Improper installation, alteration, adjustment,service, cleaning or maintenance of this commercial appliance
could result in property damage, serious injury or death.
Read and understand the installation, operational, maintenance instructions before installing, servicing, or
operating this commercial appliance.
AccuTemp Products, Inc. · 8415 North Clinton Park · Fort Wayne, IN 46825 ·800 210-5907 · accutemp.net
PAGE 2
Page 2
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 3
WARNING SYMBOL DEFINITIONS
SYMBOL DEFINITIONS
Symbols are used to attract your attention to possible dangers. They are only effective if
the operator uses proper accident prevention measures. Some of the symbols are boxed
text; while others maybe just picture icons. Please give this information the respect they
deserve for safe operation.
Warning Text Boxes
Below are defi nitions of the warning text boxes.
DANGER
Indicates an imminently hazardous situation;
which, if unchanged, will result in death or
serious injury.
WARNING
Indicates a potentially hazardous situation;
which, if unchanged, will result in death or
serious injury.
Symbol Icons
Below are defi nitions of the symbol icons used
in this manual.
ALERT
Notifi es the reader of an import-
ant message or warning; usually a
safety related message.
INFORMATION
Notifi es the reader of an important
information that may or may not
be safety related.
CAUTION
Indicates a potentially hazardous situation;
which, if unchanged, will result in minor or
moderate injury.
NOTE
Advises the reader of information or
instructions, vital to the operation or
maintenance of the equipment.
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
CAUTION -
HOT SURFACE
DANGEROUS
VOLTAGE
EARTH GROUND
PAGE 3
Page 4
SAFETY PRECAUTIONS
DANGER
ELECTRICAL SHOCK HAZARD WHILE WORKING ON
ENERGIZED EQUIPMENT.
Unplug equipment prior to removing any components effected by electricity.
PERSONNEL INJURY HAZARD WHILE PICKING UP OR
MOVING HEAVY EQUIPMENT.
Always use at least 2 people and proper lifting techniques when picking-up, moving, or
fl ipping-over heavy equipment.
PAGE 4
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 5
IMPORTANT FOR YOUR SAFETY
The Safety Instructions listed on this page below, should be posted
in a prominent location as a reminder of safe practices; as well as,
recommended actions to follow in the event of an equipment
or facility’s utility issue.
WARNING
In the event of a Power Failure, DO NOT attempt to operate this appliance.
WARNING
DO NOT store or use Gasoline, or any other Flammable Vapor and/or Liquids in the vicinity of this
or any other appliance.
WARNING
IMPROPER installation, adjustment, alteration, service, or maintenance can cause personal injury
or death; and/or property damage. Read the installation, operation, and service/maintenance
instructions thoroughly; before installing or servicing this equipment.
WARNING
Only QUALIFIED service technicians/electricians should perform the equipment installation, to
ensure that all electrical and safety requirements are met; and that all wiring is performed in
accordance with all national, state, and local electrical codes.
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
PAGE 5
Page 6
WARNING & CAUTION NOTES
WARNING
ONLY QUALIFIED SERVICE TECHNICIANS
SHOULD PERFORM MAINTENANCE ON
THIS EQUIPMENT.
CAUTION
GRIDDLE MAY HAVE SHARP EDGES.
PAGE 6
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 7
Table of Contents
Sequence of Operation ................................................................................
When the “Accu-Steam™ G2” griddle is plugged in, AC line voltage is supplied to the lead-in contacts
of the contactor. From the contactor, line voltage is supplied to the primary side of the transformer. The
secondary side voltage out is 24VAC nominal. One leg of the secondary side of the transformer (24VAC) is
split and is connected to the contactor coil and the Hi-Limit thermostat. From the HI-Limit thermostat, the
24VAC leg is daisy chained to the main digital control board. The other secondary leg of power from the
transformer goes to the Hi-Limit and then daisy chains over to the main digital control board. At this time,
the system is waiting to be powered on via the Digital control board. Upon pressing the “ON” button on the
digital controller, the digital controller powers up and a relay on the digital controller is closed, thus making a
connection between one of the two 24VAC legs and the input of the HI-Limit thermostat. If the reading from
the Hi-Limit RTD (Resistive Thermal Device) is not too high, an output relay in the Hi-Limit controller will
be closed causing the contactor to pull in. Once the contactor pulls in, line voltage is sent to the solid state
relays and heating elements. If the internal temperature of the griddle is below the set point of the digital
controller as measured by the digital controller RTD sensor, the digital controller will output 24VDC to the
control side of the solid state relays, turning them on. When the solid state relay(s) are turned on, line voltage
is sent through the SSR connection to all the heating elements and the griddle heats up. When the griddle
heats up to the set point temperature, the digital controller RTD resistance changes and provides a signal to
the control board telling it that the set point temperature has been reached. When the digital controller sees
the resistance value for the set point temperature, it cuts power to the SSR(s) and breaks the connection to
the elements causing the griddle to stop heating further.
