ACT ARX5002, ARX5001 Datasheet

Aeroflex Laboratories Inc. © 1995
Hz
ARX5001 & ARX5002
www.aeroflex.com
REGULATORSARX LOW NOISE DC VOLTAGE
(Preliminary)
Features
Features
• Low Noise, 20NV/Hz @10KHz, Typical
Low Noise, 20NV/ @10KHz, Typical
• Full MilitaryTemperature Range, Built to MIlitary Standards
• Superior High Frequency Line Transient and Input Ripple Rejection
• Full MilitaryTemperature Range, Built to MIlitary Standards
• Full MilitaryTemperature Range, Built to MIlitary Standards
• State of the Art Power Density, Smallest Possible Surface rea
• State of the Art Power Density, Smallest Possible Surface Area
• Load Current Range up to 2 Amperes
CIRCUIT TECHNOLOGY
• Total Worst Case Line & Load Voltage Regulation, <
+1%
• Internal Short Circuit and Current Fold Back Protection
0.690
0.118
0.820
0.070 TYP
Notes:
1. Dimensions in inches
2. Tolerances are +/-0.005 inches unless otherwise specified
3. Package is a JEDEC standard
4. Case is electrically isolated
0.345
1 3
2
0.200 TYP
0.160 TYP.
0.535
0.800 TYP
PIN # FUNCTION
1 V 2 V 3 GND
0.260
0.040
0.030
0.105+/-.008
IN
OUT
Description
The ARX series of low noise DC voltage regulators is a new line of ultra highly reliable microcircuits designed for military and aerospace applications. These regulators utilize advanced multichip module design techniques to provide state-of-the-art performance features with no sacrifice in reliability.
The ARX series regulators can be used in applications where minimum size and maximum output power is required. These regulators are designed to operate over the full military operating case temperature range of -55°C to +125°C.
Outstanding high frequency ripple rejection, input overshoot rejection and input noise rejection are features of the ARX series that are not available from monolithic regulators.
PHYSICAL DIMENSIONS
(Actual Size)
To provide protection against output overloads, current limiting and reduced current foldback short circuit protection are standard.
Table 1 – Electrical Characteristics
Hz
Part Number
(Nominal Voltage)
Conditions
Parameter
Input Voltage
Output Voltage Maximum load current
Load Current Minimum Input voltage
Line Regulation
Load Regulation
Short Circuit Trip Current Minimum Input voltage
(unless otherwise noted)
TA = -55°C to +125°C
Maximum load current
No load current
Delta input voltage = 3V
Maximum load current
Full load to no load current
ARX5002
( +15V )
ARX5001
( +5V )
Min Nom Max Min Nom Max Units
18 - 23 8 - 15 VDC
- - 30 - - 30 VDC
14.85 15.00 15.15 4.95 5.00 5.05 VDC
- -
-
- -
20 50
1.8
100
2 - 3.5 2 - 3.5
- -
-
1 10
- 35
1.8
50
ADC
mVDC
mVDC
ADC
Short Circuit Foldback Current Minimum Input voltage 0.10 0.20 0.40 0.10 0.20 0.30 ADC
Ripple Rejection 0 <
Output Spot Noise
Notes
: 1. Maximum power dissipation is limited to 10 Watts at 125°C case temperature
f < 150kHz, IL = 900 mA
= + 25 °C, VIN = minimum
T
A
10 kHz, I
= 900 mA
L
40
- -
- -
40
40
- -
- -
30
dB
NV/
2. Custom voltage and short circuit trip current settings are available on special order
Recomended Wiring Diagram
V
IN
C
Ceramic
1 µF
1
ARX5001/
IN
ARX5002
3
GND
2
C
OUT1
Tantalum
5-10 µF
V
out
C
OUT2
Ceramic
0.1 µF
Ordering Information ARX5001 +5 Volts
ARX5002 +15 Volts
Specifications subject to change without notice.
Multichip Modules For The Future
Circuit Technology
35 South Service Road
Plainview N.Y. 11803
Tele: (516) 694-6700 Fax: (516) 694-6715
6/23/95
Loading...