AccuTemp ACEC-10TW Installation Manual

INSTALLATION AND OPERATION
MANUAL
SELF-GENERATING STEAM JACKETED COUNTER TILTING KETTLES
MODELS: ACEC-6TW
ACEC-10TW ACEC-12TW
PART NUMBER 10121R4
ACCUTEMP PRODUCTS, INC.
8415 North Clinton Park Dr. · Fort Wayne, IN · 46825 800
210-5907 Office · 260 493-0415 Fax ·
www.accutemp.net
1
2
011-09-07
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM JACKETED
COUNTER TILTING KETTLES, MODELS: ACEC-6TW, ACEC-10TW, ACEC-12TW
TABLE OF CONTENTS
DESCRIPTION PAGE
SAFETY .................................................................3
SERVICE CONNECTIONS ...................................................4
1.0 INSTALLATION INSTRUCTIONS ..........................................5
2.0 INTRODUCTION .......................................................7
3.0 OPERATION INSTRUCTIONS ............................................8
4.0 CLEANING INSTRUCTIONS .............................................10
5.0 TROUBLESHOOTING ..................................................11
MATERIAL SAFETY DATA SHEET ...........................................12
PART NUMBER 10121R4 2 2011-09-07
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM JACKETED
COUNTER TILTING KETTLES, MODELS: ACEC-6TW, ACEC-10TW, ACEC-12TW
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
This manual should be read thoroughly and all instructions followed carefully.
Do not attempt to operate this unit in the event of a power failure.
Keep the appliance area free and clear from combustibles.
Do not obstruct the flow of combustion and ventilation air.
Adequate clearances must be maintained for servicing and proper operation.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.
This manual should be retained for future reference.
PART NUMBER 10121R4 3 2011-09-07
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM JACKETED
COUNTER TILTING KETTLES, MODELS: ACEC-6TW, ACEC-10TW, ACEC-12TW
SERVICE CONNECTIONS
AC
AC
AC
AC
AC
AC
AC
AC
PART NUMBER 10121R4 4 2011-09-07
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM JACKETED
COUNTER TILTING KETTLES, MODELS: ACEC-6TW, ACEC-10TW, ACEC-12TW
1.0 INSTALLATION INSTRUCTIONS
Immediately after unpacking, check for possible shipping damage. If the kettle is found to be damaged, save the packaging materials and contact the carrier within 15 days of delivery.
1. The kettle must be installed in accordance with:
1. State and/or local codes.
2. In the USA, the National Electrical Code, ANSI/NFPA-70 (latest edition). In Canada, the Canadian Electrical Code, Part 1, CSA Standard C22.1 (latest edition).
2. Position appliance on counter allowing sufficient rear clearance from wall to tilt freely and completely without obstruction.
3. Mark four corner locations of appliance base.
4. Remove appliance from counter and locate position of 4 holes as per Figure 1. Drill four 7/16" diameter holes.
5. Apply a continuous bead of Silastic or other equivalent sealant along the complete perimeter edge of the appliance base.
6. Use 5/16-18 Hex Cap Screws with suitable flat washers to bolt down. Screw length must be 1-1/4 long plus counter top thickness.
7. Wipe off excess sealant.
8. A Control Box with power supply equivalent to Electrical Rating of appliance should be located conveniently nearby.
WARNING: Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
PART NUMBER 10121R4 5 2011-09-07
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM JACKETED
COUNTER TILTING KETTLES, MODELS: ACEC-6TW, ACEC-10TW, ACEC-12TW
1.0 INSTALLATION INSTRUCTIONS (Continued)
WARNING: Disconnect electrical power supply and place a tag at the disconnect switch to indicate you are on the circuit.
9. A waterproof electrical connection from power supply to console housing must be
provided.
10. Ground appliance to terminal provided inside console housing.
11. Turn power ON and check for proper operation.
Figure 1
PART NUMBER 10121R4 6 2011-09-07
INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM JACKETED
COUNTER TILTING KETTLES, MODELS: ACEC-6TW, ACEC-10TW, ACEC-12TW
2.0 INTRODUCTION
DESCRIPTION
Models EC-6TW (6 gallon capacity) and EC-10TW (10 gallon capacity) and EC-12TW (12 gallon capacity) electrically powered, self-contained, countertop, tilting kettles. Each model has a jacket of double-wall construction forming a sealed reservoir around the lower two-thirds of the kettle. The reservoir is charged with distilled water. Kettles are equipped with a removable electric heating element and controls, including a low water cutoff device for protection of the heating element. All models are of identical construction, except for kettle size and element heating capacity.
BASIC FUNCTION
Self-contained kettles operate by generating steam in the kettle reservoir. The sequence of operation is as follows:
1. Operator turns the power switch to the ON position and sets the temperature control dial to the desired temperature setting.
2. Control circuit is normally completed to the temperature controller if the following conditions exist:
1. Water level in the kettle reservoir is adequate to prevent circuit interruption by the low water cut-off device. An activated cut-off is indicated by the amber low water light turning on, and the heating element shutoff.
2. Kettle is in vertical position with circuit completed through the tilt interlock switch.
3. Thermostat control contacts close to energize contactor coils.
4. Power is supplied to the elements through closed power contactors.
5. As the temperature of water rises in the kettle reservoir, increase in steam pressure is indicated on the pressure gauge.
6. When the temperature of steam in the reservoir reaches the setting of the temperature control dial, the temperature controller opens to break the contacts and shuts off the heating element. On/off cycles will occur as required to maintain temperature setting.