ACR Electronics SAT3 User Manual

OWNER VESSEL RADIO CALL SIGN UIN #
CAUTION: Before proceeding to install, test or use your new ACR
Electronics’ product, please read this Product Support Manual in its entirety.
If you have questions regarding the contents of the manual, please contact our Technical Service Department at ACR Electronics, Inc., Telephone +1 (954) 981- 3333. Please be ready to provide the technician with the page number you wish to discuss. If you have a question that is not covered in the manual, please visit our website and access the Frequently Asked Questions (FAQs) section for further information or call our Technical Service Department. The website address is
www.acrelectronics.com. If in the future you lose this manual, you may
access and print a replacement on the ACR website.
NOTE re: Applicable products
This manual supports all configurations of Satellite3 406™/ RLB-38 beacons. In addition to the part numbers listed on the cover page, other configurations of these products are available, thus you may have purchased a product configuration with a somewhat different part number. As long as the first four digits are the same as one of the two part numbers on the cover, this manual is applicable.
Y1-03-0250 Rev. B 1
PLEASE READ ALL WARNINGS,
CAUTIONS AND NOTES CAREFULLY
Table of Contents
STEP ONE - REGISTERING YOUR BEACON ____________________________ 3
STEP TWO - HOW THE BEACON WORKS _____________________________ 6
STEP THREE - INSTALLING THE BEACON _____________________________ 15
STEP FOUR - MAINTAINING THE BEACON ___________________________ 20
APPENDIX A - USING AND TESTING THE GPS SYSTEMS _________________ 25
APPENDIX B - THE COSPAS-SARSAT SYSTEM _________________________ 27
APPENDIX C - TECHNICAL SPECIFICATIONS __________________________ 28
APPENDIX D - WARRANTY, USEFUL LIFE POLICY, NOTICES ______________ 29
Y1-03-0250 Rev. B 2
STEP ONE - REGISTERING YOUR BEACON
Your unique ID code programmed inside each EPIRB is transmitted to Search and Rescue (SAR). SAR forces use this code to pull up your registration to find out valuable information about who needs help.
YOUR RESCUE WILL
BE DELAYED IF YOUR
BEACON ISN’T PROPERLY
REGISTERED!
1. Why is registration important?
As the owner of this 406 MHz beacon, it is mandatory that you register it with the EPIRB national authority of your country: It is the law.
Please note that all 406 MHz beacons are required to have their registration updated every two years by the owner.
HOW REGISTRATION WORKS: All 406 MHz beacons transmit a Unique Identifier Number (UIN) when
activated. This UIN is programmed into the beacon based on the country in which the beacon is registered, thus authorities are able to determine which country’s database will have your registration information. SAR forces will have information as to who you are as the owner of the beacon, the name and type of vessel that you have, your homeport, and who to contact that might know of your current situation - but only if your beacon has been properly registered. Valuable search and rescue resources are wasted every year responding to false alarms, and registering your beacon helps to resolve false alarms quickly.
Y1-03-0250 Rev. B 3
2. What country should I register in?
Register your beacon with the EPIRB national authority of the country for which the beacon was programmed, typically the country where purchased, regardless of where you do your boating.
The beacon must be reprogrammed if you, as the owner, move or the vessel sails under the flag of a different country than the one for which the beacon was previously programmed. To verify the country for which a beacon is programmed, see the label with the UIN (Unique Identification Number) on the back of the unit. Units that do not have a country specified on the UIN label are programmed for the United States.
3. How do I register?
Registration in the United States The national authority that accepts registrations in the United States is the National Oceanic and Atmospheric Administration (NOAA).
Here are three ways to register:
1. The fastest and easiest way to register is online at
www.beaconregistration.noaa.gov/.
2. Faxing a registration is also acceptable. Fax the registration form to the fax number on the top of the registration form.
NOTE: Do not confuse the registration form with the ACR Electronics warranty card.
3. If online or fax registration is not available, mail the registration form with the pre-addressed, postage paid envelope to:
NOAA SARSAT Beacon Registration NSOF, E/SP3 4231 Suitland Road Suitland, MD 20746
All registration forms will be entered in the 406 MHz beacon registration database within 48 hours of receipt. The information you provide on the registration form is used for rescue purposes only.
A confirmation letter, a copy of the actual registration and a proof-of­registration decal will be mailed to you within two weeks. When you receive these documents, please check the information carefully with the existing label on the unit, and then affix the decal to your beacon in the
area marked “BEACON DECAL HERE.” If you do not receive confirmation
back from NOAA in the expected timeframe, call toll free (888) 212-7283 for assistance.
Y1-03-0250 Rev. B 4
Registration outside of the United States
In countries other than the United States, 406 MHz beacons are registered
with that country’s national authority at the time of purchase. The sales
agent should have assisted you in filling out the forms and sending them to the country’s national authority. Alternatively, many countries allow online registration in the International 406 MHz Beacon Registration Database (IBRD) at www.406registration.com.
To verify that the unit is properly programmed for your country, view the UIN label on the back of the unit. In the event that the beacon is not programmed for your country, the sales agent (if properly equipped) can reprogram the unit for the correct country.
4. Do I need a radio license?
In the United States, you may or may not need to obtain or update a radio station license. Check the FCC’s website at
http://wireless.fcc.gov/services/index.htm?job=licensing&id=ship_stations or
call toll-free (888) 225-5322 (CALLFCC) for the latest information. Outside of the United States, contact your local authority for the
requirements.
