AccuTempProducts, Inc. is not responsible for theinstallation and/or modifications to the electrical orgas supply
sources.
It is recommended that the wall receptacle be placed aslow as State and Local codes allow.Placement in high heat
zonessuch as, just above, below orbeside the exhaust flue, will causeservice issues that will not becovered under
theproduct warranty.
Ane xternal regulator sh ouldnot be used unless the supplygas pressure is more than 0.5 psig.)
If the altitude is greater tha n2, 000 feet above sea level, conta ct the AccuTemp Technica lS ervices Department to
verifythe correct orificesize for main burner.
1. Isthe steamer beinginstalled at analtitude greater than 2,000 feet?(circle one) Yes/ No
2. Is an external regulator connectedto the steamer? (circle one)Yes /No
3. Isthe 120 Vac or240 Vac wall receptacleposition in alow heat zone. (circleone) Yes / No
4. If the steamer has legs, havethe (4) rubber foot tips been installed?(circle one) Yes /No
5. Is the steamer level ?( circleone) Yes /No
6. Is thesteamer hard connectedto the gassupply line? (circleone) Yes / No
7. If the steameris connected witha flexible hose,is a restraining device used? (circle one) Yes / No
9. Does the steamer operate properly when all gas appliances are operating? (circle one) Yes/ No
10. Verifythe water temperature in COOK MODE ( _______°F)
Iaccept this Start-UpForm as complete and accurate:
___________________________________Restaurant Management Date:___/___/___
Note: This Start-UpFormmust becompletelyfilledout and faxedor mailed to theAccuTempTechnical&
CustomerSupport Department, before thewarranty is activated.
AccuTempProducts, Inc
Attn: Technical& Customer SupportDepartment
8415North ClintonPark
Ft.Wayne, IN 46825
Phone:+1-260-469-0415 or 1-800-480-0415
Fax: +1-260-493-8914
INSTALLATION & OWNERS MANUAL
SERIAL #
MODEL #
Please ll in your Serial # and Model # for quick reference when calling
AccuTemp Technical Service for support.
IMPORTANT WARRANTY INFORMATION
WARRANTY REGISTRATION - STARTUP FORM INSIDE THIS MANUAL MUST BE
REMOVED, COMPLETED, SIGNED BY CUSTOMER AND A COPY EMAILED, FAXED OR
MAILED BACK TO ACTIVATE THE WARRANTY PERIOD.
MP4010-1003
These installation instructions have been prepared for qualied gas and
electric equipment installation personnel, who should perform the installation,
initial eld start-up and complete the equipment adjustments described in this
manual.
REGISTRATION AND STARTUP FORM
EVOLUTION GAS STEAMER
This Page Left Intentionally Blank
MP4010-1003
EVOLUTION GAS STEAMER
IMPORTANT FOR YOUR SAFETY
The safety instructions listed below on this page should be posted in a
prominent location as a reminder of safe practices as well as recommended
actions to follow in the event of an equipment or facility utility issue.
WARNING
In the event a gas odor is detected, shut down all appliances at the main
gas shut-off valve and contact the local gas company or gas supplier service.
WARNING
WARNING
In the event of a power failure, do not attempt to operate this appliance.
WARNING
Do not store or use gasoline or other ammable vapors or liquids in the vicinity of this or
any other appliance.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating, and maintenance instructions
thoroughly before installing or servicing this equipment.
WARNING
Only qualied service technicians/electricians should perform the installation to ensure
that all electrical and safety requirements are met and that all wiring is performed in
accordance with all national, state and local electrical codes.
Serial Number _________ Model Number: _________________________________
Service Agency: ______________________ Technician: _____________________
NOTE:
AccuTemp Products, Inc. is not responsible for the installation and/or modications to the •
electrical or gas supply sources.
It is recommended that the wall receptacle be placed as low as State and Local codes allow. •
Placement in high heat zones such as, just above, below or beside the exhaust ue, will cause
service issues that will not be covered under the product warranty.
An external regulator should not be used unless the supply gas pressure is more than 0.5 psig.)•
If the altitude is greater than 2,000 feet above sea level, contact the AccuTemp Technical Services •
Department to verify the correct orice size for main burner.
Is the steamer being installed at an altitude greater than 2,000 feet? (circle one) Yes / No1.
Is an external regulator connected to the steamer? (circle one) Yes / No2.
Is the 120 Vac or 240 Vac wall receptacle position in a low heat zone. (circle one) Yes / No3.
If the steamer has legs, have the (4) rubber foot tips been installed ? (circle one) Yes / No4.
Is the steamer level ? (circle one) Yes / No5.
Is the steamer hard connected to the gas supply line? (circle one) Yes / No6.
If the steamer is connected with a exible hose, is a restraining device used? (circle one) Yes / No7.
