The illustrations shown in this instruction manual are image drawings and may
differ slightly from the appearance of the actual product.
2
Before Using the Unit
INTRODUCTION
Thank you for purchasing the OMRON®NE-C30 Compact Compressor Nebulizer.
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
Staple your purchase receipt here
This product was developed for the successful treatment of asthma, allergies and
other respiratory disorders. The compressor forces air to the nebulizer. When the air
enters the nebulizer, it converts the prescribed medication into an aerosol of
microscopic droplets that can easily be inhaled.
Your NE-C30 CompAir®Elite comes with the following components:
The following are optional accessories sold separately:
• Adult Mask
• Nosepiece
• Rechargeable Battery
• Battery Charger
The CompAir® Elite is a pr
as instructed by your physician and/or licensed healthcare practitioner.
escription medical device. Operate this device only
SAVE THESE INSTRUCTIONS
3
SAFETY INFORMATION
To assure the correct use of the product basic safety measures should always be
followed including the warnings and cautions listed in this instruction manual.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
WARNING
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury to the user or
patient or damage to the equipment or other property.
OPERATING THE DEVICE
For type, dose, and regime of medication follow the instructions of your physician
or licensed healthcare practitioner.
Pentamidine is not an approved medication for use with this device.
Do not cover the compressor with a blanket, towel, or any other type of cover
during use. This could result in the compressor overheating or malfunctioning.
When using the optional rechargeable battery always fully charge the battery using
the battery charger designed for this device. If the battery is frequently used without
being fully charged, the capacity of the battery will be reduced and the device may
stop during use. In this case, use the AC adapter to continue using the device.
Do not use the device where the device may be exposed to flammable gas or vapors.
Do not use tap or mineral water in the nebulizer for nebulizing purposes.
Clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or masks
before using them for the first time after purchase.
If the device has not been used for a long period of time clean and disinfect the
nebulizer kit, mouthpiece, and optional nosepiece or masks before using them.
Always dispose of any remaining medication in the medication cup after each use.
Use fresh medication each time you use the device.
Do not leave the device or its parts where it will be exposed to extreme temperatures
or changes in humidity, such as leaving the device in a vehicle during warm or hot
months, or where it will be exposed to direct sunlight.
Limit the use of the device to 20 minutes at a time, and wait 40 minutes before
using the device again.
Provide close supervision when this device is used by, on, or near infants, children
or compromised individuals.
4
IMPORTANT SAFETY NOTES
OPERATING THE DEVICE (continued)
Do not insert any object into the compressor.
Make sure the air filter is clean. If the air filter has changed color or has not been
used for 60 days, replace the filter.
Make sure the nebulizer kit is correctly assembled, the air filter is properly installed,
and the air tube is correctly connected to the compressor and the nebulizer kit. Air
may leak from the air tube during use if not securely connected.
Inspect the compressor (main unit) and the nebulizer parts each time before using
the device. Make sure no parts are damaged, the nozzle and air tube are not blocked
and the compressor operates normally.
Do not use the device if the air tube is bent.
Do not block the air filter cover.
Do not alter the baffle, the nozzle in the medication cup or any part of the nebulizer kit.
Do not add more than 7ml of medication to the medication cup.
Do not operate the device at temperatures greater than +104˚F (+40˚C).
Do not tilt the nebulizer kit so the angle of the kit is greater than 45˚. Medication
may flow into the mouth.
Do not shake the nebulizer kit while using the device.
Do not subject the compressor, rechargeable battery, battery charger or any of the
components to strong shocks, such as dropping on the floor.
This device is approved for human use only.
Do not disassemble or attempt to repair the device or components.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to
applicable local regulations. Unlawful disposal may cause environmental pollution.
Use only Omron authorized parts and accessories. Parts and accessories not approved
for use with the device may damage the unit.
Changes or modification not approved by Omron Healthcare will void the user warranty.
e that the air tube is securely attached to the compressor (main unit) and
e sur
Mak
nebulizing parts, and does not come loose. Twist the air tube slightly when inserting it
into the connectors to avoid the tube disconnecting during use.
