The information in this manual has been carefully checked and is believed to be
accurate. ACNODES assumes no responsibility for any infringements of patents or
other rights of third parties, which may result from its use.
ACNODES assumes no responsibility for any inaccuracies that may be contained in
this document. ACNODES makes no commitment to update or to keep current the
information contained in this manual.
ACNODES reserves the right to make improvements to this document and/or product
at any time and without notice.
No part of this document may be reproduced, stored in a retrieval system, or
transmitted, in any form or by any means, electronic, mechanical, photocopying,
recording, or otherwise, without the prior written permission of ACNODES.
Copyright 2002 by ACNODES
All rights reserved.
May 2002, Version A1
ii
Page 3
Safety Approvals
!" CE Marking
!" FCC Class A
FCC Compliance
This equipment has been tested and complies with the limits for a
Class-A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. If not installed and used in
accordance with proper instructions, this equipment might generate or
radiate radio frequency energy and cause harmful interference to
radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measurers:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and
receiver.
3. Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV
technician for help.
Shielded interface cables must be used in order to comply with
emission limits.
iii
Page 4
Safety Precautions
Before getting started, read the following im portant cautions.
1. The PANEL PC 1000 does not come equipped with an
operating system. An operating system must be loaded
first before installing any software into the computer.
2. Be sure to ground yourself to prevent static charge when
installing the internal components. Use a grounding wrist
strap and place all electronic components in any
static-shielded devices. Most electronic components are
sensitive to static electrical charge.
3. Disconnect the power cord from the PANEL PC 1000
before making any installation. Be sure both the system
and the external devices are turned OFF. Sudden surge
of power could ruin sensitive components. Make sure the
PANEL PC 1000 is properly grounded.
4. The brightness of the flat panel display decreases with
usage. However, hours of use vary depending on the
application environment.
5. Turn OFF the system power before cleaning. Clean the
system using a cloth only. Do not spray any liquid cleaner
directly onto the screen. The PANEL PC 1000 may come
with or w/o a touch screen. Although the touch screen is
chemical resistant, it is recommended that you spray the
liquid cleaner on a cloth first before wiping the screen. In
case your system comes without the touch screen, you
must follow the same procedure and not spray any
cleaner on the flat panel directly.
6. Avoid using sharp objects to operate the touch screen.
Scratches on the touch screen may cause malfunction
or internal failure to the touch screen.
7. The flat panel display is not susceptible to shock or
vibration. When assembling the PANEL PC 1000, make
sure it is securely installed.
iv
Page 5
8. Do not open the system’s back cover. If opening the
cover for maintenance is a must, only a trained
technician is allowed to do so. Integrated circuits on
computer boards are sensitive to static electricity. To
avoid damaging chips from electrostatic discharge,
observe the following precautions:
#"
Before handling a board or integrated circuit, touch an
unpainted portion of the system unit chassis for a few
seconds. This will help to discharge any static electricity on
your body.
#"
When handling boards and components, wear a
wrist-grounding strap, available from m ost el ectr onic
component stores.
Trademarks Acknowledgments
ACNODES is a trademark of ACNODES Inc.
ALI is a trademark of Acer Laboratories, Inc.
AMD is a trademark of Advanced Micro Devices, Inc.
AMI is a trademark of American Mega trends, Inc.
Cyrix is a trademark of Cyrix Corporation.
ELO is a trademark of ELO Touch Systems, Inc.
IBM, PC/AT, PS/2, VGA are trademarks of International
Business Machines Corporation.
Intel and Pentium are trademarks of Intel Corporation.
MS-DOS, Microsoft C and Quick BASIC are trademarks of
Microsoft Corporati on.
SMC is a trademark of Standard Microsystems
Corporation.
C&T is a trademark of Chips and Technologies, Inc.
SST is a trademark of Silicon Storage Technology, Inc.
UMC is a trademark of United Microelectronics
Corporation.
Other brand names and trademarks are the properties of
their respective owners.
v
Page 6
This page does no t contain any information.
This page does no t contain any information.
This page does no t contain any information.This page does no t contain any information.
