AcuRite 02002 User Manual [en, es]

Please DO NOT return product to the retail store.
For technical assistance and product return information, please call Customer Care: 877-221-1252
Mon. - Fri. 8:00 A.M. to 4:45 P.M. (CST)
www.chaneyinstrument.com
LIMITED ONE YEAR WARRANTY Chaney Instrument Company warrants that all products it manufactures to be of good material and workmanship and to be free of defects if properly installed and operated for a period of one year from date of purchase. REMEDY FOR BREACH OF THIS WARRANTY IS EXPRESSLY LIMITED TO REPAIR OR REPLACEMENT OF DEFECTIVE ITEMS. Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. In all cases, transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which shall have received normal wear and tear, been damaged, tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.
THE ABOVE-DESCRIBED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND ALL OTHER WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. CHANEY EXPRESSLY DISCLAIMS ALL LIBILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES, WHETHER ARISING IN TORT OR BY CONTRACT FROM ANY BREACH OF THIS WARRANTY. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. CHANEY FURTHER DISCLAIMS ALL LIABILITY FROM PERSONAL INJURY RELATING TO ITS PRODUCTS TO THE EXTENT PERMITTED BY LAW. BY ACCEPTANCE OF ANY OF CHANEY’S EQUIPMENT OR PRODUCTS, THE PURCHASER ASSUMES ALL LIABILITY FOR THE CONSEQUENCES ARISING FROM THEIR USE OR MISUSE. NO PERSON, FIRM OR CORPORATION IS AUTHORIZED TO ASSUME FOR CHANEY ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS. FURTHERMORE, NO PERSON, FIRM OR CORPORATION IS AUTHORIZED TO MODIFY OR WAIVE THE TERMS OF THIS PARAGRAPH, AND THE PRECEDING PARAGRAPH, UNLESS DONE IN WRITING AND SIGNED BY A DULY AUTHORIZED AGENT OF CHANEY. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
INST - 02002 052708
Wireless Thermometer
with atomic clock
#02002
Instruction Manual
Package Contents: (1) Main Unit (A) with stand
RF WIR ELESS
A. Main Unit B. Wireless Sensor
Thank You for purchasing this ACURITE® product. Please read this manual in it’s entirety to fully enjoy the benefits and features of this product. Please keep this manual for future reference.
(1) Wireless Sensor (B) (1) Hardware Bag (1) Instruction Manual
What You Need:
• Philips Screwdriver
• (5) AA batteries
-see “Install Batteries”
on page 2
For in-warranty repair, please contact:
Customer Care Department Chaney Instrument Company 965 Wells Street Lake Geneva, WI 53147
Chaney Customer Care 877-221-1252 Mon-Fri 8:00 a.m. to 4:45 p.m. CST
www.chaneyinstrument.com
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1- This device may NOT cause harmful interference, and 2- This device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
CLass B digital dvice, pursuant to Part 15 of the FCC rules. These limits are
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.
Patent numbers: 5,978,738; 6,076,044; 6,597,990
NOTE: A clear film is applied to the LCD at the factory that must be removed prior to using this product. Locate the clear tab and simply peel to remove.
1 • OVERVIEW OF FEATURES
Outdoor Temperature
Outdoor
Temperature
Records
Month & Date
Wireless Sensor Signal Icon
Atomic Clock
Atomic Clock SIgnal Icon
Indoor
Temperature
Setup Buttons
Tabletop Placement Display Stand
- 1 -
About the Atomic Clock
A clock is considered atomic if it has an accuracy of one second in a million years. Consumer clocks are considered atomic if they attain this accuracy by receiving a signal from an atomic clock. In North America, the National Institute of Standards and Technologies operates an atomic clock in Colorado which transmits the time codes via the the radio station WWVB. The signal is transmitted in a very low frequency (60,000 Hz). The Acurite clock you have purchased includes a built-in receiver which picks up the signal from the WWVB station. For the best possible reception, place the main unit with the back side facing Colorado. NOTE: Due to solar radiation in the atmosphere, the atomic clock signal is weaker during the day. Most synchronization with the WWVB atomic clock signal happens at night when there is less interference.
2 • SETUP
Install Batteries
NOTE: Install all batteries in both units within a 6 minute period to ensure proper wireless functionality.
A. Wireless Sensor
1) Remove the 4 battery compartment screws.
2) Remove the battery compartment cover and install 2 fresh “AA” batteries as shown here.
