Accusys ExaSAN SW08-Q4 User Manual

SW08-Q4
PCIe Switch
User Guide
Includes setup information for :
Hardware set up: SW08-Q4 PCIe Switch connection with A12S2-PS RAID system and clients using QFSP cables and HBAs. Also includes software installation and setup information for ExaSAN SANit software.
2012, V.1.0
June, 2012 V.1.0
TABLE OF CONTENTS
Page#
1. Hardware Installation
1.1 Checking the Equipment You’ll Need
1.2 Understanding the Installation Steps
1.3
1.4
2. Software Installation and Configuration
2.1
2.2
3. SANit Setup
3.1 SAN Management software Installation
4. Technical Support
Setting up the Hardware Connecting to a Power Source and Powering On
ExaSAN Setup & RAID GuardX RAID Configuration Verify Accessible LUNs
.....................................................................................................................................................
3.2 Connecting the Private LAN
3.3 SANit Configuration
4.1 The System Log
4.2 Contact Us
4.3 Our Website
...................................................................................................................................
.....................................................................................
..........................................................................................
..................................................................................................................
...........................................................
..........................................................................................
.........................................................
...................................................................................................................
................................................................................
.......................................................................................................
..........................................................................................................................
.......................................................................................................................................
..................................................................................................................................
...........................................................................................................................................
.........................................................................................................................................
 
1 3 6 6
9 11 12 17 19 20
20
21 39 40 40
40
1
Hardware
Installation
User Guide
P1
1.Hardware Installation
Congratulations on your purchase of the “Accusys ExaSAN SW08-Q4 Solution” SAN (Storage Area Networ k)
system solution. This User Guide gives you step-by-step setup instructions of a basic system conguration. Our sample conguration consists of one RAID 12-bay disk system, one SW08-Q4 switch. Figure 1 below depicts our
sample ExaSAN Solution setup.
FIGURE 1. Sample ExaSAN Solution Architecture
MDC server
A12S2-PS
RAID Controller
(up to 4)
Although it is not practical to cover all possible scenarios in this guide, most variations of the system conguration can be derived from this sample. If your particular installation encounters a problem that is beyond the scope of this guide, please contact our technical support staff for assistance. ( User requires a system with DDR2 2GB.)
SW08-Q4
Switch
ConnectionLink
QSFP link (A12S2-PS to SW08-Q4) QSFP link (SW08-Q4 to Client) Internet
Client (up to 7)
P2
User Guide
1.1 Checking the Equipment You’ll Need
The list below consists of all the equipment you’ll need to set up the ExaSAN Compact Solution.
Verify that you have all the required system components before beginning hardware installation.
(For details, see the A12S2-PS RAID User Manual)
1. ExaSAN PCIe A12S2-PS RAID disk system, one unit (purchased separately).
2. ExaSAN PCIe Switch SW08-Q4, one unit.
3. ExaSAN PCIe Switch Host Bus Adapte rs, one for each supported workgroup client system (purchased
separately).
4. QSFP PCIe copper or optical cables for connecting the switch to the workgroup client systems, one for each
client system.
5. Power cords, one for the RAID system and another for the switch.
6. CAT-5 cable for the L AN port of the switch, one unit. (For RAID GuardX Congurtion to upgrade rmware.)
User Guide
P3
Package Item Image Item description
1 SW08-Q4 package
QSFP copper or
2
optical cable
PCIe 8-port switch,
supports up to 8 host
systems and PCIe 2.0
RAID systems
Power cord for the
SW08-Q4 switch
CAT-5 cable for the
LAN port of SW08 -Q4
switch(R AID Guard X
congration)
(Option)20Gb QSFP copper
(2M, 5M) or optical cable (10M, 30M, 50M, 100M),
connects SW08- Q4 switch
to QSFP HBA on host
P4
(Option)20Gb QSFP Host
3 QSFP HBA
4 A12S2-PS package
Note: User Guide, and CD (containing the A12S2-PS User Manual) are also included in the SW08 -Q4 package.