PAGE 8
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 9
Griddle Specifi cations Sheet
GENERIC
MODEL NO
EGX2083A2424 INCHES30 INCHES72020850/602710ELECTRIC1 INCH 1 INCHFLUSH225.5229.525835.5265293.5
EGX2083B2424 INCHES24 INCHES57620850/602710ELECTRIC1 INCH 1 INCHFLUSH35.5
EGX2083A3636 INCHES30 INCHES1,08020850/604015ELECTRIC1 INCH 1 INCHFLUSH306.5310.534759.5370406.5
EGX2083B3636 INCHES24 INCHES86420850/604015ELECTRIC1 INCH 1 INCHFLUSH59.5
EGX2083A4848 INCHES30 INCHES1,44020850/604015ELECTRIC1 INCH 1 INCHFLUSH369.0373.041864437482
EGX2083B4848 INCHES24 INCHES1,15220850/604015ELECTRIC1 INCH 1 INCHFLUSH64
EGX2301A2424 INCHES30 INCHES72023050/60199ELECTRIC1 INCH 1 INCHFLUSH225.5229.525835.5265293.5
EGX2301B2424 INCHES24 INCHES57623050/60199ELECTRIC1 INCH 1 INCHFLUSH35.5
EGX2401A2424 INCHES30 INCHES72024050/604010ELECTRIC1 INCH 1 INCHFLUSH225.5229.525835.5265293.5
EGX2401B2424 INCHES24 INCHES57624050/604010ELECTRIC1 INCH 1 INCHFLUSH35.5
EGX2403A2424 INCHES30 INCHES72024050/602410ELECTRIC1 INCH 1 INCHFLUSH225.5229.525835.5265293.5
EGX2403B2424 INCHES24 INCHES57624050/602410ELECTRIC1 INCH 1 INCHFLUSH35.5
EGX2403A3636 INCHES30 INCHES1,08024050/603515ELECTRIC1 INCH 1 INCHFLUSH306.5310.534759.5370406.5
EGX2403B3636 INCHES24 INCHES86424050/603515ELECTRIC1 INCH 1 INCHFLUSH59.5
EGX2403A4848 INCHES30 INCHES1,44024050/603515ELECTRIC1 INCH 1 INCHFLUSH369.0373.041864437482
EGX2403B4848 INCHES24 INCHES1,15224050/603515ELECTRIC1 INCH 1 INCHFLUSH64
EGX4155A2424 INCHES30 INCHES720380/400/415 50/60 13/13/149/9/10ELECTRIC1 INCH 1 INCHFLUSH225.5229.525835.5265293.5
EGX4155B2424 INCHES24 INCHES576380/400/415 50/60 13/13/149/9/10ELECTRIC1 INCH 1 INCHFLUSH35.5
EGX4155A3636 INCHES30 INCHES1,080380/400/41550/60 19/19/20 12/14/15ELECTRIC1 INCH 1 INCHFLUSH306.5310.534759.5370406.5
EGX4155B3636 INCHES24 INCHES864380/400/415 50/60 19/19/20 12/14/15ELECTRIC1 INCH 1 INCHFLUSH59.5
EGX4155A4848 INCHES30 INCHES1,440380/400/415 50/60 19/19/20 12/14/15ELECTRIC1 INCH 1 INCHFLUSH369.0373.041864437482
EGX4155B4848 INCHES24 INCHES1,152380/400/415 50/60 19/19/20 12/14/15ELECTRIC1 INCH 1 INCHFLUSH64
EGX4403A2424 INCHES30 INCHES72044050/601511ELECTRIC1 INCH 1 INCHFLUSH225.5229.525835.5265293.5
EGX4403B2424 INCHES24 INCHES57644050/601511ELECTRIC1 INCH 1 INCHFLUSH35.5
EGX4403A3636 INCHES30 INCHES1,08044050/602116ELECTRIC1 INCH 1 INCHFLUSH306.5310.534759.5370406.5
EGX4403B3636 INCHES24 INCHES86444050/602116ELECTRIC1 INCH 1 INCHFLUSH59.5
EGX4403A4848 INCHES30 INCHES1,44044050/602116ELECTRIC1 INCH 1 INCHFLUSH369.0373.041864437482
