ACME IR-7S, IR-7B, IR-5C, IR-6SD, IR-6BD User guide

...
Technical Specifications
IR-7S/IR-7B/IR-5C
Power AC 120V~60Hz or AC 230/240/250V~50/60Hz Fuse 20mm Glass 10A Fast Blow Lamp MSD 250/2 GY9.5
Dimension
Weight
IR-6SD/IR-6BD
Power AC 120V~60Hz AC 230/240/250V~50/60Hz Fuse 20mm Glass 7A Fast Blow Lamp CDM 150W Dimension 695 x 340 x 250 mm Weight 10.7 kg
IR-6S/IR-6B/IR-5S/IR-5B/IR-4C
Power AC 120V~60Hz AC 230/240/250V~50/60Hz Fuse 20mm Glass 6.3A Fast Blow 20mm Glass 5A Fast Blow Lamp ELC 24V 250W
Dimension
Weight
IS-6S/IS-6B/IS-3/IS-4
Power AC 120V~60Hz AC 230/240/250V~50/60Hz Fuse 20mm Glass 6.3A Fast Blow 20mm Glass 5A Fast Blow Lamp ELC 24V 250W
Dimension
Weight
695 x 340 x 250 mm (IR-7S/IR-7B) 360 x 340 x 250 mm (IR-5C)
15 kg (IR-7S/IR-7B)
9.2kg (IR-5C)
695 x 340 x 250 mm (IR-6S/6B/5S/5B) 360 x 340 x 250 mm (IR-4C)
10.6 kg (IR-6S/IR-6B/IR-5S/IR-5B) 8 kg (IR-4C)
685 x 380 x 200 mm (IS-6S/IS-6B) 375 x 380 x 200 mm (IS-4/IS-3)
9.4 kg (IS-6S/IS-6B)
7.5 kg (IS-4/IS-3)
Широкий ассортимент оборудования ACME
на www.maxlight.ru
Innovation , Quality , Performance
User Guide
Professional Entertainment Technology
.
TABLE OF CONTENTS
1. Safety Instruction
2. Technical Specification
2.1 Inserting/Exchanging rotating gobos
2.2 Beam Angle
3. Lamp
4. How To Set The Unit
4.1 Control Panel
4.2 Main Function
5. How To Control The Unit
5.1 Master/Slave Built-In Preprogrammed Function
5.2 Easy Controller
5.3 iSolution Operation / Universal DMX Controller
5.4 Universal DMX Controller
5.5 DMX512 Configuration
5.6 DMX512 Connection
6. Troubleshooting
7. Fixture Cleaning
7. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in which
the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
џ C lean with soft cloth using normal glass cleaning fluid.
џ A lways dry the parts carefully.
џ C lean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
2F
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
Harmonized Standard
EN60598-1: 2000+ALL:2000+A12:2002
Safety of household and similar electrical appliances
Part 1 : General requirements
6. Troubleshooting
Following are a few common problems that may occur during operation. Here are some
suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connect power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of
the unit or the previous one.
4. Try to use another DMX controller.
5. Check in the DMX cables run near or run alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
C. Some units don’t respond to the easy controller
1. You may have a break in the DMX cabling. Check the LED for the response of the
master/ slave mode signal.
2. Wrong DMX address in the unit. Set the proper address.
D. No response to the sound
1. Make sure the unit that does not receive DMX signal.
2. Check microphone to see if it is good by tapping the microphone
E. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
F. The lamp is cutting out intermittently
1. The lamp is not working well. Check the main voltage either too high or too low.
2. Internal temperature may be too high. Check and if necessary replace the fan on the
head.
1. Safety Instruction
WARNING
¤ Please keep this User Guide for f uture consultation. If you sell the unit t o another
user, be sure t hat t hey also receive this user guide.
¤ Unpack and check carefully there is no transportation damage before using the unit.
¤ Before operating, ensure that t he voltage and frequency of power supply match t he
power requirements of t he unit.
¤ It’s im portant to ground the yellow/green conductor to earth in order to avoid electric
shock.
¤ The unit is for indoor use only. Use only in a dry location.
¤ The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
¤ Disconnect main power before fuse/lamp replacem ent or servicing.
¤ Replace f use/lamp only with t he same t ype. Do not use any other type of lamp.
¤ Make sure there is no flammable materials close to t he unit while operating as it is
3F
fire hazard.
¤ Use safety cable when fixes this unit. Don’t handle the unit by taking its head only,
but always by t aking its base.