Bus Adapter, supports PCIe
2.0 slot
A12S2-PS 20Gb PCIe 2.0
12-bay RAID system,
supports SATA and
SAS drives
Power cord for A12S2-PS
RAID system
2M 20Gb QSFP cable,
connect A12S2-PS
RAID system to the
SW08-Q4 Switch
P5
(...continu ed from page 3)
7. Ethernet switch and CAT-5 patch cables for the private Ethernet network of your SAN, one switch and one cable
for each host system
8. SAN management software (SANit).
9. 12 SAS (Serial Attached SCSI) or SATA (Serial Advanced Technology Attachment) HDD’s for the A12S2-PS RAID disk system (note that Enterprise HDD is recommended)
1.2 Understanding the Installation Steps
Below is an outline of the installation steps for you to follow. Step 1 Unpacking the switch, inspecting the packing list Step 2 Installing Disk Drives, refer to the A12S2-PS User Manual for instructions Step 3 Installing HBA Step 4 Connecting Switch to the RAID Disk System Step 5 Connecting Switch to the Host Systems
Step 6 Connecting the Switch LAN
Step 7 Power-on sequence Step 8 Create Array for SAN Conguration Step 9 SAN Software Installation Step 10 SAN Conguration
1.3 Setting up the Hardware
1.3.1 Installing the HBA
Before the ExaSAN Compact Solution components are ready to be connected and powered on, you must install one HBA in each workgroup client system. The HBA is compatible with PCIe x4, x8, and x16 slots. If a choice is given, use the fastest PCIe slot available. Although the HBA is compatible with both PCIe 1.1 and 2.0 standards, only PCIe 2.0 is recommended for best per formance.
P6
Follow these steps to install the card in each host system:
1. Hold the HBA wi th moun ting plate facing your lef t.
Locate the “mode” jumper switch on the north edge at
center-right, as shown and labeled below.
2. Thi s HBA card can be used both in DAS and SAN app lic ati ons, whether or not the HBA car d was just purchased or originally used in storage. In this case, the HBA c ard is use d for connec ting the C ompac t Switch. Please make sure the switch button is toward the “1” position, as shown below.
3. Position the connector of the card over the slot, insert the connector into the slot, press gently but rmly until
it is securely seated.
4. Secure the metal bracket of the card to the system case with a screw.
5. Replace the outer casing cover.
User Guide
P7
6. Install the HBA device driver a. Insert the Installation CD b. Launch the Installation Package c. Follow the on-screen instructions to complete the driver installation
1.3.2 Connecting the Switch to the RAID System
Use the procedures below to connect the SW08-Q4 Switch to the A12S2-PS RAID system. Note: The top two rows of ports in the rear panel of the SW08- Q4 Switch has eight (8) QSFP ports available for connectivity of up to eight clients. The bottom row of four (4) QSFP por ts are for connectivity of up to four A12S2-PS RAID units.
1. Connect your RAID storage unit to the ExaSAN SW08-Q4 Switch with
an QSFP cable. Insert one end of the PCIe cable into the PCIe por t on the back of the RAID system. Your cable connector is securely plugged when you hear a "click". If you need to unplug the cable, pull the ring on the connector rmly until it is detached from the port.
2. Insert the other end of the cable into one of the three storage module
ports on the rear panel of the ExaSAN switch.
3. Plug a power cord into the AC power-in port in the storage unit; do not
turn power on yet.
Warning:
Follow the power-on sequence shown in 1.4 Connecting to a Power Source and Powering ON.
P8
User Guide
1.3.3 Connecting Switch to the Client System
1. Inser t one end of the QSFP cable into one of the client module ports on the rear panel of the switch. Your
cable connector is securely plugged when you hear a click. If you need to unplug the cable, pull the ring on the connector rmly until it is detached from the port.
2. Insert the other end of the cable into the QSFP port on the HBA,
which you installed on the client system earlier in Section 1.3.1.
3. Repeat steps 1 and 2 for client systems #2.
4. Plug a power cord into the AC power-in por t on the rear panel of the switch. Do not turn power on yet.
1.4 Connecting to a Power Source and Powering On
Before powering on, make sure that all cables and cords are properly installed and connected.
Caution:
Follow the power-on sequence shown bellow to prevent damage to system.
1. If not yet plugged into the wall electrical outlet, plug the power cord for the storage unit and the ExaSAN switch
to a power source.
User Guide
P9
2. Turn power on for the A12S2-PS RAID storage unit rst by pressing the Power button. Access LCD will be blue to indicate A12S2-PS RAID storage unit is
powered-on.
3. Power on the ExaSAN switc h by pressing th e Powe r but ton. Wait for the Heartbeat LED to turn into a steady ashing blue light. Note that you might
hear a few sho rt beeps gen erated fr om the swi tch durin g this pro ce ss.