EGX4403B4848 INCHES24 INCHES1,15244050/602116ELECTRIC1 INCH 1 INCHFLUSH64
EGX4803A2424 INCHES30 INCHES72048050/601613ELECTRIC1 INCH 1 INCHFLUSH225.5229.525835.5265293.5
EGX4803B2424 INCHES24 INCHES57648050/601613ELECTRIC1 INCH 1 INCHFLUSH35.5
EGX4803A3636 INCHES30 INCHES1,08048050/602320ELECTRIC1 INCH 1 INCHFLUSH306.5310.534759.5370406.5
EGX4803B3636 INCHES24 INCHES86448050/602320ELECTRIC1 INCH 1 INCHFLUSH59.5
COOKING SURFACECOOKING
WIDTHDEPTHSIDESBACKBTTM
AREA
SQUARE
INCHES
VOLTAGEHz
AMPS
KW/HRHEAT SOURCE
TYPE
Minimum Recommended
Clearances
Griddle
Weight
LBS
W/legs
LBS
w/
Stand
w/
Casters
LBS
Pallet
weight
LBS
Ship
Weight
Legs
LBS
Ship Weight
Stands LBS.
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
PAGE 9
Page 10
Troubleshooting Guide
UNIT ON?
CORRECT
VOLT AGE
CHECK
INTERNAL
VOLT AGE
A
B
C
NO
NO
BREAKER ON?
UNIT PLUGGED
IN?
YES
YES
NO
NO
FAULT LIGHT?
D
E
OVERTEMP?YES
HEAT ON?
F
G
NO
UNIT HEATING
UP?
HEAT LIGHT ON?
YES
NO
NO
ERROR CODE
E001?
E002?
PROPER
TEMPERATURE
UNIT
OPERATING
NORMAL
H
YES
NO
YES
YES
YES
YESNO
Diagnostic Flow Chart
PAGE 10
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 11
Troubleshooting Guide
Power cord
A
disconnected
Breaker is trippedUnplug griddle and check line voltage at outlet.
B
TransformerCheck for 24 Volts from secondary side of transformer. If input to transformer is present and there is
Temperature Controller
(Digital Control Board)
C
FusesCheck for blown fuses
WiringInspect wiring for damage, opens and/or shorts. Inspect ground and wire to wire connections.
Error Code E001 or
E002 on display
D
Over temp indicatorIf griddle is not warming up or holding a set point temperature, cycle power.
E
Confi rm proper voltage at outlet
Plug in power cord
Reset breaker
no output, replace transformer.
If 24VAC is on secondary side of transformer, check power input terminals of Temp Controller J2-1
& J2-2.
If 24VAC is at terminals, replace Temp Controller.
If 24VAC is not at terminals, check for broken wires or poor crimps at the terminals.
Inspect for poor terminal crimps. Inspect power cord.
Note* Unit has a digital controller, if voltages, fuses and wiring appear to be in order, try cycling
power.
E001: Open Temp (RTD) sensor J3-1 & J3-2. Check terminals for poor crimping.
E002: Shorted Temp (RTD) sensor J3-1 & J3-2
If RTD checks good (see page 18), reconnect RTD and cycle power. Is error code still present?
Replace Temperature Controller
Check Over Temp RTD for proper values at current temperature (see page 18).
If temp/resistance values match RTD, replace Over Temp Thermostat.