¤ Maximum ambient temperature is TA: 40. Don’t operate it where the tem perature
is higher than this.
¤ Unit surface temperature m ay reach up to 85C. Don’t t ouch the housing bare-hand
during its operation. Turn off t he power and allow about 15 minutes for t he unit t o
cool down before replacing bulb or serving as t he unit could be very hot.
¤ In the event of serious operating problem, stop using the unit im mediately. Never try
to repair the unit by yourself. Repairs carried out by unskilled people can lead to
damage or m alfunction. Please contact the nearest authorized technical assistance
center. Always use t he same t ype spare parts.
¤ Don’t connect t he device t o any dimm er pack or power pack.
¤ Do not t ouch any wire during operation as high voltage might be causing electric
shock.
Please read carefully the instruction, which includes important
information about installation, operation and maintenance.
.
Warning
¤ To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
¤ Never touch bulb with bare fingers as it is very hot after using.
¤ Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
¤ Do not start on the unit without bulb enclosure or housing are damaged.
¤ The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
¤ Do not look directly at the light while the bulb is on.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt
any repairs yourself. In the unlikely event your unit may require service, please contact
your nearest dealer.
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is
firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to
which you are attaching the unit is secure and is able to support a weight of 20 kgs for each
unit.
5.5 DMX512 Connection
The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.
1.If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable.
4F
2.At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W
resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the
DMX-output of the last unit.
3.Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the
input of the next unit. The cable can not branched or split to a `Y` cable. DMX512 is a very
high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors
can easily distort the signal and shut down the system.
4.The DMX output and input connectors are pass-through to maintain the DMX circuit, when
power is disconnected to the unit.
5.Each lighting unit needs to have an address set to receive the data sent by the controller.
The address number is between 0-511 (usually 0 & 1 are equal to 1).
6.The end of the DMX512 system should be terminated to reduce signal errors.
7.3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
IS-3
2. Technical Specification
• VoltageAC 120V~60Hz or 230V/240V/250V~50/60Hz
• BulbMSD 250/2 GY9.5 (IR-7S/IR-7B/IR-5C) CDM 150W (IR-6SD/IR-6BD)
ELC 24V 250W (IR-6S/IR-6B /IR-5S/IR-5B/ IR-4C/IS-6S/IS-6B/IS-4/IS-3)
• The unit is DMX512 fixture. It features full DMX512 control. It can also be linked together in
master/slave connection, as many as required in and run by built-in program chase
sequences automatically or by sound activation through an internal microphone to create an
intelligent effect.
• It can be operated by DMX512 control or can be used as an individual unit without a
controller.
• Consistent DMX channel enable iRock, iShow and iMove to be link together.
• Features different preprogrammed chase patterns.
• Please use a 3 pin XLR cable/plug when connecting units together.
• Accurate focusable optics system and ultra smooth stepping motors. Fan cooling.
• Pan : 180 deg. Tilt : 70 deg. (IR-7S/IR-7B/IR-6SD/IR-6BD/IR-6S/IR-6B/IR-5S/IR-5B/
IS-6S/IS-6B)
IR-7S/IR-7B Independent gobo wheel with 7 rotating, replaceable gobos plus open,
5F
including 4 metal, 2 glass and 1 effect gobos with shaking effect, Independent color wheel
with 9 dichroic colors with rainbow effect, and independent shutter & dimmer.
I R-6S/IR-6B Independent gobo wheel with 14 gobos plus open and blackout, including 10
metal, 1 replaceable gobo, 2 glass and 1 effect gobos with shaking effect, Independent
color wheel with 11 dichroic colors with rainbow effect, and independent shutter & dimmer.
(IR-5S/IR-5B without dimmer).
IR-5C Independent gobo wheel with 7 rotating, replaceable gobos plus open, including 1
metal, 2 glass, 1 effect, 1 frost gobos, and 2 color temperature filters (5600k & 3200k) with
shaking effect, Independent color wheel with 9 dichroic colors with rainbow effect, and
independent shutter & dimmer.
I R-4C Independent gobo wheel with 14 gobos plus open and blackout, including 7 metal, 1
replaceable, 1 effect, 1 frost, 2 glass, gobos, and 2 color temperature filters (5600k &
3200k), with shaking effect, Independent color wheel with 11 dichroic colors with rainbow
effect, and independent shutter & dimmer.
