ABUS SE1000, SE1100 User guide

Key switch
INSTALLATION GUIDE
SE1000
SE1100
5
Preface
Dear Customer,
Notes
The key switch is equipped with a burglary/tamper sensor and is used for switching on or off the alarm system of an entire location or sections of the location. It can also be used for controlling other electronic equipment such as machines, garage doors, etc. The key switch functions as an impulse or permanent contact, depending on the settings. The key switch is well protected against external interference, thanks to the cover contact and the anti-removal wall contact (surface-fitted model only), as well as the reinforced fascia plate, which prevents removal of the high-quality ABUS cylinder.
Main features
x Surface-fitted or flush-fitting key switch x Stable, weatherproof casing x Reinforced fascia plate to prevent lock removal x Cover contact and anti-removal wall contact (surface-fitted model only) x Permanent or impulse contact x Coloured LEDs (red/yellow) x Modern, attractive design
Scope of delivery
4 special casing screws with key 1 circular seal black (SE1000 only) 1 sealing plate white (SE1100 only) 4 x 6mm wall plugs including 4.5 x 35mm screws
6
Description
1 2 2 3 1
1 PCB holder 2 Wall fixing 3 Cable hole
Fig. 1 Casing open
(with PCB)
Connections
12V for LED
Ground for LED (red)
Switch S1
Tamper
contacts
NO COM NC
NC NO COM
Fig. 2 Casing without PCB
S2 S1
2 2
12V for LED
Ground for LED (yellow)
NO COM NC
NO COM NC
Switch S2
Note:
The switch position described applies when the cover is open.
7
Changing switch mode (impulse/permanent contact)
1. The factory setting of the key switch is permanent contact. To change the switch
Permanent
Impulse
mode:
2. Remove the upper part of the clamp and swing it to the side.
3. The key switch is now set to impulse mode.
Installation
1. Using the key supplied, unscrew the cover screws and remove the cover plate.
2. Remove the two PCB screws on the left and right of the cylinder.
3. Pull the cylinder and PCB carefully upwards and out.
4. Use the back of the key-switch case as a template for marking the drill holes (2). Drill the holes for the fixing screws.
5. Pull the connector cable through the opening provided.
6. Fix the casing to or in the wall.
7. Connect the cables to the terminal block (8) as described.
8. Replace the PCB in the casing, replace the cover (1) and tighten the cover screws. Make sure that the sealing ring sits firmly in the housing groove.
Technical data
Voltage supply LED 10–15 V DC Max. power consumption per LED 2mA Maximum contact capacity 30V DC / 0.5A Dimensions (surface fitting) 85 x 114 x 42mm (WxHxD) Dimensions (flush fitting) 106 x 134 x 42mm (WxHxD) Protection type IP55 Number of contacts 3 (switchable) Weight 450g
The manufacturer reserves the right to make technical modifications without prior notice.
8