5
IMPORTANT SAFETY NOTES
RISK OF ELECTRICAL SHOCK
Do not connect the battery connector located on the bottom of the main unit to the
rechargeable battery terminal using wire or other metallic conductors.
Do not use the compressor (main unit), AC adapter, rechargeable battery or battery
charger while they are wet.
Do not plug or unplug the power cord into the electrical outlet with wet hands.
Do not immerse the compressor (main unit) in water or other liquid.
Do not spill water or other liquids on the compressor, AC adapter, rechargeable
battery and battery charger. These parts are not waterproof. If liquid spills on
these parts, immediately unplug the power cord and wipe off the liquid with gauze
or other soft absorbent material.
Do not use or store the device in humid locations, such as a bathroom. Use the
device within the operating temperature and humidity.
Do not place metal objects, such as hair pins, in the carrying bag with device and
the rechargeable battery.
Use only the AC adapter designed by Omron for this device. Use of any other AC
adapter may damage the device.
Do not use a cellular phone near the device. It may result in an operational failure.
Do not overload power outlets. Plug the device into the appropriate voltage outlet.
Do not use extension cords. Plug the power cord directly into the electrical outlet.
Unplug the power cord from the electrical outlet after using the device.
Remove the rechargeable battery and the AC Adaptor from the device after use.
Unplug the power cord from the electrical outlet before cleaning the device.
Completely read all of the instructions included with the optional accessories,
such as the rechargeable battery and battery charger, before using them.
6
IMPORTANT SAFETY NOTES
MAINTENANCE AND STORAGE
Keep the device out of the reach of unsupervised infants and children. The device
may contain small parts that can be swallowed.
Do not leave the cleaning solution in the nebulizer parts. Rinse the nebulizer parts
with clean hot tap water after disinfecting.
Wash the nebulizer parts after each use. Dry the parts immediately after washing.
Do not store the air tube with moisture or medication remaining in the air tube.
This could result in infection as a result of bacteria.
Store the device and the components in a clean, safe location.
Do not carry or leave the nebulizer with medication in the medication cup.
Do not place or attempt to dry the device, components or any of the nebulizer
parts in a microwave oven.
Do not wrap the power cord around the compressor (main unit).
7
Main Unit:
3
5
3
5
Compressor
Power Indicator
Power Switch
Charge
Indicator
Front View
Air Plug
Air Connector
KNOW YOUR UNIT
Nebulizing Kit
Nebulizer Kit
Holder
Air Filter Cover
(*Air Filter Inside)
Air Plug
Back View
Power Connector
Bottom View
Air Tube
Components:
Nebulizer Kit
Nozzle
Cap
Inhalation Air Inlet
Inhalation Top
Baffle
Medication Cup
Air Tube Connector
8
Mouthpiece
AC Adapter
er Plug
w
o
P
Battery Connector
Child Mask
Power Cord
Components:
Compact Compressor Nebulizer
MODEL
NE-C30
INSTRUCTION MANUAL
ENGLISH
3
5
ESPAÑOL
PORTUGUÊS
Caution:
Federal (USA) law restricts this device to sale by or on the
order of a physician or licensed healthcare practitioner
Clean and disinfect the nebulizer kit, mouthpiece, and optional
nosepiece or masks before using them for the first time after purchase.
WARNING
If the device has not been used for a long period of time clean and
disinfect the nebulizer kit, mouthpiece, and optional nosepiece or
masks before using them.
For directions on cleaning and disinfecting refer to page 17 and page 18.
CAUTION
Make sure the air filter is clean. If the air filter has changed color or
has not been used for 60 days, replace the filter.
For directions on changing the air filter refer
to page 20.
1. Insert the power plug on the AC adapter into
the power connector on the back side of the
compressor. Plug the AC adapter into the
electrical outlet.
Power Connector
Power Plug
Power Outlet
WARNING
Do not plug or unplug the power cord into the
electrical outlet with wet hands.
CAUTION
Do not overload power outlets. Plug the device into the
appropriate voltage outlet.