Y1-03-0250 Rev. B 5
STEP TWO - HOW THE BEACON WORKS
1. How your beacon brings help
406 MHz beacons are a type of portable emergency equipment that transmits a distress signal to search and rescue (SAR) organizations. The purpose of these beacons is to aid SAR teams in tracking and locating ships or individuals in jeopardy as rapidly as possible.
The 406 MHz frequency is a worldwide dedicated emergency frequency that is detected by a special system of satellites called the Cospas-Sarsat system. This satellite system was established by, and continues to be supported by, its primary benefactors - the USA, Russia, Canada and France. The Cospas-Sarsat system has saved over 23,500 lives - and counting - since its inception. See Appendix G or the Cospas-Sarsat website for more information about the system at www.cospas-sarsat.org.
When a 406 MHz beacon is activated, the digital distress message is sent to Cospas-Sarsat satellites and, in turn, the distress message is relayed to SAR. The distress message contains important information about the beacon and its owner. Additional information about the beacon is accessed by SAR from the beacon registration database. At the same time the 406 MHz signal is activated, a 121.5 MHz signal is turned on. The 121.5 MHz signal is used by SAR to home in on the beacon as they approach it.
The 406 MHz signal is detected by multiple satellites and from that information the location of the beacon can be calculated. This data alone is sufficient for SAR to find persons or ships in distress in a reasonable timeframe. However, as a further enhancement, some beacons have a GPS engine onboard. This feature allows the beacon to acquire current location coordinates from an internal GPS receiver or download coordinates from an external GPS receiver. The coordinates are added to the ID of the unit, which is transmitted with the 406 signal. This enables the SAR authorities to locate the beacon to an accuracy of 110 yards (100 m).
Y1-03-0250 Rev. B 6
2. Anatomy of your beacon
NOTE: When unpacking your beacon, it is recommended that you save the
original packaging for re-use when shipping the beacon for battery replacement in the future.
// Activation switch with Witness Tab
The activation switch embodies a special, patented method of activating a beacon. Refer to a subsequent section of this manual for how to activate the beacon.
// Optional External GPS interface
The external GPS Interface serves as the connection to the ship’s GPS
system. Use of this feature requires the purchase of an Optical GPS interface Cable.
Y1-03-0250 Rev. B 7
Top View
Switch Positions
Strobes
Optional GPS
Interface
Antenna
Green
LED
Red LED
Activation/
Test Switch
OFF/READY
Position
TEST
Position
ON/TRANSMITTING
Position
Y1-03-0250 Rev. B 8
GPS Interface Stowage Port
Category 2 – QuickDraw™ Bracket
Category 1 – SeaShelter3 Bracket
Spring
Release
Knob
HydroFix™
Hydrostatic
Release Unit
(HRU)
Ejector
Spring
Antenna
Hook
Front cover hook (detent)
Optional GPS
Interface
Cable
Antenna Hook
Water Sensor Deactivation Magnet
Release Latch
Y1-03-0250 Rev. B 9
3. Activating your beacon
WARNING: This transmitter is authorized for use only during
situations of grave and imminent danger. Deliberate misuse may incur a severe penalty.
Overview Category I beacons are designed to be automatically deployed and activated in the event of a sinking vessel. The beacon may also be hand held on the deck of vessels, or floated in water and attached to a raft or life vest with the lanyard provided.
Category II beacons are designed to be manually deployed from the bracket.
Two conditions must be met for a Category II beacon to automatically activate:
// It must be out of its bracket // It must be wet
NOTE:
Category I and II beacons can always be manually activated in or out of their bracket.
The beacon and bracket are designed to allow the user to perform periodic testing while the beacon is in its bracket.
Either condition by itself will not automatically activate the beacon.
Y1-03-0250 Rev. B 10
Category I beacons-Automatic deployment and activation
HRU releases the rod separating the front and back cover of bracket at a depth between 4-13 feet.
Ejector Spring launches EPIRB from the bracket allowing it to float freely to the water surface.
If the vessel sinks, the HydroFix™ HRU frees the beacon from the bracket, allowing it to float to the surface. Built-in sensors detect that the beacon is no longer in its bracket and when continuity is created by water between two of the top cap screws, an activation circuit is completed.
NOTE: Transmission of the 121.5 MHz and 406 MHz signals will not occur until 100 seconds after activation.
Y1-03-0250 Rev. B 11
Category I and II Beacons-Manual deployment and activation
Push the main switch up 90 degrees, slide toward antenna and all the way down to activate.
Witness tab will break
once placed in the “ON”
position.
Both Category I and II beacons can be manually deployed by removing the beacon from the bracket.
Once removed, the beacon can be activated by placing it in water OR by lifting the Activation Switch to a vertical position, sliding it toward the antenna and pushing down to the opposite side of the beacon. Activating the beacon in this manner breaks off the Activation Witness Tab and allows the switch to properly seat, showing the “ ▌ “ symbol (ON).
A Category I or II beacon MANUALLY activates with the following sequence:
1.) Remove the beacon from its bracket
2.) Activation method one: Place beacon in water
3.) Activation method two: // Lift the switch to a vertical position // Slide the switch toward the antenna // Push the switch down to the opposite side of the beacon (see
illustration below)
Category I and II Beacons-Manual Activation Without Deployment The beacon can be manually activated while still in its bracket by placing the Activation Switch in the ON position. Activation by this method overrides all sensors and turns the beacon “ON.”