The PANEL PC 1000 super slim industrial PANEL PCs are mainly
designed for industrial automation and some space-constricted
embedded applications. For some space-concerned industries, a
traditional PC with a separate main system, display monitor and
keyboard is simply not integrated enough.
Ruggedly designed, the PANEL PC 1000 is 100% IBM PC/A T
compatible and it inte grates super I/O s, VGA, 10. 4” T FT, touch screen,
Ethernet, and packs special industrial features like watchdog timer,
CMOS double backup, all in a single system. The full PC
functionality coupled with its industrial-grade construction easily tailors
the system for any embedded applications and allows the system to
endure continuous operation in any hostile industrial environments
where stability and reliability are a must. Common applications of the
PANEL PC 1000 include tooling machine, POI terminal, stand-alone
KIOSK, medical instrument, mobile communication device and
banking system - to name just a few.
Designed by the PC experts for PC professionals, the PANEL PC
1000 is virtually the ultimate one-step solution for your space-limited
applications.
Introduction
1
Page 10
PANEL1000-370 All-in-One PANEL PC User’s Manual
1.2 Specifications
Core System for system board
$"
$"
$"
$"
$"
$"
$"
I/O System
$"
$"
$"
$"
$"
I ntel Celeron 300 up to 733 MHz;
CPU:
Intel Pentium III 500 up to1.0Ghz
System Chipset:
BIOS:
System Memory:
L2 Cache:
Real Time Clock:
Watchdog Timer:
Standard I/O:
− 4 x seri al ports with p ower; 3 x RS-232, 1 x
− 1 x parallel port, SPP/EPP/ECP
− 1 x External FDD Interface
− 2 x HDD Interface
− 1 x Keyboard Interface
− 1 x PS/2 Mouse Interface
− 2 x USB Port s
Digital I/O:
Ethernet:
− 32-bit Pl ug & Play Fast Ethernet Controller
− RJ-45 connector
Audio:
− ESS Solo-1 1938 32-b it PCI 2.1 Audi o Drive control ler
VGA/Flat Panel Controller:
− AGP Int erface C&T69000 contr oller with int egrated 2M B
− Simultaneously supports CRT and flat panel displays
Award BIOS, Y2K compliant
2Mbit Flash ROM, DMI , Plug and Play
RS-232/422/485 jumper selecta ble
Input x 4, Output x 4
SDRAM
Intel 440BX Core Logic Controller
One 168-pin DIMM (PC-100)
Maximum SDRAM of up to 256MB
Integrated in CPU
Dallas STM48T86PC1 or latest product
System reset or Non-Mask Interrupt
software programmable Time interval and
jumper selectable;
64 levels, 0.5~8 / 5~80 / 50~800 / 100~1600
seconds
2
Introduction
Page 11
PANEL PC 1000 All-in-One PANEL PC User’s Manual
Built-in Peripherals
$"Standard 100W power supply
$"2.5” Hard disk (540MB or up)
$"10.4” ELO anti-glare analog resistive touch screen with
RS- 232 controller sharing COM3
$"System cooling fan
NOTE:
System Specification
Optional DC power supplies rated at +12V, +24V and
+48V are also available. (See Appendix A)
$"10.4” TFT with 640 x 480 resolution
$"External FDD interface
$"NEMA 4/12 sealed front panel
$"Heat dispensing design
$"PC/104 expansion Bus
$"One free slot for PCI/ISA expansion
$"Net weight: 4.2 KGS
$"Dimension (main body size):
− PANEL PC 1000
− 330 x 266 x 93 mm (with
one ISA or PCI expansion
card)
$"Operating Temperature Range: 0
o
C ~ 40oC
$"Relative Humidity: 5% ~ 95%; non-condensing
NOTE:
For more detailed information on the system engine
board used in your PANEL PC, refer to the system board
User’s Manual that came with the system packaging.