CAUTION
Do not use extension cords. Plug the power cord directly
into the electrical outlet.
2. Lift up the mouthpiece and the cap to remove
them from the nebulizer kit.
3. Rotate the inhalation top counterclockwise (A) and lift
ve the inhalation top from the medication cup.
(B) to r
emo
10
PREPARING THE NEBULIZER FOR USE
max
5
3
max
5
3
4. Lift up the baffle and remove the baffle from the
medication cup.
CAUTION
Do not alter the baffle, the nozzle in the medication cup or
any part of the nebulizer kit.
5. Add the correct amount of prescribed medication to
the medication cup.
WARNING
Pentamidine is not an approved medication for use with this device.
WARNING
For type, dose, and regime of medication follow the instructions of
your physician or licensed healthcare practitioner.
WARNING
Do not spill water or other liquids on the compressor and power cord.
The compressor and power cord are not waterproof. If liquid spills on
these parts, immediately unplug the power cord and wipe off the liquid
with gauze or other soft absorbent material.
WARNING
Do not use tap or mineral water in the nebulizer for nebulizing purposes.
CAUTION
Do not add more than 7ml of medication to the medication cup.
6. Place the baffle back into the medication cup. Make sure
the baffle is correctly positioned over the nozzle in the
medication cup.
7. Place the inhalation top on the medication cup over the baffle. The top
the baf
of
Align the pr
indenta
fle should be centered in the inhalation top.
otrusion on the inhala
tion on the medica
tion cup as illustrated (A).
tion top with the
Turn the inhalation top clockwise until securely closed (B).
11
PREPARING THE NEBULIZER FOR USE
A
B
8. Attach the desired inhalation accessory.
NOTE: Mouthpiece and Nosepiece
Place the cap on the medication cup when using the mouthpiece or
nosepiece. Using the cap with the mouthpiece or the nosepiece will
reduce the amount of medication that is discharged into the air.
USING THE MOUTHPIECE
Place the cap on the medication cup over the
inhalation air inlet (A).
Attach the mouthpiece (B).
USING THE NOSEPIECE
Place the cap on the medication cup over the
inhalation air inlet (A).
Attach the nosepiece (B).
NOTE: Child Mask and Adult Mask
Do not place the cap on the medication cup when using
the Child Mask or the Adult Mask.
USING THE CHILD MASK
Attach the mask to the inhalation top.
USING THE ADULT MASK
Attach the mask to the inhalation top.
12
ATTACHING THE AIR TUBE
1
2
1. Push the Air Plug on one end of the Air Tube onto the Air
Connector on the front side of the compressor (A).
2. Push the Air Plug on the other end of the Air Tube onto the Air
Tube Connector on the bottom of the Nebulizer Kit (B).
NOTE: Keep the nebulizer kit upright when attaching the air tube. Medication
may spill out of the medication cup.
CAUTION
Make sure the nebulizer kit is correctly assembled, the air filter is
properly installed, and the air tube is correctly connected to the
compressor and the nebulizer kit. Air may leak from the air tube
during use if not securely connected.
CAUTION
Do not use the device if the air tube is bent.
CAUTION
Make sure that the air tube is securely attached to the compressor
(main unit) and nebulizing parts, and does not come loose. Twist
the air tube slightly when inserting it into the connectors to avoid
the tube disconnecting during use.
3. Use the Nebulizer Kit Holder as a temporary
holder for the nebulizer kit.
13
USING THE DEVICE
m
ax53
m
ax53
max
53
max
53
WARNING
Do not use the device where the device may be exposed
to flammable gas or vapors.
WARNING
Do not use or store the device in humid locations, such as a bathroom.
Use the device within the operating temperature and humidity.
CAUTION
Provide close supervision when this device is used by, on, or near
infants, children or compromised individuals.
CAUTION
Do not use a cellular phone near the device. It may result
in an operational failure.
CAUTION
Inspect the compressor (main unit) and the nebulizer parts each time
before using the device. Make sure no parts are damaged, the nozzle
and air tube are not blocked and the compressor operates normally.
