INSTALLATION
AND
OPERATION
MANUAL,
SELF
-
GENERATING
STEAM
JACKETED
COUNTER TILTING KETTLES, ACECT-6, ACECT-10, AC
ECT-12
IMPORTANT NOTES FOR INSTALLATION AND
OPERATION
This manual should be retained for future reference.
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
WARNING: Improper installation, operation, adjustment, alteration,
service or maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions
thoroughly before installing, operating or servicing this equipment.
Do not attempt to operate this unit in the event of a power failure.
Adequate clearances must be maintained for safe operation and servicing.
Intended for commercial use only. Not for household use.
NOTICE: Contact the factory, the factory representa
tive or local service
company to perform maintenance and repairs.
PART NUMBER 10132R0 2 2003-02-13
INSTALLATION
AND
OPERATION
MANUAL,
SELF
-
GENERATING
STEAM
JACKETED
COUNTER TILTING KETTLES, ACECT-6, ACECT-10, AC
ECT-12
TABLE OF
CONTENTS
DESCRIPTION
PAGE
IMPORTANT NOTES FOR INSTALLATION AND OPERATION . . . . . . . . . . . . . . . . . . . . . . 2
Immediately after unpacking, check for possible ship
damaged, save the
packaging
materials and contact the carrier within 15 days of delivery.
ping damage. If the kettle is found to be
1. The kettle must be installed in accordance with:
1. State and/or local codes.
2. In the USA, the
Canadian
2. Position
appliance
National
Electrical
Electrical Code, ANSI/NFPA-70 (latest edition). In Canada, the
Code, Part 1, CSA Standard C22.1 (latest edition).
on counter allowing sufficient rear clearance from wall to tilt freely and
completely without obstruction.
3. Mark four corner locations of appliance base.
4. Remove appliance from counter and locate
position
of 4 holes as per Figure 1. Drill four
7/16" diameter holes.
5. Use 5/16-18 Hex Cap Screws with suitable flat washers to bolt down. Screw length must be
1-1/4 long plus counter top thickness.
6. Apply a continuous bead of Silastic or other equ
ivalent sealant along the complete
perimeter edge of the appliance base.
7. Wipe off excess sealant.
8. A Control Box with power supply equivalent to Electrical Rating of appliance should be
located conveniently nearby.
PART NUMBER 10132R0 5 2003-02-13
INSTALLATION
AND
OPERATION
MANUAL,
SELF
-
GENERATING
STEAM
JACKETED
COUNTER TILTING KETTLES, ACECT-6, ACECT-10, AC
1.0 INSTALLATION INSTRUCTIONS (Continued)
WARNING: Disconnect electrical power supply and place a tag at
the disconnect switch to indicate you are on the circuit.
ECT-12
9.A
10. Ground appliance to terminal provided inside console housing.
11. Turn power ON and check for proper operation.
FIGURE 1
waterproof electrical connection
for power supply to console housing must be provided.
PART NUMBER 10132R0 6 2003-02-13
INSTALLATION
AND
OPERATION
MANUAL,
SELF
-
GENERATING
STEAM
JACKETED
COUNTER TILTING KETTLES, ACECT-6, ACECT-10, AC
2.0 INTRODUCTION
ECT-12
DESCRIPTION
Models ACECT-6 (6 gallon capacity) and ACECT-10 (10 gallon capacity) and ACECT-12 (12
gallon capacity)
a
jacket of
kettle. The reservoir is charged with distilled water and
electrically
double-wall
powered, self-contained, countertop, tilting kettles. Each model has
construction forming a sealed reservoir around the lower two-thirds of the
anti-freeze
solution. Kettles are
equipped with a removable electric heating element and controls, including a low water cutoff
device for protection of the heating element. All models are of identical construction, except for
kettle size and element heating capacity.
BASIC FUNCTION
Self-contained kettles operate by generating steam in the kettle reservoir. The sequence of
operation is as follows:
1. Operator turns the power switch to the ON position and sets the
temperature
control dial to
the desired setting from 1 to 10.
2. Control circuit is normally completed to the
temperature
controller if the following conditions
exist:
1. Water level in the kettle reservoir is adequate
to prevent circuit
interruption
by the low
water cut off device. An activated cutoff is indicated by the amber low water light
turning on, and the heating element shut off.
2. Kettle is in vertical position with circuit completed through the tilt interlock switch.
3.Thermostat control contacts close to energize contactor coils.
4.Power is supplied to the elements through closed power contactors.
5.As the temperature of water rises in the kettle reservoir,
indicated on the
pressure
gauge.
incr
ease in steam pressure is
6.When the temperature of steam in the reservoir reaches the setting of the temperature
control dial, the
temperature
controller opens to break the contacts and shuts off the
heating element. The heating elements will cycle on and off as required to maintain
temperature setting.