You may ignore them as they are designed for Accusys internal diagnostic
purposes only.
4. Finally power on the client (workstation) computer system.
No. Name
1
2
3
4
5
Cooling Vents
Power LED Indicator
Access LED Indicator
Fan LED Indic ator
Heartbeat LED Indicator
P10
User Guide
Software Installation
2
and Conguration
User Guide
P11
2. Software Installation and Configuration
Now that we have connected all hardware components and turned on the power, follow the steps in this section to
set up ExaSAN and Sanit.
2.1 ExaSAN Setup & RAID GuardX RAID Configuration
(Please refer to the A12S2-PS RAID User Manual)
2.1.1 Switch GUI Setup
The ExaSAN sw itch has a brows er- ba se d buil t- in GUI (Graphi ca l User Interf ace) for admi nistrat io n and conguration tasks.
2.1.2 Launch the Switch GUI
You may use either the FireFox or Safari browser to access the switch GUI. We recommend that you use FireFox.
1. Launch the browser of your choice
2. Ma ke sure t h at our pr i va te Et her n et netwo r k is
connected
3. Go to IP address 192.168.0.1
4. The GUI’s home page displays
5. Log in with default user name “admin” and password
“0000”
P12
User Guide
2.1.3 Switch GUI Overview
We are now at the switch GUI main menu page. You may toggle between “Cong Mode” and “Monitor Mode” by clicking the “Switch Mode” icon at the top. You may also go into “System Management” to change the switch IP and password, or to set system date and time.
Switch Mode
User Guide
P13
Note that before you perform any system administration function, you should set your system date and time rst.
2.1.4 Quick Setup
We will create two LUNs in the RAID disk system. One is for the Xsan metadata and the other for the user data.
1. Select “Quick Setup” from the menu options on the left pane to start the process
P14
User Guide
2. In the “RAID LEVEL” eld, select “R5” from the drop-down list
3. In the “SAN Software” led, select “SAN With MetaData” from the drop-down list
4. Click “Next”
*Quic k Setup onl y suppor ts one- to-four A12S-PS unit (s). If your RAID system requireme nt is anther form fa ctor like 2U/3U/4U, you may have to res et the setting through RAID Gui de X. Pleas e refer to the Us er Guide for R AID conguration information.
User Guide
A12S2-PS X 1 A12S2-PS X 2
Disk1~10: R5 (Data)
Disk11~12: R1 (Metadata)
R5 (Data) R1 (Metadata)
A12S2-PS X 4
with MDC codition
*
P15
As a result, t wo logical disks will be created as shown in the screenshot below.
5. Click “Apply”
After you click the “Apply” button, the system will start the process of initializing the disks in your RAID storage system. During this process, you may experience deterioration in overall system per formance, this is normal. Please allow suf cient time and patience for this process. Upon completion, the LED indicators on the front panel of your RAID system will ref lect that status. Refer to the appropriate documentation of your RAID system for
additional information.
P16
User Guide
2.2 Verify Accessible LUNs
To view the two LUNs which we just created, open th e M ac “S ystem Pr of iler ” and then ex pand the “Parallel SCSI” tab. You should see that two ExaSAN
LUNs are visible as described below.
Find one LUN in “SCSI target Device @0,” another LUN in “SCSI Target Device @1.” Both are identied with Manufacturer “ACCUSYS” and Model “A12S2­PS.”
Note that you will need to perform this check on all
computers in the SAN. If you do not see any LUN here, you’d have to t roubl eshoot the connection betwe e n th e E x a S A N R AI D sy ste m an d th e
SW08-Q4 switch.
User Guide
P17
P18
User Guide
SANit Setup
3
User Guide
P19
3.1 SAN Management software Installation
SANit is a powerful SAN management software and le system specically designed for extremely reliable high­performance, cross platform and le-level shared access workows. Be sure your MDC eviormnment is all set up already. Begin utilizing your SANit SAN management software by following the steps shown below.
Requirement stuff:
1. MDC server installed Cent OS 5.3 (2.6.18-128.el5)
2. SANit software
3. Licence
4. Ethernet
3.2 Connecting the Private LAN
In addition to the ExaSAN PCIe network, all computers for the SAN must be connected to a private Ethernet network (the Private LAN). SANit MDC servers and clients use this network to exchange le system metadata. Connect each SAN client and MDC server to two Ethernet networks: one private subnet for the SAN metadata and a separate connection for directory service, intranet, and Internet trafc (the Public LAN).