IS-6S/IS-6B/IS-4 Professional multi-gobo rotator 14 gobos plus open and blackout, including
10 metal, 1 replaceable gobo, 2 glass and 1 effect gobos, with shaking and shutter effect,
Independent color wheel with 11 dichroic colors with rainbow effect.
I S-3 Professional multi-gobo rotator 14 gobos/colors plus open and blackout, including 10
metal, 1 replaceable gobo, 2 glass and 1 effect gobos, with shaking and shutter effect.
2.1 Inserting/Exchanging rotating gobos
( For IR-7S/IR-7B/ IR-5C only ! )
DANGER!
Install the gobos with the device switched off only.
Unplug from mains before!
Open the cover by loosening the fastening screw at the sides of the cover.
If you wish to use other forms and patterns as the standard-gobos, or if the gobos are to be
exchanged, remove the fixation ring with an appropriate tool. Remove the gobo and insert the
new gobo. Press the fixation-ring together and insert it in the front of the gobo.
IS-6S/IS-6B/IS-4 ( IS-4 is a 4 channel gobo rotator )
6F
CAUTION!
Never unscrew the screws of the rotating gobo as the ball bearing
will otherwise be opened!
IR-6SD/IR-6BD/IR-6S/IR-6B/IR-5S/IR-5BIR-4C ( IR-4C is a 4 channel color changer)
2.2 Beam Angel
7F
3. Lamp
MSD 250/2 GY 9.5 (IR-7S/7B/IR-5C) CDM 150W ( IR-6SD/ IR-6BD ) ELC 24V 250W (IR-6S/IR-6B/IR-5S/IR-5B/ IR-4C/IS-6S/IS-6B/IS-4/IS-3)
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.
Diagram for lamp changing
Because of its high internal pressure, there might be a
risk t hat t he Discharge lamp would explode during
operation. The lam p emits intense UV radiation which
is harmful to the eyes and skin. The high luminance of
the arc can cause severe damage to the retina if looks
directly at t he lamp.
1. Always switch off the main supply and never handle
the lamp or lum inaries when is hot.
2. Do not t ouch t he bulb with bare hands. If t his
happens, clean the lam p with denatured alcohol and
wipe it with a lint f ree cloth before installation.
3. The lamp generates UV radiation. Never operate the
lamp without appropriate shielding.
4. When burning, the lamp operates at high pressure and
IR-7S/7B/5C ( IR-5C is a 5 channel color changer )
MSD 250/2
CDM 150W
8F
there is a slight risk of arc tube rupture. The risk
increases with age, temperature and improper
handling of the lamp. Do not use the lamp any
longer than its specified life.
Make sure the lamp is located in the center of the
reflector for the best spot.
ELC 24V 250W
ELC 24V 250W
65. 4 DMX512 Configuration
Model CH1 CH2 CH3 CH4 CH5 CH6 CH7
IR-7S Pan Tilt
IR-7B Pan
IR-6SD/6S Pan Tilt
IR-6BD/6B Pan
IR-5S Pan Tilt
IR-5B Pan
IR-5C
IR-4C
IS-6S Pan Tilt
IS-6B Pan
IS-4
IS-3
Shutter /Shaking
Shutter /Shaking
Shutter /Shaking
Shutter /Shaking
Barrel Rotation
Barrel Rotation
Barrel Rotation
Gobo Color
Gobo Color
Barrel Rotation
Gobo Color Reflector
Gobo /Color
Shutter /Shaking
Shutter /Shaking
Shutter /Shaking
Shutter /Shaking
Shutter /Shaking
Shutter /Shaking
Shutter /Shaking
Shutter /Shaking
No Function
Gobo Color
Gobo Color
Gobo Color
Gobo Color
Gobo Color
Gobo Color
Gobo Rotation
No Function
Gobo Color Reflector
Gobo Color Reflector
Reflector
Dimmer
Dimmer
Gobo Rotation
Gobo Rotation
No Function
No Function
Dimmer
Dimmer
Dimmer
Dimmer
4. How To Set The Unit
4.1 Control Panel
Display
To show the various menu and the selected functions.
LED
DMX On DMX input present MASTER On Master Mode
9F
SLAVE On Slave Mode SOUND Flashing Sound activation
Button
MENU to select the programming functions DOWN to go backward in the selected functions UP to go forward in the selected functions ENTER to confirm the selected functions
Remote controller input
By connect to the 1/4” microphone jack to control the unit for Stand by, Function and Mode.
Sensitivity
To adjust the sound sensitivity.
Microphone
To receives audio signal for sound activation.