Introduction
3
Page 12
PANEL1000-370 All-in-One PANEL PC User’s Manual
1.3 Dimensions
PANEL1000-370 10.4" FLAT PANEL PC (unit: mm)
4
Introduction
Page 13
PANEL PC 1000 All-in-One PANEL PC User’s Manual
1.4 I/O Outlets
The following figure shows the I/O arrangement of the PANEL PC
1000. The backside of the chassis contains most of the connectors.
1. Ethernet RJ-45 phone
jack
2. PS/2 mouse
3. Keyboard
4. External FDD
5. 4-channel Digital
Inputs/outputs
6. Parallel port
7. COM4
Introduction
8. COM3
9. COM2
10. COM1
11. VGA port IF
12. AC inlet
13. Power switch
14. +5V/12V DC outlet
5
Page 14
PANEL1000-370 All-in-One PANEL PC User’s Manual
1.5 Utilities Supported
Watchdog Utility
%"
Ethernet Utility
%"
VGA Drivers
%"
Touch screen Utility
%"
6
Introduction
Page 15
PANEL PC 1000 All-in-One PANEL PC User’s Manual
C h a p t e r 2
System Configuration
This chapter details the system parts and components with figures.
Sections include
$"System Major Parts $"Panel Mount
2.1 System Configuration
2.1.1 Front View
The figure below shows the front views of PANEL PC1000.
1. Power LED
2. HDD LED
3. Ethernet LED
System Configuration
3
2
1
7
Page 16
PANEL1000-370 All-in-One PANEL PC User’s Manual
2.2 Panel Mount
The PANEL PC 1000 is mainly designed for panel mount application.
To mount the PA NEL PC 1000, the standard set of mounting kit
(included in the system packaging) is needed. Please refer to the
following figure.
8 System Configuration
Page 17
PANEL PC 1000 All-in-One PANEL PC User’s Manual
C h a p t e r 3
System Installation
This chapter describes the installation and the cable connection to the
system connectors. See system board User’s Manual that came with
your PANEL PC packaging for more details. Sections in this chapter
includes
$"CPU
$"DRAM
$"HDD
$"4 x Serial
Ports
$"Parallel Port
The PANEL PC 1000 has a Pentium III little board with a free PCI/ISA
slot inside. It already builds in a Pentium III CPU, relevant DRAM and
a 2.5” HDD. These are all standard and the system is ready to play.
System performance can be increased by upgrading to a higher
performance CPU, higher capacity DRAM modules and hard disk
drive. The user can use the I/O ports located at the back side of the
chassis to connect external peripheral devices, such as a monitor,
serial devices, parallel printer…etc.
NOTE:
Make sure the power cord is disconnected before any
installation. To install any inte rnal device such as CPU,
DRAM and HDD, take out the rear chassis cover first.
The standard PANEL PC 1000 system already builds in Pentium
III-level CPU. When upgrading to a new CPU of the same level, follow
the instructions below;
1.
To remove the existing CPU requires the use of a chip
puller.
2.
Locate pin 1 at the corner of the CPU socket and align
the CPU’s pin 1 with the pin 1 on the socket.
3.
Place the CPU in the socket. If the insertion of the CPU to
the socket is not easy, then check whether the notch on
the corner of the CPU and the notch on the socket are
properly aligned.
4.
When a new CPU is installed, other settings on the system
control board including CPU type, CPU bus clock and
CPU voltage may need to be adjusted. Make sure all the
settings are correct for the installed CPU. (See the CPU
jumper settings in the CPU card User’s Manual that came
with the PANEL PC packaging).
3.2 DRAM
The system control board provides
supporting system memory up to 256MB.
To install the memory module;
1.
Disconnect all power sources.
2.
The memory module can only fit into the socket one way.
Holding the memory module with the notch on the upper
right corner, then insert the memory module at a 45°
Angle and push the module upright until it clicks into
place.
The system auto detects the new memory size and it is not necessary
to change the system configuration after installation.
10
1 x 168-pin DIMM
System Installation
sockets
Page 19
PANEL PC 1000 All-in-One PANEL PC User’s Manual
3.3 HDD
The standard PANEL PC 1000 already builds in a 2.5” hard disk drive.
If the user intends to remove the existing device for repair or for a
higher-capacity one, then follow the installation instructions below.
1.
Take out the screws and remove the HDD bracket.