If values do not match RTD, replace Over Temp RTD.
If Over Temp and Heat light are on and griddle is not warming, cycle power. . If Over Temp light
goes out, monitor griddle to see if it over temps again.
If temperature is greater than 50 degrees different than measurement device, verify measurement
device. If measurement device appears to be accurate, measure RTD.
If RTD measures normally, replace temperature controller.
If RTD measures out of specifi cations, replace RTD.
Heat light not onIf griddle is warming up or regulating at a set point, replace indicator lamp.
F
Unit not heating up
(with heat light on)
G
Inaccurate Temperature If display temperature is greater than 50 degrees different than measurement device, verify
H
If griddle is not warming, check for 24 VDC at SSR terminals. If voltage is present at SSR, replace
SSR.
Check J7-1 and J7-2 at temp controller. If no voltage at output, replace temperature controller.
If 24VDC is not present at SSR(s), check for poor or loose connections, broken red and/ or orange
wires between the “Heat” indicator lamps and the SSR(s). If wiring is correct replace SSR.
If 24VDC is present at SSR(s), check for poor or loose connections between the contactor, elements
and SSR(s). Verify all elements Ohm out equally and the contactor is pulling in.
measurement device. If measurement device appears to be accurate, measure RTD. If RTD measures
normally, replace temperature controller. If RTD measures out of specifi cations (see page 18), replace
RTD.
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
PAGE 11
Page 12
Digital Controller
Minimum Set Temperature: 200ºF
Maximum Set Temperature: 400ºF
Default Set Temperatures: 350ºF
Ambient Temperature: 30 ºF To 158 ºF (0 to 70ºC) operating
Input Voltage: 24 VAC 60HZ +/-10%
Display: 4 digit LED, Clock Style
Mode: On/Off or Proportional
Hysteresis: 2-10 ºF User Programmable
Sensor Probes: PRTD 1000Ω
Unit of Measure: Degree F
Resolution: 1ºF
Power Consumption: 1.2VA
Calibration is factory preset.
ERROR CODES
The control will display error codes for the following conditions:
E001 Displays when controller detects an Open Sensor
E002 Displays when controller detects a Shorted Sensor
To reset from any error, unit must be turned OFF (using S5 or cycling power), repaired, and then turned ON.
When any error is displayed: Output to J7-2 & J7-4 forced open / K2 forced open.
Accu-Steam™ G2 Electric Service Manual
PAGE 12
SP8041-1609
Page 13
Digital Controller
PRESET 1 & 2
To Set Preset Temperature:
To set temperature, press either the UP arrow key or the DOWN arrow key and hold for approximately 3
seconds. The controller will load and display Default Cook Temp and enter set temperature mode.
Press the UP arrow key to increment or the DOWN arrow key to decrement from the current temperature
setting. Once the correct temperature is displayed, and before the fi ve second time out, press and hold the Preset
Temp 1 key or the Preset Temp 2 key to save the displayed value to the desired preset key and to exit this mode.
Press the On/Off key to exit without saving. Default values for Preset 1 = 375°F. Default values for Preset 2 =
400°F
To Set User Lockout Mode (Manager’s Mode):
To Set USER LOCKOUT mode, press and hold the 0/1 key and the TEMP key for approximately 4 seconds
while the controller is ON.
After 4 seconds, the USER LOCKOUT parameter will toggle and the display will show either “Loc” or
“ULoc”. When buttons are released, the controller will store the new USER LOCKOUT parameter value into
NVM.
Factory Reset
Pressing and holding the DOWN arrow key (S4) and the ON/OFF key (S5) for fi ve seconds will reset the
software back to the factory default settings.
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
PAGE 13
Page 14
Main Components and Purpose Refer
ence
Transformer
AT0E-2662-5
3 Pole Contactor (Relay)
AT0E-1587-4
Digital Control Board
AT0E-3625-5
Fuse .75 Amp 250v
AT0E-2731-4
Hi-Limit Control Board
AT0E-3880-1
-Steps down the line voltage to approximately 24VAC
-Receives power from the Hi-Limit Control Board
which will open and close the contactor. When closed
the relay supplies line voltage to the elements and
Solid state relays.