DMX input/output
For DMX512 link, use 3-pin XLR plug cable to link the unit together.
4.2 Main Function
To select any of the given functions, press the MENU button up to when the required one is
showing on the display. Select the function by ENTER button and the display will blink. Use
DOWN and UP button to change the mode. Once the required mode has been selected,
press the ENTER button to setup or it will automatically return to the main functions without
any change after idling 8 seconds. To go back to the functions without any change press the
MENU button. The main functions are showing below:
DMX512 Address Setting
Slave mode " Normal " Slave mode " 2 Light Show " Slave mode " 3 Light Show "
Slave mode " 4 Light Show " Blackout Mode " Yes Blackout " Blackout Mode " No Blackout " Normal Color Split Color Pan Normal
MENU
and
DMX512 Address Setting
Press the MENU button up to when the is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to change the DMX512 address.
Once the address has been selected, press the ENTER button to setup or automatically
return to the main functions without any change after 8 seconds. To go back to the functions
without any change press the MENU button again.
Slave Mode
Pan Inversion Tilt / Barrel Normal Tilt / Barrel Inversion Dimmer Normal
Dimmer Inversion
LED on LED off Display Normal Display Inversion
Focus Adjust
Self-Test
Fixture Hours
Reset
only for color-change
5.3.1 iSolution Operation
¤ Consistent DMX configuration enable iRock and iShow to be linked together and
controlled at the same time.
¤ DMX address can be set remotely by iLead controller ( please refer to the user manual
of iLead controller ). No need to calculate the DMX channels of each fixture in the chain.
¤ Automatic switching between DMX function and built-in stand alone programs.
5.3.2 DMX Controller
An universal DMX controller to control the units, you have to set DMX address from 1 to 512
channel so that the units can receive DMX signal.
Press the MENU button up to when the is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
Once the address has been selected, press and keep ENTER button pressed up to when the
display stops blinking or storing automatically 8 seconds later. To go back to the functions
without any change press the MENU button again.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
DMX address can be set remotely by IL-0824 controller. No need to calculate the DMX
channels of each fixture in the chain.
10F
( Following DMX address setting is based on that all the lighting fixtures are linked together
controlled by the 8-channel iLead IL-0824 controller. )
IR-7S/IR-7B/IR-6S/IR-6B/IR-6SD/IR-6BD/IR-5S/IR-5B/IS-6S/IS-6B:
IR-5C/IR-4C/IS-4/IS-3:
5.2 Easy Controller
The easy remote control is used only in master/slave mode. By
connecting to the 1/4” microphone jack of the first unit, you will find
that the remote control on the first unit will control all the other units
as below.
Built-in lighting shows triggered by Easy Controller:
Stand by Blackout t he unit
IR-7S IR-7B
Function Strobe
IR-6SD IR-6BD IR-6S IR-6B IR-5S
Mode Sound 1
IR-5B
Stand by Blackout t he unit
IR-5C IR-4C
Function Strobe
Mode Sound 1
Stand by Blackout t he unit
IS-6S IS-6B
Function Strobe
Mode Sound 1
Stand by Blackout t he unit
IS-4
Function Strobe
Mode Sound
Stand by Blackout t he unit
IS-3
Function Strobe
Mode Sound
1.Gobo/Color sync. strobe
2.Sync. st robe
3.Two-light strobe
(LED off )
1.Gobo/Color sync. strobe
2.Sync. st robe
3.Two-light strobe
(LED off )
1.Gobo/Color sync. strobe
2.Sync. st robe
3.Two-light strobe
(LED off )
1.Gobo/Color sync. strobe
2.Sync. st robe
3.Two-light strobe
(LED off )
1.Gobo/Color sync. strobe
2.Sync. st robe
3.Two-light strobe
(LED off )
X/Y moving pattern
X/Y moving pattern selection ( 12 patterns )
Sound 2 (LED normal blinking)
Chase pattern s election ( 6 patterns )
Sound 2 (LED normal blinking)
X/Y moving pattern selection ( 12 patterns )
Sound 2 (LED normal blinking)
Gobo/Color selection
1.Hold on for gobo change.
2.Press shortly for color change.
Slow (LED on)
Gobo/Color selection
Slow (LED on)
Color/Gobo selection
1. Hold on for gobo change.
2. Press shortly for color
Slow/Sound 3 (LED on)
Color/Gobo selection
1. Hold on for gobo change.
2. Press shortly for color
Slow (LED on)
Color/Gobo selection
1. Hold on for gobo change.
2. Press shortly for color
Slow/Sound 3 (LED on)
change.
change.
change.
