AccuTemp EGF36A Installation Manual

INSTALLATION/OPERATORS MANUAL
ACCU-STEAM ELECTRIC G2 GRIDDLE
MODELS
EGF24A
EGF36A
EGF48A
EGF24B
EGF36B
EGF48B
WARNING
Improper installation, alteration, adjustment,service, cleaning or maintenance of this commercial appliance could result in property damage, serious injury or death.
MP5018-1605 AccuTemp Products, Inc. · 8415 North Clinton Park · Fort Wayne, IN 46825 ·800 210-5907 · accutemp.net
Record the serial number and model number
(identication decal located on the left side of the
front panel ) voltage and the install date. Please have this information when calling for assistance.
Serial Number:
Model:
Install Date:
NOTE
TABLE OF CONTENTS
DESCRIPTION PAGE Document History 1 Safety Warnings 2-3 Specications 4-7 Limited Warranty Policy 8 Warranty Registration Instructions 9 Installation/Operational Checklist & Warranty Registration Form 10-11 Installation Instructions 12-14 Operation Instructions 15-24 Cleaning Instructions 25-26 Planned Maintenance 27-28 Service & Troubleshooting 29-31 Schematics 32-36 Important Contact Information 37
DOCUMENT HISTORY
Current Revision Date Prior Revision Date
MP5018-1605 05/12/2016 N/A
SAFETY WARNINGS
SYMBOL DEFINITIONS
Symbols are used to attract your attention to possible dangers. They are only effective if the operator uses proper accident prevention measures. Some of the symbols are boxed text, while other maybe just picture icons. Please give this information the respect they deserve for safe operation.
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in minor or moderate injury.
ALERT - Noties the reader of an important message/warning,
usually a safety related message.
Earth Ground
Dangerous Voltage
INFORMATION - Noties the reader of important information that
may or may not be safety related.
MP5018-1605
Caution Hot Surface
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 2
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT: Read the following safety installation to avoid personal injury or death and to avoid damage to the equipment or property
WARNINGS
Plug commercial appliance into a properly grounded electrical outlet of the correct
voltage, size and plug conguration. If they do not match, contact a qualied electrician
to determine the proper voltage and size and install the proper electrical outlet.
To avoid any personal injury or damage to the unit do not pull the commercial appliance by the power cord.
To prevent any injury, discontinue any use if power cord is frayed or worn.
To prevent any injury or damage this commercial appliance must be installed by a
qualied electrician.
To avoid any injury, turn the power off, unplug from the power source and allow to cool before performing any maintenance.
To avoid electrical shock or personal injury, do not steam clean or use excessive water on this commercial appliance.
This product has no “user” serviceable parts. To avoid injury or damage to the commercial appliance use only Authorized AccuTemp Service Agents and Genuine Replacement Parts when service is required.
Genuine AccuTemp Replacement Parts
are specied to operate safely in the
environments in which they are used. Some aftermarket parts or generic replacements
parts do not have the same specications to
operate safely in AccuTemp equipment. It is imperative that to use Genuine AccuTemp Replacement Parts to avoid injury or damage to the commercial appliance.
Always disconnect from power source before cleaning or servicing.
Any ineld modication that bypass the built-
in safety features will result in personal injury or death.
This commercial appliance must be properly grounded, in accordance with all National, State or local electrical codes.
This commercial appliance has a totally unique design and is constructed unlike any other griddle on the market today. Any
modication may permanently damage the
griddle.
CAUTIONS
This commercial appliance must be level for proper operation and to reduce possible damage to this commercial appliance.
This commercial appliance is heavy, for safe handling, the installer should obtain help as needed or employ appropriate material handling equipment to remove the commercial appliance from the skid and
move to the nal location in the building.
Temperatures in and around the commercial appliance are very hot and can cause severe burns.
To avoid damage to the cooking surface of this commercial appliance do not use abrasive cleaners such as a griddle stone or brick.
To avoid personal injury or damage to the commercial appliance do not use a water jet to clean this commercial appliance.
To avoid damage to the commercial appliance do not leave a chlorine sanitizer in contact with the stainless steel longer than 10 minutes.
To avoid severe burns slowly remove the grease reservoir to avoid spilling the contents. It is recommended to let it cool before removing.
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 3
Product Warranty
U.S. & Canada Sales Only
LIMITED WARRANTY
One Year Parts and LaborOne Year Parts and Labor
AccuTemp Products, Inc. ( AccuTemp ) warrants that your AccuTemp equipment will be free of defects in
material and workmanship under normal use for a period of twelve (12) months from installation or fteen (15) months from date of shipment from AccuTemp, whichever date rst occurs (the Warranty Period ). Registration
of AccuTemp equipment is required at time of installation.