-Provides line voltage to the transformer.
-Receives input signal from RTD Temperature Sensor.
-Regulates griddles temperature by giving 24VDC to
the solid state relays.
-The .75A fuse is to provide protection to the control
circuitry in case of a short in the system.
-Receives input signal from Hi-Limit RTD
temperature sensor and pulls contactor in.
-Releases contactor when unsafe signal is met from
Hi-Limit RTD (approximatively 425° or 182Ω)
Temperature Sensor RTD
AT0E-2885-8
Hi-Limit Temperature Sensor, RTD
AT0E-2885-7
Heat Lamp 24v Red
AT0E-1800-2
Solid State Relay
AT0E-2059-3
Over temp Lamp 24v Red-Receives 24VDC power from Hi-Limit control board
-Digital temperature control board RTD is a 1000Ω
RTD with a black shrink sleeve identifi er.
- The RTDs provide temperature reference
information to the respective controllers. High limit
control RTD is a 100Ω RTD, red heat shrink sleeve
identifi cation.
-Receives 24VDC power from Digital control board
and indicates the solid state relays are energized.
-Solid state relays provide the high voltage/power
switching to the heating elements via the 24VDC
output from the digital control board.
and indicates the griddle has exceeded 425°.
PAGE 14
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 15
Parts Identifi cation, Removal and Installa
tion
Terminal Block
Fuse Block3 Pole Contactor
Transformer
3 Pole Contactor
AT0E-1587-4
1. Unplug from wall receptacle.
2. Lower front access panel by removing the screws in
the upper corners of the panel.
3. Locate contactor and note the location of the wires
and their terminals, disconnect wires.
4. Removed nuts securing contactor.
5. Remove contactor.
6. Reinstall in reverse order.
Temp Control RTD SensorHi-Limit RTD SensorSolid State Relays
Hi-Limit Control
Board
Digital Control
Board
Fuse .75 Amp 250V
AT0E-2731-4
1. Unplug from wall receptacle.
2. Lower front access panel by removing the screws
in the upper corners of the panel.
3. Replace fuse.
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
PAGE 15
Page 16
Parts Identifi cation, Removal and Installa
tion
Digital Control Board
AT0E-3625-5
1. Unplug from wall receptacle.
2. Lower front access panel by removing the screws in
the upper corners of the panel.
3. Locate the main control board. Take note of wires
and their terminals, remove wires.
4. Remove nuts and washers securing board to panel,
remove panel.
5. Reinstall in reverse order.
IMPORTANT NOTICE: Failure to unplug the unit
before pulling wires from the board could result in
fatal damage to the controller board.
Hi-Limit Control Board
AT0E-3880-1
1. Unplug from wall receptacle.
2. Lower front access panel by removing the screws in
the upper corners of the panel.
3. Locate the Hi-Limit control board. Take note of
wires and their terminals, remove wires.
4. Remove nuts and washers securing board to panel,
remove panel.
5. Reinstall in reverse order.
PAGE 16
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 17
Parts Identifi cation, Removal and Installa
tion
Transformer
AT0E-2662-5
1. Unplug from wall receptacle.
2. Lower front access panel by removing the screws in
the upper corners of the panel.
3. Locate transformer and note the location of the
wires and their terminals, disconnect wires.
4. Removed nuts securing transformer.
5. Remove transformer.
6. Reinstall in reverse order.
Heat Lamp 24V Red
Over Temp Lamp 24V Red
AT0E-1800-2
1. Lower front access panel by removing the screws in
the upper corners of the panel.
2. Locate the light bar and remove wires from lamp.
3. Remove nuts securing the lamp to light bar.
4. Remove lamp.
5. Reinstall in reverse order.
Solid State Relay(s)
AT0E-2059-3
1. Unplug from wall receptacle.
2. Lower front access panel by removing the screws in
the upper corners of the panel.
3. Locate the solid state relay (SSR) and remove
screws securing wires to relay.
4. Remove screw securing relay to heat sync plate.
5. Reinstall in reverse order.
NOTE: It is vital to have both mounting screws
install with each relay in order to ensure the relays
have a long life and do not burn out prematurely
from over heating.