Mounting orientation of the HDD brackets on PANEL PC
1000 are not similar to each other. The four screws
mounting the PANEL PC 1000 HDD bracket sits at the
bottom of the bracket.
2.
Reinstall the new hard disk driver to the HDD bracket and
screw the HDD bracket to the system compartment again.
The four rubber stands act as cushions to lessen the
vibration that usually causes damage to mechanical
devices like a hard disk driver.
3.
Use the IDE cable to connect the HDD to the IDE pin
connector. Match pin 1 of the HDD and the pin 1 of the
cable.
System Installation
11
Page 20
PANEL1000-370 All-in-One PANEL PC User’s Manual
3.4 4 x Serial Ports
The PANEL PC 1000 provides four onboard serial ports installed on
the bottom rear side of the chassis. Arrangements on PANEL PC
1000 specify COM1, COM2, COM3 providing RS-232 interface, and
with its RS-422/485 interface connected to COM4. Each serial port
comes with +5V/+12V power capabilities on both Pin 1 and Pin 9,
ready to accommodate a wide array of serial devices such as fax
modem, scanner, serial mouse, touch screen...etc.
screen option is included, its controller will share COM3.
COM1 to COM4 are all D-SUB 9-pin connectors. To attach to any
serial device, just plug in the device connector to the 9-pin D-SUB. In
terms of transmission distance, the RS-422/485 will perform better
than RS-232. In this case, the COM2 is suggested to be set to
RS-422/485 and the related jumpers have to be set correctly first (see
the system board User’s Manual). The RS-485 pin assignment is
listed below.
If the touch
12
12 345
6789
Pin #
1
TX- DATA-
2
TX+ DATA+
3
RX+ No connector
4
RX- No connector
5
GND GND
6
No connector No connector
7
No connector No connector
8
No connector No connector
9
No connector No connector
Signal Name
R2-422 RS-485
System Installation
Page 21
PANEL PC 1000 All-in-One PANEL PC User’s Manual
3.5 Parallel Port
The printer interface is a 25-pin D-SUB connector. To connect any
parallel device, just plug in the device connector to the 25-pin D-SUB.
3.6 VGA
The PANEL PC 1000 has an analog RGB interface connector. It is
able to connect to an expansion CRT monitor, and the system can
display on both the flat panel and the CRT simultaneously.
3.7 Ethernet
The PANEL PC 1000 provides an NE2000 compatible Ethernet
(RJ-45) interface. For network connection, just plug in one cable end
of the PANEL PC 1000 100-Base-T Hub into the standard Ethernet
phone jack. The pin assignment of the RJ-45 is listed below;
RJ-45 Connector Pin Assignment
1
234567
RJ-45
System Installation
8
Pin Description
1
Tx+ (Data transmission positiv e)
2
Tx- (Data transmission negative)
3
Rx+(Data reception positive)
6
others
Rx- (Data reception negative)
Not use
13
Page 22
PANEL1000-370 All-in-One PANEL PC User’s Manual
3.8 Digital I/Os
The PANEL PC 1000 provides a digital I/O of 4-channel inputs/outputs
for simple automation control. For example, it can be used to control
the opening and closing of the cash drawer on a POS system. It can
also be used for UPS contr ol. It c omes with a 15-pin D-SUB c on nec tor,
and its pin position and pin assignment is shown on the following
page.
Digital I/O Pin Assignment
12345
6
7
8
9
11
12
13
14
15
10
P1
OUT 1
P2
OUT 2
P3
OUT 3
P4
OUT4
P5
P6
P7
P8
GND
GND
GND
GND
P9
P10
P11
P12
P13
P14
P15
GND
GND
IN1
IN2
IN3
IN4
GND
3.9 Keyboard
The PANEL PC 1000 provides a standard PS/2 keyboard connector. If
the user would like to use AT keyboard interface, a conversion cable
is also provided to make this connection.
3.10 PS/2 Mouse
The PANEL PC 1000 has one PS/2 mouse connector. A simple
plug-in will make the connection.