Damage to AccuTemp equipment that occurs during shipment must be reported to the carrier, and is not covered under this warranty. The reporting of any damage during shipment is the sole responsibility of the commercial purchaser/user of such AccuTemp equipment.
AccuTemp provides an active service department, which should be contacted and advised of service issues regardless of warranty period.
During the warranty period, AccuTemp agrees to repair or replace, at its option, F.O.B. factory, any part which proves to be defective due to defects in material or workmanship, provided the equipment has not been altered in any way and has been properly installed, maintained, and operated in accordance with the instructions in the AccuTemp Owners Manual.
During the warranty period, AccuTemp also agrees to pay for any factory authorized equipment service agency (within the continental United States and Canada) for reasonable labor required to repair or replace, at our option, F.O.B. factory, any part which proves to be defective due to defects in materials or workmanship, provided the service agency has received advance approval from AccuTemp factory service to perform the repair or replacement. This warranty includes travel time not to exceed two hours and mileage not to exceed 50 miles (100 miles round trip), but does not include post start-up assistance or training, tightening of loose
ttings or external electrical connections, minor adjustments, gaskets, maintenance, or cleaning. AccuTemp will
not reimburse the expense of labor required to replace parts after the expiration of the warranty period.
Proper installation is the responsibility of the dealer, owner-user, or installing contractor and is not covered by this warranty. While AccuTemp products are built to comply with applicable standards for manufacturers, including Underwriters Laboratories (UL) and National Sanitation Foundation (NSF), it is the responsibility of the owner and the installer to comply with any applicable local codes that may exist.
AccuTemp makes no other warranties or guarantees, whether expressed or implied, including any warranties
of performance, merchantability, or tness for any particular purpose. AccuTemp s liability on any claim of any
kind, including negligence, with respect to the goods and services covered hereunder, shall in no case exceed the price of the goods and services, or parts thereof, which gives rise to the claim. In no event shall AccuTemp be liable for special, incidental, or consequential damages, or damages in the nature of penalties.
This constitutes the entire warranty, which supersedes and excludes all other warranties, whether written, oral, or implied.
IMPORTANT
Improper installation can affect your warranty. Installation is the responsibility of the Dealer, Owner/ User or the Installation Contractor. See: Section One, Installation of the Owner s Manual.
For Service Call 800-480-0415 or email: service@accutemp.net
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 4
Accu-SteAm™ Griddle eG SerieS
Electric/Steam-Heated, Tabletop Griddle
Project: ___________________________________ Location: ___________________________________ Item #: ___________________________________ Quantity:___________
Short Specification
Griddle shall be an Energy Star compliant gas-heated unit, with a hermetically sealed vacuum chamber that produces steam that heats the 7-gauge stainless steel griddle plate. Efficient steam heat transfer provides 200–400°F (93–204°C) operating temperature range and uniform griddle surface temperatures of ±5°F (±3°C). Griddle fabricated from cold-rolled stainless steel with 4” high back splash, sides that taper from 4” to 1 5/16”, a 3 7/8” wide by ½” deep full front grease trough and 1 ¼ - 1 5/8 gallon grease drawer. Unit to be UL listed, UL EPH Sanitation Certified (NSF/ANSI 4) and manufactured in the USA.
Construction Features
• Cold-rolled and annealed stainless steel griddle plate with polished stainless steel body
• 7 gauge griddle plate with 4” high rear splash and 4” to 1 5/16” tapered side walls
• 3 7/8” wide by ½” deep full front grease trough
• 2” x 4” drop chute to 1.25 [24”], 1.6 [36”, 48”] gallon capacity grease pan
• 4” legs with bullet feet
• Control guard
Performance Features
• Hermetically-sealed steam chamber heats griddle plate
• 9.6-kW [24”] or 14.25-kW [36”, 48”] total power, long-life low watt density heating elements mounted inside vacuum chamber and immersed in chemically pure water (Water never needs replacement)
• Steam transfers heat evenly to entire cooking surface with only ±5°F (±3°C) in temperature variation
• Rapid surface temperature recovery [10 seconds or less] allows turning product to same spot
• Smooth cold-rolled stainless steel griddle surface speeds and simplifies cleaning
Standard Control Features
• Heating indicator light
• 200–400°F (93–204°C) digital thermostat
• Easy front service access to controls
• Control guard
• 3 preset temperatures available
• Instant surface temperature readout
• Manager mode to lock out temperature controls
• Over temperature indicator light
Cooking Capacity & Applications
Effective Cooking Area
Depth 24” Wide 36” Wide 48” Wide
30” 717 sq. in 1077 sq. in. 1437 sq. in.
