Improper installation, alteration,
adjustment,service, cleaning or maintenance
of this commercial appliance could result in
property damage, serious injury or death.
Read and understand the installation,
operational, maintenance instructions
before installing, servicing, or operating this
commercial appliance.
MP5018-1605
AccuTemp Products, Inc. · 8415 North Clinton Park · Fort Wayne, IN 46825 ·800 210-5907 · accutemp.net
Record the serial number and model number
(identication decal located on the left side of the
front panel ) voltage and the install date. Please
have this information when calling for assistance.
Symbols are used to attract your attention to possible dangers. They are only effective if the
operator uses proper accident prevention measures. Some of the symbols are boxed text, while
other maybe just picture icons. Please give this information the respect they deserve for safe
operation.
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in minor or moderate injury.
ALERT - Noties the reader of an important message/warning,
usually a safety related message.
Earth Ground
Dangerous Voltage
INFORMATION - Noties the reader of important information that
may or may not be safety related.
MP5018-1605
Caution Hot Surface
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 2
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT: Read the following safety installation to avoid personal injury or death and to avoid
damage to the equipment or property
WARNINGS
Plug commercial appliance into a properly
grounded electrical outlet of the correct
voltage, size and plug conguration. If they
do not match, contact a qualied electrician
to determine the proper voltage and size and
install the proper electrical outlet.
To avoid any personal injury or damage to
the unit do not pull the commercial appliance
by the power cord.
To prevent any injury, discontinue any use if
power cord is frayed or worn.
To prevent any injury or damage this
commercial appliance must be installed by a
qualied electrician.
To avoid any injury, turn the power off, unplug
from the power source and allow to cool
before performing any maintenance.
To avoid electrical shock or personal injury,
do not steam clean or use excessive water
on this commercial appliance.
This product has no “user” serviceable parts.
To avoid injury or damage to the commercial
appliance use only Authorized AccuTemp
Service Agents and Genuine Replacement
Parts when service is required.
Genuine AccuTemp Replacement Parts
are specied to operate safely in the
environments in which they are used. Some
aftermarket parts or generic replacements
parts do not have the same specications to
operate safely in AccuTemp equipment. It is
imperative that to use Genuine AccuTemp
Replacement Parts to avoid injury or damage
to the commercial appliance.
Always disconnect from power source before
cleaning or servicing.
Any ineld modication that bypass the built-
in safety features will result in personal injury
or death.
This commercial appliance must be properly
grounded, in accordance with all National,
State or local electrical codes.
This commercial appliance has a totally
unique design and is constructed unlike
any other griddle on the market today. Any
modication may permanently damage the
griddle.
CAUTIONS
This commercial appliance must be level
for proper operation and to reduce possible
damage to this commercial appliance.
This commercial appliance is heavy, for
safe handling, the installer should obtain
help as needed or employ appropriate
material handling equipment to remove the
commercial appliance from the skid and
move to the nal location in the building.
Temperatures in and around the commercial
appliance are very hot and can cause severe
burns.
To avoid damage to the cooking surface
of this commercial appliance do not use
abrasive cleaners such as a griddle stone or
brick.
To avoid personal injury or damage to the
commercial appliance do not use a water jet
to clean this commercial appliance.
To avoid damage to the commercial
appliance do not leave a chlorine sanitizer in
contact with the stainless steel longer than
10 minutes.
To avoid severe burns slowly remove
the grease reservoir to avoid spilling the
contents. It is recommended to let it cool
before removing.
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 3
Product Warranty
U.S. & Canada Sales Only
LIMITED WARRANTY
One Year Parts and LaborOne Year Parts and Labor
AccuTemp Products, Inc. ( AccuTemp ) warrants that your AccuTemp equipment will be free of defects in
material and workmanship under normal use for a period of twelve (12) months from installation or fteen (15)
months from date of shipment from AccuTemp, whichever date rst occurs (the Warranty Period ). Registration
of AccuTemp equipment is required at time
of installation.
Damage to AccuTemp equipment that occurs during shipment must be reported to the carrier, and is not
covered under this warranty. The reporting of any damage during shipment is the sole responsibility of the
commercial purchaser/user of such AccuTemp equipment.
AccuTemp provides an active service department, which should be contacted and advised of service issues
regardless of warranty period.
During the warranty period, AccuTemp agrees to repair or replace, at its option, F.O.B. factory, any part which
proves to be defective due to defects in material or workmanship, provided the equipment has not been altered
in any way and has been properly installed, maintained, and operated in accordance with the instructions in the
AccuTemp Owners Manual.