14
System Installation
Page 23
PANEL PC 1000 All-in-One PANEL PC User’s Manual
3.11 External FDD
The PANEL PC 1000 does not build in any floppy disk drive into the
main system. Rather, it provides a FDD interface. An external FDD
cable is provided to connect a standard 3.5” FDD to the system for
system O/S and application software installation. The pin positions
and pin assignments are listed on the next page.
NOTE:
An optional external FDD is available for the
PANEL1000-370 system. Consult your authorized dealers or
sales representatives for more information.
The PANEL PC 1000, this comes as a standard system feature. If the
system comes with expansion capability, then the system includes a
PCI/ISA expansion riser card to accommodate either an ISA or PCI
device at a given time. Due to the internal space limitation, only a
half-size expansion card can be adapted. To use the ISA or PCI
expansion, refer to the following figure and follow the installation
instructions below;
1.
Plug the riser card into the onboard PCI/ISA slot first.
2.
Screw the metal opening to the power supply bracket
and the multi-I/O conversion metal piece.
3.
Plug either an ISA or PCI card into the ISA or PCI slot on the
riser card and screw the expansion card to the metal
opening piece. All the connectors of the expansion card
will come out from the opening on the rear cover for
further cable connection.
4.
Screw the rear cover to the chassis.
Please also note that the total height of the system with expansion
slot is 93 mm.
16
System Installation
Page 25
PANEL PC 1000 All-in-One PANEL PC User’s Manual
3.13 System O/S and Software Installation
The PANEL PC 1000 is not equipped with any operating system. It
builds in a 2.5” HDD and 1.5MB Solid State Disk as memory storage
device. As both devices are built in the system chassis, to load any
O/S or application software into the computer, an external device is
needed to act as a bridge. There are three major ways to load
software into the system.
1.
Use an external FDD: Attach a 3.5” FDD to the external
FDD port via the provided external FDD cable.26-pin FDD
connector must be plugged into the system FDD
connector; the 34-pin standard 3.5” FDD signal connector
and the 4-pin FDD power connector are connected to the
standard 3.5” FDD. Then, configure the system BIOS setup
and insert a 3.5” disk containing necessary software and
start the installation.
2.
Use Ethernet: If the Ethernet BOOTROM is already included
in the system, the user can boot up the system via
BOOTROM and download system O/S or application
software from the net.
3.
Use External CD-ROM/ HDD: When using an external
CD-ROM or HDD for software installation on P PANEL PC
1000 an optional P-IDE device is needed. The P-IDE device
is a converter to convert the parallel port to the IDE
interface.
System Installation
17
Page 26
PANEL1000-370 All-in-One PANEL PC User’s Manual
This page does no t contain any information.
This page does no t contain any information.
This page does no t contain any information.This page does no t contain any information.
18
System Installation
Page 27
PANEL PC 1000 All-in-One PANEL PC User’s Manual
A p p e n d i x A
Power Supply Specifications
Standard AC Power Supplies
PANEL PC 1000 Power Supply
The power supply used in the PANEL PC 1000 is a 100W open frame
power supply. The specifications and features of this special power
supply are listed in the following sections.
Specifications
$"
High efficiency 100W output
$"
Universal input 100 to 240 VAC
$"
Over-voltage protection
$"
Small size 3” X 5” footprint
$"
Continuous short circuit protection
$"
Conductive EMI meets FCC class B
Output Specifications
$"
Voltage Accuracy
%"
+5VDC primary output: + 5%
%"
Auxiliary output: + 5%
$"
Total output p ower
%"
Convection cooled: 100W
%"
Forced air cooling: 125W @ 25CFM
$"
Hold-up time: 50ms type.
$"
Over-voltage protection: approx. 5.8V
$"
Short circu it protecti on: Continuous
$"
Ripple and noise: 1% peak ~ peak max.
Input Specifications
$"
Input voltage range: 100~240 VAC
$"
Inrush current: 2.4A at 100VAC or 30A at 240VAC (co ld st ar t )
$"
Input frequency: 47~63 Hz
$"
Line regulation: + 1%
Power Supply Specifications
19
Page 28
PANEL1000-370 All-in-One PANEL PC User’s Manual
General Specifications
$"
Efficiency: 86%
typ.