Y1-03-0250 Rev. B 12
TIPS FOR OPTIMUM DEPLOYMENT OF AN ACTIVATED BEACON: When activating and deploying your beacon in an emergency, DO
NOT:
// Hold or clutch the beacon or antenna // Operate the beacon while hand held, if at all possible // Turn the beacon off for any reason, including to save power // Activate the beacon if you have any other means of self rescue // Operate the beacon inside a life raft or under any other canopy or
cover
// Tether the beacon to the bracket or vessel
When activating and deploying your beacon in an emergency, DO:
// Follow the steps to activate the beacon as described on the beacon or
in this manual // Give clear view to the sky for best performance // Take the EPIRB with you if abandoning ship, provided there is time to
get it // Tether beacon, using the lanyard, to the life raft and let the beacon
float (if in a life raft) // Keep EPIRB upright for best signal transmission, either by floating it,
resting it or holding it in this position // Manually activate the beacon if it has not been automatically activated
4. Turning off the beacon
If your beacon was manually activated and you wish to deactivate, return the thumb switch to the “OFF” position. If automatically activated and you wish to deactivate, remove the beacon from the water and dry the unit or place the beacon back into the release bracket. The beacon normally takes up to 12 seconds to deactivate.
If deactivation should fail, remove the four screws holding the unit together and unplug the battery to disable the unit. Return the beacon to ACR Electronics for service.
Y1-03-0250 Rev. B 13
5. False alarms
US Region
Telephone Number
Atlantic Ocean / Gulf of Mexico USCG Atlantic Area Command Center
(757) 398-6390
Pacific Ocean Area / USCG Area Command Center
(510) 437-3700
USCG HQ Command Center
(800) 323-7233
To prevent false alarms, it is important to be aware of how your beacon can be activated. An ACR 406 MHz EPIRB can be activated by two different methods. Whether you have a Category I or Category II, these methods are the same.
When the beacon is out of its bracket and wet, the unit will start
//
transmitting When the switch is moved to the “ON” position, in or out of the
//
bracket, the unit will start transmitting
Precautions to prevent false alarms
Do not mount or transport the beacon within 4.6 ft/1.4 m of a
//
magnetic source. Do not store the beacon outside of its bracket if it can get wet.
//
Do not mount the EPIRB backwards in its bracket (lanyard roll must
//
face in). Do not clean the beacon with a water hose and brush while out of
//
its bracket.
Reporting
Should there be, for any reason, an inadvertent activation or false alarm, it
be reported to the nearest search and rescue authorities. The
must
information that should be reported includes:
The EPIRB 15-digit Unique Identifier Number (UIN)
//
Time and date
//
Duration and cause of activation
//
Location of beacon at the time of activation
//
To report false alarms in the United States,
contact any of the following:
To report false alarms outside of the USA
, contact the national authority
where your beacon is registered.
Y1-03-0250 Rev. B 14
STEP THREE - INSTALLING THE BEACON
Date of Installation Example:
Date of installation of New HRU or First Installation of EPIRB including new HRU: August 1, 2010.
This unit will need to be replaced in
August of 2012. Scratch off “AUG 8” and “2011” on the HRU date calendar
Date of Manufacture Example:
On the bottom of the HRU a date of manufacture is pin stamped: 0808.
This unit will need to be replaced in
August 2012. Scratch off “AUG 8” and “2012” on the HRU date calendar
1. Marking battery and Hydrostatic Release Unit expiration dates
: It is the beacon owner’s responsibility to record the expiration dates
NOTE
for both the beacon battery and the HydroFix™ hydrostatic release unit. This information must appear on the product itself.
The left side of the battery housing indicates the battery expiry date. Space is provided for the beacon owner to mark the date the beacon was placed into service. The beacon should be serviced 5 years from the installation date but no later than the battery expiry date.
The ACR HydroFix™ HRU has an expiration date of 2 years
of installation
first. Upon installing your beacon or new HRU,
new expiration date on the HRU date calendar
or 4 years
from the date manufactured
permanently scratch the
as seen below.
from the date
, whichever comes
2. Mounting location
The selection of a mounting location will vary from vessel to vessel. Beacons should be protected from outside influences while being readily accessible at all times in the event of an emergency.
The location selected must be sufficiently rigid to support the weight of the total installation.
Hazards to avoid when selecting a mounting location:
// Vibration // Exposure to the elements // Possibility of impact from hatches, gear, or personnel // Harmful vapors // Exhaust // Harsh chemicals // Locations that can be obscured by foreign articles on a temporary or
permanent basis.
Y1-03-0250 Rev. B 15
CAUTION: Keep this beacon a safe distance away from all magnetic sources. Magnet safe distance is 4.6 ft or 1.4 m, including the distance from stereo speakers.
CAUTION: Category I brackets must be mounted free from obstruction to allow the beacon to automatically float free from the vessel in case of sinking. The SeaShelter3™ can be mounted on a vertical surface with the beacon antenna pointing skyward or a horizontal surface with the beacon face up. Avoid mounting locations that subject the bracket to breaking waves. Avoid structures like dodgers or cabin tops that could trap the beacon upon deployment.
CAUTION: Category II brackets must be mounted in a protected location that is easily accessible should it be necessary to abandon ship.
