Preface
Dear Customer,
Thank you for purchasing this surface-fitted/flush-fitting key switch. You made
the right decision in choosing this state-of-the-art technology, which complies
with the current standards of domestic and European regulations. The CE has
been proven and all related certifications are available from the manufacturer
upon request. To maintain this status and to guarantee safe operation, it is your
obligation to observe these operating instructions.
Notes
The key switch is equipped with a burglary/tamper sensor and is used for
switching on or off the alarm system of an entire location or sections of the
location.
It can also be used for controlling other electronic equipment such as machines,
garage doors, etc.
The key switch functions as an impulse or permanent contact, depending on the
settings. The key switch is well protected against external interference, thanks to
the cover contact and the anti-removal wall contact (surface-fitted model only),
as well as the reinforced fascia plate, which prevents removal of the high-quality
ABUS cylinder.
Main features
x Surface-fitted or flush-fitting key switch
x Stable, weatherproof casing
x Reinforced fascia plate to prevent lock removal
x Cover contact and anti-removal wall contact (surface-fitted model only)
x Permanent or impulse contact
x Coloured LEDs (red/yellow)
x Modern, attractive design
Scope of delivery
4 special casing screws with key
1 circular seal black (SE1000 only)
1 sealing plate white (SE1100 only)
4 x 6mm wall plugs including 4.5 x 35mm screws
6

Description
1 2 2 3 1
1 PCB holder
2 Wall fixing
3 Cable hole
Fig. 1 Casing open
(with PCB)
Connections
12V for LED
Ground for LED (red)
Switch S1
Tamper
contacts
NO
COM
NC
NC
NO
COM
Fig. 2 Casing without PCB
S2 S1
2
2
12V for LED
Ground for LED (yellow)
NO
COM
NC
NO
COM
NC
Switch S2
Note:
The switch position described applies when the cover is open.
7

Changing switch mode (impulse/permanent contact)
1. The factory setting of the key switch is
permanent contact. To change the switch
Permanent
Impulse
mode:
2. Remove the upper part of the clamp and
swing it to the side.
3. The key switch is now set to impulse mode.
Installation
1. Using the key supplied, unscrew the cover screws and remove the cover
plate.
2. Remove the two PCB screws on the left and right of the cylinder.
3. Pull the cylinder and PCB carefully upwards and out.
4. Use the back of the key-switch case as a template for marking the drill
holes (2). Drill the holes for the fixing screws.
5. Pull the connector cable through the opening provided.
6. Fix the casing to or in the wall.
7. Connect the cables to the terminal block (8) as described.
8. Replace the PCB in the casing, replace the cover (1) and tighten the cover
screws. Make sure that the sealing ring sits firmly in the housing groove.
Technical data
Voltage supply LED 10–15 V DC
Max. power consumption per LED 2mA
Maximum contact capacity 30V DC / 0.5A
Dimensions (surface fitting) 85 x 114 x 42mm (WxHxD)
Dimensions (flush fitting) 106 x 134 x 42mm (WxHxD)
Protection type IP55
Number of contacts 3 (switchable)
Weight 450g
The manufacturer reserves the right to make technical modifications without
prior notice.
8