Environmental Specifications
$"
Operating temperature range: 0°C to 40°C
$"
Storage temperature range -40°C to +85°C
$"
Humidity, non-condensing: 5% ~ 95%
$"
Altitude: 0 to 10,000 feet
International Standards
Safety Standards
$"
Designed to meet the following standards:
UL 1950, CSA 22.2 NO. 234, VDE EN 60 950
EMI Standards
$"
Designed to meet the following limits:
FCC docket 20780 curve “B”, EN55022 “B”
CE Standards
$"
Designed to meet the following standards:
IEC-801-2 Level 3 8KV air discharg e
IEC-801-3 Level 3 3V/M
IEC-801-4 Level 3 2KV
IEC-801-5 Level 3 2KV
20
Power Supply Specifications
Page 29
PANEL PC 1000 All-in-One PANEL PC User’s Manual
Optional DC Power Supplies
(I) +12V DC Power Supply
Input Specifications
$"
Input voltage range: +9VDC to +18VDC
$"
Input current: 10A at +12VDC max.
Output Specifications
$"
Load Range:
Output
+5V
+12V
-12V
The output range of +12V, -12V and down with +5V setting.
At factory, all outputs in 60% rated load conditions, the
+5V output is set to between 4.95V and 5.05V, and the
other outputs are checked to be within the specified
voltage accuracy range.
$"
Ripple and Noise:
The peak-to-peak ripple and noise for +5V output is less
than 50mV and less than 100mV for +/-12V outputs, both at
rated loads. Measuring is done by 15MHz bandwidth
limited oscillosc ope and terminated e ach output with
0.47uF capacitor.
$"
Line Regulation:
The line regulation for +5V output is less than +/-1%, for 12V
is less than +/-2%, for –12V is less than +/-3% while
measuring at rated loadin g and +/-10% of input voltage
changing.
$"
Load Regulation:
The load regulation for +5V, +12Vare less than +/-3%, for
-12V is less than +/-5%, measuring is done by changing the
measured output loading +/-4 0% from 60% rated load, and
keep other output at 60% rated load.
Min. Load
0A 10A 4.95V to 5.05V
0A 1.5A (open) 11.4V to12.6V
0A 0.3A -11.4V to –12.6V
Rated Load
Voltage Accuracy
Power Supply Specifications
21
Page 30
PANEL1000-370 All-in-One PANEL PC User’s Manual
General Features
$"
Efficiency:
The efficiency is 70% typical while measuring at nomi nal
line and rated load.
$"
Protection:
For some reason the power supply fails to control itself, the
built-in over -voltage protecti on circ uit will sh ut down the
outputs to prevent damage to extern al circu its. The tri p
point of crowbar circuit is around 5.7V to 7.0V. The power
supply will go into latch -off mode against sh ort circu it or
over load conditions, and have to turn OFF and then ON
the DC input to re start the power supply.
Environmental Specifications
$"
Operating temp. range: 0°C to 50°C with forced air 20cfm
$"
Storage temperature range: -40°C to +85°C
International Standards
Safety Standards
$"
Designed to meet the following standards:
UL 1950, CSA 22.2 NO. 234, TUV/LVD EN60 950
EMI Standards
$"
Designed to meet the following limits::
FCC docket 20780 curve “B”, EN55022 “B”
22
Power Supply Specifications
Page 31
PANEL PC 1000 All-in-One PANEL PC User’s Manual
(II) +24V DC Powe r Supply
Input Specifications
$"
Input voltage range: +18VDC to +36VDC
$"
Input current: 5A at +24VDC max.
Output Specifications
$"
Load Range:
Output
+5V
+12V
-12V
The output range of +12V, -12V and down with +5V setting.
At factory, all outputs in 60% rated load conditions, the
+5V output is set to between 4.95V and 5.05V, and the
other outputs are checked to be within the specified
voltage accuracy range.
$"
Ripple and Noise:
The peak-to-peak ripple and noise for +5V output is less
than 50mV and less than 100mV for +/-12V outputs.
Measuring is done by 15MHz bandwidth limited
oscilloscope and terminated each output with 0.47uF
capacitor.