The QuickDraw™ can be mounted on a vertical surface with the beacon
antenna pointing skyward or a horizontal surface with the beacon face up. Avoid mounting locations that subject the bracket to breaking waves. Avoid mounting locations that do not provide protection from harmful UV rays of the sun. The bracket must be mounted facing inboard to avoid being lost overboard due to impacts of breaking waves, personnel or loose gear.
Visually inspect the area surrounding the mounting bracket installation site for hidden hazards or obstacles that may have been overlooked during the location selection. If there is any doubt as to the ready accessibility to the beacon at all times or if any condition may appear to be questionable, conduct a complete and thorough investigation before final approval of the installation.
: When selecting the beacon bracket location, be sure to consider the
NOTE
requirement for four screw holes to secure the bracket.
Y1-03-0250 Rev. B 16
3. Category I bracket
The SeaShelter3™ Category I bracket has five pre-drilled screw holes to use for securing the bracket to a flat surface. Remove the SeaShelter
™ lid by
3
turning the spring loaded knob on the lid 1/4 turn counterclockwise and pull. The lid will lift away from the top of the base and disengage at the bottom of the base. The lid is tethered to the base to help prevent loss. Pull the beacon with steady pressure from the bracket. It is not necessary to remove the HydroFix™ Hydrostatic Release Unit (HRU) to mount the bracket using four of the holes. For extreme conditions a fifth hole is available when the HydroFix is removed and the ejector spring is deployed. The bracket can be held in place to mark the placement of the screw holes or you can use the mounting template provided. The use of #10 pan head stainless steel fasteners (minimum of ½” long) and ½” washers (not included) is recommended. Make sure that fasteners will not contact any wires or plumbing before drilling pilot holes.
Y1-03-0250 Rev. B 17
4. Category II bracket
Push to Release
Top in First
Bottom in Second
Category II brackets are designed to hold the beacon securely in place. The beacon must be manually deployed. The bracket can be mounted on a vertical flat surface with beacon antenna up or on a horizontal flat surface facing skyward. This location must be easily accessible in order to manually deploy the beacon or to perform the required maintenance and functionality tests. Typical locations include near the helm station or just inside the companionway door.
The QuickDraw™ Category II bracket has three pre-drilled screw holes to use for securing the bracket to a flat surface. Remove the beacon from the
bracket. To do this while holding the assembly, press the “PUSH” lever to
release the beacon from the bracket. Pull the beacon forward and down to remove. The bracket can be held in place to mark the holes. The use of #8 pan head stainless steel fasteners and washers (not included) is recommended. Be sure to confirm that fasteners will not contact any wires or plumbing before drilling pilot holes.
To reinstall the beacon inside the bracket, place the antenna behind the top notch in the bracket. The yellow lanyard roll faces the bracket and rests in the concave part of the bracket. Snap the beacon into place by pushing firmly at the bottom of the beacon (on the ACR logo) until the snaps engage the bottom of the beacon.
Y1-03-0250 Rev. B 18
5. Installing the Optional optical GPS interface cable
The beacon is fitted with an optical interface to connect with an external Global Positioning System (GPS) receiver that will determine the latitude and longitude of its position.
The black lead wire with white stripes should be connected to the output of the external GPS receiver positive transmitter pin. The black wire should be connected to the negative pin.
If you have a Category I beacon and bracket, the connector is at the end of the black lead wire plugs into the beacon via the bezel on the top of the
beacon. See the location of the GPS interface in previous figures (“Anatomy of your beacon”, page 7 and “Top View”, page 8). It is important to seat the
connector completely in the bezel for an operational connection. If you have a Category II beacon and bracket, your connector has two
extensions on it that must be aligned with the two notches on the Category II beacon bezel. The connector is then gently inserted downward into place and turned 90° to lock the connector into the bezel.
If the external GPS receiver is operational and the connection has been correctly made to the optical interface, the green LED in the optical interface will start flashing at activation.
NOTE:
4800 bps. If you are not sure if your receiver is NMEA 0183 compliant, check the interface settings listed in your GPS manual. To optimize your GPS interface feature, be sure that your GPS receiver is equipped with a NMEA 0183 Version 1.5 or higher with GPGGA sentence enabled.
Consult your GPS receiver manual for the maximum cable length acceptable for an external GPS connection to the beacon. Also see Appendix A for information regarding the use and testing of your GPS system in conjunction with the beacon.
Using the optical interface is not necessary for the beacon to function properly; it will, however, enhance the beacon’s performance.
The baud rate output for your GPS receiver NMEA 0183 should be
Y1-03-0250 Rev. B 19
STEP FOUR - MAINTAINING THE BEACON
1. Safety DOs and DON’Ts
On a routine basis aboard ship, DO NOT:
// Hold or carry the beacon by its antenna // Mount the beacon in its bracket close to large structures or magnetic
areas
// Tie the lanyard to the EPIRB bracket or any other structure // Obscure the beacon by placing objects in front of it
On a routine basis aboard ship, DO:
// Mount the beacon in its bracket in an obvious location, so that all can
see it
// Mount the beacon in its bracket with the rolled lanyard facing inward
(facing the bracket)
// Follow the recommended maintenance schedule // Perform a beacon Self-Test monthly // Follow up with beacon service if Self-Test fails
2. Routine beacon maintenance
At least every ninety days, the float free mounting bracket and beacon should be inspected for deterioration and/or residue buildup that may affect the function of the beacon or automatic release. Part of the visual check includes checking the antenna for tightness. Clean the beacon and the mounting bracket to remove any residue buildups. It is recommended that the beacon and mounting bracket be wiped with a damp cloth.