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
PAGE 17
Page 18
Parts Identifi cation, Removal and Installa
tion
Temperature Sensor, 1000Ω RTD
AT0E-2885-8
1. Lower front access panel by removing the screws in
the upper corners of the panel.
2. Locate and remove RTD wires attached to the main
control board .
3. Remove nut securing RTD to griddle .
4. Reinstall in reverse order.
Hi-Limit Sensor, 100Ω RTD
AT0E-2885-7
1. Lower front access panel by removing the screws in
the upper corners of the panel.
2. Locate and remove RTD wires attached to the HiLimit control Board.
3. Remove nut securing RTD to griddle .
4. Reinstall in reverse order.
Testing
RTD Resistance Chart
Te mp
70108.221082.25
100114.681146.82300156.911569.101
125120.031200.38325162.081620.883
150125.371253.72350167.241672.442
175130.681306.84375167.241672.442
200135.971359.74400172.371723.778
225141.241412.41425177.481774.892
250146.481464.86450187.641876.451
275151.71517.09475192.681926.897
Hi-Limit Sensor
(100 Ω)
Temp S ens or
(1000 Ω)
Te mp
Hi-Limit Sensor
(100 Ω)
Temp S ens or
(1000 Ω)
PAGE 18
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 19
Preventative Maintenance
PM TASK DESCRIPTION
Verify that the appliance is level and properly located under the hood.
Verify that the temperature controller is working properly, that there are
no rips in the label.
Check that the splash shield at the top of the control panel is under the
rail provided. If not water and or grease can migrate into control panel.
Inspect the control compartment for foreign particulate and any loose
wiring or connections.
Check that the power supply cord is not frayed, outer covering is not
degraded or any bare cooper is visible. Replace if required.
Verify amp draw to listed amp requirements on the data tag of the appliance.
If on an AccuTemp Stand verify mounting fasteners are in place and
tight. If not correct. If the stand has casters check that the wheels are
intact and that they mounted correctly. If grease covered clean with a
mild detergent and clean water. Dry completely . Apply a food grade
silicone to the locking mechanism.
DailyBiannualYearly
XX
XXX
XX
XX
XXX
XX
XXX
Complete a 9 point temperature test to check for even temperature across
the surface of the cooking surface.
Check for grease buildup in the grease drawer container and clean it with
a damp towel saturated with a mild detergent and clean water. Dry with a
clean dry towel.
After all metallic areas are cool to the touch Clean external metal
surfaces except the cooking surface. with a damp clean towel saturated
with a mild detergent and clean water. Dry with a clean dry towel.
Season the cooking surface as as outlined in this manual.
XX
XXX
XXX
X
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
PAGE 19
Page 20
A
Rev.
R3
R2
R1
2
3
6
1
4
1
2
WHT
HEATING ELEMENTS
4
3
BLK
RED
(+)
3/A1
T1
5
BLK
ORN
(-)
4/A2
AT2T-3912-2
SSR 1
L1
BLK
1 2
PRTD
1000O
-ELECTRIC -)
1Ø 208V-240V
(MODULAR GRIDDLE
J3
INPUT
SENSOR
DIGITAL
8415 N. Clinton Park
Fort Wayne, IN 46825
AccuTemp Products, Inc.
G2 GRIDDLE
SCHEMATIC,
AT2T-3912
CONTROLLER
GRY
J7
ON/
WHT/GRAY
ORN
1 2 3 4 5 6
YEL
J2
1 2
VIO
VIO
WHT/BRN
OFF
GND
+24V
INPUT
POWER
CONTACTOR
ZR2
275V
100 O
BLK
WHT
BRN
30V
L3
L1
L2
BLK
WHT
BLK
WHT
WHT
ZR1
YEL
VIO
YEL
GRN
1
2
3
4
J1
PRTD
HIGH LIMIT
CONTROLLER
L1 L2 N.C. N.O. COM *RTD* RESET
BRN
TEMP
WHT/BRN
YEL
VIO
.75 A
F
2
.75 A
F
1
VIO
24V
YEL
OVER
RED
HEAT
COM
208
240
440
480
AT0A-2662-5
PAGE 20
GRN
TIMER
REMOTE
OPTIONAL
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 21
A
Rev.