$"
Line Regulation:
The line regulation for +5V output is less than +/-1%, for
+12V is less than +/-2%, for –12V is less than +/-3% while
measuring at rated loadin g and +/-10% of input voltage
changing.
$"
Load Regulation:
The load regulation for +5V is less than +/-3%, for +12V is
less than +/-5%, -12V is less than +7% -3%, measuring is
done by changing the measured output loading +/-40%
from 60% rated load, and keep other output at 60% rated
load.
Min. Load
0A 10A 4.95V to 5.05V
0A 1.5A (open) 11.4V to12.6V
0A 0.3A -11.4V to –12.6V
Rated Load
Voltage Accuracy
Power Supply Specifications
23
Page 32
PANEL1000-370 All-in-One PANEL PC User’s Manual
General Features
$"
Efficiency:
The efficiency is 75% typical while measuring at nomi nal
line and rated load.
$"
Protection:
For some reason the power supply fails to control itself, the
built-in overvoltage protection circuit will shut down the
outputs to prevent damage to extern al circu its. The tri p
point of crowbar circuit is around 5.7V to 7.0V. The power
supply will go into latch -off mode against sh ort circu it or
over load conditions, and have to turn OFF and then ON
the DC input to re start the power supply.
Environmental Specifications
$"
Operating temp. range: 0°C to 50°C with forced air 20cfm
$"
Storage temperature range: -40°C to +85°C
International Standards
Safety Standards
$"
Designed to meet the following standards:
UL 1950, CSA 22.2 NO. 234, TUV/LVD EN60 950
EMI Standards
$"
Designed to meet the following limits:
FCC docket 20780 curve “B”, EN55022 “B”
24
Power Supply Specifications
Page 33
PANEL PC 1000 All-in-One PANEL PC User’s Manual
(III) +48V DC Power Supply
Input Specifications
$"
Input voltage range: +36VDC to +72VDC
$"
Input current: 3A at +48VDC max.
Output Specifications
$"
Load Range:
Output
+5V
+12V
-12V
At factory, all outputs in 60% rated load conditions, the
+5V output is set to between 4.95V and 5.05V, and the
other outputs are checked to be within the specified
voltage accuracy range.
$"
Ripple and Noise:
The peak-to-peak ripple and noise for +5V output is less
than 60mV and less than 100mV for +/-12V outputs.
Measuring is done by 15MHz bandwidth limited
oscilloscope and terminated each output with 0.47uF
capacitor.
$"
Line Regulation:
The line regulation for +5V output is less than +/-1%, for
+12V is less than +/-2%, for –12V is less than +/-3% while
measuring at rated loadin g and +/-10% of input voltage
changing.
$"
Load Regulation:
The load regulation for +5V is less than +/-3%, for +12V is
less than +/-5%, -12V is less than +7% -3%, measuring is
done by changing the measured output loading +/-40%
from 60% rated load, and keep other output at 60% rated
load.
Min. Load
0A 10A 4.95V to 5.05V
0A 1.5A 11.4V to12.6V
0A 0.3A -11.4V to –12.6V
Rated Load
Voltage Accuracy
Power Supply Specifications
25
Page 34
PANEL1000-370 All-in-One PANEL PC User’s Manual
General Features
$"
Efficiency:
The efficiency is 75% typical while measuring at nomi nal
line and rated load.
$"
Protection:
For some reason the power supply fails to control itself, the
built-in over -voltage protecti on circ uit will sh ut down the
outputs to prevent damage to extern al circu its. The tri p
point of crowbar circuit is around 5.7V to 7.0V. The power
supply will go into latch -off mode against sh ort circu it or
over load conditions, and have to turn OFF and then ON
the DC input to re start the power supply.
Environmental Specifications
$"
Operating temp. range: 0°C to 50°C with forced air 20cfm
$"
Storage temperature range: -40°C to +85°C
International Standards
Safety Standards
$"
Designed to meet the following standards:
UL 1950, CSA 22.2 NO. 234, TUV/LVD EN60 950
EMI Standards
$"
Designed to meet the following limits:
FCC docket 20780 curve “B”, EN55022 “B”
26
Power Supply Specifications
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.