ACT MOTOR ACT DM430 Datasheet

Page 1
ACT Motor GmbH
DM
Stepper Motor Driver
DM430
MicroSteps Setting:200~12800 DC:12~32V
Input voltage 12~32VDC
Output current 0.14A~3A (peak)
Input current <2A
Humidity Not condensation, no water droplets
Using environment -5~ 50 ℃, avoid dust and corrosive gas
Storage environment -50~+80℃
Weight 90g
Control Signal
Symbol Name
ENBL- Offline enable signal input
ENBL+ Offline enable signal input
DIR- Direction signal
Overview
DIR+ Direction signal
Subdivision setting (within 200~12800)
PUL- Pulse signal
Current setting (within 0.1~3A), resolution: 1
PUL+ Pulse signal
Can drive 4-wire, 6-wire and 8-wire motors
With overvoltage, undervoltage, overcurrent, and phase-to-phase short circuit
protection functions
When the offline enable signal is active, the drive fault is reset, any valid
Signal input: single-ended pulse/direction
pulses are disabled, the output power component of the drive is turned
Variable current control greatly reduces motor heating
off, and the motor has no holding torque.
Impulse response frequency up to 500K (factory default 160KHz)
Signal voltage 5~24V compatible
Motor and power
Symbol Name Remark
The connection between the driver and the two-phase hybrid stepping
B- Phase B-
motor is four-wire. The motor windings are connected in parallel and in
B+ Phase B+
series, and the connection method is good. The high-speed performance
A- Phase A-
is good, but the driver current is large (1.73 times the motor winding
A+ Phase A+
current). The drive current is equal to the motor winding current.
GND Input Power- 0V
VCC Input Power + +12~32V
DIP switch setting Subdivision setting
In order to drive stepping motors with different torques, the user can set SW5 SW6 SW7 SW8
description
www.act-motor.com
Page 2
ACT Motor GmbH
the output phase current (effective value) of the driver by the DIP switches default(200) ON ON ON ON
When SW5, SW6, SW7, SW8 are all on, the subdivision of the drive adopts the internal default subdivision number of the drive: the user can set the subdivision number through the PC software ProTuner or STU debugger, the minimum value is 1, the resolution is
1. The maximum
SW1, SW2 ,SW3 and SW4on the driver panel. The output current
corresponding
400 OFF ON ON ON
to each switch position, different models of drivers The corresponding
output
800 ON OFF ON ON
current values are different. See the table below for details. 1600 OFF OFF ON ON
SW1 SW2 SW3 SW4 PEAK RMS 3200 ON ON OFF ON
ON ON ON ON 0.14A 0.1A 3600 OFF ON OFF ON
OFF ON ON ON 0.28A 0.2A 6400 ON OFF OFF ON
ON OFF ON ON 0.42A 0.3A 12800 OFF OFF OFF ON
OFF OFF ON ON 0.60A 0.5A 1000 ON ON ON OFF
ON ON OFF ON 0.84A 0.6A 2000 OFF ON ON OFF
OFF ON OFF ON 0.98A 0.7A 4000 ON OFF ON OFF
ON OFF OFF ON 1.12A 0.8A 5000 OFF OFF ON OFF
OFF OFF OFF ON 1.40A 1.0A 7200 ON ON OFF OFF
ON ON ON OFF 1.68A 1.2A 8000 OFF ON OFF OFF
OFF ON ON OFF 1.82A 1.3A 10000 ON OFF OFF OFF
ON OFF ON OFF 2.10A 1.5A 20000 OFF OFF OFF OFF
OFF OFF ON OFF 2.24A 1.6A
ON ON OFF OFF 2.38A 1.7A Alarm indication
OFF ON OFF OFF 2.52A 1.8A
Serial number Number of flashes Name illustrate
ON OFF OFF OFF 2.80A 2.0A
1 1
Overcurrent or phase-to­phase short circuit fault
OFF OFF OFF OFF 3.00A 2.2A
2 2 Overpressure
RS232 communication USB interface
3 3 Undefined
number
Symbol Name illustrate 4 4 Undefined 1 +5V 5V power supply Only for external STU 2 TXD RS232 Sender 3 RXD RS232 receiver 4 GND GND 0V 5 NC RS232 Sender
Note: The cable connecting M430 and PC, text display or STU servo debugger must be a dedicated cable, please confirm before use to avoid
Drive Dimensional Chart(mm)
www.act-motor.com
Page 3
ACT Motor GmbH
Attention: There must be 20mm space around, can not be placed next to other heating equipment, to avoid dust, oil mist, corrosive gas, humidity and strong vibration.
Adjustment of troubleshooting
Alarm indicator Reasons Measures
LED off turn
Wrong connection for power Check wiring of power
Low-voltages for power Enlarge voltage of power
Motor doesn’t run, without Wrong connection of stepper motor Correct its wiring
www.act-motor.com
Page 4
ACT Motor GmbH
holding torque RESET signal is effective when offline Make RESET ineffective
Motor doesn’t run, but maintains
Without input pulse signal Adjust PMW & signal level
holding torque
Motor runs wrong direction
Wrong wires’ connection Change connection for any of 2 wires
Wrong input direction signal Change direction setting
Motor’s holding torque is
Too small relative to current setting Correct rated current setting
Acceleration is too fast Reduce the acceleration
too small
Motor stalls Rule out mechanical failure
Driver does not match with the motor Change a suitable driver
www.act-motor.com