24” 574 sq. in. 862 sq. in. 1150 sq. in.
Griddle Applications include:
• Pancakes, Eggs, Sausage, French Toast
• Burgers, Grilled Onions, Toasted Buns
• Grilled Cheese, Sandwiches
• Fried Potatoes, Fish, Chicken Breasts, Philly Steaks, Liver and MORE
Environmental Approvals & Programs
Other Approvals
NSF/ANSI 4
Options & Accessories
• “U” Channel for connecting 2 griddles
• Front mounted prep shelf—8” wide stainless steel
• Condiment Board
• Maritime Package (call for details)
• Correction Package (call for details)
• Chain Package (call for details)
• Heavy duty stainless steel stand with bottom shelf and 5” casters
EGF-A36 Accu-Steam™
Tabletop Griddle shown
8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net
MP5018-1605
AccuTemp Products, Inc.
Accu-Steam™ G2 Electric Installation and Operators Manual
MM5206-1605
PAGE 5
Accu-Steam Griddle Specifications (replace **** with voltage & phase, i.e. 2083)
Model #
KW Input
208/3 Amp Load
240/1 Amp Load
240/3 Amp Load
440/3 Amp Load
480/3 Amp Load
Unit Width (A)
Unit Depth (D)
Cooking Surface Width (B)
Cooking Surface Depth (C)
Depth to Rear Leg (E)
Center right to left (F)
Effective Cooking Area
Grease Pan Capacity
NEMA Plug (208/240)
NEMA Plug (440/480)
Accu-SteAm™ Griddle eG SerieS
Electric/Steam-Heated, Tabletop Griddle
EGF****A2400-T1 EGF****B2400-T1 EGF****A3600-T1 EGF****B3600-T1 EGF****A4800-T1 EGF****B4800-T1
9.6 kW 9.6 kW 14.25 kW 14.25 kW 14.25 kW 14.25 kW
27 27 40 40 40 40
40 40 n/a n/a n/a n/a
24 24 35 35 35 35
15 15 21 21 21 21
16 16 23 23 23 23
24.25 [616] 24.25 [616] 36.25 [921] 36.25 [921] 48.25 [1226] 48.25 [1226]
34.7 [881] 28.7 [729] 34.7 [881] 28.7 [729] 34.7 [881] 28.7 [729]
23.9 [607] 23.9 [607] 35.9 [912] 35.9 [912] 47.9 [1217] 47.9 [1217]
30 [762] 24 [610] 30 [762] 24 [610] 30 [762] 24 [610]
8.5 [216] 2.5 [64] 8.5 [216] 2.5 [64] 8.5 [216] 2.5 [64]
20 [508] 20 [508] 32 [813] 32 [813] 44 [1117] 44 [1117]
717 sq. in. 574 sq. in. 1077 sq. in. 862 sq. in. 1437 sq. in. 1150 sq. in.
1.25 gal 1.25 gal 1.6 gal 1.6 gal 1.6 gal 1.6 gal
15-50P 15-50P 15-50P 15-50P 15-50P 15-50P
L16-20P L16-20P L16-30P L16-30P L16-30P L16-30P
Notes:
1.) Dimensions in brackets [ ] are metric.
2.) 5’ power cord wtih plug provided.
8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net
MP5018-1605
AccuTemp Products, Inc.
Accu-Steam™ G2 Electric Installation and Operators Manual
MM5206-1605
PAGE 6
Accu-SteAm™ Griddle eG SerieS
Electric/Steam-Heated, Stand-Mounted Griddle
Project: ___________________________________ Location: ___________________________________ Item #: ___________________________________ Quantity:___________
Short Specification
Griddle shall be an Energy Star compliant gas-heated unit, with a hermetically sealed vacuum chamber that produces steam that heats the 7-gauge stainless steel griddle plate. Efficient steam heat transfer provides 200–400°F (93–204°C) operating temperature range and uniform griddle surface temperatures of ±5°F (±3°C). Griddle fabricated from cold-rolled stainless steel with 4” high back splash, sides that taper from 4” to 1 5/16”, a 3 7/8” wide by ½” deep full front grease trough and 1 ¼ - 1 5/8 gallon grease drawer. Unit to be UL listed, UL EPH Sanitation Certified (NSF/ANSI 4) and manufactured in the USA.