1. Hold the nebulizer kit as illustrated on the right.
CAUTION
Do not tilt the nebulizer kit so the angle of
the kit is greater than 45˚. Medication may flow
into the mouth.
CAUTION
Do not shake the nebulizer kit while using
the device.
2. Turn the power switch on.
The compressor starts. Nebulization begins
and aerosol is generated.
NOTE: The green light shows that the power is on.
CAUTION
Limit the use of
, and wait 40 minutes before using the
time
vice again.
de
the device to 20 minutes at a
14
45°
USING THE DEVICE
m
a
x53
m
a
x53
ma
x53
ma
x53
max53
max53
Press the power switch again to stop nebulization.
NOTE: The green light goes off.
WARNING
Do not cover the compressor with a blanket, towel, or any other type
of cover during use. This could result in the compressor overheating
or malfunctioning.
CAUTION
Do not block the air filter cover.
3. Inhale medication as instructed by your physician
or licensed healthcare practitioner.
USING THE MOUTHPIECE
Insert the mouthpiece into your mouth. Inhale
medication breathing normally. Exhale normally
through the mouthpiece.
USING THE NOSEPIECE
Inhale the medication through the nosepiece as
illustrated. Exhale through the mouth.
NOTE: Child Mask and Adult Mask
If the amount of aerosol is too much, place the cap
on the medication cup over the inhalation air inlet.
USING THE CHILD MASK or THE ADULT MASK
Place the mask over the nose and mouth. Pull the
elastic strap over the head. Gently pull on the strap to
securely hold the mask over the nose and mouth. Inhale
the medication. Exhale normally through the mask.
Complete the tr
4.
WARNING
For type, dose, and regime of medication follow the instructions
of your physician or licensed healthcare practitioner.
eatment.
15
USING THE DEVICE
5. Press the power switch. The compressor
Power Indicator
turns off and nebulization stops.
6. Disconnect the Air Tube from the Nebulizer
Kit. Hold the Air Plug and gently pull down to disconnect the Air Plug
from the Air Tube Connector on the bottom of the nebulizer kit.
7. Check the Air Tube. No condensation or moisture should remain in
the Air Tube.
WARNING
Do not store the air tube with moisture or medication remaining in
the air tube.This could result in infection as a result of bacteria.
If any condensation or moisture remains in the air tube, remove the moisture
from the air tube. Follow the directions below:
1. Make sure the Air Tube is still connected to the Air Connector
on the front side of the compressor.
2. Press the power switch on. The compressor will start and pump
air through the air tube to expel the moisture.
3. Press the power switch again to turn the compressor off.
8. Disconnect the Air Tube from the compressor. Hold the Air Plug
and gently pull the Air Plug off the Air Connector on the front side
of the compressor.
9. Unplug the device from the electrical outlet.
CAUTION
Unplug the power cord from the
electrical outlet after using the device.
UTION
CA
Remove the rechargeable battery and the
A
C Adaptor from the device after use.
16
max
5
3
Care and Maintenance
3
5
CLEANING AFTER EACH USE
Following the cleaning instructions after each use will prevent any remaining
medication in the bottle from drying resulting in the device not nebulizing
effectively and will help prevent infections.
WARNING
Wash the nebulizer parts after each use. Dry the parts immediately
after washing.
1. Remove the inhalation accessory (mouthpiece, mask, or nosepiece)
from the nebulizer kit.
2. Disconnect the air tubing from the nebulizer.
3. Gently twist the inhalation top counterclockwise and lift to separate the
nebulizer into two sections.
4. Remove the baffle.
5. Discard remaining medication in the medication cup.
WARNING
Always dispose of any remaining medication in the
medication cup after each use. Use fresh medication
each time you use the device.
6. Rinse all the parts of the nebulizer kit and the mouthpiece or nosepiece
with hot tap water. You may also wash these parts in a dishwasher.
Remove the parts after the wash and rinse cycle is completed.
DO NOT wash the mask in a dishwasher.
CAUTION
Place the nebulizer pieces in a basket recommended for dishwasher use.
