Manufacturer name, address
Product model number
Year of manufacture
E
TEC
allowance with capability
adjustments when discrete graphics cards
are disabled (from 1 July 2014)
172 kWh/year 188 kWh/year 223 kWh/year
E
TEC
allowance with capability
adjustments when discrete graphics cards
are enabled (from 1 July 2014)
241 Watt 257 kWh/year 292 kWh/year
E
TEC
allowance with capability
adjustments when discrete graphics cards
are disabled (from 1 January 2016)
126 kWh/year 134 kWh/year 146 kWh/year
E
TEC
allowance with capability
adjustments when discrete graphics cards
are enabled (from 1 January 2016)
164 Watt 172 kWh/year 200 kWh/year
Whether all discrete graphics card are
enabled during the test
Whether switchable graphics mode with
UMA is driving the display during the test
E
TEC
of highest power-demanding
configuration
131.97 kWh/year 133.21 kWh/year 119.71 kWh/year
Idle state power demand 35.87 Watt 35.51 Watt 32.83 Watt
Sleep mode power demand 2.39 Watt 2.13 Watt 2.16 Watt
Sleep mode with WOL enabled power
demand
2.48 Watt 2.22 Watt 2.45 Watt
Off mode power demand 0.33 Watt 0.33 Watt 0.33 Watt
Off mode with WOL enabled power
demand
0.33 Watt 0.33 Watt 0.33 Watt
Maximum power demand Not applicable Not applicable Not applicable
Internal power supply (IPS) efficiency at
10 %, 20 %, 50 % and 100 % of rated
output power
10% - 87.62%
20% - 88.80%
50% - 87.51%
100% - 95.27%
10% - 87.62%
20% - 88.80%
50% - 87.51%
100% - 95.27%
10% - 87.62%
20% - 88.80%
50% - 87.51%
100% - 95.27%
External power supply's (EPS) average
active efficiency
Not applicable Not applicable Not applicable
Noise levels (the declared A-weighted
sound power level, L
WAd
) of idle mode
Noise levels (the declared A-weighted
sound power level, L
WAd
) of "HDD random
seek" mode
Technical Documentation of (EU) No 617/2013
Acer Italy s.r.l,
Via Lepetit, 40, 20020 Lainate (MI) Italy
Veriton X2630;
Veriton X2631.
Minimum number of loading cycles that
the batteries can withstand
Not applicable Not applicable Not applicable
Configuration of memory 2 ~ 16 GB 2 GB 4 ~ 16 GB
Configuration of internal storage 1 piece 1 piece 1 piece
Configuration of discrete television tuner 0 piece 0 piece 0 piece
Configuration of discrete audio card 0 piece 0 piece 0 piece
Configuration of discrete graphics cards 1 piece 1 piece 1 piece
Configuration of discrete graphics cards
category
The battery in this product cannot be
easily replaced by users themselves
Not applicable Not applicable Not applicable
For products with an integrated display,
the total content of mercury is
Not applicable Not applicable Not applicable
Measurement methodology for ETEC
Measurement methodology for idle mode
Measurement methodology for sleep
mode
Measurement methodology for off mode
Measurement methodology for IPS
efficiency
Measurement methodology for EPS
efficiency
COMMISSION REGULATION (EU) No 617/2013 of 26 June
2013 implementing Directive 2009/125/EC of the European
Parliament and of the Council with regard to ecodesign
requirements for computers and computer servers:
ANNEX II Ecodesign requirements and timetable:
1.1.1. E
TEC
formula.
EN 62623:2013 — Desktop and notebook computers —
Measurement of energy consumption:
5.2. Test setup;
5.3.5. Measuring short idle mode;
5.7. True RMS watt meter specification;
5.8. True RMS watt meter accuracy;
Annex E.2 (informative) ENERGY STAR® V5 compliant testing
methodology.
EN 62623:2013 — Desktop and notebook computers —
Measurement of energy consumption
5.2. Test setup;
5.3.3. Measuring sleep mode;
5.4. Test conditions;
5.7. True RMS watt meter specification;
5.8. True RMS watt meter accuracy.
EN 62623:2013 — Desktop and notebook computers —
Measurement of energy consumption
5.2. Test setup;
5.3.2. Measuring off mode;
5.4. Test conditions;
5.7. True RMS watt meter specification;
5.8. True RMS watt meter accuracy.
Generalized Test Protocol for Calculating the Energy Efficiency
of Internal Ac-Dc and Dc-Dc Power Supplies Revision 6.6
(April,2012).