R3
HEATING ELEMENTS
3
2
1
WHT
5
4
6
1
2
BLK
4
3
RED
RED
(-)
(+)
4/A2
3/A1
SSR 2
L1
T1
RED
RED
ORN
(+)
4/A2
3/A1
SSR 1
T1
BLK
ORN
(-)
AT2T-3912-3
-ELECTRIC -)
3Ø 208V-240V
(MODULAR GRIDDLE
L1
BLK
J3
1 2
PRTD
1000O
INPUT
SENSOR
DIGITAL
8415 N. Clinton Park
Fort Wayne, IN 46825
AccuTemp Products, Inc.
G2 GRIDDLE
SCHEMATIC,
AT2T-3912
CONTROLLER
GRY
J7
ON/
WHT/GRAY
ORN
1 2 3 4 5 6
YEL
J2
1 2
VIO
VIO
WHT/BRN
OFF
GND
+24V
INPUT
POWER
ZR2
WHT
275V
100 O
YEL
PRTD
HIGH LIMIT
CONTROLLER
L1 L2 N.C. N.O. COM *RTD* RESET
BRN
TEMP
WHT/BRN
VIO
.75 A
F
2
.75 A
F
1
VIO
24V
YEL
OVER
RED
HEAT
COM
208
240
440
480
AT0A-2662-5
BLK
BRN
30V
L1
BLK
BLK
X
G
Y
Z
ZR1
YEL
VIO
YEL
GRN
1
2
3
4
J1
GRN
TIMER
REMOTE
OPTIONAL
ZR5
275V
RED
WHT
L3
RED
L2
WHT
WHT
CONTACTOR
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
PAGE 21
Page 22
A
Rev.
R3
RED
HEATING ELEMENTS
3
2
1
WHT
5
2
3
RED
BLK
4
4
16
(-)
(+)
4/A2
3/A1
SSR 2
L1
T1
RED
RED
RED
ORN
ORN
(-)
(+)
4/A2
3/A1
AT2T-3912-4
SSR 1
L1
T1
BLK
J3
1 2
PRTD
1000O
-ELECTRIC -)
3Ø 440V-480V
(MODULAR GRIDDLE
INPUT
SENSOR
DIGITAL
8415 N. Clinton Park
Fort Wayne, IN 46825
AccuTemp Products, Inc.
G2 GRIDDLE
SCHEMATIC,
AT2T-3912
CONTROLLER
GRY
J7
ON/
WHT/GRAY
ORN
1 2 3 4 5 6
YEL
J2
1 2
VIO
VIO
WHT/BRN
OFF
GND
+24V
INPUT
POWER
ZR2
WHT
Y
275V
100 O
YEL
PRTD
HIGH LIMIT
CONTROLLER
L1 L2 N.C. N.O. COM *RTD* RESET
BRN
TEMP
WHT/BRN
VIO
.75 A
F
2
.75 A
F
1
VIO
24V
YEL
OVER
RED
HEAT
COM
208
240
440
480
AT0A-2662-5
BLK
BRN
30V
L1
BLK
BLK
X
G
Z
ZR1
YEL
VIO
YEL
GRN
1
2
3
4
J1
GRN
TIMER
REMOTE
OPTIONAL
ZR5
275V
RED
WHT
L3
CONTACTOR
L2
WHT
RED
WHT
PAGE 22
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
Page 23
A
Rev.
R3
RED
HEATING ELEMENTS
(-)
(+)
4/A2
3/A1
4
3
2
1
WHT
5
2
4
3
16
RED
BLK
SSR 2
L1
T1
RED
RED
ORN
(+)
3/A1
SSR 1
T1
BLK
RED
ORN
(-)
4/A2
AT2T-3912-5
3Ø 380V-415V
-ELECTRIC)
(MODULAR GRIDDLE
L1
BLK
J3
1 2
PRTD
1000O
INPUT
SENSOR
DIGITAL
8415 N. Clinton Park
Fort Wayne, IN 46825
AccuTemp Products, Inc.