Construction Features
• Cold-rolled and annealed stainless steel griddle plate with polished stainless steel body
• 7 gauge griddle plate with 4” high rear splash and 4” to 1 5/16” tapered side walls
• 3 7/8” wide by ½” deep full front grease trough
• 2” x 4” drop chute to 1.25 [24”], 1.6 [36”, 48”] gallon capacity grease pan
• 4” legs with bullet feet
• Control guard
Performance Features
• Hermetically-sealed steam chamber heats griddle plate
• 9.6-kW [24”] or 14.25-kW [36”, 48”] total power, long-life low watt density heating elements mounted inside vacuum chamber and immersed in chemically pure water (Water never needs replacement)
• Steam transfers heat evenly to entire cooking surface with only ±5°F (±3°C) in temperature variation
• Rapid surface temperature recovery [10 seconds or less] allows turning product to same spot
• Smooth cold-rolled stainless steel griddle surface speeds and simplifies cleaning
Standard Control Features
• Heating indicator light
• 200–400°F (93–204°C) digital thermostat
• Easy front service access to controls
• Control guard
• 3 preset temperatures available
• Instant surface temperature readout
• Manager mode to lock out temperature controls
• Over temperature indicator light
Cooking Capacity & Applications
Effective Cooking Area
Depth 24” Wide 36” Wide 48” Wide
30” 717 sq. in 1077 sq. in. 1437 sq. in.
24” 574 sq. in. 862 sq. in. 1150 sq. in.
Griddle Applications include:
• Pancakes, Eggs, Sausage, French Toast
• Burgers, Grilled Onions, Toasted Buns
• Grilled Cheese, Sandwiches
• Fried Potatoes, Fish, Chicken Breasts, Philly Steaks, Liver and MORE
Environmental Approvals & Programs
Other Approvals
NSF/ANSI 4
Options & Accessories
• “U” Channel for connecting 2 griddles
• Front mounted prep shelf—8” wide stainless steel
• Condiment Board
• Maritime Package (call for details)
• Correction Package (call for details)
• Chain Package (call for details)
• Heavy duty stainless steel stand with bottom shelf and 5” casters
EGF-A36 Accu-Steam™
Stand-Mounted Griddle
(also available with bullet
or flanged feet)
MM5205-1605
8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net
MP5018-1605
AccuTemp Products, Inc.
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 7
Accu-Steam Griddle Specifications (replace **** with voltage & phase, i.e. 2083)
Model #
KW Input
208/3 Amp Load
240/1 Amp Load
240/3 Amp Load
440/3 Amp Load
480/3 Amp Load
Unit Width (A)
Unit Depth (D)
Cooking Surface Width (B)
Cooking Surface Depth (C)
Depth to Rear Leg (E)
Center right to left (F)
Effective Cooking Area
Grease Pan Capacity
NEMA Plug (208/240)
NEMA Plug (440/480)
Accu-SteAm™ Griddle eG SerieS
Electric/Steam-Heated, Stand-Mounted Griddle
EGF****A2400-S2 EGF****B2400-S2 EGF****A3600-S2 EGF****B3600-S2 EGF****A4800-S2 EGF****B4800-S2
9.6 kW 9.6 kW 14.25 kW 14.25 kW 14.25 kW 14.25 kW
27 27 40 40 40 40
40 40 n/a n/a n/a n/a
24 24 35 35 35 35
15 15 21 21 21 21
16 16 23 23 23 23
24.25 [616] 24.25 [616] 36.25 [921] 36.25 [921] 48.25 [1226] 48.25 [1226]
34.7 [881] 28.7 [729] 34.7 [881] 28.7 [729] 34.7 [881] 28.7 [729]
23.9 [607] 23.9 [607] 35.9 [912] 35.9 [912] 47.9 [1217] 47.9 [1217]
30 [762] 24 [610] 30 [762] 24 [610] 30 [762] 24 [610]
8.5 [216] 2.5 [64] 8.5 [216] 2.5 [64] 8.5 [216] 2.5 [64]
20 [508] 20 [508] 32 [813] 32 [813] 44 [1117] 44 [1117]
717 sq. in. 574 sq. in. 1077 sq. in. 862 sq. in. 1437 sq. in. 1150 sq. in.
1.25 gal 1.25 gal 1.6 gal 1.6 gal 1.6 gal 1.6 gal
15-50P 15-50P 15-50P 15-50P 15-50P 15-50P
L16-20P L16-20P L16-30P L16-30P L16-30P L16-30P
Notes:
1.) Dimensions in brackets [ ] are metric.