Carefully inspect the beacon case for any visible cracks. Cracks may admit moisture, which could falsely activate the beacon or otherwise cause a malfunction. Any cracks observed should immediately be referred to ACR Service for evaluation. Call ACR Electronics Technical Service +1 (954) 981-3333.
3. Battery replacement
Battery replacement is due 5 years from date after the beacon placed into service, or by expiry date on the beacon whichever is first. During each inspection, check the time remaining until battery replacement is required. The battery must also be replaced if the beacon has been activated for any use other than the Self-Test.
Y1-03-0250 Rev. B 20
Always refer battery replacement and any other beacon service to a factory authorized Service Center. Find a Center near you at
http://www.acrelectronics.com/brc.htm. Battery replacement includes
servicing the beacon by replacing all o-rings, testing the water seal and the electrical properties and doing a full functional test on the unit.
NOTE:
the beacon except to disable (in case of faulty or accidental activation). Otherwise, always have the beacon serviced.
To avoid possible fire, explosion, leakage or burn hazard, do not open, recharge, disassemble or heat beacon above +70º C (+158º F) or incinerate.
These products contain lithium in the battery. Various beacons may or may not require special shipping instructions due to the lithium batteries and changes in shipping regulations. Shipping of hazardous materials requires special handling and documentation. MSDS sheets, along with shipping information, can be found on our website at
http://www.acrelectronics.com/hazmat/default.htm.
In the case of the RLB-38, the product contains small batteries that are non­hazardous. However, regulations can change. Be advised that it is best to verify the shipping requirements at the time you are preparing to ship the unit.
There are no user serviceable items inside the beacon. Do not open
WARNING: Battery contains lithium
4. Shore based maintenance for SOLAS vessels, (SBM) IMO MSC/Circ. 1039
The Maritime Safety Committee has approved guidelines for shore-based maintenance of satellite beacons, for the purpose of establishing standardized procedures and minimum levels of service for the testing and maintenance of satellite beacons. The first shore based maintenance on all ACR EPIRBs is due at the date of the first battery replacement. Visit ACR’s website at www.acrelectronics.com for organizations that perform shore based maintenance.
5. Annual testing for SOLAS vessels, IMO MSC/Circ. 1040
SOLAS regulation IV/15.9 dictates annual testing of 406 MHz satellite EPIRBs. Testing should be carried out using suitable test equipment capable of performing the relevant measurements. All checks of electrical parameters should be performed in the self-test mode, if possible. These tests can be performed by certified ACR Battery Replacement Centers (BRCs). Visit ACR’s website at www.acrelectronics.com for authorized ACR BRCs.
Y1-03-0250 Rev. B 21
6. Changing ownership or contact information
As the owner of the beacon, it is your responsibility to advise the national authority of any change in the information on the registration form. If you are transferring the beacon to a new owner, you are required to inform the national authority. You can do this by using their online database or by letter, fax or telephone and informing the authority of the name and address of the new owner.
The new owner of the beacon is required to provide the national authority with all of the information requested on the registration form. This obligation transfers to all subsequent owners. Registration forms for the United States are available from NOAA by calling (888) 212-7283 (212-SAVE) or by visiting the ACR website at www.acrelectronics.com. Outside of the United States, the new owner may contact his local authority for the necessary form(s).
7. Lost or stolen EPIRBs If your EPIRB is lost or stolen, do the following immediately:
// Report to your local authorities that the EPIRB has been lost or stolen // Contact NOAA at (888) 212-7283 (212-SAVE), or your national
authority, with the following information:
o Police department name o Police department phone number o Police case number
If your EPIRB were to be activated, the information you provided will be forwarded to the appropriate search and rescue authorities who will ensure that your EPIRB gets back to you. If someone attempts to register an EPIRB reported as stolen, NOAA or your national authority will notify the appropriate police department. Visit www.cospas-sarsat.org for more information.
8. Servicing the SeaShelter3™ and the HydroFix™ HRU
The SeaShelter3™ Category I bracket has two main pieces, the lid and the base. To open the bracket, turn the spring loaded knob counterclockwise 1/4 of a turn and pull. The lid will lift away from the top of the base and disengage from the detent at the bottom of the base. The lid is tethered to the base to help prevent loss.
Brackets are a key part of the overall beacon system. They hold a beacon ready for deployment while preventing false alarms. Category I brackets also require replacement of the Hydrostatic Release Unit every two years.
Y1-03-0250 Rev. B 22
NOTE:
Whenever a beacon is returned for service, it
must be accompanied by the bracket.
To remove the expired HRU
When opening the SeaShelter
™ lid, note that the beacon is installed with
3
the lanyard face in. Pull the beacon with steady pressure from the bracket. Do not get beacon wet while out of bracket. The HRU has a keying feature that locks it to the bracket. If you view the HRU rod as the center of a clock, a properly installed HRU will rest at the 7 o’clock position, as shown in the picture above.
WARNING:
The HRU holds down an ejection spring. The spring must
be held in place during the removal and installation of the HydroFix™ to
prevent injury. Depress the top of the ejection spring. This will relieve pressure on the HRU
and allow it to be rotated counterclockwise to the 5 o’clock position. The HRU is now free to be removed. Slowly relieve pressure from the ejection spring and allow it to deploy.