G2 GRIDDLE
SCHEMATIC,
AT2T-3912
CONTROLLER
GRY
J7
ON/
WHT/GRAY
ORN
1 2 3 4 5 6
YEL
J2
1 2
VIO
VIO
WHT/BRN
OFF
GND
+24V
INPUT
POWER
ZR2
ZR5
275V
RED
WHT
L3
CONTACTOR
L2
275V
100 O
BLK
BRN
30V
L1
ZR1
PRTD
HIGH LIMIT
CONTROLLER
YEL
BLK
RED
WHT
BLK
WHT
L1 L2 N.C. N.O. COM *RTD* RESET
BRN
TEMP
OVER
WHT/BRN
RED
VIO
YEL
HEAT
.75 A
F
2
.75 A
F
1
VIO
VIO
YEL
GRN
1
2
3
4
WHT
L2
L3
L1
N
G
GRN/YEL
J1
TIMER
REMOTE
OPTIONAL
YEL
COM
208
240
24V
440
480
AT0A-2662-5
h
r
c
1
6
,
2
0
1
6
9
:
2
3
:
5
4
M
e
:
S
i
D
e
W
G
t
z
d
n
d
e
a
s
y
,
E
T
V
L
S
A
A
S
M
A
a
Accu-Steam™ G2 Electric Service Manual
SP8041-1609
PAGE 23
Page 24
Product Warranty
U.S. & Canada Sales Only
LIMITED WARRANTY
One Year Parts and LaborOne Year Parts and Labor
AccuTemp Products, Inc. ( AccuTemp ) warrants that your AccuTemp equipment will be free of defects in material and
workmanship under normal use for a period of twelve (12) months from installation or fi fteen (15) months from date of
shipment from AccuTemp, whichever date fi rst occurs (the Warranty Period ). Registration of AccuTemp equipment is
required at time
of installation.
Damage to AccuTemp equipment that occurs during shipment must be reported to the carrier, and is not covered under this
warranty. The reporting of any damage during shipment is the sole responsibility of the commercial purchaser/user of such
AccuTemp equipment.
AccuTemp provides an active service department, which should be contacted and advised of service issues regardless of
warranty period.
During the warranty period, AccuTemp agrees to repair or replace, at its option, F.O.B. factory, any part which proves to
be defective due to defects in material or workmanship, provided the equipment has not been altered in any way and has
been properly installed, maintained, and operated in accordance with the instructions in the AccuTemp Owners Manual.
During the warranty period, AccuTemp also agrees to pay for any factory authorized equipment service agency (within
the continental United States and Canada) for reasonable labor required to repair or replace, at our option, F.O.B. factory,
any part which proves to be defective due to defects in materials or workmanship, provided the service agency has
received advance approval from AccuTemp factory service to perform the repair or replacement. This warranty includes
travel time not to exceed two hours and mileage not to exceed 50 miles (100 miles round trip), but does not include post
start-up assistance or training, tightening of loose fi ttings or external electrical connections, minor adjustments, gaskets,
maintenance, or cleaning. AccuTemp will not reimburse the expense of labor required to replace parts after the expiration
of the warranty period.
Proper installation is the responsibility of the dealer, owner-user, or installing contractor and is not covered by this
warranty. While AccuTemp products are built to comply with applicable standards for manufacturers, including
Underwriters Laboratories (UL) and National Sanitation Foundation (NSF), it is the responsibility of the owner and the
installer to comply with any applicable local codes that may exist.
AccuTemp makes no other warranties or guarantees, whether expressed or implied, including any warranties of
performance, merchantability, or fi tness for any particular purpose. AccuTemp s liability on any claim of any kind,
including negligence, with respect to the goods and services covered hereunder, shall in no case exceed the price of the
goods and services, or parts thereof, which gives rise to the claim. In no event shall AccuTemp be liable for special,
incidental, or consequential damages, or damages in the nature of penalties.
This constitutes the entire warranty, which supersedes and excludes all other warranties, whether written, oral, or implied.
IMPORTANT
Improper installation can a ect your warranty. Installation is the responsibility of the Dealer, Owner/
User or the Installation Contractor. See: Section One, Installation of the Owner s Manual.
For Service Call 800-480-0415 or email: service@accutemp.net
Accu-Steam™ G2 Electric Service Manual
PAGE 24
SP8041-1609