During the warranty period, AccuTemp also agrees to pay for any factory authorized equipment service agency
(within the continental United States and Canada) for reasonable labor required to repair or replace, at our
option, F.O.B. factory, any part which proves to be defective due to defects in materials or workmanship,
provided the service agency has received advance approval from AccuTemp factory service to perform the
repair or replacement. This warranty includes travel time not to exceed two hours and mileage not to exceed
50 miles (100 miles round trip), but does not include post start-up assistance or training, tightening of loose
ttings or external electrical connections, minor adjustments, gaskets, maintenance, or cleaning. AccuTemp will
not reimburse the expense of labor required to replace parts after the expiration of the warranty period.
Proper installation is the responsibility of the dealer, owner-user, or installing contractor and is not covered
by this warranty. While AccuTemp products are built to comply with applicable standards for manufacturers,
including Underwriters Laboratories (UL) and National Sanitation Foundation (NSF), it is the responsibility of
the owner and the installer to comply with any applicable local codes that may exist.
AccuTemp makes no other warranties or guarantees, whether expressed or implied, including any warranties
of performance, merchantability, or tness for any particular purpose. AccuTemp s liability on any claim of any
kind, including negligence, with respect to the goods and services covered hereunder, shall in no case exceed
the price of the goods and services, or parts thereof, which gives rise to the claim. In no event shall AccuTemp
be liable for special, incidental, or consequential damages, or damages in the nature of penalties.
This constitutes the entire warranty, which supersedes and excludes all other warranties, whether written, oral,
or implied.
IMPORTANT
Improper installation can affect your warranty. Installation is the responsibility of the Dealer, Owner/
User or the Installation Contractor. See: Section One, Installation of the Owner s Manual.
For Service Call 800-480-0415 or email: service@accutemp.net
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
Griddle shall be an Energy Star compliant
gas-heated unit, with a hermetically
sealed vacuum chamber that produces
steam that heats the 7-gauge stainless
steel griddle plate. Efficient steam heat
transfer provides 200–400°F (93–204°C)
operating temperature range and uniform
griddle surface temperatures of ±5°F
(±3°C). Griddle fabricated from cold-rolled
stainless steel with 4” high back splash,
sides that taper from 4” to 1 5/16”, a 3 7/8”
wide by ½” deep full front grease trough
and 1 ¼ - 1 5/8 gallon grease drawer. Unit
to be UL listed, UL EPH Sanitation Certified
(NSF/ANSI 4) and manufactured in the
USA.
Construction Features
• Cold-rolled and annealed stainless steel
griddle plate with polished stainless
steel body
• 7 gauge griddle plate with 4” high rear
splash and 4” to 1 5/16” tapered side
walls
• 3 7/8” wide by ½” deep full front grease
trough
• 2” x 4” drop chute to 1.25 [24”], 1.6 [36”,
48”] gallon capacity grease pan
• 9.6-kW [24”] or 14.25-kW [36”, 48”]
total power, long-life low watt density
heating elements mounted inside
vacuum chamber and immersed in
chemically pure water (Water never
needs replacement)
• Steam transfers heat evenly to entire
cooking surface with only ±5°F (±3°C) in
temperature variation
• Rapid surface temperature recovery [10
seconds or less] allows turning product
to same spot
Griddle shall be an Energy Star compliant
gas-heated unit, with a hermetically
sealed vacuum chamber that produces
steam that heats the 7-gauge stainless
steel griddle plate. Efficient steam heat
transfer provides 200–400°F (93–204°C)
operating temperature range and uniform
griddle surface temperatures of ±5°F
(±3°C). Griddle fabricated from cold-rolled
stainless steel with 4” high back splash,
sides that taper from 4” to 1 5/16”, a 3 7/8”
wide by ½” deep full front grease trough
and 1 ¼ - 1 5/8 gallon grease drawer. Unit
to be UL listed, UL EPH Sanitation Certified
(NSF/ANSI 4) and manufactured in the
USA.
Construction Features
• Cold-rolled and annealed stainless steel
griddle plate with polished stainless
steel body
• 7 gauge griddle plate with 4” high rear
splash and 4” to 1 5/16” tapered side
walls
• 3 7/8” wide by ½” deep full front grease
trough
• 2” x 4” drop chute to 1.25 [24”], 1.6 [36”,
48”] gallon capacity grease pan
• 9.6-kW [24”] or 14.25-kW [36”, 48”]
total power, long-life low watt density
heating elements mounted inside
vacuum chamber and immersed in
chemically pure water (Water never
needs replacement)
• Steam transfers heat evenly to entire
cooking surface with only ±5°F (±3°C) in
temperature variation
• Rapid surface temperature recovery [10
seconds or less] allows turning product
to same spot
8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net
MP5018-1605
AccuTemp Products, Inc.
