prevent the serious consequences associated with undetected and untreated hypertension.
A&D Medical has been manufacturing high quality healthcare products for over 20 years. We are committed to providing you and your family with monitoring devices that provide the utmost in accuracy and convenience.
LifeSource - Designed for Life.
LifeSource Health Line (Toll-Free): 1-888-726-9966
?
TABLE OF CONTENTS
WHAT DISPLAY SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . . . . . . .E-2
MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3
HOW UB-512 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4
BEFORE YOU START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4
TAKING YOUR BLOOD PRESSURE . . . . . . . . . . . . . . . . . . . E-5 — E-7
WHAT IS AN IRREGULAR HEARTBEAT . . . . . . . . . . . . . . . . . . . . .E-8
ABOUT CUFF INFLATION METER . . . . . . . . . . . . . . . . . . . . . . . . . .E-8
ABOUT AVERAGE READING . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-9
ABOUT PRESSURE RATING INDICATOR™ . . . . . . . . . . . . . . . . . . .E-9
ABOUT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-10
ABOUT BLOOD PRESSURE . . . . . . . . . . . . . . . . . . . . . . E-11 — E-15
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-16
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-17
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-18
SPANISH INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S-1
In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991
E-1
?
p-3
p-3
1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7
1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7
1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7
1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7
1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7
WHAT DISPLAY SYMBOLS MEAN
Display
Condition/Cause
Symbol
The symbol shown while
measurement is in progress. It blinks while detecting the pulse.
An irregular heartbeat or body movement may have occurred. Refer to page E-8 for more information on irregular heartbeats.
Previous measurement stored in MEMORY.
The battery power indicator
Battery Full
Battery Low
PULSE DISPLAY ERROR
during measurement.
The batteries are low when it blinks.
Unstable blood pressure due to excessive body movement.
The systolic and diastolic values are within 10 mmHg of each other.
The pressure value did not increase during inflation.
The cuff is not fastened correctly.
The pulse is not detected correctly.
Cuff Inflation Meter
Pressure Rating Indicator
Recommended Action
Measurement is in progress, remain as still as possible.
Take measurement again and consult with your physician.
Replace all batteries with new ones when the symbol blinks. Alkaline batteries recommended.
Try the measurement again. Remain very still during the measurement.
Fasten the cuff correctly, and try the measurement again.
Check cuff to ensure fit and fastening is correct, and measure again.
Refasten the cuff and retake measurement.
Try the measurement again. Remain very still during the measurement.
Measurement is in progress, remain as still as possible.
Refer to the section “About
TM
Pressure Rating Indicator™” for further explanation
E-2
?
LifeSource Health Line (Toll-Free): 1-888-726-9966
2
1
SYSTOLIC PRESSURE
MONITOR COMPONENTS
?
BATTERY HOLDER COVER
DIASTOLIC PRESSURE
CUFF INFLATION METER
PRESSURE RATING INDICATOR
AAA BATTERIES
In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991
2
1
CASE
START BUTTONS
PULSE RATE
CUFF
?
E-3
Loading...
+ 16 hidden pages