X/Y moving setting
1.Pan position
2.Tilt position
3.Dimmer
Position/ Latch (LED fast blinking )
Dimmer setting
Latch (LED fast blinking )
X/Y moving setting
1.Pan position
2.Tilt position
Position/ Latch (LED fast blinking )
Press the MENU button up to when the is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the (normal) or
(2 light show) mode or (3 light show) mode or (4 light show). Once
the mode has been selected, press the ENTER button to setup or automatically return to the
main functions without any change after 8 seconds. To go back to the functions without any
change press the MENU button again.
Blackout Mode
Press the MENU button up to when the is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the (yes
blackout) or (no blackout) mode. Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after
8 seconds. To go back to the functions without any change press the MENU button again.
Color Mode
Press the MENU button up to when the is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the (normal) or
11F
(split color) mode. Once the mode has been selected, press the ENTER button to
setup or automatically return to the main functions without any change after 8 seconds. To go
back to the functions without any change press the MENU button again.
Pan I nversion
Press the MENU button up to when the is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the (normal) or
(pan inversion) mode. Once the mode has been selected, press the ENTER button to
setup or automatically return to the main functions without any change after 8 seconds. To go
back to the functions without any change press the MENU button again.
Tilt I nversion Barrel Rotation Inversion
Press the MENU button up to when the ( ) is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to select the
(normal) or (tilt/barrel rotation inversion) mode. Once the mode has been
selected, press the ENTER button to setup or automatically return to the main functions
without any change after 8 seconds. To go back to the functions without any change press the
MENU button again.
Dimmer Inversion
Fixture Hours
Press the MENU button up to when t he is shown on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(normal) or (dim mer inversion) mode. O nce t he mode has been selected, press
the ENTER button to setup or automatically return to the main functions without any
change after 8 seconds. To go back to the functions without any change press the MENU
button again.
Led Display
Press the MENU button up to when the is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the (Led on) or
(Led off) mode. Once the mode has been selected, press the ENTER button to setup
or automatically return to the main functions without any change after 8 seconds. To go back
to the functions without any change press the MENU button again.
Display Inversion
It is good for you to install the unit on the floor or under ceiling. Press the MENU button up to
when the is blinking on the display. Use the ENTER button to change to the mode
(display inversion), It will automatically store after 8 seconds. Or press the ENTER
button again return to the mode (display normal). To go back to the functions press
the MENU button again.
Display normal mode for the fixture putting on the floor.
Display inversion mode for the fixture fixing under ceiling.
Focus Adjust
Press the MENU button up to when the is blinking on the display. Pressing ENTER
button, the unit will focus on center position. To go back to the functions press the MENU
button again.
Self-Test
Press the MENU button up to when the is blinking on the display. Pressing ENTER button and the unit will run self-test by built in program. To go back to the functions press the
MENU button again.
Press the MENU button up to when the is blinking on the display. Pressing ENTER button and the display will show the number of working hours of the unit. To go back to the
functions press the MENU button again.
Reset
Press the MENU button up to when the is blinking on the display. Pressing ENTER button and all channels of the unit will return to their standard position. To go back to the
functions press the MENU button again.
5. How To Control The Unit
You can operate the unit in three ways:
1. By master/slave built-in preprogram function
2. By easy controller
3. By IL-0824 ( please refer to the user guide of iLead controller ) or universal DMX
controller
No need to turn the unit off when you change the DMX address, as new DMX address setting
12F
will be effected at once. Every time you turn the unit on, it will show its item number on the
display and move all the motors to their ‘home’ position and you may hear some noises for
about 20 seconds. After that the unit will be ready to receive DMX signal or run the built in
programs.
5.1 Master/Slave Built In Preprogrammed Function
By linking the units in master/slave connection, the first unit will control the other units to give
an automatic, sound activated, synchronized light show. This function is good when you want
an instant show. Its DMX input jack will have nothing plugged into it, and Its master LED will
be constantly on and sound LED will flash to the music. The other units will have to set in
slave mode and select (normal) or (2 light show) mode (3
light show) mode or (4 light show), Their DMX cables plugged into the DMX input
jacks (daisy chain) and the slave led lights will constantly on.
and only for color-change.
2-light show
In (slave mode), means the unit works normally and means 2-light
show. In order to create a great light show, you can set on the second unit to get contrast movement to each other, even if you have two units only.
Loading...