WARNING:
assembly may cause the bracket to malfunction.
WARNING:
9490) in the SeaShelter
Discard the expired HRU. Failure to replace the entire
Be sure to use only ACR’s HydroFix™ HRU (ACR P/N
™. Use of unauthorized replacement parts will void
3
your warranty and may cause the bracket to malfunction. Check the date of manufacture on the new HRU. Follow the instructions that
accompany the HydroFix™ for marking the next expiry date and for
selecting the correct rod adapter for the SeaShelter3™.
To install the new HRU
Apply pressure to the ejection spring and hold it flat against the bracket.
With your free hand place the new HRU into the key way in the 5 o’clock position and rotate clockwise to the 7 o’clock position. Slowly remove
pressure from the ejection spring. The HRU should now be held in the 7 o’clock position with the pressure on the ejection spring.
Reinstall the beacon with lanyard face in. Beacon should fit snugly in the bracket with the antenna captured by the bracket. Reinstall the lid by seating the bottom of the lid to the detent on the base. Close the upper portion of the lid so the HRU rod lines up with the spring loaded knob. With gentle pressure, hold the lid while you turn the lock counterclockwise until it stops, then clockwise until it stops. This should capture the HRU and snap the lid into a locked position. Confirm that the lid is attached to the bottom of the bracket and the HRU.
Y1-03-0250 Rev. B 23
CAUTION:
EEPROM Connect
Beep, Green LED
Test Stopped,
Red LED
Lock Circuit
Beep, Green LED
Test Stopped,
Red LED
Signal Strength
Beep, Green LED
Test Stopped,
Red LED
Locator Light
Beep, Green LED, Strobe
Test Stopped,
Red LED
Summary
Green LED
Do not force the lid closed. If the lid does not close easily,
check to see that the beacon is properly installed in the bracket and the HydroFix™ is properly seated.
9. Servicing the QuickDraw
To remove a beacon from the Category II bracket, press the “PUSH” lever to release the beacon from the bracket. The beacon will now be able to forward and down out of the bracket.
It is not anticipated that the QuickDraw™ will require servicing other than cleaning or, rarely, replacement.
NOTE: Whenever a beacon is returned for service, it must be accompanied by the bracket.
10. Self-Testing the beacon
The Satellite3 406™ beacon may be self-tested as is warranted, up to a maximum of sixty times in the five-year life of the battery, or once per month for the life of the battery. Self-Tests can be performed randomly, however, ACR recommends that you perform the Self-Test on a once per month schedule. Do not exceed sixty (60) Self-Test cycles limit in the five-year life of the battery, to conserve the battery for emergency use.
The functional Self-Test is initiated by momentarily lifting the Activation Switch to a vertical position and holding it in this position for at least one second and at most four seconds. A beep indicates the initiation of the Self-Test sequence. Self-Test will check battery capacity and perform four functional test sequences as described below.
TEST SUCCESS FAIL
The last green LED indicates a successful test. If any of the individual tests fail during Self-Test, there will be two beeps and a red LED flash at the end of the Self-Test. Self-Test will discontinue at that point.
NOTE:
The “beeps” are a very high-pitched tone that some people may not
be able to hear. You may count the green LED flashes.
Y1-03-0250 Rev. B 24
APPENDIX A - USING AND TESTING THE GPS SYSTEMS
1. How the external GPS interface works
The beacon is fitted with an optical interface to connect with an external Global Positioning System (GPS) receiver that will determine the latitude and longitude of its position. This data is transmitted to the emergency system. When the beacon is coupled to a working external GPS receiver, it immediately begins downloading data. Once valid position data has been obtained, the beacon will attempt to update the positional data every 20 minutes. The Satellite3 406™ will store the last valid positional data for up to 4 hours, if it becomes unable to obtain new updated data. It will update this data if and only if it receives new good positional data from the external GPS receiver.
2. Using the external GPS interface
Once a compatible, operating GPS receiver is connected to the Satellite3 406™, the beacon will store coordinate data for incorporation into the emergency message. The coordinates are transmitted to the satellite when the beacon is activated in an emergency. Coordinate data provides a more accurate location to the Search and Rescue Authority and may lead to a faster rescue. Since the last valid GPS position data may stay in the memory for up to 4 hours, the user should take care to make sure that the GPS position data stored is accurate. This can be accomplished by two methods:
// By always leaving a properly functioning external GPS receiver connected to the beacon before activation, or… // By connecting a properly functioning external GPS receiver with a valid position fix, and allowing sufficient time to acquire valid GPS position data.
3. Testing the external GPS interface
Connect the optical interface plug to the beacon bezel and allow sufficient time for the GPS receiver to acquire valid GPS position data (usually less than 1 minute; but it can take up to 20 minutes). Lift the thumb switch to the vertical (Self-Test) position and release. Your beacon will confirm that it has acquired valid GPS data by flashing an extra green LED at the end of a Self­Test.
4. Updating the external GPS position data
When the beacon is properly connected to a functioning and compatible GPS receiver, GPS position data is automatically updated about every 20 minutes while valid GPS position data is present. The operator can force the acquisition of new GPS position data by initiating a Self-Test with the beacon connected to an external GPS receiver with a valid position fix. This
Y1-03-0250 Rev. B 25
bypasses the normal, programmed, waiting time of 20 minutes for the automatic update of GPS position data.