Gas Pressure Measurements: Natural : _____ 5” WC (Regulator Valve Pressure Tap – 1/8” NPT) 8.
Propane : _____ 10” WC (Regulator Valve Pressure Tap – 1/8” NPT)
Does the steamer operate properly when all gas appliances are operating? (circle one) Yes / No9.
Verify the water temperature in COOK MODE ( _______°F)10.
I accept this Start-Up Form as complete and accurate:
___________________________________ Restaurant Management Date: ___/___/___
Note: This Start-Up Form must be completely lled out, emailed, faxed or mailed to the AccuTemp
Technical & Customer Support Department, before the warranty is activated.
AccuTemp Products, Inc
Attn: Technical & Customer Support Department
8415 North Clinton Park
Ft. Wayne, IN 46825
Phone: 260.469.0415 or 800.480.0415
Fax: 260.493.8914
email: service@accutemp.net
MP4010-1003
EVOLUTION GAS STEAMER
This Page Left Intentionally Blank
MP4010-1003
EVOLUTION GAS STEAMER
TABLE OF CONTENTS
TABLE OF CONTENTSPAGE 1
DOCUMENT HISTORYPAGE 1
SAFETY WARNINGS INFORMATIONPAGES 2-3
INSTALLATIONPAGES 4-12
OPERATION - ALL MODELSPAGES 13-16
OPERATION - CONNECTEDPAGES 17-18
OPERATION CONNECTIONLESSPAGES 19-20
TROUBLESHOOTINGPAGES 21-22
SERVICEPAGE 23
WARRANTYPAGE 24
DOCUMENT HISTORY
CURRENT
REVISION
10034/14/10N/AN/AInitial release of manual
MP4010-1003
DATEPRIOR
REVISION
DATECHANGE
EVOLUTION GAS STEAMER
1
SAFETY WARNINGS
SYMBOL DEFINITIONS
Symbols are used to attract your attention to possible dangers. They are only effective if the operator
uses proper accident prevention measures. Some of the symbols are boxed text, while other maybe
just picture icons. Please give this information the respect they deserve for safe operation.
WARNING TEXT BOXES
Below are denitions of the warning text boxes:
DANGER
Indicates a imminently hazardous situation which, if not avoided will, result in death or
serious injury
WARNING•
Indicates a potentially hazardous situation which, if not avoided, will result in death or
serious injury
CAUTION
Indicates a potentially hazardous situation which, if not avoided will result in minor or
moderate injury
NOTE
Advises reader of information or instructions vital to the operation or maintenance of the
equipment
MP4010-1003
EVOLUTION GAS STEAMER
2
SAFETY WARNINGS
MP4010-1003
EVOLUTION GAS STEAMER
3
INSTALLATION
Only qualied service technicians/electricians should preform the installation to ensure that all
electrical, gas and safety requirements are met and that all wiring, gas and plumbing installations are
preformed in accordance with all national, state and local codes.
The installation must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSA/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1 as
applicable.
The appliance and its individual shutoff must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 PSI(3.5kPA)
LOCATION AND PLACEMENT
The AccuTemp Evolution gas steamer can be placed on a commercial kitchen counter-top, ush
mounted or installed on a AccuTemp Evolution gas steamer stand. Provisions should be incorporated
in the kitchen to ensure an adequate supply of fresh air for proper combustion and ventilation. See
Fig. 1
EQUIPMENT CLEARANCE
LOCATIONCOMBUSTIBLENONCOMBUSTIBLE
SIDES1”0”
REAR2”0”
Fig. 1
UNPACKING
This appliance was carefully inspected before shipment from the factory. The transportation
company assumes full responsibility for safe delivery to the customer until customer acceptance of
the package. Careful inspection of the packaging and the appliance should be completed before
acceptance from the transportation company.
STEAMER LIFTING
Steamers are heavy enough to require additional manpower or powered assistance when installing or
moving the steamer.
LEVELING
The steamer must be installed in a level condition. An out of level condition may cause erratic operation and damage to the steamer. Damage of this kind is not covered by the limited warranty. Use a
spirit level resting on the top surface of the steamer to ensure it is level front to back and left to right.
COUNTER TOP INSTALLATION
In a counter top installation the steamer is leveled using the adjusters on the legs of the steamer.
Once this is complete it is required that the supplied (4) rubber foot tips must be installed to keep the
steamer from possibly sliding on the counter top under normal use.
STAND INSTALLATION
If a AccuTemp Evolution Gas Steamer Stand is used ensure the oor is level and place the two locking casters to the “ON” position.
All AccuTemp Evolution Gas Steamer Stand with casters, shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or CAN/CGA 6.16
and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use
with Gas Fuel, ANSI Z21.41 or CAN1-6.9.
MP4010-1003
EVOLUTION GAS STEAMER
4
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.