Place the basket on the top shelf to avoid any damage to the nebulizer kit.
7. Rinse the mask with hot tap water.
8. Hand dry or air dry in a clean environment
using a soft, clean, lint-free cloth.
9. Assemble the nebulizer and store the
ne
bulizer kit in a dry, sealed bag.
UTION
CA
bulizer kit should be replaced every 6 months.
The ne
17
DAILY DISINFECTING
You can disinfect daily by soaking the parts in a vinegar solution or using a
commercially available medical disinfectant. If your physician or respiratory
therapist specifies a different cleaning procedure follow their instructions.
Disinfect the nebulizer kit and the mask, nosepiece or mouthpiece after
the last treatment of the day.
VINEGAR METHOD
1. Make a solution of 1 part white vinegar and 3 parts distilled water.
Make enough solution to submerge the parts.
2. Remove the inhalation accessory (mouthpiece, mask, or nosepiece)
from the nebulizer kit.
3. Disconnect the air tubing from the nebulizer.
4. Gently twist the inhalation top counterclockwise and lift to separate
the nebulizer into two sections.
5. Remove the baffle.
6. Wash all the parts of the nebulizer kit, the mouthpiece, nosepiece or
mask in warm water and a mild detergent. Rinse in hot tap water.
You may also wash the nebulizer kit, mouthpiece or nosepiece in a
dishwasher. DO NOT wash the mask in a dishwasher.
CAUTION
Place the nebulizer pieces in a basket recommended for
dishwasher use. Place the basket on the top shelf to avoid
any damage to the nebulizer kit.
18
DAILY DISINFECTING
7. Submerge the parts in the white vinegar and distilled water solution
for 30 minutes.
8. Remove the parts and discard the solution. Rinse the parts with hot
tap water.
9. Hand dry or air dry in a clean environment using a soft, clean,
lint-free cloth.
10. Assemble the nebulizer and store the nebulizer kit in a dry, sealed bag.
WARNING
Store the device and the components in a clean, safe location.
MEDICAL DISINFECTANT METHOD
Consult your physician or respiratory therapist regarding the use of medical
disinfectant cleaners. Carefully follow the instructions supplied by the
manufacturer of the medical disinfectant.
19
CHANGING THE AIR FILTER
Change the air filter every 60 days even if the air filter does not appear dirty.
If the air filter appears dirty, or if water or medication has spilled on the air
filter, replace with a new air filter immediately.
1. Pull the air filter cover to remove from the
front side of the compressor.
2. Remove the dirty filter with a small
pointed object.
CAUTION
Do not attempt to wash or clean the air filter.
Damp air filters can cause blockages. Do not
substitute cotton or any other material for the air filter.
CAUTION
Wash the air filter cover regularly to prevent any
blockage in the cover. Do not boil. Make sure the
cover is dry before inserting the new air filter.
3. Insert a new air filter into the air filter cover.
CAUTION
Before inserting the new air filter make sure the air
filter is clean and free of dust. Do not operate the device
without the air filter. Use only the Omron air filter designed
for this device.
Put the air filter cover back on the compressor.
4.
20
CARING FOR THE DEVICE
Mild Detergent
To keep your device in the best condition and protect the unit from damage
follow these directions:
CAUTION
Do not subject the compressor, rechargeable battery, battery charger
or any of the components to strong shocks, such as dropping on the floor.
CAUTION
Use only Omron authorized parts and accessories. Parts and accessories
not approved for use with the device may damage the unit.
CLEANING THE COMPRESSOR
Clean the casing of the main unit by using
a soft cloth moistened with water or a mild
detergent. Do not use abrasive cleaners.
Dry the casing immediately using a soft
clean cloth.
WARNING
Do not immerse the compressor (main unit) in water or other liquid.
CAUTION
Unplug the power cord from the electrical outlet before cleaning the device.
CAUTION
Do not insert any object into the compressor.
21
CARING FOR THE DEVICE
STORING THE DEVICE
1. Put the nebulizer kit and the inhalation accessory (mouthpiece,
nosepiece or mask) in a dry, sealed bag. Place the bag in the storage
pocket of the carrying bag.