If no valid GPS position data is available, the beacon will keep the previously stored GPS position data for up to 4 hours. In this case, call ACR Customer Service at +1 (954) 981-3333 for instructions on how to reset the beacon with the default message.
A new beacon is programmed with the GPS position data set to a default. If the beacon should be activated, this default GPS position data indicates to the satellite system that the beacon has no valid GPS position stored in memory. Once a functioning and compatible external GPS receiver is properly connected to the beacon, the default data will be replaced by valid GPS position data, as described in the previous sections.
5. LED indication of GPS fix
When the beacon is activated and valid coordinates are acquired, the data is included in the digital message of the next 406 MHz transmission. The LED blinks green when GPS coordinates are sent.
If a time period of 4 hours passes without the internal GPS receiver being able to update the last good set of navigational coordinates, the message transmitted by the beacon will revert back to default data. At this point the green LED will stop blinking and the red LED will flash. The internal GPS will continue to seek coordinates and when successful the green LED will flash. This new data will be transmitted in the next message burst and the green LED will continue to flash.
6. Compatible GPS receivers
External GPS interface requirements: In order to be compatible with the Satellite3 406™, an external GPS receiver must provide location information according to the following requirements:
// NMEA 0183, Version 1.5 or higher // Baud rate: 4800 // Talker device identifier: GP (GPS Receiver) // Sentence format: GGA (GPS Fix Data)
For more information regarding external GPS device compatibility, please visit the ACR website at www.acrelectronics.com.
Y1-03-0250 Rev. B 26
APPENDIX B - THE COSPAS-SARSAT SYSTEM
1. General overview
EPIRBs transmit to the satellite portion of the Cospas-Sarsat system. Cospas-Sarast
satellites are an international system that utilizes Russian Federation and United States’
low altitude, near-polar orbiting satellites (LEOSAR). These satellites assist in detecting and locating activated 406 MHz satellite beacons.
Cospas-Sarsat satellites receive distress signals from EPIRBs transmitting on the frequency of 406 MHz. The Cospas-Sarsat 406 MHz beacon signal consists of a transmission of non­modulated carriers followed by a digital message format that provides identification data. The 406 MHz system uses satellite-borne equipment to measure and store the Doppler-shifted frequency along with the beacon’s digital data message and time of measurement. This information is transmitted in real time to an earth station called the Local User Terminal (LUT), which may be within the view of the satellite, as well as being stored for later transmission to other LUTs.
The LUT processes the Doppler-shifted signal from the LEOSAR and determines the location of the beacon, then the LUT relays the position of the distress to a Mission Control Center (MCC) where the distress alert and location information is immediately forwarded to an appropriate Rescue Coordination Center (RCC). The RCC dispatches Search and Rescue (SAR) forces.
The addition of the GEOSAR satellite system greatly improves the reaction time for a SAR event. This satellite system has no Doppler capabilities at 406 MHz, but will relay the distress alert to any of the LUT stations. When there is GPS data included in the distress message, SAR authorities instantly know your location to within 110 yards (100 m). This speeds up the reaction time by not having to wait for one of the LEOSAR satellite to pass overhead. Because most of the search and rescue forces presently are not equipped to home in on the 406 MHz Satellite beacons signal, homing must be accomplished at 121.5 MHz.
Once the 406 MHz signal is relayed through the LEOSAR and/or GEOSAR network, SAR forces determine who is closest, and then proceed to the beacon using the 121.5 MHz homing frequency.
2. Global Positioning System (GPS)
The GPS system is a satellite group that enables a GPS receiver to determine its exact position to within 30 m (100 ft.) anywhere on earth. With a minimum of 24 GPS satellites orbiting the earth at an altitude of approximately 11,000 miles they provide users with accurate information on position, velocity, and time anywhere in the
world and in all weather conditions. The GlobalFix™ iPRO stores
adds this data to its distress transmission, allowing search and rescue forces to narrow the search to a very small area, thus minimizing the resources required, and dramatically increasing the effectiveness of the overall operation.