The steps below apply to the Private LAN only. We assume that the Public LAN is already in place.
1. Connect your workgroup client system #1 to the private LAN Ethernet switch with a CAT-5 cable
(Lan switch hub).
2. Repeat Step 1 for client systems #2.
3. Connect the ExaSAN switch to the private LAN Ethernet switch with a CAT-5 cable
(For the monitor switch of the R AID Guard X conguration).
P20
User Guide
Client and metadata controller computers need static (xed) IP addresses for Ethernet network connections. Don’t use DHCP to assign dynamic IP addresses to SANit devices. We suggest that you use the following ranges of IP
addresses for SANit private metadata net work:
• Subnet mask: 255.255.255.0
Software Installation le on MDC
The following is installation command
1. The le name is SANIT-5.3.3-450.x86_64.rpm (Example version)
#rpm –ivh SANIT-5.3.3- 450.x86_64.rpm
#sanit-setup
2. Uninstatall command
#sanit-unsetup
3.3 SANit Configuration
1. Enter your MDC* IP address in the URL of your computer and then
enter port number 85. See below:
http://[MDC IP address]: 85, for example, http://10.10.88.10:85.
2. Sel ect La nguage, enter User Name and Password (Defau lt password is 0000000), and then click Log In.
User Guide
P21
Active SANit
1. License import
2. SAN Volune
3. SAN client
4. SANit client install & set up
3.3.1 Import License
1. Click License and then Import.
P22
User Guide
2. Enter impor t le name and then click Evaluate.
3. Click Import.
User Guide
P23
4. See the information shown below.
P24
User Guide
3.3.2 SAN Volume Creat
1. Select Quick Wizard from the menu. Select Metadata and Data volume devices using the boxes () as shown below. Enter Yes in the congure box below and click Continue.
User can r e-name the SAN volume
If you can't s ee the same amoun t of your volume on the scr een, then do " Rescan" but ton.
User Guide
P25
8. After conguration is 100% completed, see the information below.
P26
User Guide
3.3.3 Add SAN Client
1. Click Client Management and click Add.
2. Enter your computer’s IP address in Client IP box.
User Guide
P27
3. See Client Management screen below.(For checking the states of the added clients)
Make sure that you have seen the RAID Volume then you can do the installation.
3.3.4 Client Install & Set up
1. Click Client Software and Document Downloadation.
Chose what client software that you need then install it.
P28
User Guide
2. Select the Computer Management le in your computer. Select Device Management and then select Disk
drives. Conrm that the device, with installed driver, appears in Disk drive as shown below:
If you can't see the client you created, then you can't mount SAN volume.
User Guide
P29
3. Continue installation using the FS Client 5.3.3 Setup Wizard by clicking Next.
P30
User Guide
4. Enter the Destination Folder and click Next.
User Guide
P31
5. Enter the folder name (FS Client is the default name or you may choose) and then click Install.
P32
User Guide
6. Select Reboot now and click Finish. Computer system will then reboot.
User Guide
P33
7. Select the Start menu in the lower lef t side of your computer screen and select All Programs. Select the FS
Client (Or other folder name, see “Enter the folder name and click Install.”) and then select FS Client.
P34
User Guide
8. See the screen below. Click Server and then right click Add Server.
9. Enter your computer’s server IP Address. Use the same
IP address of your computer MDC (Metadata Controller).
Then click OK.
User Guide
P35
10. Select the server IP Address and then right click Connect Server.
P36
User Guide
11. Click the SAN volume path and then right click Mount.
12. Finally, click the Computer icon on your desk top. See client local hard disks and SAN hard disk storage
location and capacity status as shown below:
User Guide
P37
P38
User Guide
Technical Support
4
User Guide
P39
4. Technical Support
4.1 The System Log
When you contact us for technical support, our support staf f might ask for your system log le for
troubleshooting purpose.
Go to the ExaSAN switch GUI, select the “Event Management” icon. Follow instructions there to download the log le.
4.2 Contact Us
For customer services and technical support, locate an Accusys ofce near you from the link below:
http://www.accusys.com.tw/about/contact.htm
or, you may e-mail us at: support@accusys.com.tw
4.3 Our Website
Please visit our websites frequently for the most up-to-date product and support information.
All countries: www.accusys.com.tw
P40
User Guide
42-33000-5041
Loading...