Congratulations on your new AcuRite product. To ensure the best
possible product performance, please read this manual in its entirety
and retain it for future reference.
Unpacking Instructions
Remove the protective lm that is applied to the LCD screen prior to using this
product. Locate the tab and peel off to remove.
Package Contents
1. Display unit
2. Outdoor sensor
3. Instruction Manual
PRODUCT MUST BE REGISTERED
IMPORTANT
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
www.AcuRite.com
TO RECEIVE WARRANTY SERVICE
Register a Product
►
Features & Benets
1
2
3
OUTDOOR SENSOR
1. Integrated Hanger
For easy placement.
2. Wireless Signal Indicator
4
Flashes when data is being sent to the
display unit.
3. Battery Compartment
4. Battery Compartment Cover
2
Features & Benets
6
7
8
9
10
11
13
DISPLAY UNIT
6. Hunting or Fishing Activity Meter
Predicts wildlife activity level. Select
hunting, shing, or auto-cycle
between both.
7. Pressure History Graph
Tracks and displays the barometric
pressure history.
8. Barometric Pressure
Arrow icon indicates the direction the
pressure is trending.
9. Intelli-Time® Clock
Sets itself to the correct time and
automatically updates for Daylight
Saving Time.
10. Display Low Battery Indicator
11. Monthly High Temperature Record
12. Current Outdoor Temperature
13. Monthly Low Temperature Record
14
15
16
17
18
19
20
12
21
22
14. Learning Mode Icon
Disappears after weather forecast
self-calibration is complete.
15. 12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls data
from the outdoor sensor to generate
your personal forecast.
16. Moon Phase
17. Intelli-Time® Date
Sets itself to the correct date.
18. Today’s High Temperature Record
19. Wireless Sensor Signal Strength
20. Today’s Low Temperature Record
21. Hunting/Fishing Mode Button
22. Sensor Low Battery Indicator
3
SETUP
Install or Replace Batteries
AcuRite recommends high quality alkaline batteries for the best product
performance. Heavy duty or rechargeable batteries are not recommended.
The outdoor sensor requires lithium batteries in low temperature conditions.
Cold temperatures can cause alkaline batteries to function improperly. Use
lithium batteries in the outdoor sensor for temperatures below -4ºF / -20ºC.
Outdoor Sensor
1. Slide off the battery compartment
cover.
2. Insert 2 x AA batteries into the
battery compartment, as shown.
Follow the polarity (+/-) diagram in
the battery compartment.
3. Replace the battery cover.
Display Unit
1. Slide the stand off of the bottom
of the display, as shown.
2. Slide off the battery compartment
cover.
3. Insert 3 x AA batteries into the
battery compartment, as shown.
Follow the polarity (+/-) diagram in
the battery compartment.
4. Replace the battery cover.
5. Replace the stand.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE
WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used
batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire,
as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge
non-rechargeable batteries. DO NOT short-circuit the supply terminals.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be
4
Intelli-Time® Clock
Intelli-Time products are pre-programmed with the correct time and date.
Intelli-Time technology instructs the time and date to set themselves. All you
need to do is select your Time Zone and Daylight Saving Time preferences. The
clock will then automatically set itself and change for Daylight Saving Time.
Set the Time, Date & Units
Press the “SET” button to enter SET MODE. Once in SET MODE, the
preference you are currently setting will blink on the display.
To adjust the currently selected (ashing) item, press and release the “p” or
“q” buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the “SET” button again to adjust
the next preference. The preference set order is as follows:
TIME ZONE (PST MST CST EST AST HAST AKST)
DST* (Daylight Saving Time ON or OFF)
CLOCK HOUR
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
UNITS: TEMPERATURE (ºF or ºC)
UNITS: PRESSURE (inHg or hPa)
You will automatically exit SET MODE if no buttons are pressed for 30 seconds.
Enter SET MODE at any time by pressing the “SET” button.
*DST is set to ON by default. If you live in an area that observes daylight
saving time, DST should remain ON.
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.