Y1-03-0250 Rev. B 27
APPENDIX C - TECHNICAL SPECIFICATIONS
GENERAL/ ENVIRONMENTAL
Beacon size (without antenna)
17.7 H X 10.67 W X 9.09 D cm (6.97 X 4.2 X 3.58 in)
Beacon weight
581 g (20.49 oz)
Beacon material
High impact UV resistant polymer
Color
ACR-Treuse™ (high visibility yellow)
Waterproof
Tested to 10 min @10 m (33 ft), exceeds RTCM
standard
Buoyant
Yes
Deployment
Category I: Automatic hydrostatic release Category II: Manual
BATTERY
Operational life
48 hours minimum @-20º C (-4º F) (Class 2)
Battery type and replacement interval
LiMnO
2
5 years from date beacon placed in service, or after use in an emergency not to exceed battery
expiry
Operating temperatures Storage temperatures
-20º C to +55º C (-4º F to +131º F) (Class 2)
-30º C to +70º C (-22º F to +158º F) (Class 2)
406 MHz TRANSMITTER
Frequency
406.037 MHz
Power output
5 W
Digital message format
Standard location protocol (for the USA; Beacon can be reprogrammed at a service center to other coded formats, and to national location protocol)
121.5 MHz TRANSMITTER
Frequency
121.5 MHz
Power output
25 mW PEP
Modulation type
AM (3K20A3X)
LED STROBE
Light color
White
Output power
1 cd (effective candela)
Flash rate
20-30/ min
Range
360º visibility
GENERAL
Accessories
SeaShelter3™ Category I Mounting bracket, ACR
P/N 9501
QuickDraw™ Category II Mounting bracket, ACR
P/N 9507
HydroFix™ universal hydrostatic release (HRU)
kit, ACR P/N 9490
Optional External GPS Optical Interface Cable for
Category I Mounting bracket, ACR P/N 9388.1
Optional External GPS Optical Interface Cable for
Category II Mounting bracket, ACR P/N 9388
Approvals
FCC ID #B66ACR-RLB36 COSPAS-SARSAT certificate #189
NOTE: For complete information regarding beacon type approvals, please visit ACR’s
website at www.acrelectronics.com
Y1-03-0250 Rev. B 28
APPENDIX D - WARRANTY, USEFUL LIFE POLICY, NOTICES
1. Limited Warranty
This product is warranted against factory defects in material and workmanship for a period of 1 (one) year* from date of purchase or receipt as a gift. During the warranty period ACR Electronics, Inc. will repair or, at its option, replace the unit at no cost to you for labor, materials and return transportation from ACR. For further assistance, please contact our Technical Service Department at ACR Electronics, Inc., 5757 Ravenswood Road, Fort Lauderdale, FL 33312-6645. Email: service@acrelectronics.com, Fax: +1 (954) 983-5087, Telephone: +1 (954) 981-
3333. This warranty does not apply if the product has been damaged by accident or
misuse, or as a result of service or modification performed by an unauthorized factory. Except as otherwise expressly stated in the previous paragraph, THE COMPANY MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR ANY OTHER MATTER WITH RESPECT TO THIS PRODUCT. The Company shall not be liable for consequential or special damages.
To place the warranty in effect, register online at www.acrelectronics.com or return the attached card within 10 days.
*Five years for the following products: EPIRB, PLB, S-VDR, SSAS.
2. Useful Life Policy
The typical service life of a properly maintained Product is limited to 12 years from date of manufacture. Products that are 12 years and 1 month or older from date of manufacture will not be serviced by ACR or our Battery Replacement Centers. A Product that is 12 or less years old from date of manufacture will be serviced as long as the unit appears fit to be placed back into its final operational cycle. Service includes the replacement of those items that must be replaced at service intervals and the verification that the device appears to be in good mechanical and electrical working condition by an ACR authorized service technician.
3. Notices
ACR Electronics diligently works to provide a high quality Product Support Manual, however, despite best efforts, information is subject to change without notice, and omissions and inaccuracies are possible. ACR cannot accept liability for manual contents. To ensure that you have the most recent version of the Product Support Manual, please visit the ACR website at www.acrelectronics.com.
©2009 by ACR Electronics, Inc., part of Cobham plc. All rights reserved. Reproduction in whole or in part is permitted only with permission of ACR Electronics, Inc.
Ongoing product improvements may change product specifications without notice.
Trademarks or registered trademarks are the property of their respective owners.
Y1-03-0250 Rev. B 29
0735
yy
EC DECLARATION OF CONFORMITY
ACR Electronics hereby declares that the following product is in conformity with Council Directive 96/98/EC of 20 December 1996 on Marine Equipment (MED) last amended by Commission Directive 2009/26/EC of 6 April 2009, and has been type examined as described in this Declaration. In accordance with the Directive, the product will be marked with the MED Mark of Conformity as follows:
Product: 406 MHz (COSPAS-SARSAT) Emergency Position-Indicating Radio Beacon (EPIRB) MED Item A.1/5.6
Notified Body: Bundesamt für Seeschifffahrt und Hydrographie (BSH), Notified Body No. 0735 Bernhard-Nocht-Str. 78, 20359 Hamburg, Germany EC Type Examination (Module B) Certificate No.: BSH/4612/5061677/10 EC Quality System (Module D) Certificate No.: BSH/4613/05102/1251/09
Regulations and IMO Resolution A.662(16) ITU-R M.633-2 (05/00) Standards: IMO Resolution A.694(17) ITU-R M.690-1 (10/95)
Manufacturer: ACR Electronics Inc. European ACR Electronics Inc.
5757 Ravenswood Road Representative: (European Office) Fort Lauderdale, FL 33312 1 Rose Cottages, Pitmore Lane,
Trade Name: Satellite3 406TM Model: RLB-38
IMO Resolution A.696(17) C/S T.001 (Nov. 2007) IMO Resolution A.810(19) C/S T.007 (Nov. 2007) IMO MSC/Circ.862 IEC 61097-2, Ed. 3.0, 2008-01 ETSI EN 300 066 V1.3.1 (2001-01) IEC 60945, 4th Ed., 2002-08, incl. Corr.1, 2008
USA Sway, Lymington, Hampshire SO41 6BX UK
yy = Last two digits of the year in which the mark is affixed
Signed on behalf of ACR Electronics Inc. Signed: ________________________________________ Name: Kerry Greer Date: May 3, 2010
Document RLB-38-002 This Declaration complies withISO/IEC 17050-1:2004
Title: Executive Director - Research & Development
ACR Electronics, Inc. is registered by UL to ISO 9001:2000
Y1-03-0250 Rev. B 30