A&D UA-767NFC User Manual

Digital Blood Pressure Monitor
Model UA-767NFC
Instruction Manual
1WMPD4002380
Contents
Dear Customers.................................................................... 2
Preliminary Remarks ............................................................. 2
Precautions........................................................................... 2
Parts Identification................................................................ 3
Symbols................................................................................ 4
Operation Mode.................................................................... 6
Using the Monitor ................................................................. 7
Installing / Changing the Batteries ................................... 7
Connecting the Air Hose .................................................. 7
Connecting the AC Adapter.............................................. 7
Notes on the Built-in Clock .............................................. 8
Selecting the Clock Mode ................................................. 8
Adjusting the Clock ......................................................... 9
Selecting the Correct Cuff Size ....................................... 10
Applying the Arm Cuff ................................................... 10
How to Take Proper Measurements ................................ 11
Measurement................................................................. 11
After Measurement ........................................................ 11
Measurements .................................................................... 12
Normal Measurement..................................................... 12
Measurement with the Desired Systolic Pressure ............ 13
Notes for Proper Measurement....................................... 13
Near Field Communication (NFC) Function .......................... 14
Memory Data Transmission............................................ 14
Measurement Data Transmission ...................................14
Caution on Using the NFC Function..................................... 15
What is an Irregular Heartbeat............................................. 15
Pressure Bar Indicator ......................................................... 15
About Blood Pressure.......................................................... 15
What is Blood Pressure? ................................................. 15
What is Hypertension and How is it Controlled?.............. 16
Why Measure Blood Pressure at Home?........................... 16
WHO Blood Pressure Classification ................................. 16
Blood Pressure Variations............................................... 16
Troubleshooting ................................................................. 17
Maintenance ....................................................................... 18
Technical Data.................................................................... 18
Dear Customers
Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen.
We recommend that you read through this manual carefully before using the device for the first time.
Preliminary Remarks
This device conforms to the European Directive 93/42 EEC for Medical
Products. This is made evident by the
(0366: The reference number to the involved notified body)
The device is designed for use on adults only, not newborns or infants. Environment for use
The device is intended for indoor use.
mark of conformity.
Precautions
Precision components are used in this device. Extreme temperature,
humidity, direct sunlight, shock or dust should be avoided.
Clean the device and cuff with a dry, soft cloth or a cloth dampened with
water and a neutral detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff.
Avoid tightly folding the cuff or storing the hose tightly twisted for long
periods, as such treatment may shorten the life of the components.
The device and cuff are not water resistant. Prevent rain, sweat and water
from soiling the device and cuff.
Measurements may be affected if the device is used near a television,
microwave oven, cellular telephone, X-ray or other devices that emit electromagnetic waves.
Used equipment, parts and batteries are not treated as ordinary
household waste, and must be disposed of according to the applicable local regulations.
When your arm is squeezed tightly by a cuff, blood collects in the lower
arm and finger tips and your arm may become congested.
2
A
r
A
k
A
Proper Fit Range
rtery Position Mar
Display
Index Mark
Arm Cuff
ir Connector Plug
Battery Compartment
Pressure Bar Indicato
Parts Identification
ir Hose
Display
Air Socket
MEMORY
Clock Button
Button
Battery Cover
Systolic Pressure
Diastolic Pressure
Pulse Rate
DC Jack
Communication Area
START Button
1.5V Batteries
(R6P, LR6 or AA)
Heart Mark
Battery Indicator
3
Clock Display
Clock Mark
I.H.B. Symbol (Irregular heartbeat symbol)
Symbols
Symbols that are printed on the device case
Symbols Function / Meaning Recommended Action
Standby and Turn the device on.
SYS. Systolic blood pressure in mmHg
DIA. Diastolic blood pressure in mmHg
PUL./min. Pulse per minute
SN
2010
Battery installation guide Direct current Serial number Date of manufacture Type BF: Device, cuff and tubing are
designed to provide special protection against electrical shocks.
EC directive medical device label WEEE label Manufacturer EU-representative
Symbols that appear on the display
Symbols Function / Meaning Recommended Action
Appears while measurement is in progress. It blinks when the pulse is detected.
Measurement is in progress. Remain as still as possible.
Irregular Heartbeat symbol (I.H.B.) Appears when an irregular heartbeat is detected. It may light when a very slight vibration like shivering or shaking is detected.
Previous measurements stored in memory.
4
Symbols
Symbols Function / Meaning Recommended Action
Full Battery
Low Battery
The battery power indicator during measurement.
The battery is low when it blinks.
Unstable blood pressure due to movement during measurement.
The systolic and diastolic values are within 10 mmHg of each other.
The pressure value did not increase during the inflation.
The cuff is not applied correctly.
Replace all batteries with new ones when the mark blinks.
Take another measurement. Remain very still during measurement.
Apply the cuff correctly, and take another measurement.
PUL. DISPLAY ERROR
The pulse is not detected correctly.
The communication device may be slanted or placed out of the communication area of the blood pressure
Cannot communicate.
monitor. Hold the communication
symbol of the NFC-enabled communication device close to the communication area of the monitor until “end” appears.
Appears during the clock setting
procedure AM Time between 0:00 and 11:59 PM Time between 12:00 and 23:59