Invisia™ Towel Bar
Installation Instructions: TB-16-BN / TB-16-CRP / TB-16-PCW
TB-24-BN / TB-24-CRP / TB-24-PCW
THANK YOU...
Thank you for purchasing the Invisia™ Towel Bar. We are
confident that you will find the unique design and durable
construction of this product to be of great assistance in your
daily routine.
To fully enjoy your Invisia™ Towel Bar, please take a few
moments to read these instructions. You should store these
instructions in a safe place for future reference.
SAFETY CONSIDERATIONS
CAUTION: It is your responsibility to see that your Invisia™
Towel Bar is properly assembled, installed, and cared for.
Failure to follow instructions in this manual could result in
serious injury. Support rails can be slippery when wet - use
this product with caution.
INVISIA™ TOWEL BAR INSTALLATION
The Invisia™ Towel Bar should only be installed in areas where
the mounting surface is structurally sound. Strengthening
modifications may be required (see page 3 for details). Should
not be installed in fiberglass / acrylic shower enclosures with
insufficient stiffness and strength. Should not be installed into
metal studs. If you are not equipped to undertake the outlined
work we recommend that you have your Invisia™ Towel Bar
installed by a qualified contractor. Suggested maximum user
weight of support rail is 500lbs/227kg, however this rating is
conditional upon suitable fasteners and supporting sur face.
FASTENERS: INSTALLATION & MAINTENANCE
The Invisia™ Towel Bar must be secured to the wall with
fasteners appropriate to the structural material. Included are 2
sets of mounting hardware for different wall applications.
Inspect, or have inspected (and tighten if necessary) the
screws on a monthly basis. See Page 3 for structural
reinforcement suggestions. Supplied SnapToggles® can be
used (in conjunction with a wood screw into suitable structure)
as an alternative to structural reinforcement - ONLY if the
walls have not been compromised and are judged to be
suitably structural (1/2" drywall, or tile walls on 1/2" min
cement board).
FULL MOUNTING
STRUCTURE
(RECOMMENDED)
All mount points fasten
into structural wood
(wood studs,
reinforced wood
framing, etc.)
#10 x 2" S/S Screw
and Lock Washer (into
wood)
500lbs load capacity 350lbs load capacity N/A
PARTIAL MOUNTING
STRUCTURE
AVAILABLE
Minimum one (center)
mount point fastens into
structural wood; no
structure available for
other mount points
#10 x 2" S/S Screw and
Lock Washer (into wood)
+ SnapToggles® with
#10 x 2" S/S Bolts
(for areas w/o structure)
NO MOUNTING
STRUCTURE
AVAILABLE
None of the mount
points align with the
available structure
WE DO NOT
RECOMMEND THIS
PRODUCT BE
INSTALLED USING
ONLY SNAP
TOGGLES®.
WARR ANTY
All HealthCraft™ Products are covered by a one year limited
warranty with the exception of hand grips which are subject to
normal wear. Buyer hereby indemnifies, agrees to hold
harmless and defend HealthCraft™ Products Inc. from and
against any and all liabilities, claims, (founded and
unfounded), losses, damages, costs and expenses (including
without limitation consequential damages and reasonable
professional fees) resulting from buyers specification,
application, or improper use of goods described hereon;
buyers omission or neglect.
HealthCraft™ Products Inc. does not assume any liability for
damage resulting from services performed by others or faulty
installation, misuse or misapplication of goods sold by
HealthCraft™ Products Inc.
HealthCraft™ Products Inc. shall not be liable for prospective
profits or special, indirect, or consequential damages, or for
the cost of any corrective work done without HealthCraft™
Products Inc. prior approval. HealthCraft™ Products Inc. total
liability hereunder shall in no event exceed the purchase price
of the goods specified hereon.
TOOLS REQUIRED
• Level • Personal Protective Eyewear
• Hammer • Carbide tip drill suitable for tile
• Stud Finder • Protective blanket
TIPS FOR DRILLING INTO TILE
• Use carbide tipped masonry drill on ceramic, or consider a
diamond tip drill for porcelain tile.
• If possible, drill a smaller pilot hole first.
• Be careful to prevent the drill from moving when you first
start it rotating - use duct tape or a wood guide on the
surface of the tile to hold the drill from walking sideways.
• A variable speed drill on slow is best to start the hole. Do
not apply too much pressure when drilling. Do not use a
hammer drill.
WATERPROOFING
Although mounting hardware includes rubber gasket washer,
we recommend that sealant be applied around the wall
contact points for any products mounted in the shower. If not
properly sealed, there is the potential for water to seep into the
wall. This may cause the wood to rot, thus compromising the
structure the support rail is attached to.
HealthCraft Products Inc., Toll Free 888-619-9992.
2790 Fenton Road, Ottawa, Ontario, Canada, K1T 3T7.
Specifications subject to change without notice. PATENT PENDING.
DC154 REV B Page 1 of 4
HealthCraft Products Inc., Toll Free 888-619-9992.
2790 Fenton Road, Ottawa, Ontario, Canada, K1T 3T7.
Specifications subject to change without notice. PATENT PENDING.
DC154 REV B Page 2 of 4