Acnodes RMC 7152 User Manual

661 Brea Canyon Rd., Suite 3 Walnut, CA 91789 tel: 909.598.7388, fax: 909.598.0218, www.acnodes.com
© Copyright 2009 Acnodes, Inc . All right s reserved. Product descripti on and product specifi cations are subjec t to c hange witho ut notic e. For latest produ ct informat ion , please visi t Acnodes’ web sit e at www.a cnod es.c om.
14” short depth server
1
Installation Guide
RMC 7152: 14” short depth server with two Intel Xeon
processors
© Copyright 2009 Acnodes, Inc . All right s reserv ed. Prod uct descripti on and produ ct speci fi catio ns are subjec t to c hange witho ut notic e. For latest produ ct informat ion , please visi t Acnodes’ web sit e at www.a cnod es.c om.
PC 5150
15-inch touch panel PC
661 Brea Canyon Rd., Suite 3 Walnut, CA 91789 tel: 909.598.7388, fax: 909.598.0218, www.acnodes.com
2
14” short depth server
2.4 Installing the System into a Rack
This section provides information on installing the RMC 7152 into a rack. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the unit into a rack with the rack rails provided with the system. You should also refer to the installation instructions that came with the rack unit you are using.
Basic Installation Procedure
You should have received two rack rail assemblies with the RMC 7152. Each of these assemblies consist of two sections: an inner fixed chassis rail that secures to the unit (A) and an outer fi xed rack rail (B) that secures to the rail brackets. A sliding rail guide sandwiched between the two should remain attached to the fixed rack rail (see Figure 2-1). The A and B rails must be detached from each other to install.
To remove the fixed chassis rail (A), pull it out as far as possible - you should hear a "click" sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Then depress the locking tab to pull the inner rail completely out. Do this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
661 Brea Canyon Rd., Suite 3 Walnut, CA 91789 tel: 909.598.7388, fax: 909.598.0218, www.acnodes.com
© Copyright 2009 Acnodes, Inc . All right s reserved. Product descripti on and product specifi cations are subjec t to c hange witho ut notic e. For latest produ ct informat ion , please visi t Acnodes’ web sit e at www.a cnod es.c om.
14” short depth server
3
Installing the Chassis Rails
Position the fixed chassis rail sections you just removed along the side of the chassis making sure the five screw holes line up. Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis (see Figure
2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
© Copyright 2009 Acnodes, Inc . All right s reserv ed. Prod uct descripti on and produ ct speci fi catio ns are subjec t to c hange witho ut notic e. For latest produ ct informat ion , please visi t Acnodes’ web sit e at www.a cnod es.c om.
PC 5150
15-inch touch panel PC
661 Brea Canyon Rd., Suite 3 Walnut, CA 91789 tel: 909.598.7388, fax: 909.598.0218, www.acnodes.com
4
14” short depth server
Installing the Rack Rails
Determine where you want to place the RMC 7152 in the rack (see Rack and Server Precautions in Section 2-3). Position the fixed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure that both are at the exact same height and with the rail guides facing inward.
Installing the Server Into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the locking tabs "click".
661 Brea Canyon Rd., Suite 3 Walnut, CA 91789 tel: 909.598.7388, fax: 909.598.0218, www.acnodes.com
© Copyright 2009 Acnodes, Inc . All right s reserved. Product descripti on and product specifi cations are subjec t to c hange witho ut notic e. For latest produ ct informat ion , please visi t Acnodes’ web sit e at www.a cnod es.c om.
14” short depth server
5
Installing the Server into a Telco Rack
If you are installing the RMC 7152 into a Telco type rack, follow the direc- tions given on the previous pages for rack installa­tion. The only difference in the installation procedure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accomodate the width of the telco rack.
Loading...