Accu-Steam™ G2 Electric Installation and Operators Manual
MM5205-1605
PAGE 8
To register this AccuTemp product for warranty complete the following items:
1. Complete the Installation/Operational Checklist and Warranty Registration Form on pages 10-11
2. Mail, fax or scan and e-mail the form to AccuTemp Products, Inc to the contacts listed for each
type on the form.
If you have any questions about warranty registration please contact our technical service group.
They are available 7 days a week from 7:00 am to 7:00 PM EST.
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 9
YesNo
YesNo
YesNo
YesNoYesNo
YesNo
YesNo
15-50P
L16-20P
L16-30P
Store/Location:
Address:
Phone Number:
Fax Number:
Check-Off List
Model #
Serial #
Name of Service/Installer Company:
Is the correct NEMA Plug and Receptacle being used on the Supply Power Cord?
General :
Is the electrical wall receptacle positioned in a low heat-zone?
Note: It is recommended that the wall receptacle be
placed as low as State & Local codes allow. Placement in high heat-zones could cause damage to the electrical cord or plug
that would not be covered under the product warranty.
Is the griddle level, both side-to-side and front-to-back?
If this is a table-top installation, have the (4) rubber foot tip/boots been installed?
Electrical Connection :
Is the Supply Power Cord being plugged into a
wall outlet?
Is the Supply Power Cord being hardwired, without the plug, to a breaker box?
Is the Supply Power Cord properly connected to GND?
208/240VAC (All Models)
440/480VAC (24" Models)
440/480VAC (36" & 48" Models)
Type of NEMA Plug?
Installation/Operational Checklist &
Warranty Registration Form
ELECTRIC - ACCU-STEAM™
Failure to accurately complete and provide this Installation/Operational Checklist & Warranty
Registration Form to AccuTemp Products, may delay or void future Warranty Service Calls.
** AccuTemp Products, Inc. is not responsible for the installation and/or modifications to the electrical supply source. **
What is the Electrical Breaker Amperage that will interupt the Supply Voltage to the electric griddle?
AMPS
City:
State:
Zip:
Email:
Technician:
Phone Number:
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 10
Single Φ
Supply Power Electrical Readings :
Temperature & Operational Verification :
I accept and submit this Installation/Operational Checklist & Warranty Registration Form as complete and accurate:
Restaurant/Facility Manager Approval:
Signature
Printed Name
Date:
Note: If the operating temperature is 250°F, then set Thermostat to 300°F and verify surface temperature. If the operating
Page: 2
Measured Amperage on
Mail
Fax
Email
Installation/Operational Checklist &
Warranty Registration Form
ELECTRIC - ACCU-STEAM™
Does the Supply Electrcial Power match the information on the griddle model number?
Phase (Φ)?
Measured Supply
Voltage?
Each Leg?
What is the customer's normal operating Thermostat temperature for the Griddle?
Note:DO NOT use an infrared or flat-top mercury thermometer.
Using a weighted contact temperature probe with digital thermometer, does the surface temperature (°F)
match the normal operating temperature (°F) set on the Thermostat?
temperature is 400°F, then set Thermostat to 400°F and verify surface temperature does not exceed 396°F on the high side
of the temperature drift/cycle.
Using a 9 square-grid-pattern on the griddle surface, are the surface temperatures consistant (±5°F)?
Does the Griddle heat light cycle OFF/ON once the surface temperature has reached the Thermostat setting?
1Φ =
208VAC240VAC440VAC480VAC
WHT BLK3Φ = RED WHT BLK
YesNo
Three Φ
°F
YesNo
YesNo
YesNo
Does the unit operate properly for 15 minutes after the griddle has reached operating temperature?
AccuTemp Products, Inc
Attn: Warranty Administration
Attn: Warranty Administration
260 469-3045
Attn: Warranty Administration
8415 North Clinton Park Dr.
Fort Wayne, IN 46825
YesNo
service@accutemp.net
MP5004-1401
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 11
MODEL G2 ELECTRIC EGF SERIES
TABLE TOP & STAND
INSTALLATION INSTRUCTIONS
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 12
Loading...