2. Coil the air tubing and place in the storage pocket.
3. Place the compressor in the carrying bag.
CAUTION
Do not wrap the power cord around the compressor (main unit).
4. Zipper the bag closed.
5. Store the device in a safe, clean location. Do not store the device in
extreme hot or cold temperature, high humidity or in direct sunlight.
WARNING
Do not leave the device or its parts where it will be exposed to
extreme temperatures or changes in humidity, such as leaving the
device in a vehicle during warm or hot months, or where it will
be exposed to direct sunlight.
WARNING
Keep the device out of the reach of unsupervised infants and
children. The device may contain small parts that can be swallowed.
CAUTION
Do not carry or leave the nebulizer with medication in the medication cup.
AUTHORIZED SERVICE
Contact Omron Healthcare customer service for warranty and repair
services. There are no user serviceable parts. Unauthorized service will void
the user warranty.
CAUTION
Do not disassemble or attempt to repair the device or components.
22
TROUBLESHOOTING GUIDE
PROBLEM
No power on unit when
the power switch is on.
No nebulization or low
nebulization rate when
the power is on.
vice is
The de
bnor
a
The de
y loud.
mall
vice is very hot.
CAUSE
The AC power cord is not
plugged into an electrical
outlet.
The rechargeable battery is
not connected correctly,
not sufficiently charged, or
the battery has expired.
No medication in the
medication cup.
Too much or too little
medication in the
medication cup.
The baffle is not placed in
the medication cup or
incorrectly positioned.
The nebulizer kit is not
correctly assembled.
The nozzle is blocked.
The nebulizer kit is tilted
at an incorrect angle.
The air tube is incorrectly
attached.
The air tube is folded
or damaged.
The air tube is blocked.
The air filter is dirty.
er is
The air filter co
ectl
incorr
The compressor
is co
vered.
vice has been used
The de
for longer than 20 minutes.
ttached.
y a
v
SOLUTION
Turn the power switch off.
Plug the power plug into an
electrical outlet. Turn the device
on. Make sure the battery is
correctly connected to the
compressor. Charge the
battery. Replace the battery with
a new one.
Add the correct amount of
prescribed medication to the
medication cup.
Make sure the baffle is correctly
positioned over the nozzle in the
medication cup.
Make sure the nebulizer kit is
correctly assembled and the
inhalation accessory is correctly
attached.
Clean and disinfect the nebulizer
kit to remove the blockage.
Hold the nebulizer kit correctly.
Do not tilt the nebulizer kit so
the angle of the kit is greater
than 45 degrees.
Make sure the air tube is correctly
attached to the compressor and
the nebulizer kit.
Make sure the air tube is not
folded, kinked or bent. Inspect
the air tube for any damage.
Replace the air tube if damaged.
Replace the air filter with a new
clean air filter.
Attach the air filter cover
correctly. Make sure the air filter
cover is not blocked.
Do not cover the compressor
with any type of cover during
use. Turn the device off. Wait 40
minutes before using the device
again.
23
WARRANTY
LIMITED WARRANTIES
Your Omron NE-C30 CompAir®Elite Nebulizer Compressor, excluding the nebulizer kit, inhalation
accessories, air tube and air filters, is warranted to be free from defects in materials and workmanship
appearing within 5 years from the date of purchase, when used in accordance with the instructions
provided with your device. The above warranty extends only to the original retail purchaser.
We will, at our option, repair or replace without charge your Omron Nebulizer Compressor.
Repair or replacement is our only responsibility and your only remedy under the above warranties.
To obtain warranty service contact Omron Healthcare's Customer Service by calling
for the address of the repair location and the return shipping and handling fee. Information for
warranty service is available on our website at www.omronhealthcare.com.
Enclose the Proof of Purchase. Include a letter, with your name, address, phone number, and
description of the specific problem. Pack the product carefully to prevent damage in transit. Because
of possible loss in transit, we recommend insuring the product with return receipt requested.
ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE,
ARE LIMITED TO THE DURATION OF THE APPLICABLE WRITTEN WARRANTY
ABOVE. Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER INCIDENTAL,
CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR DAMAGES.
allow the exclusion or limitation of incidental or consequential damages, so the above exclusions
may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which may vary
from state to state.
FOR CUSTOMER SERVICE (USA and Canada)
Visit our web site at: www.omronhealthcare.com
Call toll free: 1-800-634-4350
LIMITED WARRANTIES (OUTSIDE OF THE USA AND CANADA)
Your Omron NE-C30 CompAir®Elite Nebulizer Compressor, excluding the nebulizer kit,
inhalation accessories, air tube and air filters, is warranted to be free from defects in materials and
workmanship appearing within 5 years from the date of purchase, when used in accordance with
the instructions provided with your device. The above warranty extends only to the original retail
purchaser. Should repair be needed during the warranty period, please contact the authorized
distributor in your country.
The above warranty is complete and exclusive. The warrantor expressly disclaims liability for
incidental, special, or consequential damages of any nature. (Some countries do not allow the
clusion or limita
x
e
apply to you).
Any implied warranties arising by the operation of law shall be limited in duration to the term of
anty. (Some countries do not allow limitations on how long an implied warranty lasts, so
arr
this w
the above limitation may not apply to you).
This warranty gives you specific legal rights and you may have other rights which vary from
country to country
tion of incidental or consequential damages, so the above warranty may not
.
1-800-634-4350
Some states do not
24
FCC STATEMENT
Note:
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)
This product has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. The product generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If the product does cause harmful interference to radio or
television reception, which can be determined by turning the product on and
off, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the product and the receiver.
• Connect the product into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)
This digital apparatus does not exceed the Class B limits for radio noise emissions
from digital apparatus as set out in the interference-causing equipment
standard entitled “Digital Apparatus”, ICES-003 of the Canadian Department
of Communications.
Cet appareil numérique respecte les limites de bruits radioeléctriques applicables
aux appareils numériques de Clase B prescrites dans la norme sur le materiel
brouilleur: “Appareils Numériques”, ICES-003 édictée par le minister
des communications.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
25
SPECIFICATIONS
Model:NE-C30
Type:Compressor nebulizer
Power Supply:12VDC 1A (Compressor)
100V-240VAC 50-60Hz (AC adapter)
Power Consumption:12 watts
Nebulizer Rate:0.35 ml/min (without cap)
Particle Size:*MMD approximately 5 µm (based on EN13544-1)
Medication Cup Capacity:7 ml (cc) max.
Appropriate Medication2 mL - 7 mL (cc)
Quantities:
Operating Temperature/+50°F to +104°F (+10°C to +40°C), 30% to 85% RH
Humidity:
Storage Temperature/–4°F to +140°F (–20°C to +60°C), 10% to 95% RH
Humidity/Air Pressure: 700hPa to 1060 hPa
Weight:Approx. 15.5 oz. (440g) (compressor only)
Dimensions:Approx. 4 7/8" (w)
(124 mm × 52mm × 103mm)
Contents:Compressor, Nebulizer Kit, Air Tube, Air Filter Cover,
Mouthpiece, 5 Replacement Filters, Child Mask, AC
Adapter, Carrying Bag, Instruction Man
English, Spanish and Portuguese, Instructional DVD,
and User Registration Card.
UPC Code:0 73796 45330 5
× 2" (h) × 4 1/8" (d)
ual printed in
*MMD = Mass Median Diameter
ested using malvern laser
NOTES:
T
• Subject to technical modification without prior notice.
• Please note that specifications ma
• Do not use the device where it may be exposed to flammable gas.
• This unit confirms to EMC Standard IEC60601-1-2:2001. However, if it is used together
with other medical devices or electrical equipment, they may influence the operations of
one of devices. Please follow any instructions in the manuals and use all devices correctly.
COMPRESSOR NEBULIZER
With respect to electric shock, fire and
mechanical hazards only in accordance with UL60601-1
y vary with medication type used.
26
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.