Always install batteries into the wireless sensor FIRST to ensure proper
wireless synchronization with the main unit.
B. Main Unit
Remove the battery compartment cover and install 3 fresh “AA” batteries as shown here.
INSTALL 3 “AA” BATTERIES
REMOVE BATTERY COMPARTMENT COVER
A B C
A B C
REMOVE BATTERY COMPARTMENT COVER
Extended periods of cold temperatures ( below -4ºF / -20ºC )
40
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.
BATTERY SAFETY: Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device.
can cause alkaline batteries to function improperly. This will cause the outdoor wireless sensor to stop transmitting temperature readings. Use lithium batteries in these low temperature conditions to ensure continued operation for wireless sensors placed outdoors.
Main Unit : Basic Setup
After installing batteries, the time zone, time, DST (daylight saving time) and ºF or ºC preferences must be set initially. After the initial manual setting, the atomic clock will maintain it’s accuracy and adjust for DST automatically.
When first entering basic setup mode, the time zone will be flashing. Adjust the time zone using the “ ” or “ ” buttons on the side of the main unit, then press the “SET” button to confirm your time zone selection and move on.
Now select DST (daylight saving time) “on” or “off” by pressing the “ ” or “ ” buttons on the side of the main unit. Press the “SET” button to confirm your DST selection.
Next, adjust the HOUR by pressing the “ ” or “ ” buttons on the back of the main unit. Press the “SET” button to confirm your HOUR selection and to move on to MINUTE setting. Again, adjust the MINUTE by pressing the “ ” or “ ” buttons. You may press and HOLD the “ ” or “ ” to adjust the minutes at a faster rate. Press the “SET” button again to confirm your time setting.
Next, adjust the MONTH and then the DATE in the same manner, using the “ ” and “ ” buttons to adjust and the “SET” button to confirm and move on.
Finally, press the “ ” or “ ” buttons to select between fahrenheit (ºF ) or celsius (ºC) temperature display units.
Press the “SET” button one more time to exit basic setup mode. You may enter basic setup mode again at any time by pressing the “SET” button.
Basic Setup is Now Complete
The wireless sensor will soon send a signal to the main unit and the two units will be synchronized. It may take a few minutes for synchronization to be complete. If both or one of the units appear to be functioning improperly, refer to the troubleshooting section in this manual.
- 3 -- 2 -
3 • PLACEMENT
4 • OPERATION
Now that setup is complete, you must choose a location to place the wireless sensor and the main unit. The wireless sensor MUST be placed less than 100 feet away from the main unit.
This wireless thermometer uses radio frequency for communication, which is susceptible to interference from other electronic devices and large metallic items or thick walls. Always place both units at least 3 feet away from appliances ( TV, microwave, radios, etc. ) or objects ( large metal surfaces, thick stone walls, etc. ) that may interfere with the wireless communication.
TV
3
Placement of Main Unit
Place the main unit in a dry area free of dirt and dust. To help ensure an accurate indoor temperature measurement, be sure to place the main unit out of direct sunlight, and away from any heat sources or vents in your home. For the best possible atomic clock reception, place the main unit with the back side facing Colorado.
There are 2 placement options for the the main unit. You may hang the main unit on a wall using the integrated hang holes on the bottom of the tilting display stand. Alternatively, you may place the main unit on a table top or other flat surface.
After the main unit and the wireless sensor are both powered on and wirelessly synchronized, no further input is required. The atomic clock will automatically re-synchronize occasionally to ensure the clock is accurate.
A
A
A
Wireless Signal Reception Icons
The main unit has signal reception icons in the outdoor temperature display area and near the atomic clock display. If there are a low number of “bars” present, you may experience no temperature display ( “--” ) or inaccuracy. In either case, you may need to relocate one or both of the units. If most or all 4 of the bars are present, wireless reception is good and no action is required. If the atomic clock signal bars are low, the clock may be inaccurate or may not automatically adjust for daylight saving time (DST).
Placement of Sensor
RF WIRELESS
The wireless sensor MUST BE PLACED OUTDOORS to observe outdoor temperatures and relay the outdoor temperature to the main unit display. The wireless sensor must be placed less than 100 feet from the main unit.
The wireless sensor is water resistant and is designed for outdoor use. However, to extend the life of the product, place the wireless sensor in an area protected from direct weather elements. To ensure an accurate outdoor temperature measurement, be sure the wireless sensor is placed out of direct sunlight and away from any heat sources.
- 5 -- 4 -
Loading...
+ 5 hidden pages