2.) 5’ power cord with plug provided.
8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net
MP5018-1605
AccuTemp Products, Inc.
Accu-Steam™ G2 Electric Installation and Operators Manual
MM5205-1605
PAGE 8
To register this AccuTemp product for warranty complete the following items:
1. Complete the Installation/Operational Checklist and Warranty Registration Form on pages 10-11
2. Mail, fax or scan and e-mail the form to AccuTemp Products, Inc to the contacts listed for each type on the form.
If you have any questions about warranty registration please contact our technical service group. They are available 7 days a week from 7:00 am to 7:00 PM EST.
Toll Free 800 480-0415 Ofce 260 469-3040 Fax 260 469-3045 Email -Service service@accutemp.net Email-Parts parts@accutemp.net Web Site www.accutemp.net
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 9
Yes No
Yes No
Yes No
Yes No Yes No
Yes No
Yes No
15-50P
L16-20P
L16-30P
Store/Location:
Address:
Phone Number:
Fax Number:
Check-Off List
Model #
Serial #
Name of Service/Installer Company:
Is the correct NEMA Plug and Receptacle being used on the Supply Power Cord?
General :
Is the electrical wall receptacle positioned in a low heat-zone?
Note: It is recommended that the wall receptacle be
placed as low as State & Local codes allow. Placement in high heat-zones could cause damage to the electrical cord or plug that would not be covered under the product warranty.
Is the griddle level, both side-to-side and front-to-back?
If this is a table-top installation, have the (4) rubber foot tip/boots been installed?
Electrical Connection :
Is the Supply Power Cord being plugged into a wall outlet?
Is the Supply Power Cord being hard­wired, without the plug, to a breaker box?
Is the Supply Power Cord properly connected to GND?
208/240VAC (All Models)
440/480VAC (24" Models)
440/480VAC (36" & 48" Models)
Type of NEMA Plug?
Installation/Operational Checklist &
Warranty Registration Form
ELECTRIC - ACCU-STEAM™
Failure to accurately complete and provide this Installation/Operational Checklist & Warranty
Registration Form to AccuTemp Products, may delay or void future Warranty Service Calls.
** AccuTemp Products, Inc. is not responsible for the installation and/or modifications to the electrical supply source. **
What is the Electrical Breaker Amperage that will interupt the Supply Voltage to the electric griddle?
AMPS
City:
State:
Zip:
Email:
Technician:
Phone Number:
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 10
Single Φ
Supply Power Electrical Readings :
Temperature & Operational Verification :
I accept and submit this Installation/Operational Checklist & Warranty Registration Form as complete and accurate:
Restaurant/Facility Manager Approval:
Signature
Printed Name
Date:
Note: If the operating temperature is 250°F, then set Thermostat to 300°F and verify surface temperature. If the operating
Page: 2
Measured Amperage on
Mail
Fax
Email
Installation/Operational Checklist &
Warranty Registration Form
ELECTRIC - ACCU-STEAM™
Does the Supply Electrcial Power match the information on the griddle model number?
Phase (Φ)?
Measured Supply
Voltage?
Each Leg?
What is the customer's normal operating Thermostat temperature for the Griddle?
Note: DO NOT use an infrared or flat-top mercury thermometer.
Using a weighted contact temperature probe with digital thermometer, does the surface temperature (°F)
match the normal operating temperature (°F) set on the Thermostat?
temperature is 400°F, then set Thermostat to 400°F and verify surface temperature does not exceed 396°F on the high side of the temperature drift/cycle.
Using a 9 square-grid-pattern on the griddle surface, are the surface temperatures consistant (±5°F)?
Does the Griddle heat light cycle OFF/ON once the surface temperature has reached the Thermostat setting?
=
208VAC 240VAC 440VAC 480VAC
WHT BLK = RED WHT BLK
Yes No
Three Φ
°F
Yes No
Yes No
Yes No
Does the unit operate properly for 15 minutes after the griddle has reached operating temperature?
AccuTemp Products, Inc
Attn: Warranty Administration
Attn: Warranty Administration
260 469-3045
Attn: Warranty Administration
8415 North Clinton Park Dr.
Fort Wayne, IN 46825
Yes No
service@accutemp.net
MP5004-1401
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 11
MODEL G2 ELECTRIC EGF SERIES TABLE TOP & STAND
INSTALLATION INSTRUCTIONS
MP5018-1605
Accu-Steam™ G2 Electric Installation and Operators Manual
PAGE 12
Loading...